首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Hong JW  Quake SR 《Nature biotechnology》2003,21(10):1179-1183
Microfluidic chip platforms for manipulating liquid volumes in the nanoliter range are slowly inching their way into mainstream genomic and proteomic research. The principal challenge faced by these technologies is the need for high-throughput processing of increasingly smaller volumes, with ever higher degrees of parallelization. Significant advances have been made over the past few years in addressing these needs through electrokinetic manipulation, vesicle encapsulation and mechanical valve approaches. These strategies allow levels of integration density and platform complexity that promise to make them into serious alternatives to current robotic systems.  相似文献   

2.
In traditional screening with 96-well plates, microliters of substrates are consumed for each reaction. Further miniaturization is limited by the special equipment and techniques required to dispense nanoliter volumes of fluid. Plug-based microfluidics confines reagents in nanoliter plugs (droplets surrounded by fluorinated carrier fluid), and uses simple pumps to control the flow of plugs. By using cartridges pre-loaded with nanoliter plugs of reagents, only two pumps and a merging junction are needed to set up a screen. Screening with preloaded cartridges uses only nanoliters of substrate per reaction, and requires no microfabrication. The low cost and simplicity of this method has the potential of replacing 96-well and other multi-well plates, and has been applied to enzymatic assays, protein crystallization and optimization of organic reactions.  相似文献   

3.
Functional metagenomics is an attractive culture-independent approach for functional screening of diverse microbiomes to identify known and novel genes. Since functional screening can involve sifting through tens of thousands of metagenomic library clones, an easy high-throughput screening approach is desirable. Here, we demonstrate a proof-of-concept application of a low-cost, high-throughput droplet based microfluidic assay to the selection of antibiotic resistance genes from a soil metagenomic library. Metagenomic library members encapsulated in nanoliter volume water-in-oil droplets were printed on glass slides robotically, and cell growth in individual drops in the presence of ampicillin was imaged and quantified to identify ampicillin-resistant clones. From the hits, true positives were confirmed by sequencing and functional validation. The ease of liquid handling, ease of set-up, low cost, and robust workflow makes the droplet-based nano-culture platform a promising candidate for screening and selection assays for functional metagenomic libraries.  相似文献   

4.
A high-throughput mass spectrometry assay to measure the catalytic activity of phosphatidylserine decarboxylase (PISD) is described. PISD converts phosphatidylserine to phosphatidylethanolamine during lipid synthesis. Traditional methods of measuring PISD activity are low throughput and unsuitable for the high-throughput screening of large compound libraries. The high-throughput mass spectrometry assay directly measures phosphatidylserine and phosphatidylethanolamine using the RapidFiretrade mark platform at a rate of 1 sample every 7.5 s. The assay is robust, with an average Z' value of 0.79 from a screen of 9920 compounds. Of 60 compounds selected for confirmation, 54 are active in dose-response studies. The application of high-throughput mass spectrometry permitted a high-quality screen to be performed for an otherwise intractable target.  相似文献   

5.
Since only a small fraction of environmental bacteria are amenable to laboratory culture, there is great interest in genomic sequencing directly from single cells. Sufficient DNA for sequencing can be obtained from one cell by the Multiple Displacement Amplification (MDA) method, thereby eliminating the need to develop culture methods. Here we used a microfluidic device to isolate individual Escherichia coli and amplify genomic DNA by MDA in 60-nl reactions. Our results confirm a report that reduced MDA reaction volume lowers nonspecific synthesis that can result from contaminant DNA templates and unfavourable interaction between primers. The quality of the genome amplification was assessed by qPCR and compared favourably to single-cell amplifications performed in standard 50-μl volumes. Amplification bias was greatly reduced in nanoliter volumes, thereby providing a more even representation of all sequences. Single-cell amplicons from both microliter and nanoliter volumes provided high-quality sequence data by high-throughput pyrosequencing, thereby demonstrating a straightforward route to sequencing genomes from single cells.  相似文献   

6.
In this study, the development of an image-based high-content screening (HCS) binding assay for the seven-transmembrane (7TM) receptor Smoothened (Smo) is described. Using BacMam-based gene delivery of Smo, BODIPY-cyclopamine as a fluorescent probe, and a confocal imaging system, a robust 384-well assay that could be used for high-throughput compound profiling activities was developed. The statistically robust HCS binding assay was developed through optimization of multiple parameters, including cell transduction conditions, Smo expression levels, the image analysis algorithm, and staining procedures. Evaluation of structurally diverse compounds, including functional Smo activators, inhibitors, and related analogs, demonstrated good compound potency correlations between high-content imaging binding, membrane fluorescence polarization binding, and gene reporter assays. Statistical analysis of data from a screening test set of compounds at a single 10-μM concentration suggested that the high-content imaging Smo binding assay is amenable for use in hit identification. The 384-well HCS assay was rapidly developed and met statistical assay performance targets, thus demonstrating its utility as a fluorescent whole-cell binding assay suitable for compound screening and profiling.  相似文献   

7.
Wu HC  Shieh J  Wright DJ  Azarani A 《BioTechniques》2003,34(1):204-207
An automated high-throughput method that employs rolling circle amplification (RCA) to generate template for large-scale DNA sequencing has been developed using liquid handling systems equipped with precision glass syringes. A protocol was designed to perform the sequencing analysis from template preparation to thermal cycle sequencing within the same vessel, thus minimizing the amount of liquid handling and transfer. The amplified DNA was directly used for cycle sequencing with no need for any purification procedures. Total RCA reaction volumes as low as 500 nL generated sufficient templates for successful sequencing. Reducing the RCA total reaction volumes by a 40-fold factor, from a total of 20 microL to 500 nL, resulted in a significant reduction in cost, from $1.25/reaction to less than $0.04/reaction. Additionally, the volume of the sequencing reactions was reduced from a total of 20 to 10 microL, thus generating a further cost advantage. This high-throughput DNA sequencing protocol maximizes the speed and precision of processing while significantly reducing the cost of amplification.  相似文献   

8.
A multiple laboratory study was conducted in accordance with the standards established by the Clinical and Laboratory Standards Institute (CLSI), formerly the National Committee for Clinical Laboratory Standards (NCCLS), for the development of quality control (QC) ranges using dilution antimicrobial susceptibility testing methods for bacterial isolates from aquatic animal species. QC ranges were established for Escherichia coli ATCC 25922 and Aeromonas salmonicida subsp. salmonicida ATCC 33658 when testing at 22, 28 and 35 degrees C (E. coli only) for 10 different antimicrobial agents (ampicillin, enrofloxacin, erythromycin, florfenicol, flumequine, gentamicin, ormetoprim/sulfadimethoxine, oxolinic acid, oxytetracycline and trimethoprim/sulfamethoxazole). Minimum inhibitory concentration (MIC) QC ranges were determined using dry- and frozen-form 96-well plates and cation-adjusted Mueller-Hinton broth. These QC ranges were accepted by the CLSI/NCCLS Subcommittee on Veterinary Antimicrobial Susceptibility Testing in January 2004. This broth microdilution testing method represents the first standardized method for determining MICs of bacterial isolates whose preferred growth temperatures are below 35 degrees C. Methods and QC ranges defined in this study will enable aquatic animal disease researchers to reliably compare quantitative susceptibility testing data between laboratories, and will be used to ensure both precision and inter-laboratory harmonization.  相似文献   

9.
Recent studies evaluating bulk soap in public restroom soap dispensers have demonstrated up to 25% of open refillable bulk-soap dispensers were contaminated with ~ 6 log(10)(CFU ml(-1)) heterotrophic bacteria. In this study, plastic counter-mounted, plastic wall-mounted and stainless steel wall-mounted dispensers were analyzed for suspended and biofilm bacteria using total cell and viable plate counts. Independent of dispenser type or construction material, the bulk soap was contaminated with 4-7 log(10)(CFU ml(-1)) bacteria, while 4-6 log(10)(CFU cm(-2)) biofilm bacteria were isolated from the inside surfaces of the dispensers (n = 6). Dispenser remediation studies, including a 10 min soak with 5000 mg l(-1) sodium hypochlorite, were then conducted to determine the efficacy of cleaning and disinfectant procedures against established biofilms. The testing showed that contamination of the bulk soap returned to pre-test levels within 7-14 days. These results demonstrate biofilm is present in contaminated bulk-soap dispensers and remediation studies to clean and sanitize the dispensers are temporary.  相似文献   

10.
11.
High-throughput molecular biology and crystallography advances have placed an increasing demand on crystallization, the one remaining bottleneck in macromolecular crystallography. This paper describes three experimental approaches, an incomplete factorial crystallization screen, a high-throughput nanoliter crystallization system, and the use of a neural net to predict crystallization conditions via a small sample (approximately 0.1%) of screening results. The use of these technologies has the potential to reduce time and sample requirements. Initial experimental results indicate that the incomplete factorial design detects initial crystallization conditions not previously discovered using commercial screens. This may be due to the ability of the incomplete factorial screen to sample a broader portion of "crystallization space," using a multidimensional set of components, concentrations, and physical conditions. The incomplete factorial screen is complemented by a neural network program used to model crystallization. This capability is used to help predict new crystallization conditions. An automated, nanoliter crystallization system, with a throughput of up to 400 conditions/h in 40-nl droplets (total volume), accommodates microbatch or traditional "sitting-drop" vapor diffusion experiments. The goal of this research is to develop a fully-automated high-throughput crystallization system that integrates incomplete factorial screen and neural net capabilities.  相似文献   

12.
Reducing the scale of biochemical reactions is becoming commonplace. Examples include the screening of large libraries of chemical compounds or gene sequences. These applications demand the ability to transfer sub-microliter volumes of fluid. To this end, we have modified a Hamilton MICROLAB 2200 with high-speed solenoids and a liquid pressurization system to modulate volume delivery down to the nanoliter level. Additional modifications include the use of sapphire-tipped dispensing nozzles and a high-resolution substage to assist in the construction of DNA microarrays. Techniques for characterizing the dispensed volume are presented.  相似文献   

13.
Metabolic stability plays an important role in the success of drug candidates. First-pass metabolism is one of the major causes of poor oral bioavailability and short half-life. Traditionally, metabolic stability was evaluated at a later stage of drug discovery and required laborious manual manipulations. With the advance of high-throughput screening, combinatorial chemistry, and early profiling of drug-like properties, automated and rapid stability assays are needed to meet the increasing demand of throughput, speed, and reproducibility at earlier stages of drug discovery. The authors describe optimization of a simple, robust, high-throughput microsomal stability assay developed in a 96-well format. The assay consists of 2 automated components: robotic sample preparation for incubation and cleanup and rapid liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) analysis to determine percent remaining of the parent compound. The reagent solutions and procedural steps were optimized for automation. Variables affecting assay results were investigated. The variability introduced by microsome preparations from different sources (various vendors and batches) was studied and indicates the need for careful control. Quality control and normalization of the stability results are critical when applying the screening data, generated at different times or research sites, to discovery projects.  相似文献   

14.
We consider the application of high-throughput experimentation (HTE), including combinatorial methods, to catalyst discovery and early-phase optimization. While combinatorial- and parallel-testing methods have an already substantial history in catalysis, recent work by several groups promises significant efficiency gains. In molecular catalysis, progress is noted in library design, library synthesis by pooled, parallel, and discrete formats, catalyst testing and reaction optimization; the prime constraint for organometallic catalysts is the limited scope of synthesis procedures for non-peptide-based ligand libraries. Routes described for the synthesis of heterogeneous catalysts include hydrothermal synthesis, arraying of solution precursors, automated impregnation and precipitation, and arraying of solid precursors. The key challenge in applying HTE to heterogeneous catalysis is testing; we distinguish here between Stage 1, or "discovery" testing and Stage 2, optimization testing, and describe techniques with potential in each case. Recent examples from the literature and our own work are used to illustrate these principles and the prospects for HTE applied to catalysis.  相似文献   

15.
The development of purification processes for protein biopharmaceuticals is challenging due to compressed development timelines, long experimental times, and the need to survey a large parameter space. Typical methods for development of a chromatography step evaluate several dozen chromatographic column runs to optimize the conditions. An efficient batch-binding method of screening chromatographic purification conditions in a 96-well format with a robotic liquid-handling system is described and evaluated. The system dispenses slurries of chromatographic resins into filter plates, which are then equilibrated, loaded with protein, washed and eluted. This paper evaluates factors influencing the performance of this high-throughput screening technique, including the reproducibility of the aliquotted resin volume, the contact time of the solution and resin during mixing, and the volume of liquid carried over in the resin bed after centrifugal evacuation. These factors led to the optimization of a batch-binding technique utilizing either 50 or 100 microL of resin in each well, the selection of an industrially relevant incubation time of 20 min, and the quantitation of the hold-up volume, which was as much as one quarter of the total volume added to each well. The results from the batch-binding method compared favorably to chromatographic column separation steps for a cGMP protein purification process utilizing both hydrophobic interaction and anion-exchange steps. These high-throughput screening tools can be combined with additional studies on the kinetics and thermodynamics of protein-resin interactions to provide fundamental information which is useful for defining and optimizing chromatographic separations steps.  相似文献   

16.
Methods for tagging biomolecules with fluorine 18 as immuno-positron emission tomography (immunoPET) tracers require tedious optimization of radiolabeling conditions and can consume large amounts of scarce biomolecules. We describe an improved method using a digital microfluidic droplet generation (DMDG) chip, which provides computer-controlled metering and mixing of 18F tag, biomolecule, and buffer in defined ratios, allowing rapid scouting of reaction conditions in nanoliter volumes. The identified optimized conditions were then translated to bench-scale 18F labeling of a cancer-specific engineered antibody fragments, enabling microPET imaging of tumors in xenografted mice at 0.5 to 4 hours postinjection.  相似文献   

17.
Idiosyncratic adverse drug reactions (ADRs) are one of the most common causes of pharmaceutical withdrawals and labeling changes. Most ADRs are caused by drugs that form reactive species that can bind covalently to macromolecules such as proteins. The current methodology for the measurement of covalent binding relies on the use of radiolabeled material that requires an investment in time and resources not typically expended until later in the discovery process. Efforts are also made to identify reactive intermediates by the use of chemical trapping agents, such as reduced glutathione and cyanide, to form stable adducts that are characterized by liquid chromatography-tandem mass spectrometry and/or nuclear magnetic resonance spectroscopy. Here, we describe a high-throughput assay for the measurement of reactive intermediate formation. The method involves incubation of cold compound with liver microsomes in the presence of [14C]potassium cyanide. Hard electrophilic species would react with the trapping agent, resulting in the formation of a radiolabeled conjugate. Unreacted trapping agent is removed using solid-phase extraction, and the amount of radiolabeled conjugate present is determined by liquid scintillation counting. This newly developed screen has proved to be specific, sensitive, robust, and a powerful tool for assessing bioactivation potential.  相似文献   

18.
This paper describes the microfluidic streak plate (MSP), a facile method for high-throughput microbial cell separation and cultivation in nanoliter sessile droplets. The MSP method builds upon the conventional streak plate technique by using microfluidic devices to generate nanoliter droplets that can be streaked manually or robotically onto petri dishes prefilled with carrier oil for cultivation of single cells. In addition, chemical gradients could be encoded in the droplet array for comprehensive dose-response analysis. The MSP method was validated by using single-cell isolation of Escherichia coli and antimicrobial susceptibility testing of Pseudomonas aeruginosa PAO1. The robustness of the MSP work flow was demonstrated by cultivating a soil community that degrades polycyclic aromatic hydrocarbons. Cultivation in droplets enabled detection of the richest species diversity with better coverage of rare species. Moreover, isolation and cultivation of bacterial strains by MSP led to the discovery of several species with high degradation efficiency, including four Mycobacterium isolates and a previously unknown fluoranthene-degrading Blastococcus species.  相似文献   

19.
The study of plant pathogenesis and the development of effective treatments to protect plants from diseases could be greatly facilitated by a high-throughput pathosystem to evaluate small-molecule libraries for inhibitors of pathogen virulence. The interaction between the Gram-negative bacterium Pseudomonas syringae and Arabidopsis thaliana is a model for plant pathogenesis. However, a robust high-throughput assay to score the outcome of this interaction is currently lacking. We demonstrate that Arabidopsis seedlings incubated with P. syringae in liquid culture display a macroscopically visible 'bleaching' symptom within 5 days of infection. Bleaching is associated with a loss of chlorophyll from cotyledonary tissues, and is correlated with bacterial virulence. Gene-for-gene resistance is absent in the liquid environment, possibly because of the suppression of the hypersensitive response under these conditions. Importantly, bleaching can be prevented by treating seedlings with known inducers of plant defence, such as salicylic acid (SA) or a basal defence-inducing peptide of bacterial flagellin (flg22) prior to inoculation. Based on these observations, we have devised a high-throughput liquid assay using standard 96-well plates to investigate the P. syringae-Arabidopsis interaction. An initial screen of small molecules active on Arabidopsis revealed a family of sulfanilamide compounds that afford protection against the bleaching symptom. The most active compound, sulfamethoxazole, also reduced in planta bacterial growth when applied to mature soil-grown plants. The whole-organism liquid assay provides a novel approach to probe chemical libraries in a high-throughput manner for compounds that reduce bacterial virulence in plants.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号