1.
Drug-coated balloons are medical devices designed to locally deliver drug to diseased segments of the vessel wall. For these dosage forms, drug transfer to the vessel wall needs to be examined in detail, since drug released into the blood is cleared from the site. In order to examine drug transfer, a new in vitro setup was developed combining the estimation of drug loss during advancement to the site of application in a model coronary artery pathway with a hydrogel compartment representing, as a very simplified model, the vessel wall. The transfer of fluorescent model substances as well as the drug paclitaxel from coated balloons to the simulated vessel wall was evaluated using this method. The model was suitable to quantify the fractions transferred to the hydrogel and also to qualitatively assess distribution patterns in the hydrogel film. In the case of fluorescein sodium, rhodamin b and paclitaxel, vast amounts of the coated substance were lost during the simulated passage and only very small fractions of about 1% of the total load were transferred to the gel. This must be attributed to good water solubility of the fluorescent substances and the mechanical instability of the paclitaxel coating. Transfer of the hydrophobic model substance triamterene was however nearly unaffected by the preliminary tracking procedure with transferred fractions ranging from 8% to 14%. Analysis of model substance distribution yielded inhomogeneous distributions indicating that the coating was not evenly distributed on the balloon surface and that a great fraction of the coating liquid did not penetrate the folds of the balloon. This finding is contradictory to the generally accepted assumption of a drug depot inside the folds and emphasizes the necessity to thoroughly characterize in vitro performance of drug-coated balloons to support the very promising clinical data.  相似文献   

2.
In situ gelling formulations allow easy application to the target area. Gelation is induced by physiological stimuli at the site of application where the formula attains semisolid properties and exerts sustained drug release. In situ gelling formulations containing either 3% meloxicam (Mx) or 2% minocycline HCl (MH) were prepared for local application into the periodontal pockets. Gel formulations were based on the thermosensitive Pluronic® (Pl) and the pH-sensitive Carbopol® (C) polymers. C gels were prepared in combination with HPMC (H) to decrease its acidity. The total percent drug released from Pl formulae was 21.72% after 1 week for Mx and 85% after 3 days for MH. Their release kinetics data indicated anomalous non-Fickian behavior that could be controlled by both diffusion and chain relaxation. Addition of MH to C/H gels (1:2.5) resulted in liquefaction, followed by drug precipitation. Regarding C/H gel containing Mx, it showed a prolonged release rate up to 7 days with an initial burst effect; the kinetics data revealed Fickian-diffusion mechanism. The in vitro antibacterial activity studies for MH gel in Pl revealed that the drug released exceeded the minimum inhibitory concentration (MIC) of MH against Staphylococcus aureus ATCC 6538; placebo gel showed no effect on the microorganism. Clinical evaluation of Pl gels containing either Mx or MH showed significant improvement in chronic periodontitis patients, manifested by decrease in pocket depth and gingival index and increase in bone density.  相似文献   

3.
The objective of the present investigation was to formulate solid lipid nanoparticles (SLN) and nanostructured lipid carriers (NLC) for improving the dermal delivery of a local anesthetic agent lidocaine (LID). SLN and NLC were characterized for particle size distribution, polydispersity index, entrapment efficiency, X-ray powder diffraction pattern (XRD), thermal behavior by differential scanning colorimeter (DSC) and surface morphology by transmission electron microscopy (TEM). LID-loaded SLN and NLC were formulated into hydrogels for topical application. The in vitro permeation profiles of LID SLN gel, LID NLC gel, and a marketed LID formulation (Xylocaine® gel) were evaluated by using guinea pig skin. The in vivo efficacy of LID SLN gel, LID NLC gel, and a marketed LID formulation (Xylocaine® gel) gel was evaluated on guinea pig using pinprick test. LID SLN showed a particle size of 78.1 nm with a polydispersity index of 0.556, whereas LID NLC showed a particle size of 72.8 nm with a polydispersity index of 0.463. The entrapment efficiency of LID in both SLN and NLC was 97% and 95.9%, respectively. The TEM studies revealed the almost spherical nature of LID SLN and NLC formulations. The XRD and DSC studies of LID SLN suggested amorphization of drug in the carrier system. The SLN formulation was stable with respect to particle size, polydispersity, and entrapment efficiency for 6 months at 40°C/75% relative humidity (RH). Negligible leakage was observed for the NLC formulation when stored for 1 month at 40°C/75% RH. In vitro permeation studies indicated that LID SLN gel and LID NLC gel significantly sustained the LID release compared to that of Xylocaine® gel. The in vivo efficacy results supported the results of the in vitro permeation studies wherein the LID SLN gel and LID NLC gel resulted in fivefold and sixfold increase in duration of anesthesia, respectively, compared to that of Xylocaine® gel.  相似文献   

4.
For a drug with low bioavailability, a matrix tablet with liquid permeation enhancer (Labrasol®) was formulated. Factorial design was used to evaluate the effect of three formulation factors: drug percentage, polymer type (Methocel® K100M or Eudragit® L 100-55), and tablet binder percentage (Plasdone® S-630) on tablet characteristics. Tablets were prepared by direct compression and characterized. Compressibility index values ranged between 15.90% and 29.87% and tablet hardness values from 7.8 to 29.78 Kp. Eudragit®-containing formulations had better compressibility index values with higher tablet hardness. Time for 75% of drug release (T 75) was calculated, and formulations containing Eudragit® L 100-55 had faster release rates than tablet formulations with Methocel® K100M. Formulations with Methocel® K100M fit well in the Higuchi model as indicated by their R 2 values (>0.98). Among all the formulation factors studied, polymer type displayed the highest and statistically significant effect on compressibility index, tablet hardness, and dissolution rate. Statistical design helped in better understanding the effect of formulation factors on tablet characteristics important for designing formulations with desired characteristics.  相似文献   

5.
Rapid endothelialization of cardiovascular stents is needed to reduce stent thrombosis and to avoid anti-platelet therapy which can reduce bleeding risk. The feasibility of using magnetic forces to capture and retain endothelial outgrowth cells (EOC) labeled with super paramagnetic iron oxide nanoparticles (SPION) has been shown previously. But this technique requires the development of a mechanically functional stent from a magnetic and biocompatible material followed by in-vitro and in-vivo testing to prove rapid endothelialization. We developed a weakly ferromagnetic stent from 2205 duplex stainless steel using computer aided design (CAD) and its design was further refined using finite element analysis (FEA). The final design of the stent exhibited a principal strain below the fracture limit of the material during mechanical crimping and expansion. One hundred stents were manufactured and a subset of them was used for mechanical testing, retained magnetic field measurements, in-vitro cell capture studies, and in-vivo implantation studies. Ten stents were tested for deployment to verify if they sustained crimping and expansion cycle without failure. Another 10 stents were magnetized using a strong neodymium magnet and their retained magnetic field was measured. The stents showed that the retained magnetism was sufficient to capture SPION-labeled EOC in our in-vitro studies. SPION-labeled EOC capture and retention was verified in large animal models by implanting 1 magnetized stent and 1 non-magnetized control stent in each of 4 pigs. The stented arteries were explanted after 7 days and analyzed histologically. The weakly magnetic stents developed in this study were capable of attracting and retaining SPION-labeled endothelial cells which can promote rapid healing.  相似文献   

6.
Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.  相似文献   

7.
Modelling flow-diverting (FD) stents as porous media (PM) markedly improves the efficiency of computational fluid dynamics (CFD) simulations in the study of intracranial aneurysm treatment. Nonetheless, the parameters of PM models adopted for simulations up until now were rarely calibrated to match the represented FD structure. We therefore sought to evaluate the PM parameters for a representative variety of commercially available stents, so characterising the flow-diversion behaviours of different FD devices on the market.We generated fully-resolved geometries for treatments using PED, Silk+, FRED, and dual PED stents. We then correspondingly derived the calibrated PM parameters—permeability (k) and inertial resistance factor (C2)—for each stent design from CFD simulations, to ensure the calibrated PM model has identical flow resistance to the FD stent it represents. With each of the calibrated PM models respectively deployed in two aneurysms, we studied the flow-diversion effects of these stent configurations.This work for the first time reported several sets of parameters for PM models, which is vital to address the current knowledge gap and rectify the errors in PM model simulations, thereby setting right the modelling protocol for future studies using PM models. The flow resistance parameters were strongly affected by porosity and effective thickness of the commercial stents, and thus accounted for in the PM models. Flow simulations using the PM stent models revealed differences in aneurysmal mass flowrate (MFR) and energy loss (EL) between various stent designs.This study improves the practicability of FD simulation by using calibrated PM models, providing an individualised method with improved simulation efficiency and accuracy.  相似文献   

8.
The aim of this study was to formulate and characterize Eudragit® L100 and Eudragit® L100-poly(lactic-co-glycolic acid) (PLGA) nanoparticles containing diclofenac sodium. Diclofenac generates severe adverse effects with risks of toxicity. Thus, nanoparticles were prepared to reduce these drawbacks in the present study. These nanoparticles were evaluated for surface morphology, particle size and size distribution, percentage drug entrapment, and in vitro drug release in pH 6.8. The prepared nanoparticles were almost spherical in shape, as determined by atomic force microscopy. The nanoparticles with varied size (241–274 nm) and 25.8–62% of entrapment efficiency were obtained. The nanoparticles formulations produced the release profiles with an initial burst effect in which diclofenac sodium release ranged between 38% and 47% within 4 h. The extent of drug release from Eudragit® L100 nanoparticles was up to 92% at 12 h. However, Eudragit®/PLGA nanoparticles showed an initial burst release followed by a slower sustained release. The cumulative release at 72 h was 56%, 69%, and 81% for Eudragit®/PLGA (20:80), Eudragit®/PLGA (30:70) and Eudragit®/PLGA (50:50) nanoparticles, respectively. The release profiles and encapsulation efficiencies depended on the amount of Eudragit in the blend. These data demonstrated the efficacy of these nanoparticles in sustaining the diclofenac sodium release profile.  相似文献   

9.
In this paper, starting from a consistent mathematical model, a novel computational approach is proposed for assessing some biomechanical effects on drug release from coronary drug-eluting stents (DESs), related to tissue properties, local hemodynamics and stent design. A multiscale and multidomain advection–diffusion model is formulated for describing drug dynamics in the polymeric substrate covering the stent, into the arterial wall, and in the vessel lumen. The model accounts for tissue microstructure (anisotropic drug diffusion, porosity, drug retention induced by resident proteins), macrostructure (plaque between stent and tissue), and local hemodynamics. In the case of hydrophobic taxus-based compounds, several numerical analyses have been carried out on simplified geometries by using finite element simulations, performing significant comparisons with other recent studies and highlighting general conclusions for assessing effectiveness of some modelling features as well as useful hints for optimizing drug delivery design and technology.  相似文献   

10.
Stent thrombosis is a major complication of coronary stent and scaffold intervention. While often unanticipated and lethal, its incidence is low making mechanistic examination difficult through clinical investigation alone. Thus, throughout the technological advancement of these devices, experimental models have been indispensable in furthering our understanding of device safety and efficacy. As we refine model systems to gain deeper insight into adverse events, it is equally important that we continue to refine our measurement methods. We used digital signal processing in an established flow loop model to investigate local flow effects due to geometric stent features and ultimately its relationship to thrombus formation. A new metric of clot distribution on each microCT slice termed normalized clot ratio was defined to quantify this distribution. Three under expanded coronary bare-metal stents were run in a flow loop model to induce clotting. Samples were then scanned in a MicroCT machine and digital signal processing methods applied to analyze geometric stent conformation and spatial clot formation. Results indicated that geometric stent features play a significant role in clotting patterns, specifically at a frequency of 0.6225 Hz corresponding to a geometric distance of 1.606 mm. The magnitude-squared coherence between geometric features and clot distribution was greater than 0.4 in all samples. In stents with poor wall apposition, ranging from 0.27 mm to 0.64 mm maximum malapposition (model of real-world heterogeneity), clots were found to have formed in between stent struts rather than directly adjacent to struts. This early work shows how the combination of tools in the areas of image processing and signal analysis can advance the resolution at which we are able to define thrombotic mechanisms in in vitro models, and ultimately, gain further insight into clinical performance.  相似文献   

11.
Materials that permit control over the release of DNA from the surfaces of topologically complex implantable devices, such as intravascular stents, could contribute to the development of new approaches to the localized delivery of DNA. We report the fabrication of ultrathin, multilayered polyelectrolyte films that permit both the immobilization and controlled release of plasmid DNA from the surfaces of stainless steel intravascular stents. Our approach makes use of an aqueous-based, layer-by-layer method for the assembly of nanostructured thin films consisting of alternating layers of plasmid DNA and a hydrolytically degradable polyamine. Characterization of coated stents using scanning electron microscopy (SEM) demonstrated that stents were coated uniformly with an ultrathin film ca. 120 nm thick that adhered conformally to the surfaces of stent struts. These ultrathin films did not crack, peel, or delaminate substantially from the surface after exposure to a range of mechanical challenges representative of those encountered during stent deployment (e.g., balloon expansion). Stents coated with eight bilayers of degradable polyamine and a plasmid encoding enhanced green fluorescent protein (EGFP) sustained the release of DNA into solution for up to four days when incubated in phosphate buffered saline at 37 degrees C, and coated stents were capable of mediating the expression of EGFP in a mammalian cell line without the aid of additional transfection agents. The approach reported here could, with further development, contribute to the development of localized gene-based approaches to the treatment of cardiovascular diseases or related conditions.  相似文献   

12.
Gene delivery from a DNA controlled-release stent in porcine coronary arteries   总被引:20,自引:0,他引:20  
Expandable intra-arterial stents are widely used for treating coronary disease. We hypothesized that local gene delivery could be achieved with the controlled release of DNA from a polymer coating on an expandable stent. Our paper reports the first successful transfection in vivo using a DNA controlled-release stent. Green fluorescent protein (GFP) plasmid DNA within emulsion-coated stents was efficiently expressed in cell cultures (7.9% +/- 0.7% vs. 0.6% +/- 0.2% control, p < 0.001) of rat aortic smooth muscle cells. In a series of pig stent-angioplasty studies, GFP expression was observed in all coronary arteries (normal, nondiseased) in the DNA-treated group, but not in control arteries. GFP plasmid DNA in the arterial wall was confirmed by PCR, and GFP presence in the pig coronaries was confirmed by immunohistochemistry. Thus, DNA-eluting stents are capable of arterial transfection, and could be useful as delivery systems for candidate vectors for gene therapy of cardiovascular diseases.  相似文献   

13.
Bacterial colonization of biliary stents is one of the driving forces behind sludge formation which may result in stent occlusion. Major focus of the study was to analyze the spectrum and number of microorganisms in relation to the indwelling time of stents and the risk factors for sludge formation. 343 stents were sonicated to optimize the bacterial release from the biofilm and identified by matrix-associated laser desorption/ionization-time of flight mass spectrometer (MALDI-TOF). 2283 bacteria were analyzed in total. The most prevalent microorganisms were Enterococcus species (spp.) (504;22%), followed by Klebsiella spp. (218;10%) and Candida spp. (188;8%). Colonization of the stents mainly began with aerobic gram-positive bacteria (43/49;88%) and Candida spp. (25/49;51%), whereas stents with an indwelling time>60 days(d) showed an almost equal colonization rate by aerobic gram-negative (176/184;96%) and aerobic gram-positive bacteria (183/184;99%) and a high proportion of anaerobes (127/184;69%). Compared to stents without sludge, more Clostridium spp. [(P = 0.02; Odds Ratio (OR): 2.4; 95% confidence interval (95%CI): (1.1–4.9)]) and Staphylococcus spp. [(P = 0.03; OR (95%CI): 4.3 (1.1–16.5)] were cultured from stents with sludge. Multivariate analysis revealed a significant relationship between the number of microorganisms [P<0.01; OR (95%CI): 1.3(1.1–1.5)], the indwelling time [P<0.01; 1–15 d vs. 20–59 d: OR (95%CI): 5.6(1.4–22), 1–15 d vs. 60–3087 d: OR (95% CI): 9.5(2.5–35.7)], the presence of sideholes [P<0.01; OR (95%CI): 3.5(1.6–7.9)] and the occurrence of sludge. Stent occlusion was found in 70/343(20%) stents. In 35% of cases, stent occlusion resulted in a cholangitis or cholestasis. In conclusion, microbial colonization of the stents changed with the indwelling time. Sludge was associated with an altered spectrum and an increasing number of microorganisms, a long indwelling time and the presence of sideholes. Interestingly, stent occlusion did not necessarily lead to a symptomatic biliary obstruction.  相似文献   

14.
Esophageal cancer (EC) mostly affects the elderly population and is frequently diagnosed at an advanced stage. Self-expanding metal stents (SEMS) are the most popular mode of palliation, but they are associated with reocclusion caused by tumor growth. To overcome this problem, docetaxel (DTX)-loaded polyurethane formulations were prepared for stent application. The films were evaluated against the cancer cell lines, OE-19 and OE-21, and normal esophageal cell line Het-1A. The DTX and the formulations were evaluated in vitro for the cytotoxicity and in vivo in nude mice. It was found that DTX and the formulations have a weak activity against the EC cell lines and an even weaker activity against Het-1A cell line. Preliminary in vivo studies showed skin toxicity in nude mice necessitating modification of the formulation. Reevaluation in a mouse xenograft model resulted in toxicity at high dose formulations while the low dose formulation exhibited modest advantage over commercial IV formulation; however, there was no significant difference between the commercial IV and blank formulation. DTX combination with an anti-cancer agent having complementary mode of action and non-overlapping toxicity could yield better outcome in future.  相似文献   

15.
A method to correct stent related complications non-invasively, is the local delivery of therapeutic agents. Different drugs have been delivered on stents, after being either dispersed or encapsulated in polymeric materials, and placed on stents to form drug-eluting-stents (DE-stents). Investigation of possibility to cover polymer - coated metallic stents, with liposomal drugs, for preparation of novel DE-liposome-coated-stents, has been initiated few years ago. In this context our research has been focused on answering the following questions: (i) Can liposomes be applied as coatings on polymer covered stents? (ii) Can drug release from liposome coated-stents be controlled? And: (iii) how is haemo-compatibility of stents affected? The results of the experiments carried out demonstrate that liposomal formulations of drugs can be used as coating systems of polymer covered stents for achieving sustained release of drugs at the site of interest. By modifying liposome characteristics, different amounts of drugs may be placed on the stents and their release rates can be adjusted for maximum therapeutic benefit. Finally, haemocompatibility of stents is highly improved (mainly in terms of cell adhesion and activation of coagulation system), when stents are coated with heparin-encapsulating -DRV liposomes.  相似文献   

16.
The reduction in plaque volume during stent implantation is associated with the release of particulate debris and plaque-derived soluble substances. We studied the potential release of the proinflammatory cytokine TNF-alpha into the coronary circulation and whether such release is related to the reduction in plaque volume and, possibly, a predictor for restenosis. In 18 male patients (n = 24 stents) with severe stenosis in a saphenous vein aortocoronary bypass graft (SVG), we used a distal balloon occlusion-aspiration device during stent implantation. The aspirate TNF-alpha levels were determined before and after stent implantation and related to the angiographic and intravascular ultrasound-assessed severity of stenosis and restenosis. We found that TNF-alpha is, indeed, released into the aspirate of stented SVG (9 +/- 1 and 28 +/- 3 pg/ml before and after stent implantation, respectively, P < 0.0001) and that such release is related to the reduction in plaque volume (r = 0.88, P < 0.0001) and associated with restenosis after 5 mo (r = 0.71, P = 0.001). The periprocedural release of plaque-derived TNF-alpha possibly represents the amount and activity of the atherosclerotic process and might be a predictor for restenosis.  相似文献   

17.
Based on the enhancement of fluorescein isothiocyanate (FITC) fluorescence caused by reactions between proteins, we developed a reagentless, regenerable and rapid immunosensing system to determine immunoglobulin G (IgG). Fluorescence intensity of the immobilized FITC depends on IgG concentration, ranging from 10 to 50 microg/ml, specifically, even with co-existing proteins. The response time is 30 min during steady-state measurement and is less than a minute during transient measurement. When the FITC-labeled protein A binds to IgG, the surrounding atmosphere of FITC becomes hydrophobic. Since the fluorescence intensity of fluorescent substances generally increases at a hydrophobic environment, FITC fluorescence intensity increases with the concentration of protein A bonding to IgG. This system is regenerable because the fluorescence enhancement repeatedly occurs every time the immobilized fluorescent reagent is immersed in sample solutions.  相似文献   

18.
The aim of this work was to statistically optimize a novel high-dose, mesalazine colonic delivery matrix system, potentially suitable for once daily administration, using simple wet granulation method. A hydrophobic–hydrophilic polymeric blend was used to manipulate drug release. A three-factor, three-level Box–Behnken design was used to construct polynomial models correlating the dependent and independent variables. Independent formulation variables were the percentages of the hydrophilic polymer Carbopol® 940, hydrophobic polymer Eudragit® RS, and the superdisintegrant croscarmellose sodium. The cumulative percentages of drug released at 6, 10, and 14 h were selected as dependent variables and restricted to 7.5–22.5% (Y 1), 42.5–57.5 % (Y 2), and 72.5–87.5% (Y 3), respectively. A second-order polynomial equation fitted to the data was used to optimize the independent formulation variables. Based on Box–Behnken experimental design, different mesalazine release profiles were obtained. The optimized formulation containing 5.72% Carbopol®, 9.77% Eudragit® RS, and 1.45% croscarmellose sodium was prepared according to the software determined levels. It provided a release profile which was very close to the targeted release profile, where the calculated values of f 1 and f 2 were 8.47 and 67.70, respectively, and followed zero-order release kinetics.  相似文献   

19.
Jojoba oil-based emulgel formulations were prepared using different concentrations of various gelling agents, such as hydroxypropyl methylcellulose (HPMC) and Carbopol 934 P and combination of both. The prepared emulgels were physically evaluated for their stability after temperature cycle test, centrifugation and long-term shelf storage for 1 year at room temperature. The in vitro release at 37°C was studied to define the effect of the concentration and type of the gelling agent. A comparison between the formulated emulgels and two commercially available products, Candistan® and Canesten® creams, was carried out to judge their efficacy and stability. The prepared emulgels exhibited non-Newtonian shear thinning behavior with little or no thixotropy. Four emulgels showed excellent stability as they demonstrated consistent rheological model under different treatment conditions. The in vitro release test showed variation in the extent of percent drug released. The drug release from the commercial preparation was lower than some of the prepared emulgel formulae. One formula containing combination of the two gelling agents (HPMC and Carbopol 934 P), showed excellent stability and high extent of clotrimazole release was microbiologically evaluated against Candida albicans using cylinder and plate method. The selected formula showed superior antimycotic activity compared to the commercially available formulation. Further in vivo animal studies for the obtained stable formula is recommended.  相似文献   

20.
Intravascular brachytherapy (IVBT) has rapidly gained acceptance as a new treatment modality for reducing restenosis and improving the success rate of percutaneous transluminal coronary angioplasty (PTCA). Recent clinical results on patients treated with beta-emitting 32P stents suggest that radiation reduces in-stent restenosis but may exacerbate neointimal growth at the edges of the stents. This has been referred to as the "candy wrapper effect." It is well known that radioactive stents yield extremely inhomogeneous dose distributions, with low doses delivered to tissues in between stent struts, at the ends of the stent, and also at depth. Some animal model studies suggest that low doses of radiation may stimulate rather than inhibit neointimal growth in an injured vessel, and it is hypothesized that dose inhomogeneity at the ends of a stent may contribute to the candy wrapper effect. We present here a theoretical study comparing dose distributions for beta stents vs. gamma stents; "dumbbell" radioactive loaded stents vs. uniformly loaded stents; and stents with alternate strut design. Calculations demonstrate that dose inhomogenieties between stent struts, at the ends of stents, and at depth can be reduced by better stent design and isotope selection. Prior to the introduction of radioactive stents, criteria for stent design included factors such as trackability, flexibility, strength, etc. We show here that if stent design also includes criteria for strut shape and spacing that improved dose distributions are possible, which in turn could reduce the candy wrapper effect.  相似文献   