首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Matsuno H  Furusawa H  Okahata Y 《Biochemistry》2005,44(7):2262-2270
Catalytic DNA cleavage reactions by an ATP-dependent deoxyribonuclease (DNase) from Micrococcus luteus were monitored directly with a DNA-immobilized 27-MHz quartz-crystal microbalance (QCM). The 27-MHz QCM is a very sensitive mass-measuring device in aqueous solution, as the frequency decreases linearly with increasing mass on the electrode at a nanogram level. Three steps in ATP-dependent DNA hydrolysis reactions, including (1) binding of DNase to the end of double-stranded DNA (dsDNA) on the QCM electrode (mass increase), (2) degradation of one strand of dsDNA in the 3' --> 5' direction depending on ATP (mass decrease), and (3) release of the enzyme from the nonhydrolyzed 5'-free-ssDNA (mass decrease), could be monitored stepwise from the time dependencies of QCM frequency changes. Kinetic parameters for each step were obtained as follows. The binding constant (K(a)) of DNase to the dsDNA was determined as (28 +/- 2) x 10(6) M(-)(1) (k(on) = (8.0 +/- 0.3) x 10(3) M (-)(1) s(-)(1) and k(off) = (0.29 +/-0.01) x 10(-)(3) s(-)(1)), and it decreased to (0.79 +/- 0.16) x 10(6) M(-)(1) (k'(on) = (2.3 +/- 0.2) x 10(3) M (-)(1) s(-)(1) and k'(off) = (2.9 +/- 0.1) x 10(-)(3) s(-)(1)) for the completely nonhydrolyzed 5'-free ssDNA. This is the reason the DNase bound to the dsDNA substrate can easily release from the nonhydrolyzed 5'-free-ssDNA after the complete hydrolysis of the 3' --> 5' direction of the complementary ssDNA. K(a) values depended on the DNA structures on the QCM, and the order of these values was as follows: the dsDNA having a 4-base-mismatched base-pair end (3) > the dsDNA having a 5' 15-base overhanging end (2) > the dsDNA having a blunt end (1) > the ssDNA having a 3'-free end (4) > the ssDNA having a 5'-free end (5). Thus, DNase hardly recognized the free 5' end of ssDNA. Michaelis-Menten parameters (K(m) for ATP and k(cat)) of the hydrolysis process also could be obtained, and the order of k(cat)/K(m) was as follows: the dsDNA having a blunt end (1) approximately the dsDNA having a 4-base-mismatched base-pair end (3) > the ssDNA having a free 3' end (4) > the ssDNA having a free 5' end (5). Thus, DNase could not recognize and not hydrolyze the free 5' end of ssDNA. The DNA hydrolysis reaction could be driven by dATP and GTP (purine base) as well as ATP, whereas the cleavage efficiency was very low driven with UTP, CTP (pyrimidine base), ADP, and AMP.  相似文献   

2.
We investigate the feasibility of coupling the quartz crystal microbalance (QCM) with magnetic separation for on-line analysis. A flow cell was integrated with QCM and magnetic force for the analysis of magnetic and nonmagnetic samples. The resonant frequency change (Deltaf) of QCM was related to the amount of deposited magnetic nanoparticles. This experiment demonstrates that QCM can be used as an on-line detector for magnetic separation. The QCM also gives a characteristic response of the binding between the streptavidin and biotin labeled on the magnetic nanoparticles. Biotin-labeled magnetic nanoparticles were flowed through a gold electrode of QCM to deposit as a matrix for selective capturing streptavidin. The resonant frequency change of QCM was proportional to the amounts of streptavidin captured by biotin. This technique can provide a simple, economic, and automatic method for on-line detection of biomarkers.  相似文献   

3.
Quartz crystal microbalance immunosensors for environmental monitoring   总被引:1,自引:0,他引:1  
This paper presents discussion of quartz crystal microbalance (QCM) immunosensors for environmental monitoring. Factors limiting the practical application of antibodies to analytical problems are also presented. Among several candidates for the QCM immunosensor device, selected QCM devices and oscillating circuits were tested thoroughly and developed to obtain highly stable and sensitive frequency signals. The biointerface of QCM immunosensor was designed and controlled to immobilize antibody on the QCM surface, to reduce non-specific binding and to suppress denaturation of immobilizing antibody by self-assembled monolayer technique and artificial phospholipid (2-methacryloyloxyethyl phosphorylcholine (MPC)) polymer. MPC polymer as a antibody-stabilizing reagent was added to reduce non-specific binding of the antigen solution and stabilize the immunologic activity of the antibody-immobilized QCM. In addition, it provides examples for detection and quantitation of environmental samples using QCM immunosensors. The analytical results for fly ash extracted samples of dioxins using the QCM immunosensor indicated a good relationship with GC/MS methods. The integrating protocols of the competitive immunoassay and signal-enhancing step are for detecting low molecular analytes with extremely low detection limits using an QCM immunosensor. Furthermore, its detect limitation was extended from 0.1 to 0.01 ng/ml by the signal-enhancing step when the anti-bisphenol-A antibody conjugated MPC polymeric nanoparticles was used. The QCM immunosensor method has demonstrated its effectiveness as an alternative screening method for environmental monitoring because these results were compared with results obtained through environmental monitoring methods such as ELISA and GC/MS.  相似文献   

4.
We demonstrate a label-free peptide-coated carbon nanotube-based immunosensor for the direct assay of human serum. A rheumatoid arthritis (RA)-specific (cyclic citrulline-containing) peptide, was immobilized to functionalized single-walled carbon nanotubes deposited on a quartz crystal microbalance (QCM) sensing crystal. Serum from RA patients was used to probe these nanotube-based sensors, and antibody binding was detected by QCM sensing. Specific antibody binding was also determined by comparing the assay of two serum control groups (normal and diseased sera), and the native unmodified peptide. The sensitivity of the nanotube-based sensor (detection in the femtomol range) was higher than that of the established ELISA and recently described microarray assay systems, detecting 34.4 and 37.5% more RA patients with anti-citrullinated peptide antibodies than those found by ELISA and microarray, respectively. There was also an 18.4 and 19.6% greater chance of a negative test being a true indicator of a person not having RA than by either ELISA or microarray, respectively. The performance of our label-free biosensor enables its application in the direct assay of sera in research and diagnostics.  相似文献   

5.
A bilirubin imprinted polymer (BIP) was coated on a thiol pretreated Au electrode on a quartz crystal microbalance (QCM) chip. The BIP thin film was synthesized using 4-vinylpyridine (4-Vpy) as the monomer, divinylbenzene (DVB) as the cross-linker, and benzophenone as the initiator. By using a photo-graft surface polymerization technique with irradiation by ultra-violet (UV) light, a thin BIP film was prepared, from which a biomimetic sensor for the detection of bilirubin was developed. The sensor was able to discriminate bilirubin in solution owing to the specific binding of the imprinted sites. The BIP/QCM chip has been repeatedly used for more than 7 months in many continuous experiments. The detection signal of bilirubin from the BIP thin film/QCM was compared with the non-BIP thin film/QCM. Biliverdin, an analogue of bilirubin, was used for comparison. The analogue comparison confirmed the binding specificity of the BIP film toward bilirubin. The selectivity can be as high as 31.2. The effect of pH on the detection of bilirubin is also discussed. With proper solvent for elution and recovery, flow injection analysis (FIA) could be applied to the system. The performance of the BIP/QCM chip was evaluated. A linear calibration of the bilirubin concentration with respect to the frequency shift was successfully obtained. The reproducibility of measurements from the same BIP/QCM chip was confirmed. In addition, repeatability of detection was also confirmed from different BIP/QCM chips. In conclusion, a combined BIP thin film/QCM/FIA method was successfully established for the detection of bilirubin concentration using a molecularly imprinted film.  相似文献   

6.
The quartz crystal microbalance (QCM) was first introduced as a mass sensor in gas phase and in vacuum. Since oscillator circuits capable of exciting shear vibrations of quartz resonators under liquid loading have been developed, the QCM became accepted as a new, powerful technique to follow adsorption processes at solid-liquid interfaces in chemical and biological research. Lately, the QCM technique has attracted considerable interest as a novel means to monitor cell-substrate interactions of mammalian cells in vitro. Because the establishment and modulation of cell-substrate contacts is important for many physiological processes, and potent techniques to measure these interactions noninvasively are rare, the present review highlights applications of the QCM technique in this field. The suitability of the QCM device to monitor attachment and spreading of mammalian cells in real time has been well established. The QCM response is dependent on the individual cell type that is examined. In order to identify the sources for these cell-type-specific results of QCM readings, and to understand the information content of the signal, attempts have been made to decompose the overall QCM response into subcellular contributions. The aforementioned subjects, together with a condensed introduction into the QCM technology, are included in this article.  相似文献   

7.
We developed a conventional immunosensor for fibrinogen and fibrin degradation products (FDP) to combine a quartz crystal microbalance (QCM) with the agglutination reaction of immunized latex beads. FDP induced an immunoreaction due to anti-FDP antibody immobilized latex particles. We successfully measured FDP concentration of in human serum within 10 min by QCM method. The detection range of QCM immunosensor is covered with screening concentration of FDP in serum (<10 microg/ml of FDP). The time course of latex agglutination obtained from QCM immunosensor is synchronized to that of latex photometric immunoassay. SEM was used to observe the surface of QCM that applied FDP serum. The size of latex particles agglutinated on the QCM electrode increased concomitant with FDP concentration. Frequency shift on immunoreaction explains the increased adsorption amount of agglutinated latex on QCM.  相似文献   

8.
Quartz crystal microbalance (QCM) sensors are widely used for determining liquid properties or probing interfacial processes. For some applications the sensitivity of the QCM sensors typically used (5–20 MHz) is limited compared with other biosensor methods. In this study ultrasensitive QCM sensors with resonant frequencies from 39 to 110 MHz for measurements in the liquid phase are presented. The fundamental sensor effect of a QCM is the decrease of the resonant frequency of an oscillating quartz crystal due to the binding of mass on a coated surface during the measurement. The sensitivity of QCM sensors increases strongly with an increasing resonant frequency and, therefore, with a decreasing thickness of the sensitive area. The new kind of ultrasensitive QCM sensors used in this study is based on chemically milled shear mode quartz crystals which are etched only in the center of the blank, forming a thin quartz membrane with a thick, mechanically stable outer ring. An immunoassay using a virus specific monoclonal antibody and a M13-Phage showed an increase in the signal to noise ratio by a factor of more than 6 for 56 MHz quartz crystals compared with standard 19 MHz quartz crystals, the detection limit was improved by a factor of 200. Probing of acoustic properties of glycerol/water mixtures resulted in an increase in sensitivity, which is in very good agreement with theory. Chemically milled QCM sensors strongly improve the sensitivity in biosensing and probing of acoustic properties and, therefore, offer interesting new application fields for QCM sensors.  相似文献   

9.
The quartz crystal microbalance (QCM) was used to create piezoelectric whole-cell biosensors utilizing either living endothelial cells (ECs) or the metastatic human mammary cancer cell line MDA-MB-231 adhering to the gold QCM surface under in vitro growth conditions. We utilized the whole-cell QCM biosensors for the detection of the effects of varying concentrations of the microtubule binding drugs taxol and nocodazole by measuring changes in the QCM steady state frequency (Deltaf) and motional resistance (DeltaR), shift values. Using 0.11-50 microM nocodazole, we observed the Deltaf shift values of the biosensors, consisting of 20,000 ECs, to decrease significantly in magnitude (nearly 100%) to a limiting value, in a dose-dependent fashion, over a 5- to 6-h incubation period following drug addition. This effect is consistent with nocodazole's known disruption of intracellular microtubules. On the other hand, 10 microM taxol caused little alteration in Deltaf over the same time period, consistent with its microtubule hyperstabilization effect. When the EC QCM biosensor Deltaf shift values were normalized by the number of ECs found firmly attached to the QCM surface via trypsin removal and electronic counting, the dose curve was shifted to lower nocodazole concentrations, resulting in a more sensitive drug biosensor. The kinetics of the Deltaf decrease with increasing nocodazole concentrations measured by the EC QCM biosensor was found to be similar at all drug concentrations and was well fit by a single first-order exponential decay equation. For all nocodazole doses, t(0.5) was invariant, averaging t(0.5)=0.83+/-0.14 h. These data demonstrate that a single dynamic sensing system within the cell, the microtubules, is disrupted by the addition of nocodazole and this process is sensed by the cell QCM biosensor. This interpretation of the data was confirmed by a fluorescence light microscopy investigation of ECs undergoing treatment with increasing nocodazole doses using a fluorescent antibody to alpha-tubulin. These studies revealed a corresponding loss of the spread morphology of the cells, concomitant with a rearrangement of the extended native microtubules into increasingly large aggregates with the cells eventually lifting from the surface in significant numbers at 50 microM. At 6 microM nocodazole, partial reversibility of the EC QCM biosensor was demonstrated. These results indicate that the EC QCM biosensor can be used to detect and study EC cytoskeleton alterations and dynamics. We suggest the potential of this cellular biosensor for the real-time identification or screening of all classes of biologically active drugs or biological macromolecules that affect cellular attachment and cellular spreading, regardless of their molecular mechanism of action.  相似文献   

10.
This study aimed to prepare a novel quartz crystal microbalance (QCM) sensor for the detection of pirimicarb. Pirimicarb‐imprinted poly (ethylene glycol dimethacrylate‐N‐metacryloyl‐(l )‐tryptophan methyl ester) [p (EGDMA‐MATrp)] nanofilm (MIP) on the gold surface of a QCM chip was synthesized using the molecular imprinting technique. A nonimprinted p (EGDMA‐MATrp) nanofilm (NIP) was also synthesized using the same experimental technique. The MIP and NIP nanofilms were characterized via Fourier transform infrared spectroscopy attenuated total reflectance spectroscopy, contact angle, atomic force microscopy, and an ellipsometer. A competitive adsorption experiment on the sensor was performed to display the selectivity of the nanofilm. An analysis of the QCM sensor showed that the MIP nanofilm exhibited high sensitivity and selectivity for pirimicarb determination. A liquid chromatography‐tandem mass spectrometry method was prepared and validated to determine the accuracy and precision of the QCM sensor. The accuracy and precision of both methods were determined by a comparison of six replicates at three different concentrations to tomato samples extracted by using a Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method. The limit of detection of the QCM sensor was found to be 0.028 nM. In conclusion, the QCM sensor showed good accuracy, with recovery percentages between 91 and 94%. Also, the pirimicarb‐imprinted QCM sensor exhibited a fast response time, reusability, high selectivity and sensitivity, and a low limit of detection. Therefore, it offers a serious alternative to the traditional analytical methods for pesticide detection in both natural sources and aqueous solutions.  相似文献   

11.
An immunosensing system based on a quartz crystal microbalance (QCM) is presented for the selection of both antigen specific recombinant antibodies and antigen specific human pancreatic secretory trypsin inhibitor (hPSTI) mutants isolated from large phage libraries. The QCM was integrated into a flow injection analysis system for the straightforward analysis of large sample numbers. Measurements were performed using a biotinylated antigen immobilized by streptavidin onto the gold surface of the quartz crystal and phages displaying recombinant antibodies or hPSTI mutants. The results obtained by the QCM were in accordance to those of a well established enzyme linked immunosorbent assay (ELISA). Therefore, the QCM is well suited for the detection of single high affinity clones isolated from large phage display libraries.  相似文献   

12.
This study evaluated construction of a highly affinitive quartz crystal microbalance (QCM) immunosensor using anti-C-reactive protein (CRP) antibody and its fragments for CRP detection. Three types of antibody were immobilized on the surface of a QCM via covalent-bounding. Then affinity was evaluated through antigen-antibody binding between CRP and its antibody. Affinity between antigen-antibody was shown to be highest when anti-CRP F(ab')2-IgG antibody (70 microg/mL) was immobilized on the QCM. In case of anti-CRP F(ab')2-IgG antibody, affinity which was attributable to antigen-antibody binding was almost twice that of anti-CRP IgG antibody, which is used conventionally for QCM immunosensors. In addition, when it was treated with 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate, so-called MPC polymer, highly affinitive and selective immunosensing for CRP was achieved without non-specific binding from plasma proteins in human serum. When anti-CRP F(ab')2-IgG antibody was immobilized on the QCM, the detection limit and the linearity of CRP calibration curve were achieved at concentrations from 0.001 to 100 microg/dL even during investigation in serum samples. Experimental results verified the successful construction of a highly affinitive and selective QCM-immunosensor which was modified with anti-CRP F(ab')2-IgG antibody and MPC polymer.  相似文献   

13.
The quartz crystal microbalance (QCM) was used to monitor endothelial cell (EC) adhesion on the gold surface of an oscillating quartz crystal contained in a QCM device. A number of parameters were investigated. First, we observed differential QCM O-ring toxicities for ECs. Second, appropriate conditions for cell culture and QCM cell environment were identified that can eliminate large-scale frequency oscillations in the measurements. These artifacts are not due to added cells but originate in the time-dependent evaporation of water. Having eliminated these artifacts, we then demonstrated that the measured steady-state crystal frequency shift, Delta f, and motional resistance shift, DeltaR, were determined by the number of firmly attached ECs requiring trypsinization from the crystal surface. Last, following steady-state attachment of ECs, the EC growth stimulation by fibroblast growth factor was monitored in a continuous fashion by measuring f and R values over a 72 h. period. We observed the Delta f values to increase in a way that reflected the increase in EC number bound to the QCM surface. Following addition of ECs to the QCM, the time-dependent increase in DeltaR can be interpreted in terms of increase by the ECs of the energy dissipation properties of the solution at the solution-gold surface interface. This effect is due to their rapid surface attachment and the elaboration of their cytoskeletal properties. These results indicate that the QCM technique can be used for the study of EC attachment and growth and suggest its potential for the real time study of per unit surface area cell mass distribution dynamics and viscoelastic properties and the cells' responses to stresses or perturbations brought about using biologically active molecules.  相似文献   

14.
This study proved a possibility of a peptide probe for evaluating affinity properties of proteins. We have designed and synthesized three different peptide probes, H-Ala3-(Gly-Pro5)3-Gly-OH (peptide A), H-Ala3-(Gly-Pro5)-Gly-OH (peptide B) and H-Ala3-Gly-OH (peptide C) for testing their affinities to profilin. Each peptide probe was immobilized on a quartz crystal microbalance (QCM) sensor. The QCM sensor with the peptide A showed a 93 Hz decrease of resonant frequency which indicated profilin bound to the QCM sensor in a single layer. In a successive reaction with actin, the QCM analysis resulted in a 123 Hz decrease of resonant frequency which showed actin bound to the QCM sensor. A fluorescence microscope image of the sensor surface exhibited clear fluorescence after binding a rhodamine labeled actin on the sensor surface. These results supported stepwise reactions of profilin binding to the peptide A and actin binding to profilin. In the three peptide probes, the peptide A showed the highest affinity to profilin, i.e., sequence dependent affinity was confirmed.  相似文献   

15.
In this study we evaluate the strengths and weaknesses of surface plasmon resonance (SPR) spectroscopy and quartz crystal microbalance (QCM) technique for studying DNA assembly and hybridization reactions. Specifically, we apply in parallel an SPR instrument and a 5 MHz QCM device with dissipation monitoring (QCM-D) to monitor the assembly of biotinylated DNA (biotin-DNA) on a streptavidin-modified surface and the subsequent target DNA hybridization. Through the parallel measurements, we demonstrate that SPR is more suitable for quantitative analysis of DNA binding amount, which is essential for interfacial DNA probe density control and for the analysis of its effect on hybridization efficiency and kinetics. Although the QCM is not quantitative to the same extent as SPR (QCM measures the total mass of the bound DNA molecules together with the associated water), the dissipation factor of the QCM provides a qualitative measure of the viscoelastic properties of DNA films and the conformation of the bound DNA molecules. The complexity in mass measurement does not impair QCM's potential for a kinetic evaluation of the hybridization processes. For quantification of target DNA, the biotin-DNA modified SPR and QCM sensors are exposed to target DNA with increasing concentration. The plots of SPR/QCM signals versus target DNA concentration show that water entrapment between DNA strands make the QCM sensitivity for the hybridization assay well comparable with that of the SPR, although the intrinsic mass sensitivity of the 5 MHz QCM is approximately 20 times lower.  相似文献   

16.
Missing mass effect in biosensor's QCM applications   总被引:1,自引:0,他引:1  
Nowadays, liquid applications of quartz crystal microbalance (QCM) opened a way for in situ studies of proteins, vesicles and cells adsorbed from the solution onto the QCM surface. The sensitivity of QCM to the viscoelasticity of the adsorbed biomaterial can be a reason of the experimentally observed deviation from a linear dependence of QCM resonant frequency on mass deposition (the so-called Sauerbrey relation) and can limit its application for biosensoring. Presented here rigorous theoretical analysis explains the deviation from ideal mass response of soft overlayers in the contact with liquid. The fundamental result of the theory is the analog of Sauerbrey relation for layered viscous/viscoelastic medium which can be exploited for the correct physical interpretation of QCM experimental data in biofluids, in particular for measurements of the 'true' surface mass of adsorbed biomolecular films. We predict a new physical effect 'missing mass' of the sample in liquid phase measurements and compare the results given by our theory with QCM measurements on supported membranes.  相似文献   

17.
Study on colloidal Au-enhanced DNA sensing by quartz crystal microbalance   总被引:5,自引:0,他引:5  
Colloidal Au is reported for enhancement the immobilization capacity and ultimately detection limit of DNA using quartz crystal microbalance (QCM). Immobilization of approximately 12 nm-diameter colloidal Au on to an Au-coated QCM resulted in an easier attachment of oligonucleotide, with a mercaptohexyl group at the 5'-phosphate end and an increased capacity for nucleic acid detection. DNA immobilization and hybridization was monitored from QCM frequency changes. Hybridization was induced by exposure of the DNA-containing films to complementary DNA in solution. A much higher sensitivity was obtained for the analyte. The Au nanoparticle films on the Au plate provide a novel means for the fabrication of DNA sensor.  相似文献   

18.
Hybridization rates of sheared, genomic E. coli DNA in 0.14 M, pH 6.7 phosphate buffer at 65 degrees C were determined by: (1) observing the rate of absorbance decrease at 260 nm due to self-hybridization in solution; and (2) measurement of the rate of mass increase caused by hybridization between DNA in solution and DNA photografted to polystyrene. The latter measurement was done using a quartz crystal microbalance (QCM). In both the spectrophotometric and QCM experiments the probe was identical to the target, as both were taken from the same sample of sheared E. coli DNA. In the QCM measurements, viscoelastic effects were made negligible by drying the biopolymer layer on the QCM's surface before taking the frequency readings. Our purpose was to explore the effect of immobilizing DNA on its hybridization rate constant. A second-order constant of 2.32 +/- 0.09 x 10(-6) ml microg(-1) s(-1), n = 14, for hybridization in solution was obtained spectrophotometrically, while the QCM experiment gave a constant of 2.2 +/- 0.3 x 10(-6) ml microg(-1) s(-1), n = 6. These values are not statistically different. The reaction half-lives for the spectrophotometric and QCM experiments were 6.5 h and 13 min, respectively. The shorter half-life on the QCM can be explained solely by the much greater reactant concentration in the QCM experiment. About 25% of the DNA was inactivated by the attachment reaction. After correcting for this, the surface-attached DNA hybridized with the same rate constant as DNA free in solution. Therefore, it is concluded that, in these specific experiments with genomic DNA, the immobilized regions must have been short compared to the length of the molecules. The data demonstrate the high hybridization rate obtainable when nucleic acids are hybridized in a thin-film, micro-volume reaction on a non-porous surface.  相似文献   

19.
For investigating effects of chemical stressors to cultured cells, we have developed a quartz crystal microbalance (QCM) system with a micro CCD camera that enables microscopic observations simultaneously with the QCM measurements. Human hepatoma cell line (HepG2) cells were cultured on the collagen coated quartz crystal which has indium tin oxide (ITO) electrodes that enable transmission imaging of the cultured cells by the micro CCD camera during the QCM measurements. Glutaraldehyde (GA) and t-butylhydroperoxide (t-BHP) were used for the chemical stressors. The response of the QCM was monitored and analyzed with the resonance frequency and the resonance resistance (F-R) diagram. At the same time, the photographs of the cells were recorded to observe the morphological change. In the case of GA, the QCM responded in two steps which consisted of the rapid response of the cross-linking reactions and successive decreasing cytoskeletons in the cells. In the case of t-BHP, the response showed two steps. At first, the cells changed their shapes to round, and then the weakened cells were unsticked from the surface.  相似文献   

20.
An analysis of non-biotinylated camptothecin (CPT) binding to the C-20-biotinylated CPT binding peptide NSSQSARR was carried out using two methods, quartz-crystal microbalance (QCM) and surface plasmon resonance (SPR). The peptide was immobilized peptide on a sensor chip and showed a dissociation constant (KD) of approximately 0.1 microM against CPT in QCM and SPR experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号