首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
On-line detection of serum proteins is of clinical relevance, in detecting leaks and biofouling in hemofiltration equipment, biofilm growth on prosthetic devices, or hemolysis within a prosthetic or therapeutic device. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed to detect and analyze micromolar concentrations of four globular proteins of clinical importance. CV testing showed that identification and quantification of each of these proteins was possible through analysis of current changes at specific potentials. Preliminary CV studies into the contamination of Bovine Serum Albumin with a microgram amount of one of the other three proteins illustrated that direct detection of the contaminant protein was possible. The analysis of the EIS data demonstrated that with increase in relative concentration of proteins, the amount of electroactive proteins adsorption at the interface increases, leading to increase in surface charge density and capacitance, especially for lower molecular weight proteins. The impedance data was used to determine the values of Gibbs adsorption energy, adsorption coefficients for the four proteins, and develop an equivalent circuit model for the protein-containing solutions.  相似文献   

2.
Bioaffinity sensors need to be rapid, specific, and highly sensitive. To realize these features, electrodes that can elicit high electrochemical performance are necessary. In this study, we developed nanorod array electrode and performed cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) experiments to study the interfacial properties of the nanorod array electrode with Fe(CN)(6)(3-/4-) as the redox molecules. Results showed that both the CV and EIS measurements captured very well the resistive and capacitive changes due to the adsorption of functionalizing molecules and the coupling between avidin and biotin. The EIS measurements were more sensitive in discriminating small changes caused by the surface adsorption of various molecules. The use of avidin-functionalized gold nanorod modified electrodes had led to much increased detection sensitivity along with a detection-limit as low as 1 ng/mL of biotin.  相似文献   

3.
PorB class II from Neisseria meningitidis is a pore-forming, outer-membrane protein that can translocate to the host-cell membrane during Neisserial infections. This report describes development of tethered bilayer lipid membrane (tBLM) system to measure PorB conductance properties. The tBLM was fabricated by depositing a self-assembled monolayer of 1,2-dipalmitoyl-sn-glycero-3-phosphothioethanol (DPPTE) tethering lipid on a gold electrode and then using 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) liposomes to deposit the upper tBLM leaflet. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to monitor tBLM formation and subsequent PorB incorporation. The highly insulating tBLM exhibited a membrane resistance and capacitance of 2.5MOmegacm(2) and 0.7 microF/cm(2), respectively. PorB was incorporated into the tBLM in an active conformation, as evidenced by its mediation of ion passage and the decrease in membrane impedance. After PorB incorporation, the membrane resistance decreased to 0.6MOmegacm(2). As expected, the PorB channel was found to be non-selective, allowing the transport of both cations and anions. Cyclic voltammetry indicated that ferricyanide ions can also pass through the pores. The PorB-containing biomimetic interface developed in this study could potentially be used to screen for compounds that modulate PorB activity.  相似文献   

4.
A new current amplified immunosensor for the determination of carcinoembryonic antigen (CEA) was demonstrated in this work. The electrode architecture was fabricated by positively charged toluidine blue (TB) coated on negatively charged poly-sulfanilic acid (PSAA) modified glassy carbon electrode (GCE) surface through electrostatic interactions to form a TB/PSAA film, which provided an interface containing amine groups to assemble gold nanoparticles (nano-Au) for immobilization of carcinoembryonic antibody (anti-CEA) and horseradish peroxidase (HRP) instead of bovine serum albumin (BSA) to block sites against non-specific binding. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed to characterize the electrochemical properties of the modified processes. The CVs reduction current of the immunosensor charged linearly in two concentration ranges of CEA from 0.5 to 5.0 and 5.0 to 120.0 ng/ml in presence of 0.3mM H2O2 in analyte solution, and the detection limit was 0.2 ng/ml at three times background noise. The proposed method is economical, efficient and potentially attractive for clinical immunoassays.  相似文献   

5.
Immobilization of amyloid beta (Abeta) (1-40) peptide on Au-colloid modified gold electrodes has been studied. Colloidal Au was self-assembled onto gold electrodes through the thiol groups of 1,6-hexanedithiol monolayer. Next, buffered aqueous solution of Abeta (1-40) peptide existing in the beta-sheet structure in the acidic media was dropped on the electrode surface. Each step of electrode modification has been confirmed with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The changes of the resistance of the layer with deposited Abeta (1-40) peptide, occurred under stimulation by different concentration of (-) nicotine ditartrate and (-) cotinine were measured with EIS and were used for the calculation of association constants. The gentle measuring conditions applied in electrochemical impedance spectroscopy, together with suitable environment for biomolecules immobilization created by Au-colloid, might be recommended as the analytical tool for assessing the effectiveness of potential drugs used in Alzheimer's disease (AD) therapy.  相似文献   

6.
In this paper we describe the status of a silicon-based microelectrode for neural recording and an advanced neural interface. We have developed a silicon neural probe, using a combination of plasma and wet etching techniques. This process enables the probe thickness to be controlled precisely. To enhance the CMOS compatibility in the fabrication process, we investigated the feasibility of the site material of the doped polycrystalline silicon with small grains of around 50 nm in size. This silicon electrode demonstrated a favorable performance with respect to impedance spectra, surface topography and acute neural recording. These results showed that the silicon neural probe can be used as an advanced microelectrode for neurological applications.  相似文献   

7.
In this work, uniform and stable multi-walled carbon nanotubes (MWCT) and chemically reduced graphene (GR) composite electrode interface was fabricated by using layer-by-layer assembly method. The performances of these GR-MWCT assembled electrode interfaces were studied by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). It was demonstrated that the assembled composite film significantly improved the interfacial electron transfer rate compared with that of GR or MWCT modified electrode. Based on the GR-MWCT assembled interface, a sandwich-type electrochemical immunosensor was constructed using human IgG as a model target. In this assay, human IgG was fixed as the target antigen, the HRP-conjugated IgG as the probing antibody and hydroquinone as the electron mediator. The detection limit of the immunosensor was 0.2 ng mL(-1) (signal-to-noise ratio of 3). A good linear relationship between the current signals and the concentrations of Human IgG was achieved from 1 ng mL(-1) to 500 ng mL(-1). Moreover, this electrochemical immunosensor exhibited excellent selectivity, stability and reproducibility, and can be used to accurately detect IgG concentration in human serum samples. The results suggest that the electrochemical immunosensor based on GR-MWCT assembled composite will be promising in the point-of-care diagnostics application of clinical screening of multiple diseases.  相似文献   

8.
Most antimicrobial peptides (AMPs) have shown clear activity related to the disruption of lipid bilayers. In order to improve knowledge of this subject, the interaction of Magainin I (MagI) with phospholipid layers (PLs), uncoated or coated with synperonic (Synp), was studied using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and surface plasmon resonance (SPR) techniques. MagI peptide was immobilized on gold electrode via a self-assembling monolayer obtained from liposomes and liposomes covered by Synp. MagI induces pores in the supported lipid membranes, which are reflected in an increased amperometric-response and also a decreased electron-transfer resistance (R(CT)). In addition, MagI showed a significant interaction with the PL-Synp-modified gold electrode, but MagI showed a reliable contact with the PL-modified gold electrode, leading to a decrease in the relative resistance charge transfer value of -17.38%. Our results demonstrated that Synp acts as a membrane sealant after exposure of the lipid membrane to MagI. A parallel reaction model was proposed for the interaction of MagI and a hybrid layer that result in a complex bimolecular interaction. In short, the importance of triblock copolymer to stabilize liposomes for future applications as drug delivery systems for MagI was demonstrated.  相似文献   

9.
Diglycolic acid (DA) polymer was coated on glassy carbon (GC) electrode by cyclic voltammetry (CV) technique for the first time. The electrochemical performances of the modified electrode were investigated by CV and electrochemical impedance (EIS). The obtained electrode showed an excellent electrocatalytic activity for the oxidation of acetaminophen (ACOP). A couple of well-defined reversible electrochemical redox peaks were observed on the ploy(DA)/GC electrode in ACOP solution. Compared with bare GC electrode, the oxidation peak potential of ACOP on ploy(DA)/GC electrode moved from 0.289 V to 0.220 V. Meanwhile, the oxidation peak current was much higher on the modified electrode than that on the bare GC electrode, indicating DA polymer modified electrode possessed excellent performance for the oxidation of ACOP. This kind of capability of the modified electrode can be enlisted for the highly sensitive and selective determination of ACOP. Under the optimized conditions, a wide linear range from 2 × 10(-8) to 5.0 × 10(-4)M with a correlation coefficient 0.9995 was obtained. The detection limit was 6.7 × 10(-9)M (at the ratio of signal to noise, S/N=3:1). The modified electrode also exhibited very good stability and reproducibility for the detection of ACOP. The established method was applied to the determination of ACOP in samples. An average recovery of 100.1% was achieved. These results indicated that this method was reliable for determining ACOP.  相似文献   

10.
An electrochemical impedimetric immunosensor was developed for ultrasensitive determination of insulin-like growth factor-1 (IGF-1) based on immobilization of a specific monoclonal antibody on gold nanoparticles (GNPs) modified gold electrode. Self-assembly of colloidal gold nanoparticles on the gold electrode was conducted through the thiol groups of 1,6-hexanedithiol (HDT) monolayer as a cross linker. The redox reactions of [Fe(CN)(6)](4-)/[Fe(CN)(6)](3-) on the electrode surface was probed for studying the immobilization and determination processes, using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The interaction of antigen with grafted antibody recognition layer was carried out by soaking the modified electrode into antigen solution at 37°C for 3 h. The immunosensor showed linearity over 1.0-180.0 pg mL(-1) and the limit of detection was 0.15 pg mL(-1). The association constant between IGF-1 and immobilized antibody was calculated to be 9.17×10(11) M(-1). The proposed method is a useful tool for screening picogram amounts of IGF-1 in clinical laboratory as a diagnostic test.  相似文献   

11.
A novel potentiometry immunoassay with amplified sensitivity has been developed for the detection of diphtheria antigen (Diph) via immobilizing diphtheria antibody (anti-Diph) on a platinum electrode based on Nafion, colloidal Ag (Ag), and polyvinyl butyral (PVB) as matrixes in this study. The modified procedure was further characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The influence and factors influencing the performance of resulting immunosensor were studied in detail. The resulting immunosensor exhibited sigmoid curve with log Diph concentrations, high sensitivity (51.4 mV/decade), wide linear range from 8 to 800 ng ml(-1) with a detection limit of 1.5 ng ml(-1), rapid potentiometric response (<3 min) and long-term stability (>6 months). Analytical results of clinical samples show that the developed immunoassay is comparable with the enzyme-linked immunosorbent assays (ELISAs) method, implying a promising alternative approach for detecting diphtheria antigen in the clinical diagnosis.  相似文献   

12.
We demonstrated a simple and efficient strategy, which based on the enzymatically biocatalytic precipitates amplified antibody-antigen interaction, for improving the response signals of surface plasmon resonance (SPR) immunosensing. The antibody-antigen-alkaline phosphatase (AP) labeled secondary antibody sandwich were successfully prepared and characterized by SPR, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The SPR signal amplification was accomplished through probing resonance angle shift and Faradaic electron impedance of [Fe(CN)(6)](3-/4-) redox pair after the enzymatically biocatalytic products precipitating on the immunosensing electrode surface. As a result, the accumulation of the enzymatically biocatalytic precipitates leads to significantly resonance angle shift and increase of electron transfer impedance of [Fe(CN)(6)](3-/4-) probe. The precipitates-enhanced sandwich SPR immunoassay for mouse immunoglobulin G (m-IgG) can easily detect solution protein concentrations in the linear range of 0.02-40 ng mL(-1) and with a detection limit of 200 fg mL(-1), which is more than four-orders and 10 times better compared with the values using streptavidin-biotinylated protein complex and biotinylated HRP biocatalyzation amplification methods. Moreover, this method is generally applicable to other sandwich immunoassays and also can be expanded to monitor other antibody-antigen interaction for immunosensing detection at low concentrations.  相似文献   

13.
We have developed a simple and renewable electrochemical biosensor based on carbon paste electrode (CPE) for the detection of DNA synthesis and hybridization. CPE was modified with gold nanoparticles (AuNPs), which are helpful for immobilization of thiolated bioreceptors. AuNPs were characterized by scanning electron microscopy (SEM). Self-assembled monolayers (SAMs) of thiolated single-stranded DNA (SH–ssDNA) of the amelogenin gene was formed on CPE. The immobilization of the probe and its hybridization with the target DNA was optimized using different experimental conditions. The modified electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The electrochemical response of ssDNA hybridization and DNA synthesis was measured using differential pulse voltammetry (DPV) with methylene blue (MB) as an electroactive indicator. The new biosensor can distinguish between complementary and non-complementary strands of amelogenin ssDNA. Genomic DNA was extracted from blood and was detected based on changes in the MB reduction signal. These results demonstrated that the new biosensor could be used for sex determination. The proposed biosensor in this study could be used for detection and discrimination of polymerase chain reaction (PCR) products of amelogenin DNA.  相似文献   

14.
A new biosensor employing immobilized DNA on a nano-structured conductive polymer fixed onto a platinum electrode is presented. Upon optimization of synthesis parameters, polypyrrole nanofibers, 30-90 nm in diameter, were synthesized in an aqueous media by the electropolymerization of pyrrole using normal pulse voltammetry (NPV). The nanofiber film was investigated by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Double-stranded DNA was physisorbed onto the PPy nanofiber films. Various parameters, including the pH and DNA concentration, were optimized. The DNA immobilized on the nanofiber films was characterized using differential pulse voltammetry (DPV) and Fourier-transform infrared (FTIR) spectroscopy. Using DPV to study the interaction of spermidine with DNA, a binding constant (K) value of 4.08 x 10(5)+/-0.05 M(-1) was obtained. For the determination of spermidine, the proposed method exhibited a good dynamic range, correlation coefficient (0.05-1.0 microM and 0.9983, respectively) and a low detection limit (0.02 microM), although Ca(2+) ions were found to electrostatically bind to DNA and weaken the spermidine-DNA interaction.  相似文献   

15.
The current study describes the electrografting of 2,4-diamino-1,3,5-triazine (AT) groups at the surfaces of glassy carbon electrode (GCE) and indium tin oxide (ITO) through in situ diazotization of melamine. The presence of AT groups at the surface of the electrode was confirmed by X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Furthermore, graphene oxide (GO) was self-assembled on AT grafted GCE. The oxygen functional groups present on the surface of GO were electrochemically reduced to form an electrochemically reduced graphene oxide (ERGO) on AT grafted electrode surface. Raman spectra show the characteristic D and G bands at 1340 and 1605 cm−1, respectively, which confirms the successful attachment of GO on AT grafted surface, and the ratio of D and G bands was increased after the electrochemical reduction of GO. EIS shows that the electron transfer reaction of [Fe(CN)6]3−/4− was higher at the ERGO modified electrode than at bare, AT grafted, and GO modified GCEs. The electrocatalytic activity of ERGO was investigated toward the oxidation of methylxanthines. It shows excellent electrocatalytic activity toward these methylxanthines by not only shifting their oxidation potentials toward less positive potentials but also enhancing their oxidation currents.  相似文献   

16.
Commercial enzymes, creatininase (CA) from Pseudomonas sp, creatinase (CI) from Pseudomonas sp, sarcosine oxidase (SO) from Bacillus sp were co-immobilized onto iron oxide nanoparticles/chitosan-graft-polyaniline (Fe(3)O(4)-NPs/CHIT-g-PANI) composite film electrodeposited on surface of Pt electrode through glutaraldehyde coupling. Transmission electron microscopy (TEM) was used for characterization of Fe(3)O(4)-NPs. A creatinine biosensor was fabricated using Enzymes/Fe(3)O(4)-NPs/CHIT-g-PANI/Pt electrode as working electrode, Ag/AgCl as reference electrode and Pt wire as auxiliary electrode. The enzyme electrode was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopic and electrochemical impedance spectroscopy (EIS). The biosensor exhibited an optimum response within 2s at pH 7.5 and 30 °C, when polarized at 0.4V vs Ag/AgCl. The electrocatalytic response showed a linear dependence on creatinine concentration ranging from 1 to 800 μM. The sensitivity of the biosensor was 3.9 μA μM(-1) cm(-2), with a detection limit of 1 μM (S/N=3). Apparent Michaelis-Menton (K(m)) value for creatinine was 0.17 mM. The biosensor showed only 10% loss in its initial response after 120 uses over 200 days, when stored at 4 °C. The biosensor measured creatinine in the serum of apparently healthy persons which correlated well with a standard colorimetric method (r=0.99).  相似文献   

17.
A new silver nanoparticles (AgNPs)/carboxylated multiwalled carbon nanotubes (c-MWCNT)/polyaniline (PANI) film has been synthesized on Au electrode using electrochemical techniques. The enzyme glutathione oxidase (GSHOx) (EC 1.8.3.3) was immobilized covalently on the surface of AgNPs/c-MWCNT/PANI/Au electrode to construct the glutathione biosensor. The modified electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and Fourier transform infrared (FTIR) spectrophotometry. The biosensor showed optimum response within 4s at +0.4V vs. Ag/AgCl, pH 6.0 and 35 °C, with a linear working range of 0.3-3500 μM and a detection limit of 0.3 μM. The glutathione biosensor was employed for measurement of glutathione content in hemolysated erythrocyte (RBC). The sensor was evaluated with 97.77% and 99.16% recovery of added glutathione in hemolysated RBC and 2.4% and 6.3% within and between batch coefficients of variation (CVs) respectively. The enzyme electrode lost 50% of its initial activity after 300 uses over a period of 3 months, when stored at 4 °C. The biosensor has the advantages over earlier biosensors in terms of greater stability, lower response time and no interference by a number of RBC hemolysate substances.  相似文献   

18.
Zinc oxide nanoparticles (ZnO-NPs) were synthesized from zinc nitrate by simple and efficient method in aqueous media at 55°C without any requirement of calcinations step. A mixture of ZnO-NPs and pyrrole was eletropolymerized on Pt electrode to form a ZnO-NPs-polypyrrole (PPy) composite film. Xanthine oxidase (XOD) was immobilized onto this nanocomposite film through physiosorption. The ZnO-NPs/polypyrrole/Pt electrode was characterized by Fourier transform infrared (FTIR), cyclic voltammetry (CV), X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and electrochemical impedance spectroscopy (EIS) before and after immobilization of XOD. The XOD/ZnO-NPs-PPy/Pt electrode as working electrode, Ag/AgCl as reference electrode and Pt wire as auxiliary electrode were connected through a potentiostat to construct a xanthine biosensor. The biosensor exhibited optimum response within 5s at pH 7.0, 35°C and linearity from 0.8 μM to 40 μM for xanthine with a detection limit 0.8 μM (S/E=3). Michaelis Menten constant (K(m)) for xanthine oxidase was 13.51 μM and I(max) 0.071 μA. The biosensor measured xanthine in fish meat and lost 40% of its initial activity after its 200 uses over 100 days, when stored at 4°C.  相似文献   

19.
Epinephrine (EP) is one of the key neurotransmitter, which plays a vital role in the central nervous system. Current research report designates the development of biosensor based on the modification of glassy carbon electrode (GCE) with multi walled carbon nano tubes (MWCNTs) followed by drop casting of Tyrosinase (Ty) enzyme (Ty/MWCNTs/GCE) towards the sensitive monitoring of EP. The electrochemical behavior of EP at Ty/MWCNTs/GCE biosensor was examined and the redox mechanism was proposed. The developed Ty/MWCNTs/GCE was characterized by electrochemical techniques such as cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and tafel plot studies. The influence of pH of phosphate buffer solution (PBS) on the electrochemical redox behavior of EP was observed and pH-7.0 was identified as optimal pH value. The electrochemical kinetic parameters such as heterogeneous rate constant, diffusion coefficient and charge transfer coefficient values were evaluated. The limit of detection and limit of quantification values were evaluated. The low apparent Michaelis – Menten constant (Kmapp) was determined as 0.159 mM, demonstrating the immense catalytic activity of Ty enzyme. Repeatable, reproducible and stable nature of the fabricated Ty/MWCNTs/GCE was successfully examined. Finally, the developed biosensor was tested for the practical application in quantification of EP in human serum samples.  相似文献   

20.
Recent neuropsychological research has begun to reveal that neurons encode information in the timing of spikes. Spiking neural network simulations are a flexible and powerful method for investigating the behaviour of neuronal systems. Simulation of the spiking neural networks in software is unable to rapidly generate output spikes in large-scale of neural network. An alternative approach, hardware implementation of such system, provides the possibility to generate independent spikes precisely and simultaneously output spike waves in real time, under the premise that spiking neural network can take full advantage of hardware inherent parallelism. We introduce a configurable FPGA-oriented hardware platform for spiking neural network simulation in this work. We aim to use this platform to combine the speed of dedicated hardware with the programmability of software so that it might allow neuroscientists to put together sophisticated computation experiments of their own model. A feed-forward hierarchy network is developed as a case study to describe the operation of biological neural systems (such as orientation selectivity of visual cortex) and computational models of such systems. This model demonstrates how a feed-forward neural network constructs the circuitry required for orientation selectivity and provides platform for reaching a deeper understanding of the primate visual system. In the future, larger scale models based on this framework can be used to replicate the actual architecture in visual cortex, leading to more detailed predictions and insights into visual perception phenomenon.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号