首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
FAST slides: a novel surface for microarrays   总被引:3,自引:0,他引:3  
We have evaluated FAST slides, a glass slide with a microporous polymeric surface that is a suitable substrate for microarray technology. The surface is a nitrocellulose-based polymer that binds DNA and proteins in a noncovalent but irreversible manner. FAST slides are compatible with robotic systems currently used to create microarrays and can easily accommodate volumes of 0.03-2 nL/spot. Our data indicate that FAST slides have a much higher binding capacity for DNA and better spot-to-spot consistency than traditional poly-lysine-coated slides. In addition, FAST slides are well suited for fluorescent detection because of their relatively low light scatter and efficient retention of arrayed DNA. These properties translate into fluorescent sensitivity comparable to modified glass surfaces. FAST slides are also ideal for arraying proteins, making them the only substrate of their kind currently available for microarray applications.  相似文献   

2.
The early applications of microarrays and detection technologies have been centered on DNA-based applications. The application of array technologies to proteomics is now occurring at a rapid rate. Numerous researchers have begun to develop technologies for the creation of microarrays of protein-based screening tools. The stability of antibody molecules when bound to surfaces has made antibody arrays a starting point for proteomic microarray technology. To minimize disadvantages due to size and availability, some researchers have instead opted for antibody fragments, antibody mimics or phage display technology to create libraries for protein chips. Even further removed from antibodies are libraries of aptamers, which are single-stranded oligonucleotides that express high affinity for protein molecules. A variation on the theme of protein chips arrayed with antibody mimics or other protein capture ligand is that of affinity MS where the protein chips are directly placed in a mass spectrometer for detection. Other approaches include the creation of intact protein microarrays directly on glass slides or chips. Although many of the proteins may likely be denatured, successful screening has been demonstrated. The investigation of protein-protein interactions has formed the basis of a technique called yeast two-hybrid. In this method, yeast "bait" proteins can be probed with other yeast "prey" proteins fused to DNA binding domains. Although the current interpretation of protein arrays emphasizes microarray grids of proteins or ligands on glass slides or chips, 2-D gels are technically macroarrays of authentic proteins. In an innovative departure from the traditional concept of protein chips, some researchers are implementing microfluidic printing of arrayed chemistries on individual protein spots blotted onto membranes. Other researchers are using in-jet printing technology to create protein microarrays on chips. The rapid growth of proteomics and the active climate for new technology is driving a new generation of companies and academic efforts that are developing novel protein microarray techniques for the future.  相似文献   

3.
Screening of biochemical interactions becomes simpler, less expensive, and more accurate when labels, such as fluorescent dyes, radioactive markers, and colorimetric reactions, are not required to quantify detected material. SRU Biosystems has developed a biosensor technology that is manufactured on continuous sheets of plastic film and incorporated into standard microplates and microarray slides to enable label-free assays to be performed with high throughput, high sensitivity, and low cost per assay. The biosensor incorporates a narrow band guided-mode resonance reflectance filter, in which the reflected color is modulated by the attachment/detachment of biochemical material to the surface. The technology offers 4 orders of linear dynamic range and uniformity within a plate, with a coefficient of variation of 2.5%. Using conventional biochemical immobilization surface chemistries, a wide range of assay applications are enabled. Small molecule screening, cell proliferation/cytotoxicity, enzyme activity screening, protein-protein interaction, and cell membrane receptor expression are among the applications demonstrated.  相似文献   

4.
Evaluation of surface chemistries for antibody microarrays   总被引:1,自引:1,他引:0  
Antibody microarrays are an emerging technology that promises to be a powerful tool for the detection of disease biomarkers. The current technology for protein microarrays has been derived primarily from DNA microarrays and is not fully characterized for use with proteins. For example, there are a myriad of surface chemistries that are commercially available for antibody microarrays, but there are no rigorous studies that compare these different surfaces. Therefore, we have used a sandwich enzyme-linked immunosorbent assay (ELISA) microarray platform to analyze 17 different commercially available slide types. Full standard curves were generated for 23 different assays. We found that this approach provides a rigorous and quantitative system for comparing the different slide types based on spot size and morphology, slide noise, spot background, lower limit of detection, and reproducibility. These studies demonstrate that the properties of the slide surface affect the activity of immobilized antibodies and the quality of data produced. Although many slide types produce useful data, glass slides coated with aldehyde silane, poly-l-lysine, or aminosilane (with or without activation with a crosslinker) consistently produce superior results in the sandwich ELISA microarray analyses we performed.  相似文献   

5.
A rapid and accurate detection of molecular binding of antigen-antibody signaling in high throughput is of great importance for biosensing technology. We proposed a novel optical biochip with multichannels for the purpose of detection of biotin–streptavidin on the basis of localized surface plasmon resonance. The optical biochip was fabricated using photolithography to form the microarrays functioning with multichannels on glass substrate. There are different nanostructures in each microarray. Dry etching and nanosphere lithography techniques were applied to fabricate Ag nanostructures such as hemispheres, nanocylindricals, triangular, and rhombic nanostructures. We demonstrated that 100-nM target molecule (streptavidin) on these optical biochips can be easily detected by a UV-visible spectrometer. It indicated that period and shape of the nanostructures significantly affect the optical performance of the nanostructures with different shapes and geometrical parameters. Our experimental results demonstrated that the optical biochips with the multichannels can detect the target molecule using the microarrays structured with different shapes and periods simultaneously. Batch processing of immunoassay for different biomolecular through the different channels embedded on the same chip can be realized accordingly.  相似文献   

6.
We demonstrate the accurate picoliter-scale dispensing of active proteins using a novel laser transfer technique. Droplets of protein solution are dispensed onto functionalized glass slides and into plastic microwells, activating as small as 50-microm diameter areas on these surfaces. Protein microarrays fabricated by laser transfer were assayed using standard fluorescent labeling techniques to demonstrate successful protein and antigen binding. These results indicate that laser transfer does not damage the active site of the dispensed protein and that this technique can be used to successfully fabricate a functioning protein microarray. Also, as a result of the efficient nature of the process, material usage is reduced by two to four orders of magnitude compared to conventional pin dispensing methods for protein spotting.  相似文献   

7.
Today, microarray fluorescence detection is still limited because a great proportion of hybrids remain undetectable. In this paper we describe sol-gel optical multilayers (stacks of low- and high-index layers) deposited on glass slides which increase the fluorescence of DNA microarrays and favour the detection of fluorescent targets. An alternative to the expensive and time-consuming physical vapour deposition technology is proposed. It is a low-cost sol-gel coating of glass slides, each layer being made by "dipping" (alternatively in SiO2 or TiO2 solutions), "draining and drying". After the selection of the best surface layer of the substrates, the multilayer mirrors modelled for one (Cy3) or two (Cy3 and Cy5) fluorophores are spotted with a series of Yeast probes and compared to similar microarrays on standard glass slides through hybridisation experiments. The fluorescence images of the mirrors show increased signals for all the probes. The enhancement factors determined for Cy3 and for Cy3/Cy5 mirrors (10-12 and 4-5, respectively) are consistent with the initial modelling. This allows the assessment of the basal expression levels of Yeast low-expressed genes. Moreover, these substrates show a noticeable increase in sensitivity for induction/repression ratio measurements in differential gene expression experiments. So, they could be considered as promising tools for the analysis of small biological samples.  相似文献   

8.
Zhou X  Zhou J 《Proteomics》2006,6(5):1415-1426
We report here the development and characterization of protein microarrays fabricated on nanoengineered 3-D polyelectrolyte thin films (PET) deposited on glass slide by consecutive adsorption of polyelectrolytes via self-assembly technique. Antibodies or antigens were immobilized in the PET-coated glass slides by electrostatic adsorption and entrapment of porous structure of the 3-D polymer film and thus establishing a platform for parallel analysis. Both antigen and antibody microarrays were fabricated on the PET-coated slides, and direct and indirect immunoassays on protein microarrays for multiple-analyte detection were demonstrated. Microarrays produced on these PET-coated slides have consistent spot morphology and provide performance features needed for proteomic analysis. The protein microarrays on the PET films provide LOD as low as 6 pg/mL and dynamic ranges up to three orders of magnitude, which are wider than the protein microarrays fabricated on aldehyde and poly-L-lysine functionalized slides. The PET films constructed by self-assembly technique in aqueous solution is green chemistry based, cost-effective method to generate 3-D thin film coatings on glass surface, and the coated slide is well suited for immobilizing many types of biological molecules so that a wide variety of microarray formats can be developed on this type of slide.  相似文献   

9.
Robust and efficient synthetic method for forming DNA microarrays   总被引:6,自引:3,他引:6       下载免费PDF全文
The field of DNA microarray technology has necessitated the cooperative efforts of interdisciplinary scientific teams to achieve its primary goal of rapidly measuring global gene expression patterns. A collaborative effort was established to produce a chemically reactive surface on glass slide substrates to which unmodified DNA will covalently bind for improvement of cDNA microarray technology. Using the p-aminophenyl trimethoxysilane (ATMS)/diazotization chemistry that was developed, microarrays were fabricated and analyzed. This immobilization method produced uniform spots containing equivalent or greater amounts of DNA than commercially available immobilization techniques. In addition, hybridization analyses of microarrays made with ATMS/diazotization chemistry showed very sensitive detection of the target sequence, two to three orders of magnitude more sensitive than the commercial chemistries. Repeated stripping and re-hybridization of these slides showed that DNA loss was minimal, allowing multiple rounds of hybridization. Thus, the ATMS/diazotization chemistry facilitated covalent binding of unmodified DNA, and the reusable microarrays that were produced showed enhanced levels of hybridization and very low background fluorescence.  相似文献   

10.
We describe in this paper the preparation and characterization of semicarbazide glass slides and their use for the fabrication of microarrays using site-specific alpha-oxo semicarbazone ligation. The functional density and homogeneity of the semicarbazide glass slides were optimized by analyzing the reactivity of the layer toward a synthetic glyoxylyl fluorescent probe. Oligonucleotide microarrays were prepared by site-specific immobilization of glyoxylyl oligodeoxynucleotides. The slides were directly used in the hybridization assays using fluorescence detection and displayed a significant gain in sensibility as compared to the aldehyde glass slide/amino oligodeoxynucleotide chemistry. Semicarbazide slides were also used for the immobilization of a biotinylated peptide alpha-oxo aldehyde. The peptide microarrays allowed model interaction studies with streptavidin or an anti-biotin antibody.  相似文献   

11.
A new polymeric coating for protein microarrays   总被引:3,自引:0,他引:3  
Despite the increasing interest in arraying proteins in a high-density format, several technical issues still impede the development of protein microarray technology. One of the major problems is the availability of substrates that are able to bind native proteins with high density. In this study, we investigated the suitability of a novel surface as a support for protein microarrays. A polymeric glass coating is obtained by physical adsorption of a N,N-dimethylacrylamide (DMA), N,N-acryloyloxysuccinimide (NAS), and [3-(methacryloyl-oxy)propyl]trimethoxysilyl (MAPS) copolymer. The coating procedure provides a fast and inexpensive method of producing hydrophilic functional surfaces. The slide performance was investigated in a protein-protein interaction experiment and in the assessment of rheumatoid factor (RF) in human serum samples. The results demonstrate that the ligands immobilized on the polymeric surface maintain an active conformation and are easily accessible, providing a detection limit of 54amol/spot. Moreover, in the RF assay, after hybridization with the sera, the slides have a low background, leading to a detection limit of 900amol/spot.  相似文献   

12.

Background  

The antibody microarray technique is a newly emerging proteomics tool for differential protein expression analyses that uses fluorescent dyes Cy 3 and Cy 5. Environmental factors, such as light exposure, can affect the signal intensity of fluorescent dyes on microarray slides thus, it is logical to scan microarray slides immediately after the final wash and drying processes. However, no research data are available concerning time-dependent changes of fluorescent signals on antibody microarray slides to this date. In the present study, microarray slides were preserved at -20°C after regular microarray experiments and were rescanned at day 10, 20 and 30 to evaluate change in signal intensity.  相似文献   

13.
Single-molecule fluorescence spectroscopy has proven to be instrumental in understanding a wide range of biological phenomena at the nanoscale. Important examples of what this technique can yield to biological sciences are the mechanistic insights on protein-protein and protein-nucleic acid interactions. When interactions of proteins are probed at the single-molecule level, the proteins or their substrates are often immobilized on a glass surface, which allows for a long-term observation. This immobilization scheme may introduce unwanted surface artifacts. Therefore, it is essential to passivate the glass surface to make it inert. Surface coating using polyethylene glycol (PEG) stands out for its high performance in preventing proteins from non-specifically interacting with a glass surface. However, the polymer coating procedure is difficult, due to the complication arising from a series of surface treatments and the stringent requirement that a surface needs to be free of any fluorescent molecules at the end of the procedure. Here, we provide a robust protocol with step-by-step instructions. It covers surface cleaning including piranha etching, surface functionalization with amine groups, and finally PEG coating. To obtain a high density of a PEG layer, we introduce a new strategy of treating the surface with PEG molecules over two rounds, which remarkably improves the quality of passivation. We provide representative results as well as practical advice for each critical step so that anyone can achieve the high quality surface passivation.  相似文献   

14.
Dufva M  Petronis S  Jensen LB  Krag C  Christensen CB 《BioTechniques》2004,37(2):286-92, 294, 296
An agarose film has been proposed as an efficient substrate for producing microarrays. The original film preparation procedure was simplified significantly by grafting the agarose layer directly onto unmodified microscope glass slides instead of aminated glass slides, and the blocking procedure was replaced with a wash in 0.1x standard saline citrate (SSC) and 0.5% sodium dodecyl sulfate (SDS) without decreasing the performance of the produced microarrays. Characterization of the grafted agarose film using atomic force microscopy (AFM) and scanning electron microscopy (SEM) showed that the agarose film had a 10-fold increase in surface roughness compared to glass and that the interior of the agarose film was porous, with pore sizes between 100-500 nm. A comparison of hybridization on aldehyde-activated agarose-coated microarray slides and commercial amino-reactive microarray slides showed that aldehyde-activated agarose-coated slides had the highest signal-to-noise ratio of 850, suggesting that the aldehyde-activated agarose microarray slides are suitable in applications where analytes have a wide concentration range. By immobilizing the DNA probes using ultraviolet (UV) light, the signal-to-noise ratio was further increased to 3000 on the agarose microarray slides. The specificity of the UV cross-linked DNA probes was demonstrated using 21 and 25 bp long capture probes, enabling discrimination of target molecules differing in only one base.  相似文献   

15.
To explore the application of DNA chip technology for the detection and typing of Human Papillomavirus (HPV), the HPV6, 11, 16 and 18 gene fragments were isolated and printed onto aminosilane-coated glass slides by a PixSys 5500 microarrayer as probes to prepare the HPV gene chips. HPV samples, after being labeled with fluorescent dye by restriction display PCR (RD-PCR) technology, were hybridized with the microarray, which was followed by scanning and analysis. The experimental condition for preparing the HPV gene chips was investigated, and the possibility of HPV genotyping using gene chips was discussed. The technique that was established in this study for preparing HPV gene chips is practical. The results of the present study demonstrated the versatility and inspiring prospect of using this technology to detect and genotype HPV.  相似文献   

16.
We used electron-beam lithography to fabricate chemical nanostructures, i.e. amino groups in aromatic self-assembled monolayers (SAMs) on gold surfaces. The amino groups are utilized as reactive species for mild covalent attachment of fluorescently labeled proteins. Since non-radiative energy transfer results in strong quenching of fluorescent dyes in the vicinity of the metal surfaces, different labeling strategies were investigated. Spacers of varying length were introduced between the gold surface and the fluorescently labeled proteins. First, streptavidin was directly coupled to the amino groups of the SAMs via a glutaraldehyde linker and fluorescently labeled biotin (X-Biotin) was added, resulting in a distance of approximately 2 nm between the dyes and the surface. Scanning confocal fluorescence images show that efficient energy transfer from the dye to the surface occurs, which is reflected in poor signal-to-background (S/B) ratios of approximately 1. Coupling of a second streptavidin layer increases the S/B-ratio only slightly to approximately 2. The S/B-ratio of the fluorescence signals could be further increased to approximately 4 by coupling of an additional fluorescently labeled antibody layer. Finally, we introduced tetraethylenepentamine as functional spacer molecule to diminish fluorescence quenching by the surface. We demonstrate that the use of this spacer in combination with multiple antibody layers enables the controlled fabrication of highly fluorescent three-dimensional nanostructures with S/B-ratios of >20. The presented technique might be used advantageously for the controlled three-dimensional immobilization of single protein or DNA molecules and the well-defined assembly of protein complexes.  相似文献   

17.
Microarray technology has brought a paradigmatic change in bioanalytics. However, highly sensitive and accurate assays are still needed for a real breakthrough. We present a simple and generic approach for fluorescent signal amplification with fluorescent microparticle labels. The assay principle was demonstrated using a reverse array model consisting of spots of bovine serum albumin with a small fraction of the proteins biotinylated. Specific binding of streptavidin coated fluorescent microparticles to the spots was promoted by applying a controlled continuous microparticle flow. The surface bound beads were visualized and quantified with confocal microscopy images. Comparison with standard fluorescent and flow discrimination assays has revealed several advantages of our approach. First, non-specific particle binding could be reduced to less than 1 particle/spot making therefore the visualization of single biomolecular bonds possible. Second, the amplification scheme presented here is generic and can be applied to any fluorescent microarray. Furthermore, this assay makes use of a biotin-streptavidin linkage and can therefore be applied to all kind of assays. Finally, single fluorescent microbeads can be easily visualized with standard optical equipments, so that no high performance equipment is required.  相似文献   

18.
Optical inteference (OI) coated slides with unique optical properties were utilized in microarray analyses, demonstrating their enhanced detection sensitivity over traditional microarray substrates. The OI coating is comprised of a proprietary multilayered, dielectric, thin-film interference coating located beneath the functional coating (aminosilane or epoxysilane). It is designed to enhance the fluorescence in the Cy3 and Cy5 channel by increasing the light absorption of the dyes by about 6-fold and by redirecting emitted fluorescence into the detector during scanning, resulting in a theoretical limit of about 12-fold signal amplification. Two-color DNA microarray experiments conducted on the OI slides showed over 8-fold signal amplification, conservation of gene expression ratios, and increased signal-to-noise ratio when compared to control slides, indicating enhanced detection sensitivity. Protein microarray assays also exhibited over 8-fold signal amplification at three different target concentrations, demonstrating the versatility of the OI slides for different microarray applications. Further, the DNA and protein assays performed on the OI slides exhibited excellent detection sensitivity even at the low target amounts essential for diagnostic applications. The OI slides are compatible with commonly used protocols, printers, scanners and other microarray equipment. Therefore, the OI slides offer an attractive alternative to traditional microarray substrates, where enhanced detection sensitivity is desired.  相似文献   

19.
Sun J  Graeter SV  Yu L  Duan S  Spatz JP  Ding J 《Biomacromolecules》2008,9(10):2569-2572
A microtransfer technique for micropattern fabrication using a dithiol macromolecular linker is suggested by transferring a conventionally photolithography-prepared gold microarray on a hard inorganic substrate to a polymeric substrate. The linker was synthesized by end-capping a poly(ethylene glycol) (PEG) chain by the thiol groups. The efficiency of this technique is demonstrated by the transfer of gold microdots from glass to a cell-adhesion-resistant PEG hydrogel, which was formed by polymerizing PEG diacrylate macromers. The stability and biocompatibility of the resulting polymeric-inorganic hybrid material and cell-adhesion contrast of the patterned surface is confirmed by preliminary cell experiments.  相似文献   

20.
With the advent of protein and antibody microarray technology several different coatings and protocols have been published, which may be broadly divided into two types: gel-coated surfaces and plain non-gel-coated glass or plastic surfaces, some with chemical groups attached. We have screened 11 different array surfaces of both types and compared them with respect to their detection limit, inter- and intrachip variation, and storage characteristics. Five different antibodies were immobilized onto each type of microarray support, with total protein concentrations ranging from 40 fmol to 25 amol per spot. From these results, it was seen that some antibodies were more suited for use on antibody arrays. All measurements were performed in quadruplicate, and the results revealed high signal uniformity and reproducibility of most plain glass and plastic slides. Lower detection limits were obtained with polyacrylamide-coated slides, making them more suitable for the detection of very low concentrations of antigen. All microarray coatings could be stored for a period of 8 weeks; however, improved results were seen after 2 weeks of storage. In conclusion, the results indicate the need to test each antibody to be used on an antibody array and to select the microarray coating based on experimental requirements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号