首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
2.
A brief survey of the literature on manifestations of myo-electric fatigue has disclosed a surprisingly sharp conflict between early studies, focusing on neuromotor regulatory mechanisms, and more recent studies which stress the determinant influence of local metabolism and skewed homeostasis. Favoured explanations concerning changes in the electromyographic (EMG) spectrum were synchronization/grouping of motor unit (MU) firing and conduction velocity (CV) decreases of the action potential propagation. The notion of mutual exclusivity interwoven with these theories prompted us to reinvestigate the EMG of moderate level, static endurance contraction. Ten men in their twenties performed isometric elbow flexion (elbow angle 135°) at 30%6 maximal voluntary contraction (MVC), and the surface EMG of the brachioradialis (BR) and biceps brachii (BB) muscles was recorded. Initially the CV — determined by cross-correlation — was 4.3 m · s–1 (BR) and 4.6 m · s–1 (BB). At exhaustion the CV of the BR muscle had declined by 33%, roughly twice the decrease of the BB CV. Substantially larger relative median frequency (f m) reductions of 50% (BR) and 43% (BB) were found. Simultaneously, the root-mean-square amplitudes grew by 150% (BR) and 120% (BB). All changes during contraction reached the same level of significance (P<0.001, both muscles). From the largely uniform relative increases inf m and CV during the last 4 min of a 5-min recovery period, variations in CV were suggested to produce equivalent shifts inf m. The gradually increasing discrepancies between relative decreases inf m and CV during contraction presumably reflected centrally mediated regulation of MU firing patterns (notably synchronization). After the 5-min recovery another 11 endurance contractions at 30% MVC were executed, separated by 5-min intervals. The series of contractions reduced the endurance time to one-third of the 153 s initially sustained, while the terminal CV recordings increased by 1.0 (BR) and 0.6 (BB) m · s–1, and the terminalf m increased by 24 (BR) and 14 (BB) Hz. The relative CV decreased in direct proportion to the endurance time and thef m decreases varied with the CV; the findings did not support a causal link between CV decrease (signifying impaired fibre excitability) and the force failure of exhaustion.  相似文献   

3.
PURPOSE: Aim of this work is to compare mechanical and myoelectric manifestations of fatigue during an isometric contraction at 80% of maximal voluntary contraction (MVC) in a population of eight anorexic female patients (AN: 24.9+/-6.5 years, mean+/-SD) with respect to a group of seven healthy female subjects (CO: 30.0+/-6.6 years, mean+/-SD). METHODS: sEMG signals were recorded, using a linear electrode array (eight channels, 10mm apart), from vastus lateralis muscle of the dominant side. MVC, endurance time, initial value and rate of change of the EMG variables [conduction velocity (CV), mean power frequency (MNF), average rectified value (ARV)] were studied during the fatiguing contractions. RESULTS: Absolute and relative (normalized with respect to the body weight) knee torque values and endurance times were found not statistically different between the two groups. Similarly, EMG amplitude initial values and rate of change and MNF initial values were found not significantly different between the two groups. CV initial values and CV rate of change were found greater in healthy than in pathological subjects (AN CV: 3.74+/-0.86m/s, CO CV: 4.96+/-0.64m/s, p=0.004; AN CV rate of change: 0.006+/-0.015m/s2, CO CV rate of change: -0.006+/-0.007m/s2, p=0.006, mean+/-SD). Contrary to expectations MNF rate of changes in the AN group (-0.35+/-0.16Hz/s) was found greater than in the CO group (-0.17+/-0.13Hz/s, p=0.004, Mann-Whitney U test, mean+/-SD). CONCLUSIONS: CV values and their rate of change were compatible with a predominance of type I fibres (and/or with an hypotrophy of type II fibres) and/or with a lower sub-cutaneous tissue thickness with respect to CO group, as described in the literature with this pathology. The behaviour of MNF during sustained contractions, opposite to that of CV, suggests an altered central control strategy aimed to increase mechanical force output increasing the level of synchronization of motor units. This study confirms the capability of sEMG to assess muscle condition during severe malnutrition suggesting further studies to assess if sEMG can be used to monitor the effect of re-feeding and rehabilitation treatments.  相似文献   

4.
Isometric flexion of the right elbow at 15% of the maximal voluntary contraction (MVC) was maintained to the limit of endurance (elbow angle 135°). The surface electromyogram (EMG) of the brachioradialis (BR) and biceps brachii (BB) muscles was recorded for calculation of conduction velocity (CV) by the cross-correlation method, and determination of median frequency (fm) and root mean square (rms) amplitude. Perceived exertion was rated for both muscles, and heart rate and blood pressure were measured. The EMG of ten brief 15% MVC contractions distributed over a 30-min recovery period was also recorded. Eleven males in their twenties volunteered for the investigation. The average endurance time was 906 (SD 419) s. Mean CV for the unfatigued muscles was 4.2 (SD 0.41) m·s–1 (BR), and 4.3 (SD 0.29) m·s–1 (BB). The contraction caused a significant decrease in CV of BR (12%,P<0.001) whereas CV variation of BB remained insignificant. Concurrently the meanf m of both muscles dropped to approximately 66% of their initial values and their average rms amplitudes grew by approximately 380% (BR and BB:P<0.001, both parameters). The 1st min of recovery lowered the rms amplitudes by approximately 60% (BR and BB:P<0.01), while thef m increased to approximately 88% of the initial recording (BR,P<0.01; BB,P<0.05). The accompanying small increases in CV were beyond the level of significance. Over the next 29 min a significant parallel restitution inf m and CV took place; changes inf m evidenced a simple one to one reflection of relative CV variation. A similar uncomplicated linear causality between relative changes in CV andf m was hypothesized for the endurance contraction. Consequently, the 12% CV decrease of the BR accounted for only one-third of the fatigue inducedf m reduction of 33%, while two-thirds were assumed to be attributable to centrally mediated regulatory interventions in motor unit (MU) performance. Independent of contributions from the virtually unchanged CV, thef m of the BB muscle decreased by 35%; from one subject exhibiting a remarkably manifest burst-type pattern of MU activity it is argued that synchronization/grouping of MU firing predominantly determined the power redistribution in the BB spectrum.  相似文献   

5.
Amplitude and frequency content of the surface electromyographic (EMG) signal reflect central and peripheral modifications of the neuromuscular system. Classic surface EMG spectral variables applied to assess muscle functions are the centroid and median power spectral frequencies. More recently, nonlinear tools have been introduced to analyze the surface EMG; among them, the recurrence quantification analysis (RQA) was shown to be particularly promising for the detection of muscle status changes. The purpose of this work was to analyze the effect of motor unit short-term synchronization and conduction velocity (CV) on EMG spectral variables and two variables extracted by RQA, the percentage of recurrence (%Rec) and determinism (%Det). The study was performed on the basis of a simulation model, which allowed changing the degree of synchronization and mean CV of a number of motor units, and of an experimental investigation of the surface EMG signal properties detected during high-force-level isometric fatiguing contractions of the biceps brachii muscle. Simulations and experimental results were largely in agreement and show that 1) spectral variables, %Rec, and %Det are influenced by CV and degree of synchronization; 2) spectral variables are highly correlated with %Det (R = -0.95 in the simulations and -0.78 and -0.75 for the initial values and normalized slopes, respectively, in the experimental signals), and thus the information they provide on muscle properties is basically the same; and 3) variations of %Det and %Rec in response to changes in muscle properties are significantly larger than the variations of spectral variables. This study validates RQA as a means for fatigue assessment with potential advantages (such as the higher sensitivity to changes of muscle status) with respect to the classic spectral analysis.  相似文献   

6.
Frequency analysis of myoelectric (ME) signals, using the mean power spectral frequency (MNF), has been widely used to characterize peripheral muscle fatigue during isometric contractions assuming constant force. However, during repetitive isokinetic contractions performed with maximum effort, output (force or torque) will decrease markedly during the initial 40-60 contractions, followed by a phase with little or no change. MNF shows a similar pattern. In situations where there exist a significant relationship between MNF and output, part of the decrease in MNF may per se be related to the decrease in force during dynamic contractions. This study estimated force effects on the MNF shifts during repetitive dynamic knee extensions. Twenty healthy volunteers participated in the study and both surface ME signals (from the right vastus lateralis, vastus medialis, and rectus femoris muscles) and the biomechanical signals (force, position, and velocity) of an isokinetic dynamometer were measured. Two tests were performed: (i) 100 repetitive maximum isokinetic contractions of the right knee extensors, and (ii) five gradually increasing static knee extensions before and after (i). The corresponding ME signal time-frequency representations were calculated using the continuous wavelet transform. Compensation of the MNF variables of the repetitive contractions was performed with respect to the individual MNF-force relation based on an average of five gradually increasing contractions. Whether or not compensation was necessary was based on the shape of the MNF-force relationship. A significant compensation of the MNF was found for the repetitive isokinetic contractions. In conclusion, when investigating maximum dynamic contractions, decreases in MNF can be due to mechanisms similar to those found during sustained static contractions (force-independent component of fatigue) and in some subjects due to a direct effect of the change in force (force-dependent component of fatigue). In order to compare MNF shifts during sustained static and repetitive dynamic contractions it is necessary to estimate the force-dependent component of fatigue of dynamic contractions. Our results are preliminary and have to be confirmed in larger experiments using single dynamic contractions when determining the MNF-force relationship of the unfatigued situation.  相似文献   

7.
We constructed cross-correlograms (CCGs) of action potentials of pairs of motor units (MUs) of human soleus, triceps brachii, and the first and second dorsal interosseous muscles. During voluntary muscle contraction, a pronounced peak in the zero bin was found in 21 out of 126 pairs investigated with the aid of the CCG; this indicates that the number of coincidental firings exceeded chance. The width of the peak did not exceed 5 msec (synchronization for a brief interval, i.e., short-term synchronization). When motoneurons of the soleus muscle were activated by vibration, correlations were found in 12 out 89 pairs of MUs investigated. On the CCGs of action potentials of MU pairs in two muscles (the first and second dorsal interosseous muscles), such correlations were found in four out of 10 pairs investigated. In all of these cases, the ratio of above-change coincidences relative to the total number of MU discharges was small, from 3.0 to 6.1%. Synchronization within a brief time interval can be considered a result of simultaneous creation of EPSPs in motoneourons reached by endings of a single pre-motor nerve fiber. In some pairs of MUs, long term synchronization (clustering) occurred, ie., synchronization lasting several tens of milliseconds. The long-term synchronization can be considered a manifestation of fatigue accompanying tremor.Institute for Problems of Information Transmission, Russian Academy of Sciences, Moscow. Translated from Neirofiziologiya, Vol. 23, No. 6, pp. 691–698, November–December, 1991.  相似文献   

8.
The synchronized firings of active motor units (MUs) increase the oscillations of muscle force, observed as physiological tremor. This study aimed to investigate the effects of synchronizing the firings within three types of MUs (slow—S, fast resistant to fatigue–FR, and fast fatigable–FF) on the muscle force production using a mathematical model of the rat medial gastrocnemius muscle. The model was designed based on the actual proportion and physiological properties of MUs and motoneurons innervating the muscle. The isometric muscle and MU forces were simulated by a model predicting non-synchronized firing of a pool of 57 MUs (including 8 S, 23 FR, and 26 FF) to ascertain a maximum excitatory signal when all MUs were recruited into the contraction. The mean firing frequency of each MU depended upon the twitch contraction time, whereas the recruitment order was determined according to increasing forces (the size principle). The synchronization of firings of individual MUs was simulated using four different modes and inducing the synchronization of firings within three time windows (± 2, ± 4, and ± 6 ms) for four different combinations of MUs. The synchronization was estimated using two parameters, the correlation coefficient and the cross-interval synchronization index. The four scenarios of synchronization increased the values of the root-mean-square, range, and maximum force in correlation with the increase of the time window. Greater synchronization index values resulted in higher root-mean-square, range, and maximum of force outcomes for all MU types as well as for the whole muscle output; however, the mean spectral frequency of the forces decreased, whereas the mean force remained nearly unchanged. The range of variability and the root-mean-square of forces were higher for fast MUs than for slow MUs; meanwhile, the relative values of these parameters were highest for slow MUs, indicating their important contribution to muscle tremor, especially during weak contractions.  相似文献   

9.
Motor unit (MU) synchronization is the simultaneous or near-simultaneous firing of two MUs which occurs more often than would be expected by chance. The present study sought to investigate the effects of exercise training, muscle group, and force level, by comparing the magnitude of synchronization in the biceps brachii (BB) and first dorsal interosseous (FDI) muscles of untrained and strength-trained college-aged males at two force levels, 30% of maximal voluntary contraction (MVC) and 80% MVC. MU action potentials were recorded directly via an intramuscular needle electrode. The magnitude of synchronization was assessed using previously-reported synchronization indices: k′, E, and CIS. Synchronization was significantly higher in the FDI than in the BB. Greater synchronization was observed in the strength-trained group with CIS, but not with E or k′. Also, synchronization was significantly greater at 80% MVC than at 30% MVC with E, but only moderately greater with CIS and there was no force difference with k′. Synchronization prevalence was found to be greater in the BB (80.1%) than in the FDI (71.5%). Thus, although the evidence is a bit equivocal, it appears that MU synchronization is greater at higher forces, and greater in strength-trained individuals than in untrained subjects.  相似文献   

10.
11.
The central- and peripheral mechanisms by which heat strain limits physical performance are not fully elucidated. Nevertheless, pre-cooling is often used in an attempt to improve subsequent performance. This study compared the effects of pre-cooling vs. a pre-thermoneutral application on central- and peripheral fatigue during 60% of isometric maximum voluntary contraction (MVC) of the right quadriceps femoris muscle. Furthermore, the effects between a pre-cooling and a pre-thermoneutral application on isometric MVC of the right quadriceps femoris muscle and subjective ratings of perceived exertion (RPE) were investigated. In this randomized controlled trial, 18 healthy adults voluntarily participated. The participants received either a cold (experimental) application (+8 °C) or a thermoneutral (control) application (+32 °C) for 20 min on their right thigh (one cuff). After the application, central (fractal dimension – FD) and peripheral (muscle fiber conduction velocity – CV) fatigue was estimated using sEMG parameters during 60% of isometric MVC. Surface EMG signals were detected from the vastus medialis and lateralis using bidimensional arrays. Immediately after the submaximal contraction, isometric MVC and RPE were assessed. Participants receiving the cold application were able to maintain a 60% isometric MVC significantly longer when compared to the thermoneutral group (mean time: 78 vs. 46 s; p=0.04). The thermoneutral application had no significant impact on central fatigue (p>0.05) compared to the cold application (p=0.03). However, signs of peripheral fatigue were significantly higher in the cold group compared to the thermoneutral group (p=0.008). Pre-cooling had no effect on isometric MVC of the right quadriceps muscle and ratings of perceived exertion. Pre-cooling attenuated central fatigue and led to significantly longer submaximal contraction times compared to the pre-thermoneutral application. These findings support the use of pre-cooling procedures prior to submaximal exercises of the quadriceps muscle compared to pre-thermoneutral applications.  相似文献   

12.
This study investigated whether pain-induced changes in cervical muscle activation affect myoelectric manifestations of cervical muscle fatigue. Surface EMG signals were detected from the sternocleidomastoid and splenius capitis muscles bilaterally from 14 healthy subjects during 20-s cervical flexion contractions at 25% of the maximal force. Measurements were performed before and after the injection of 0.5 ml of hypertonic (painful) or isotonic (control) saline into either the sternocleidomastoid or splenius capitis in two experimental sessions. EMG average rectified value and mean power spectral frequency were estimated throughout the sustained contraction. Sternocleidomastoid or splenius capitis muscle pain resulted in lower sternocleidomastoid EMG average rectified value on the side of pain (P < 0.01). However, changes over time of sternocleidomastoid EMG average rectified value and mean frequency (myoelectric manifestations of fatigue) during sustained flexion were not changed during muscle pain. These results demonstrate that pain-induced modifications of cervical muscle activity do not change myoelectric manifestations of fatigue. This finding has implications for interpreting the mechanisms underlying greater cervical muscle fatigue in people with neck pain disorders.  相似文献   

13.

Objective

To investigate whether fatigue induced by an intermittent motor task in patients with cancer-related fatigue (CRF) is more central or peripheral.

Methods

Ten patients with CRF who were off chemo and radiation therapies and 14 age-matched healthy controls were enrolled. Participants completed a Brief Fatigue Inventory (BFI) and performed a fatigue task consisting of intermittent elbow-flexion contractions at submaximal (40% maximal voluntary contraction) intensity till self-perceived exhaustion. Twitch force was elicited by an electrical stimulation applied to the biceps brachii muscle. The relative degree of peripheral (muscle) vs. central contribution to fatigue induced by the intermittent motor task (IMT) was assessed using twitch force ratio (TFratio) defined as post IMT twitch force to pre IMT twitch force. The total number of trials (intermittent contractions) and total duration of all trials performed by each subject were also quantified.

Results

BFI scores were higher (p<0.001) in CRF than controls, indicating greater feeling of fatigue in CRF patients than controls. A significantly smaller number of trials and shorter total duration of the trials (p<0.05) were observed in CRF than control participants. The TFratio (0.81±0.05) in CRF was higher (p<0.05) compared with that of controls (0.62±0.05), suggesting CRF patients experienced a significantly lower degree of muscle (peripheral) fatigue at the time of perceived exhaustion.

Conclusion

Consistent with prior findings for fatigue under submaximal sustained contraction, our results indicate that motor fatigue in CRF is more of central than peripheral origin during IMT. Significant central fatigue in CRF patients limits their ability to prolong motor performance.  相似文献   

14.
This study investigated possible motor unit (MU) firing patterns underlying changes in biceps brachii (BB) surface electromyographic (SEMG) activity in 96 participants who performed isometric actions of the elbow flexors at 40%, 60%, 80%, and 100% of maximum voluntary contraction (MVC). We also conducted a modeling investigation to determine the extent to which a model would fit the experimental results. Experimentally, there was a linear increase (277%; p < 0.01) in root-mean-square (RMS) amplitude with increasing force. The mean power frequency (MNF) remained stable from 40% to 80% of MVC, but there was a decrease (8.2%; p < 0.01) between 80% and 100% of MVC. A modeling approach was taken wherein well-known recruitment and rate-coding schemes activated MUs whose basic building block was the muscle fibre action potential. Two conditions were investigated: (1) an increase in firing rate (rate-coding) and (2) synchronization. The levels of rate-coding and synchronization were selected to produce a linear RMS–force relationship as observed in the experimental data. Then, the impact of these two strategies on changes in MNF was assessed. The MNF remained stable from 40% to 80% of maximum excitation for both the rate-coding and synchronization conditions. There was a decrease in MNF between 80% and 100% of maximum excitation for both modeling conditions, similar to that observed for the experimental data. Thus, at these high forces at which experimental data are technically difficult to obtain, the model supports the idea that both rate-coding and synchronization are responsible for the changes observed in surface EMG amplitude and frequency characteristics.  相似文献   

15.

Purpose

To examine quadriceps muscle fatigue and central motor output during fatiguing single joint exercise at 40% and 80% maximal torque output in resistance trained men.

Method

Ten resistance trained men performed fatiguing isometric knee extensor exercise at 40% and 80% of maximal torque output. Maximal torque, rate of torque development, and measures of central motor output and peripheral muscle fatigue were recorded at two matched volumes of exercise, and after a final contraction performed to exhaustion. Central motor output was quantified from changes in voluntary activation, normalized surface electromyograms (EMG), and V-waves. Quadriceps muscle fatigue was assessed from changes in the size and shape of the resting potentiated twitch (Q.pot.tw). Central motor output during the exercise protocols was estimated from EMG and interpolated twitches applied during the task (VAsub).

Results

Greater reductions in maximal torque and rate of torque development were observed during the 40% protocol (p<0.05). Maximal central motor output did not change for either protocol. For the 40% protocol reductions from pre-exercise in rate and amplitude variables calculated from the Q.pot.tw between 66.2 to 70.8% (p<0.001) exceeded those observed during the 80% protocol (p<0.01). V-waves only declined during the 80% protocol between 56.8 ± 35.8% to 53.6 ± 37.4% (p<0.05). At the end of the final 80% contraction VAsub had increased from 91.2 ± 6.2% to 94.9 ± 4.7% (p = 0.005), but a greater increase was observed during the 40% contraction where VAsub had increased from 67.1 ± 6.1% to 88.9 ± 9.6% (p<0.001).

Conclusion

Maximal central motor output in resistance trained men is well preserved despite varying levels of peripheral muscle fatigue. Upregulated central motor output during the 40% contraction protocol appeared to elicit greater peripheral fatigue. V-waves declines during the 80% protocol suggest intensity dependent modulation of the Ia afferent pathway.  相似文献   

16.
The time course of muscle fiber conduction velocity and surface myoelectric signal spectral (mean and median frequency of the power spectrum) and amplitude (average rectified and root-mean-square value) parameters was studied in 20 experiments on the tibialis anterior muscle of 10 healthy human subjects during sustained isometric voluntary or electrically elicited contractions. Voluntary contractions at 20% maximal voluntary contraction (MVC) and at 80% MVC with duration of 20 s were performed at the beginning of each experiment. Tetanic electrical stimulation was then applied to the main muscle motor point for 20 s with surface electrodes at five stimulation frequencies (20, 25, 30, 35, and 40 Hz). All subjects showed myoelectric manifestations of muscle fatigue consisting of negative trends of spectral variables and conduction velocity and positive trends of amplitude variables. The main findings of this work are 1) myoelectric signal variables obtained from electrically elicited contractions show fluctuations smaller than those observed in voluntary contractions, 2) spectral variables are more sensitive to fatigue than conduction velocity and the average rectified value is more sensitive to fatigue than the root-mean-square value, 3) conduction velocity is not the only physiological factor affecting spectral variables, and 4) contractions elicited at supramaximal stimulation and frequencies greater than 30 Hz demonstrate myoelectric manifestations of muscle fatigue greater than those observed at 80% MVC sustained for the same time.  相似文献   

17.
The purpose of this study was to determine whether surface electromyography (EMG) assessment of myoelectric manifestations of muscle fatigue is capable of detecting differences between the vastus lateralis and medialis muscles which are consistent with the results of previous biopsy studies. Surface EMG signals were recorded from the vastus medialis longus (VML), vastus medialis obliquus (VMO) and vastus lateralis (VL) muscles during isometric knee extension contractions at 60% and 80% of the maximum voluntary contraction (MVC) for 10 s and 60 s, respectively. Initial values and rate of change of mean frequency (MNF), average rectified value (ARV) and conduction velocity (CV) of the EMG signal were calculated. Comparisons between the two force levels revealed that the initial values of MNF for the VL muscle were greater at 80% MVC compared to 60% MVC (P < 0.01). Comparisons between the vasti muscles demonstrated lower initial values of CV for VMO compared to VL at 60% MVC (P < 0.01) and lower than VML and VL at 80% MVC (P < 0.01). In addition, initial values of MNF were higher for VL with respect to both VML and VMO at 80% MVC (P < 0.01) and initial estimates of ARV were higher for VMO compared to VML at both force levels (P < 0.01 at 60% MVC and P < 0.05 at 80% MVC). For the sustained contraction at 80% MVC, VL demonstrated a greater decrease in CV over time compared to VMO (P < 0.05).These findings suggest that surface EMG signals and their time course during sustained isometric contractions may be useful to non-invasively describe functional differences between the vasti muscles.  相似文献   

18.
The aim of this study was to interpret changes in experimentally recorded M waves with progressive motor unit (MU) activation based on simulation of the surface electromyogram. Activation order during transcutaneous electrical stimulation was analyzed by investigating M-wave average rectified value, spectral properties, and conduction velocity (CV) during electrically elicited contractions. M-waves were detected from the biceps brachii muscle of 10 healthy male subjects by a linear adhesive array of eight electrodes. Electrical stimulation was delivered to the motor point at either constant current intensity (40, 60, 80, and 100% of the supramaximal stimulation current) or with linearly increasing current. A model of surface electromyogram generation that varied activation order based on MU size and location was used to interpret the experimental results. From the experimental and model analysis, it was found that 1) MUs tended to be activated from low to high CV and from the superficial to the deep muscle layers with increasing transcutaneous electrical stimulation of the biceps brachii muscle, and 2) characteristic spectral frequencies of the M-wave were affected by many factors other than average CV (such as the activation order by MU location or the spread of the MU innervation zones and CVs), thus decreasing with a concomitant increase in CV during progressive MU activation.  相似文献   

19.
The objective of the present study was to investigate whether isometric contraction of the right triceps brachii muscle, of maximal duration and at 25% of the maximal voluntary contraction (MVC), would reduce mean fibre conduction velocity (CV) for the active motor units (MU). In addition to the cross-correlation of surface electromyograms (EMG) for CV determination, median frequency (fm) and root-mean-square amplitude (rms-amplitude) were calculated. The initial 5 min of the recovery of the three parameters was also investigated. The MVC were performed before and after the sustained contraction. Seven males-six in their twenties and one aged 43-participated in the investigation. Mean CV for the unfatigued muscle was 4.5 m.s-1, SD 0.38. On average, CV decreased less than 10% during the sustained contraction (P less than 0.05). The fm decreased almost linearly (46%) during the endurance time, while three quarters of the 250% increase in rms-amplitude took place during the last 50% of the contraction (P less than 0.001, both parameters). The MVC was reduced by 39% immediately after exhaustion (P less than 0.05). During the 1st min of recovery the rms-amplitude decreased by 50%, and the fm increased from 54% to 82% of the initial value (both P less than 0.05). No measurable simultaneous CV restitution occurred. A parallel 15% increase in fm and CV took place during the last 4 min of recovery (both P less than 0.001), while the amplitude remained constant. Since mean CV was essentially unchanged during the last 50% of the endurance time where large changes in fm and rms-amplitude occurred, factors supplementary to CV probably caused the striking changes in fatigue EMG, notably-MU recruitment, synchronization of MU activity, and lowering of MU firing frequencies. Nevertheless, during the last 4 min of recovery the entire increase in fm could be accounted for by the simultaneous increase in CV.  相似文献   

20.
Motor unit recruitment strategies investigated by surface EMG variables.   总被引:9,自引:0,他引:9  
During isometric contractions of increasing strength, motor units (MUs) are recruited by the central nervous system in an orderly manner starting with the smallest, with muscle fibers that usually show the lowest conduction velocity (CV). Theory predicts that the higher the velocity of propagation of the action potential, the higher the power at high frequencies of the detected surface signal. These considerations suggest that the power spectral density of the surface detected electromyogram (EMG) signal may give indications about the MU recruitment process. The purpose of this paper is to investigate the potential and limitations of spectral analysis of the surface EMG signal as a technique for the investigation of muscle force control. The study is based on a simulation approach and on an experimental investigation of the properties of surface EMG signals detected from the biceps brachii during isometric linearly increasing torque contractions. Both simulation and experimental data indicate that volume conductor properties play an important role as confounding factors that may mask any relation between EMG spectral variables and estimated CV as a size principle parameter during ramp contractions. The correlation between spectral variables and CV is thus significantly lower when the MU pool is not stable than during constant-torque isometric contractions. Our results do not support the establishment of a general relationship between spectral EMG variables and torque or recruitment strategy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号