首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of this study was to determine if segmental skeletal length contributes to vertical jump (VJ) displacement in recreational athletes. Skeletal length measurements of the trunk, femur, tibia, and foot were obtained by palpation of bony landmarks and a standard tape measure. A pilot study (n = 10) examined the intratester and intertester reliability for each skeletal measure. The pilot investigation revealed fair to excellent intratester and intertester reliability. Seventy-eight recreational athletes (55 men and 23 women) with a mean age of 21.9 +/- 2.9 years participated in the investigation. Multiple regression analysis with gender as a categorical indicator variable revealed a significant gender difference; therefore, men and women were analyzed separately. Regression analysis for men identified foot length (p < 0.033, R(2) = 0.08) as the only significant skeletal length predictor of VJ displacement. None of the skeletal length measures was predictive of VJ displacement in women. Based on the results of this investigation, intrinsic skeletal length is not a strong predictor of VJ displacement in young adult recreational athletes.  相似文献   

2.
The purposes of this study were twofold: (a) to examine the test-retest reproducibility and concurrent validity of the horizontal hip joint angle test (H-HJA) and vertical hip joint angle test (V-HJA) for estimating hamstring flexibility measured with an inclinometer during the passive straight-leg raise test (PSLR) and (b) to determine whether the H-HJA cutoff scores may be used for V-HJA for the detection of short hamstring flexibility in active recreationally young adults. Fifty young men underwent the H-HJA, V-HJA, and PSLR on the right and left legs 3 times in a randomized order with a 4-week interval between trials under a controlled laboratory environment. Reproducibility was examined using coefficient of variation (CV) and intraclass correlation coefficient (ICC3,1) and their respective confidence limits. Regression and kappa correlation analyses were performed to examine the association of H-HJA and V-HJA with the PSLR test, and the 95% limits of agreement between H-HJA and V-HJA were calculated to check if there were differences in the raising scores. The results demonstrated acceptable reproducibility measures for the H-HJA (4.12% CV; 0.93 ICC), V-HJA (4.99% CV; 0.92 ICC), and PSLR (4.83% CV; 0.88 ICC). The H-HJA (R = 0.62) and V-HJA (R = 0.63) results were significantly associated with those of the PSLR. The 95% limits of agreement between the H-HJA and V-HJA reported systematic bias (+7.12 cm) and a wide 95% random error ( ±13.72 cm). This study concluded that the test-retest reproducibility of the H-HJA, V-HJA, and PSLR is acceptable and that the validity of H-HJA and V-HJA is moderate. Furthermore, the H-HJA cutoff scores should not be used for V-HJA for the detection of short hamstring muscles in young adults.  相似文献   

3.

Background and Objective

The STarT Back Tool uses prognostic indicators to classify patients with low back pain into three risk groups to guide early secondary prevention in primary care. The present study aimed to evaluate the psychometric properties of the Japanese version of the tool (STarT-J).

Methods

An online survey was conducted among Japanese patients with low back pain aged 20–64 years. Reliability was assessed by examining the internal consistency of the overall and psychosocial subscales using Cronbach’s alpha coefficients. Spearman’s correlation coefficients were used to evaluate the concurrent validity between the STarT-J total score/psychosocial subscore and standard reference questionnaires. Discriminant validity was evaluated by calculating the area under the curves (AUCs) for the total and psychosocial subscale scores against standard reference cases. Known-groups validity was assessed by examining the relationship between low back pain-related disability and STarT-J scores.

Results

The analysis included data for 2000 Japanese patients with low back pain; the mean (standard deviation [SD]) age was 47.7 (9.3) years, and 54.1% were male. The mean (SD) STarT-J score was 2.2 (2.1). The Cronbach’s alpha coefficient was 0.75 for the overall scale and 0.66 for the psychosocial subscale. Spearman’s correlation coefficients ranged from 0.30 to 0.59, demonstrating moderate to strong concurrent validity. The AUCs for the total score ranged from 0.65 to 0.83, mostly demonstrating acceptable discriminative ability. For known-groups validity, participants with more somatic symptoms had higher total scores. Those in higher STarT-J risk groups had experienced more low back pain-related absences.

Conclusions

The overall STarT-J scale was internally consistent and had acceptable concurrent, discriminant, and known-groups validity. The STarT-J can be used with Japanese patients with low back pain.  相似文献   

4.
The height of the medial longitudinal arch (MLA) is thought to be a predisposing factor to various lower extremity injuries. Discrepancy exists as to whether MLA height plays a role in injury prevention. The purpose of this study was to determine the intertester and intratester reliability, and the validity of the mirrored foot photo box (MFPB) and caliper measurements to radiographic measurements. METHODS: Thirty subjects with equal numbers of men and women were recruited. Both feet were tested (n=60) in a 90% weight bearing stance. A set of anatomic landmarks were palpated, marked, and measured using a caliper, MFPB, and radiographs. The protocol was completed by two testers on 2 days approximately 1 week apart. Intertester and intratester reliability were determined using the intraclass correlation coefficient (ICC)(2,k) and the ICC(2,1), respectively. Validity of both measurement techniques to radiographic measurements was determined using the ICC(2,k). RESULTS: The intertester reliability ranged from 0.991 to 0.577, while the intratester reliability ranged from 0.994 to 0.527, with first metatarsal angle being the only variable with poor reliability. Most variables demonstrated acceptable validity between the MFPB and the caliper measurements, and acceptable validity between the MFPB and calipers compared to radiographic measurements. The MFPB took 51.3+/-19.6s per foot while the caliper measurements averaged 227.4+/-68.9s to complete the measurements. DISCUSSION: The MFPB is as reliable as the caliper measurements, and offers better intertester reliability. Both the caliper and MFPB measurements demonstrated acceptable validity to radiographic measurements and testing time was reduced when using the MFPB compared to calipers.  相似文献   

5.
The purpose of this study was to establish validity and reliability evidence for the medicine ball throw test for kindergarten students, an underrepresented group in the literature. The subjects were 105 students, 5-7 years old, BMI 17.44 +/- 3.17 kg x m(-2), 43% female and 57% male. Intraclass correlation coefficients (ICCs) were used to examine reliability, and Pearson correlation coefficients and a paired t-test were used to examine validity. To accomplish this, the kindergarten students completed the medicine ball throw test on two different days and the modified pull-up test, the "criterion" measure, on another day. For the medicine ball throw, each student sat on the floor before throwing the medicine ball forward like a chest pass three times. The medicine ball throw was highly reliable both within 1 day (ICCs = 0.93 and 0.94 for day 1 and day 2, respectively) and across 2 days (ICC = 0.88), with all reliability estimates over the acceptable level of 0.80. The medicine ball throw scores were positively related with height (r = 0.34) and weight (r = 0.34), and there was a significant difference between the 5-year-old group (mean +/- SD; 111.78 +/- 34.93) and the 6-year-old group (135.60 +/- 39.77), t = -3.23, p = 0.002, which supports correlational and known-difference evidence of validity for the medicine ball throw test. Even though no correlation was found between the medicine ball throw test and the modified pull-up test, r = -0.04, other forms of validity evidence (i.e., known-difference and correlational) were apparent. In conclusion, the medicine ball throw test seems to be a valid and reliable measure of upper-body strength for kindergarten children.  相似文献   

6.
凡纳对虾形态性状对体重的影响效果分析   总被引:58,自引:1,他引:58  
选择 6月龄凡纳对虾 176只 ,测定了体长、头胸甲长、胸宽、胸高、额剑上刺数、额剑下刺数、尾长和上市体重共 8个性状 ,采用相关分析和通径分析方法 ,剔除了与体长及头胸甲长有共线性的自变量尾长 ,计算了以形态性状为自变量对体重作依变量的相关系数、通径系数、决定系数及相关指数 ,定量地分析了形态性状对体重的影响效果。结果表明 ,凡纳对虾 5个形态性状与体重的相关系数达到极显著水平 (P<0 .0 1) ;通径分析揭示了多元分析中多个自变量与依变量的真实关系 ,体长、头胸甲长、胸宽、额剑下缘刺数目对体重的通经系数达到显著水平 ,它们是直接影响体重的重要指标 ,其中体长对体重的直接影响(0 .4 2 8* * )最大 ,是影响体重的最主要因素 ,其次为头胸甲长 (0 .2 90 * * )和胸宽 (0 .2 4 5 * * ) ,额剑下缘刺数对体重的直接影响(0 .0 70 * )较小 ;胸高与体重的相关程度很大 (0 .792 3) ,但它与额剑上缘刺数对体重的直接影响都非常小 ,主要通过其他性状间接影响活体重 ,是影响体重的次要因素 ,均被剔除 ;决定系数分析结果与通径分析结果有一致的变化趋势 ;所选形态性状与体重的复相关指数为 R2 =0 .92 13,说明影响体重的主要自变量指标已经找到 ;多元回归分析建立了体长 (X1 )、头胸甲长 (X2 )、胸宽(X3)、  相似文献   

7.
This study compares the effects of 3 common stretching techniques on the length of the hamstring muscle group during a 4-week training program. Subjects were 19 young adults between the ages of 21 and 35. The criterion for subject inclusion was tight hamstrings as defined by a knee extension angle greater than 20 degrees while supine with the hip flexed 90 degrees . The participants were randomly assigned to 1 of 4 groups. Group 1 (n = 5) was self-stretching, group 2 (n = 5) was static stretching, group 3 (n = 5) was proprioceptive neuromuscular facilitation incorporating the theory of reciprocal inhibition (PNF-R), and group 4 (n = 4) was control. Each group received the same stretching dose of a single 30-second stretch 3 days per week for 4 weeks. Knee extension angle was measured before the start of the stretching program, at 2 weeks, and at 4 weeks. Statistical analysis (p < or = 0.05) revealed a significant interaction of stretching technique and duration of stretch. Post hoc analysis showed that all 3 stretching techniques increase hamstring length from the baseline value during a 4-week training program; however, only group 2 (static stretching) was found to be significantly greater than the control at 4 weeks. These data indicate that static stretching 1 repetition for 30 seconds 3 days per week increased hamstring length in young healthy subjects. These data also suggest that active self-stretching and PNF-R stretching 1 repetition for 30 seconds 3 days per week is not sufficient to significantly increase hamstring length in this population.  相似文献   

8.
Spatiotemporal characteristics of gait such as step time and length are often associated with overall physical function in clinical populations, but can be difficult, time consuming and obtrusive to measure. This study assessed the concurrent validity of overground walking spatiotemporal data recorded using a criterion reference – a marker-based three-dimensional motion analysis (3DMA) system – and a low-cost, markerless alternative, the automated skeleton tracking output from the Microsoft Kinect™ (Kinect). Twenty-one healthy adults performed normal walking trials while being monitored using both systems. The outcome measures of gait speed, step length and time, stride length and time and peak foot swing velocity were derived using supervised automated analysis. To assess the agreement between the Kinect and 3DMA devices, Bland–Altman 95% bias and limits of agreement, percentage error, relative agreement (Pearson's correlation coefficients: r) overall agreement (concordance correlation coefficients: rc) and landmark location linearity as a function of distance from the sensor were determined. Gait speed, step length and stride length from the two devices possessed excellent agreement (r and rc values >0.90). Foot swing velocity possessed excellent relative (r=0.93) but only modest overall (rc=0.54) agreement. Step time (r=0.82 and rc=0.23) and stride time (r=0.69 and rc=0.14) possessed excellent and modest relative agreement respectively but poor overall agreement. Landmark location linearity was excellent (R2=0.991). This widely available, low-cost and portable system could provide clinicians with significant advantages for assessing some spatiotemporal gait parameters. However, caution must be taken when choosing outcome variables as some commonly reported variables cannot be accurately measured.  相似文献   

9.
Medication non-adherence is a prevalent problem worldwide but up to today, no gold standard is available to assess such behavior. This study was to evaluate the psychometric properties, particularly the concurrent validity of the English version of the Malaysian Medication Adherence Scale (MALMAS) among people with type 2 diabetes in Malaysia. Individuals with type 2 diabetes, aged 21 years and above, using at least one anti-diabetes agent and could communicate in English were recruited. The MALMAS was compared with the 8-item Morisky Medication Adherence Scale (MMAS-8) to assess its convergent validity while concurrent validity was evaluated based on the levels of glycated hemoglobin (HbA1C). Participants answered the MALMAS twice: at baseline and 4 weeks later. The study involved 136 participants. The MALMAS achieved acceptable internal consistency (Cronbach’s alpha=0.565) and stable reliability as the test-retest scores showed fair correlation (Spearman’s rho=0.412). The MALMAS has good correlation with the MMAS-8 (Spearman’s rho=0.715). Participants who were adherent to their anti-diabetes medications had significantly lower median HbA1C values than those who were non-adherence (7.90 versus 8.55%, p=0.032). The odds of participants who were adherent to their medications achieving good glycemic control was 3.36 times (95% confidence interval: 1.09-10.37) of those who were non-adherence. This confirms the concurrent validity of the MALMAS. The sensitivity of the MALMAS was 88.9% while its specificity was 29.6%. The findings of this study further substantiates the reliability and validity of the MALMAS, in particular its concurrent validity and sensitivity for assessing medication adherence of people with type 2 diabetes in Malaysia.  相似文献   

10.
The aims of this study were (a) to identify and compare the speed and agility of 12- and 14-year-old elite male basketball players and (b) to investigate relations between speed and agility for both age groups of basketball players, to help coaches to improve their work. Sixty-four players aged 12 (M = 11.98 years, SD = 0.311) and 54 players aged 14 (M = 14.092 years, SD = 0.275) were tested. Three agility tests: agility t-test, zigzag agility drill, and agility run 4 × 15 m and 3 speed tests: 20-m run, 30-m run, and 50-m run were applied. Fourteen-year-old players achieved significantly better results in all speed and agility tests compared with 12-year-old players. The correlation coefficient (r = 0.81, p = 0.001) showed that 12-year-old players have the same ability in the 30- and 50-m runs. The other correlation coefficient (r = 0.59, p = 0.001) indicated that 20- and 30-m runs had inherently different qualities. The correlation coefficients between agility tests were <0.71, and therefore, each test in this group represents a specific task. In 14-year-old players, the correlation coefficients between the speed test results were <0.71. In contrast, the correlation coefficients between the agility tests were >0.71, which means that all the 3 tests represent the same quality. During the speed training of 12-year-old players, it is advisable to focus on shorter running distances, up to 30 m. During the agility training of the same players, it is useful to apply exercises with various complexities. In speed training of the 14-year-old players, the 30- and 50-m runs should be applied, and agility training should include more specific basketball movements and activities.  相似文献   

11.
The primary aim of this study was to determine reliability and factorial validity of squat (SJ) and countermovement jump (CMJ) tests. The secondary aim was to compare 3 popular methods for the estimation of vertical jumping height. Physical education students (n = 93) performed 7 explosive power tests: 5 different vertical jumps (Sargent jump, Abalakow's jump with arm swing and without arm swing, SJ, and CMJ) and 2 horizontal jumps (standing long jump and standing triple jump). The greatest reliability among all jumping tests (Cronbach's alpha = 0.97 and 0.98) had SJ and CMJ. The reliability alpha coefficients for other jumps were also high and varied between 0.93 and 0.96. Within-subject variation (CV) in jumping tests ranged between 2.4 and 4.6%, the values being lowest in both horizontal jumps and CMJ. Factor analysis resulted in the extraction of only 1 significant principal component, which explained 66.43% of the variance of all 7 jumping tests. Since all jumping tests had high correlation coefficients with the principal component (r = 0.76-0.87), it was interpreted as the explosive power factor. The CMJ test showed the highest relationship with the explosive power factor (r = 0.87), that is, the greatest factorial validity. Other jumping tests had lower but relatively homogeneous correlation with the explosive power factor extracted. Based on the results of this study, it can be concluded that CMJ and SJ, measured by means of contact mat and digital timer, are the most reliable and valid field tests for the estimation of explosive power of the lower limbs in physically active men.  相似文献   

12.
The purpose of this study was to compare the architectural parameters of the long head of biceps femoris (BFlh) and semitendinosus (ST) muscles by comparing measurements from ultrasound (US) with those obtained from direct dissection. The BFlh and ST architectures were examined bilaterally in 6 legs from 3 male cadavers. The fascicle length, pennation angle, muscle thickness and muscle and tendon length were obtained from direct measurement and US scans along each muscle. Intraclass correlation coefficients between the two methods ranged from 0.905 to 0.913 for the BFlh variables and from 0.774 to 0.974 for the ST parameters. Compared with the direct measurements, the US method showed a mean typical error of 0.09–0.14 cm for muscle thickness, 1.01–1.31° for the pennation angle, 0.92–1.71 cm for fascicle length and muscle–tendon length measurements. The US method is a valid alternative tool for assessing basic architectural parameters of ST and BFlh components of the hamstring muscles.  相似文献   

13.
The purposes of this investigation were to establish the reliability of selected physical performance tests in women athletes and nonathletes and to determine performance differences between groups. Fifty women (25 athletes, 25 nonathletes) performed 5 tests in 2 sessions. The performance tests included the figure-eight hop test, up-and-down hop test, side-to-side hop test, hexagon hop test, and zigzag run test. Intraclass correlation coefficients (ICC [2, 1]) were calculated for trial-to-trial, intertester, and day-to-day reliability. Independent t-tests with Bonferroni adjustment (alpha = 0.01) were used for each individual test to compare differences between groups. All tests showed good reliability values (ICC > or = 0.76) in the nonathlete group for all conditions and varied reliability values (0.48-0.99) among conditions in the athlete group. The independent t-tests showed a statistically significant group effect (t > or = 3.041; p < or = 0.004) for all tests. The results showed that these physical performance tests are reliable measurement tools in the female population.  相似文献   

14.
15.

Objective

To develop and validate the Adult Hypopituitarism Questionnaire (AHQ) as a disease-specific, self-administered questionnaire for evaluation of quality of life (QOL) in adult patients with hypopituitarism.

Methods

We developed and validated this new questionnaire, using a standardized procedure which included item development, pilot-testing and psychometric validation. Of the patients who participated in psychometric validation, those whose clinical conditions were judged to be stable were asked to answer the survey questionnaire twice, in order to assess test-retest reliability.

Results

Content validity of the initial questionnaire was evaluated via two pilot tests. After these tests, we made minor revisions and finalized the initial version of the questionnaire. The questionnaire was constructed with two domains, one psycho-social and the other physical. For psychometric assessment, analyses were performed on the responses of 192 adult patients with various types of hypopituitarism. The intraclass correlations of the respective domains were 0.91 and 0.95, and the Cronbach’s alpha coefficients were 0.96 and 0.95, indicating adequate test-retest reliability and internal consistency for each domain. For known-group validity, patients with hypopituitarism due to hypothalamic disorder showed significantly lower scores in 11 out of 13 sub-domains compared to those who had hypopituitarism due to pituitary disorder. Regarding construct validity, the domain structure was found to be almost the same as that initially hypothesized. Exploratory factor analysis (n = 228) demonstrated that each domain consisted of six and seven sub-domains.

Conclusion

The AHQ showed good reliability and validity for evaluating QOL in adult patients with hypopituitarism.  相似文献   

16.
The present study describes the development and initial validation of a new obesity‐specific, self‐report measure of health‐related quality of life (HRQOL) for children aged 5–13 years. Participants included 141 obese children (mean age = 9.2 years, 67% female, 55% black, mean zBMI = 2.52) and their primary caregivers. Children completed Sizing Me Up (obesity‐specific HRQOL) and the PedsQL (generic HRQOL). Item content for Sizing Me Up was based on the published child obesity and HRQOL literatures and expert opinion. Items use phrasing to orient children to respond to questions in context of his/her size (e.g., “were teased by other kids because of your size”). Caregivers completed Sizing Them Up, a parallel parent‐proxy, obesity‐specific HRQOL measure. Initial psychometric evaluation of Sizing Me Up was completed by conducting a factor analysis and determining internal consistency, test–retest reliability, and convergent and construct validity. Sizing Me Up is a 22‐item measure with five scales (i.e., Emotional Functioning, Physical Functioning, Social Avoidance, Positive Social Attributes, and Teasing/Marginalization) that account for 57% of the variance and a total HRQOL score. Internal consistency coefficients range from 0.68 to 0.85. Test–retest reliabilities range from 0.53 to 0.78. Good convergent validity was demonstrated with the PedsQL (rs = 0.35–0.65) and the parent‐proxy Sizing Them Up (rs = 0.22–0.44). Sizing Me Up represents the first obesity‐specific HRQOL measure developed specifically for younger school‐aged children (aged 5–13 years) with preliminary evidence of strong psychometric properties that likely has both clinical and research utility in a variety of settings.  相似文献   

17.
Xia W  Sun C  Zhang L  Zhang X  Wang J  Wang H  Wu L 《PloS one》2011,6(5):e19656

Background

This study aims to evaluate the reproducibility and validity of a food frequency questionnaire (FFQ) developed for female adolescents in the Suihua area of North China. The FFQ was evaluated against the average of 24-hour dietary recalls (24-HRs).

Methodology/Principal Findings

A total of 168 female adolescents aged 12 to 18 completed nine three consecutive 24-HRs (one three consecutive 24 HRs per month) and two FFQs over nine months. The reproducibility of the FFQ was estimated using intraclass correlation coefficients (ICCs), and its relative validity was assessed by comparing it with the 24-HRs. The mean values of the 24-HRs were lower than those of the FFQs, except for protein (in FFQ1) and iron (in FFQ2). The ICCs for all nutrients and food groups in FFQ1 and FFQ2 were moderately correlated (0.4–0.8). However, all the ICCs decreased after adjusting for energy. The weighted κ statistic showed moderate agreement (0.40–0.6) for all nutrients and food groups, except for niacin and calcium, which showed poor agreement (0.35). The relative validity results indicate that the crude Spearman''s correlation coefficients of FFQ1 and the 24-HRs ranged from 0.41 (for Vitamin C) to 0.65 (for fruit). The coefficients of each nutrient and food group in FFQ2 and the 24-HRs were higher than those in FFQ1 and the 24-HRs, indicating good correlation. Although all energy-adjusted Spearman''s correlation coefficients were lower than the crude coefficients, de-attenuation to correct for intra-individual variability improved the correlation coefficients. The weighted κ coefficients of nutrients and food groups ranged from 0.32 for beans to 0.52 for riboflavin in FFQ1 and the 24-HRs, and 0.32 for Vitamin C to 0.54 for riboflavin in FFQ2 and the 24-HRs.

Conclusion

The FFQ developed for female adolescents in the Suihua area is a reliable and valid instrument for ranking individuals within this study.  相似文献   

18.

Background

The ability to perform a cognitive task while walking simultaneously (dual-tasking) is important in real life. However, the psychometric properties of dual-task walking tests have not been well established in stroke.

Objective

To assess the test-retest reliability, concurrent and known-groups validity of various dual-task walking tests in people with chronic stroke.

Design

Observational measurement study with a test-retest design.

Methods

Eighty-eight individuals with chronic stroke participated. The testing protocol involved four walking tasks (walking forward at self-selected and maximal speed, walking backward at self-selected speed, and crossing over obstacles) performed simultaneously with each of the three attention-demanding tasks (verbal fluency, serial 3 subtractions or carrying a cup of water). For each dual-task condition, the time taken to complete the walking task, the correct response rate (CRR) of the cognitive task, and the dual-task effect (DTE) for the walking time and CRR were calculated. Forty-six of the participants were tested twice within 3–4 days to establish test-retest reliability.

Results

The walking time in various dual-task assessments demonstrated good to excellent reliability [Intraclass correlation coefficient (ICC2,1) = 0.70–0.93; relative minimal detectable change at 95% confidence level (MDC95%) = 29%-45%]. The reliability of the CRR (ICC2,1 = 0.58–0.81) and the DTE in walking time (ICC2,1 = 0.11–0.80) was more varied. The reliability of the DTE in CRR (ICC2,1 = -0.31–0.40) was poor to fair. The walking time and CRR obtained in various dual-task walking tests were moderately to strongly correlated with those of the dual-task Timed-up-and-Go test, thus demonstrating good concurrent validity. None of the tests could discriminate fallers (those who had sustained at least one fall in the past year) from non-fallers.

Limitation

The results are generalizable to community-dwelling individuals with chronic stroke only.

Conclusions

The walking time derived from the various dual-task assessments generally demonstrated good to excellent reliability, making them potentially useful in clinical practice and future research endeavors. However, the usefulness of these measurements in predicting falls needs to be further explored. Relatively low reliability was shown in the cognitive outcomes and DTE, which may not be preferred measurements for assessing dual-task performance.  相似文献   

19.
Comparisons of embryo length, ISTA (International Seed Testing Association), cold (10 oC), controlled-deterioration, and slope tests for estimating seedling size variability and percentage seedling emergence were made using eighteen stocks of carrot seeds. The coefficient of variation (C.V.) of seedling weight was closely correlated with the C.V. of embryo length (r = 0–87 D.F., 16) and also with the C.V. of root length from the slope test (r = 0–63 D.F., 16). Poorer estimates of percentage seedling emergence were obtained from the cold test in all three sowings (correlation coefficients were between 0–65 and 0–70 D.F., 16) compared with the ISTA, controlled deterioration, and slope tests. For these three tests the correlation coefficients varied between 0–80 and 0–87 (D.F., 16) for all sowings. The embryo test is a rapid (1 man hour per seed lot) and accurate method of assessing potential variability between seed lots. The slope test could provide a less labour demanding method of assessing potential variability than the embryo length test though the results would not be available immediately. However, the slope test could also provide as good an estimate of seedling emergence in the field as the ISTA or controlled-deterioration tests.  相似文献   

20.
Soccer players may develop recurrent hamstring injuries. This may be due to inadequate rehabilitation or to recurrent injury. In addition, following injury, the hamstring muscular complex may be permanently damaged, resulting in decreased strength, and increased likelihood of recurrent injury. Fourteen professional soccer players were assessed by clinical examination and by isokinetic testing with a Cybex II machine. Seven had suffered moderate or major hamstring injuries in the past year. There were seven controls. None of the hamstring group were currently suffering from an acute hamstring injury. The results of the two groups were compared. There were no differences in the mean results. This pilot study suggests that no permanent functional damage occurs to the muscular complex after moderate or major hamstring injuries after correct treatment. However, further research is required to confirm this.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号