首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A new sensitive high-performance liquid chromatographic (HPLC) method with fluorescence detection was developed for the determination of 2-phenylethylamine (PEA) in human urine. The analytical procedure involved a simple extraction of the analyte from urine, followed by precolumn derivatisation of the sample with o-phthalaldehyde. The HPLC separation was performed under isocratic conditions using an Erbasil S C18 (250 × 4.0 mm I.D., particle size 3 μm) reversed-phase column. The limit of quantification was 0.5 ng of PEA/ml of urine. The method showed good linearity, accuracy and precision data in the concentration range 0.5–200 ng/ml of urine. The method was successfully applied to the determination of PEA urinary excretion in Parkinsonian patients after oral administration of the monoamine oxidase B (MAO-B) inhibitor, selegiline.  相似文献   

3.
An isocratic HPLC method was developed and validated for the quantitation of methocarbamol in human plasma. Methocarbamol and internal standard in 200 μl of human plasma were extracted with ethyl acetate, evaporated to dryness and reconstituted in water. Separation was achieved on a reversed-phase C18 column with a mobile phase of methanol—0.1 M potassium phosphate monobasic—water (35:10:55, v/v/v). The detection was by ultraviolet at 272 nm. Linearity was established at 1–100 μg/ml (r > 0.999). The limit of quantitation was designed as 1 μg/ml to suit pharmacokinetic studies. Inter-day precision and accuracy of the calibration standards were 1.0 to 3.6% coefficients of variance (C.V.) and −2.0 to +1.6% relative error (R.E.). Quality controls of 3, 20 and 70 μg/ml showed inter-day precision and accuracy of 2.5 to 3.6% C.V. and −0.9 to −0.4% R.E. Recovery of methocarbamol was 91.4–100.3% in five different lots of plasma. The method was shown to be applicable on different brands of C18 columns.  相似文献   

4.
A simple and reliable HPLC method for quantitative determination of pseudouridine and uric acid in human urine and serum using a cation-exchange resin is described. This method is straightforward (12 runs of urine samples per day since the sample is only diluted into buffer and then chromatographed), sensitive, and highly reproducible. The column is stable over long periods (3 months of uninterrupted use at a time; it is thereafter easily restored to the original state). Mean excretion values for pseudouridine (in μmol/mmol creatinine) are 26.4 ± 3.1 (17 female adults), 23.8 ± 2.5 (12 male adults), 164.7 ± 32.2 (37 male preterm infants); mean values for uric acid (μmol/mmol creatinine) are, respectively, 310.3 ± 90.5, 278.2 ± 56.1, and 1108 ± 314. Human serum is deproteinized by pressure ultrafiltration in microcollodion bags with a nominal exclusion molecular weight of 12,400 and then put directly onto the HPLC column. The complete procedure takes 4 h.  相似文献   

5.
A reversed-phase HPLC method with fluorescence detection was evaluated for utility in determination of urinary metabolites of polycyclic aromatic hydrocarbons as biomarkers of environmental exposure. The method, which was developed for use in studies of high-level occupational exposure, was found to be unreliable for relatively low-level environmental exposures. The method was modified to include quantitation by standard addition in order to compensate for matrix effects at levels as low as 0.1 ng/ml. The standard addition modification increased both qualitative and quantitative performance, with recovery of 1-hydroxypyrene spikes improved from 164% to 114% at 0.36 ng/ml. The modified method was successfully applied in an environmental exposure study.  相似文献   

6.
A method based on solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) was developed for the simultaneous determination of 3-(3,5-diclorophenyl)-5-ethenyl-5-methyl-2,4-oxazolidinedione (vinclozolin) and 3-(3,5-diclorophenyl)-N-(1-methylethyl)-2,4-dioxo-1-imidazolidinecarboxamide (iprodione) in human urine. Urine samples containing vinclozolin and iprodione were collected by solid phase extraction using C(18) cartridges. The chromatographic separation was achieved on a Spherisorb ODS2 (250 mm x 4.6 mm, 5 microm) column with an isocratic mobile phase of acetonitrile-water (60:40, v/v). Detection was UV absorbance at 220 nm. The calibration graphs were linear from 30 to 1000 ng/mL for the two fungicides. Intra- and inter-day R.S.D. did not exceed 2.9%. The quantitation limit was 50 ng/mL for vinclozolin and 30 ng/mL for iprodione, respectively.  相似文献   

7.
A modification of the Bio-Rad total homocysteine HPLC-test is presented in order to enable not only plasma homocysteine measurements but also the quantification of homocysteine in urine samples using the same principle of measurement. Coelution of the internal standard provided in the test kit with an endogenous compound in urine demands for an alternative analytical procedure. Therefore, we introduced 3-mercaptopropionic acid as a substitute for the internal standard. The analytical method validation was performed for the matrix of urine specimens. The applicability of this method was demonstrated in a clinical study with volunteers after homocysteine thiolactone hydrochloride loading.  相似文献   

8.
A rapid and sensitive method for quantitative determination of cystatin C (CC) protein in human urine via HPLC was developed and validated. Acetone has been used as a precipitating agent of CC protein from the urine biological matrix. Separation and detection were accomplished by ion pair liquid chromatography and UV detection. Gradient elution mode was utilized to elute CC with a UV detection of 224 nm. The analysis time was 14 min per sample using Ace C8 (150 × 4.6 mm i.d., 5 μm) as a chromatographic column with a flow rate of 1.0 mL/min. Calibration curve with good linearity (r2 = 0.99) within the range from 0.390 to 0.001 mg/mL was obtained. Limits of detection and quantification were 0.001 and 0.002 mg/mL, respectively. Inter-assay and intra-assay variabilities were <15% for all levels and <20% at the limit of quantification level. Major advantages of the method: specific where no false positive results might be obtained and fast where sample pretreatment needs only 1 h.  相似文献   

9.
A rapid and specific method for the determination of iodide in urine by high-performance liquid chromatography on an anion-exchange column with electrochemical detection is described. The assay is reproducible as judged by the coefficient of variation of less than 4% at all concentrations used. The limit of detection was 0.1 μ mol, and the calibration graph was linear for concentrations between 0.1 and 200 μmol. Using this method, healthy volunteers were found to excrete 69±39 μmol of iodide per mole of creatinine.  相似文献   

10.
Polyethylene glycols (PEGs) are non-ionic, water-soluble synthetic polymers which have been widely used for many applications. Since they are of very low toxicity and are readily excreted in urine, PEGs in the molecular weight range 400–6000 have been used extensively in the study of intestinal physiology in man. A high-performance liquid chromatographic (HPLC) method has been developed for the determination of PEG 600 in human urine, which includes a pre-column derivatisation step. The dibenzoate derivatives of PEG 600 can be quantitatively prepared, and this, coupled with ultraviolet detection at 230 nm, has greatly improved the limit of detection for the determination of PEGs by HPLC. A suitable extraction procedure has also been developed which enabled PEG levels in urine to be monitored with much greater sensitivity than any previously reported method.  相似文献   

11.
A method is described for the determination of urinary hippuric acid by high-performance liquid chromatography. The method used ethyl acetate extraction for partial clean-up of the urine. The separation was carried out on a reversed-phase column using 20% methanol in 0.01 M aqueous potassium phosphate containing 0.5% acetic acid as a mobile phase. The column effluent was monitored with a UV detector at 254 nm. Hippuric acid was separated from other normal urine constituents in less than 10 min. Metabolites of xylene and styrene did not interfere with the assay. Analytical recoveries from urine were excellent and peak height and concentration were linearly related.  相似文献   

12.
A high-performance liquid chromatographic method has been developed for the determination of pipotiazine in human plasma and urine. After selective extraction, pipotiazine and the internal standard (7-methoxypipotiazine) are chromatographed on a column packed with Spherosil XOA 600 (5 μm) using a 7:3 (v/v) mixture of diisopropyl ether—isooctane (1:1, v/v) + 0.2% triethylamine and diisopropyl ether—methanol (1:1, v/v) + 0.2% triethylamine + 2.6% water. The eluted compounds are measured by fluorescence detection. The sensitivity of the method was established at 0.25 ng/ml pipotiazine in plasma and 2 ng/ml pipotiazine in urine (C.V. < 5%). The method has been successfully applied to a pharmacokinetic study following a single oral administration of 10 mg of pipotiazine.  相似文献   

13.
14.
A column-switching, reversed-phase high-performance liquid chromatographic (HPLC) assay for a new structurally unique carbapenem antibiotic, ertapenem, in urine has been improved for selectivity and automated using a Packard MultiPROBE II EX pipetting station. The method uses column-switching for on-line extraction of the urine sample. The extraction column, analytical column, mobile phase, and timing of the column-switching valve have been changed to enhance selectivity for the analyte over endogenous background material. Sample transfer and dilution prior to direct-injection into the HPLC system have been accomplished using a Packard MultiPROBE II EX robotic liquid handling system.  相似文献   

15.
A simple robust high-performance liquid chromatographic method is described for the determination of ranitidine in microvolumes of human serum. The drug of interest was isolated using liquid–liquid extraction with dichloromethane and back-extraction with 0.1% phosphoric acid and separation was obtained using a reversed-phase column under isocratic conditions, with ultraviolet detection at 313 nm. Intra-day and inter-day coefficients of variation ranged from 1 to 6% and 3 to 10%, respectively. Accuracy of the assay was less than 10% at all concentrations. The limit of detection and the limit of quantitation were 2 and 7 ng/ml, respectively. The linearity was assessed in the range 10–1000 ng/ml. It was shown that a group of common drugs co-administered with ranitidine did not interfere with its determination. The applicability of this method for the pharmacokinetic study of ranitidine following i.v. infusion in patients was demonstrated using only 100 μl of serum. The ruggedness of the assay was demonstrated over a three-year period.  相似文献   

16.
Application of the gas—liquid chromatographic method previously reported by us was made to the analysis of the 22 amino acids including asparagine and glutamine in serum. The method permitted that aqueous serum samples obtained after deproteinization with perchloric acid were directly subjected to derivatization without any further clean-up procedure such as ion-exchange chromatography. The N-ethyloxycarbonyl methyl esters, which were prepared in the same manner as the N-isobutyloxycarbonyl methyl esters, were introduced for the determination of leucine, isoleucine, arginine and tyrosine. Both derivatives were prepared by two-step procedures involving alkyloxycarbonylation in aqueous media and esterification with diazomethane, and simultaneously analyzed by using the dual set of columns with the same thermal conditions. The advantages of this method are that the sample pretreatment and derivatization are very simple and rapid, and that both asparagine and glutamine along with other amino acids in serum can be determined.  相似文献   

17.
A validated gas chromatography (GC)-mass spectrometric (MS) method for the analysis of hydroxyproline in rat femur is reported. Hydroxyproline in bone hydrolysates was extracted with an anion exchange resin and the N(O)-tert-butyldimethylsilyl derivatives analyzed by GC-MS. The hydroxyproline concentration was estimated relative to pipecolic acid, 3,4-dehydroproline and n-tetracosane as internal standards. The mass-to-charge ratios (m/z) for the ions used for quantitation by single ion monitoring were 314 m/z for hydroxyproline, 198 m/z for pipecolic acid, 256 m/z for dehydroproline and 57 m/z for n-tetracosane. A coefficient of variation of 5.8% was achieved and the limit of detection was calculated to be 0.233 micromol/l bone hydrolysate.  相似文献   

18.
19.
An automated HPLC method is described for the determination of nedocromil sodium in human urine. An HPLC autosampler is used to inject urine samples onto a short reversed-phase column. This column acts as a concentration column and performs a preliminary extraction. The concentration column is automatically backflushed onto an ion-exchange column where final separation of nedocromil sodium from urine constituents occurs. Recovery, accuracy, precision, sensitivity and specificity were investigated. The method has been applied to urine samples from clinical studies, and the results were compared to those obtained using a radioimmunoassay developed previously.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏