首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到6条相似文献,搜索用时 15 毫秒
1.
Erythromycin is determined in both urine and plasma samples using microbore reversed-phase liquid chromatography with tris(2,2′-bipyridyl)ruthenium(II) [Ru(bpy)32+] electrogenerated chemiluminescence (ECL) detection. Ru(bpy)32+ is included in the mobile phase thus eliminating band broadening caused by post-column reagent addition. Extra column band broadening is an important concern in microbore liquid chromatography due to the small peak volumes. Erythromycin was studied in both water and biological samples. The detection limit for erythromycin in standards is 0.01 μM or 50 fmol injected with a S/N of 3 and a linear working range that extends four orders of magnitude. Human urine and blood plasma were also studied. Urine samples were diluted and filtered before injection. Ultrafiltration was used to remove protein from blood plasma samples prior to injection. Erythromycin was selectively detected in the body fluid samples without any further sample preparation. The detection limits obtained for erythromycin in urine and plasma are 0.05 and 0.1 μM, respectively, for 5 μl injected on a 150×1 mm I.D. C18 column.  相似文献   

2.
A method for the determination of acetylcholine (ACh) has been developed using liquid chromatography with chemiluminescence detection. This method is based on the pre‐column alkaline cleavage of ACh to form trimethylamine (TMA) and the post‐column tris(2,2′‐bipyridyl)ruthenium(III) chemiluminescence detection of TMA. ACh was converted to TMA with high yield at 180°C in the presence of lithium hydroxide, and the produced TMA was separated on a cation‐exchange/reversed‐phase dual‐functional column using a mixture of 0.2 m potassium phosphate buffer (pH 5.9) and acetonitrile (20:1, v/v) as the mobile phase. The eluate was online mixed with acidic tris(2,2′‐bipyridyl)ruthenium(III) solution, and the generated chemiluminescence was detected. The detection limit (signal‐to‐noise ratio = 3) for ACh was 0.80 nmol/mL, which corresponded to 1.1 pmol TMA per injection volume of 5 µL. This is simple and robust method that does not need an expensive device and unstable enzymes, and was applied to the determination of ACh in pharmaceutical formulations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A simple, rapid and sensitive chemiluminescent (CL) method for the assay of venlafaxine (VEN) in pharmaceutical formulations and serum samples by a two‐chip device is proposed. The method is based on the reaction of this drug with a tris(2,2′‐bipyridyl) ruthenium(II)–peroxydisulphate CL system. The optimum chemical conditions for CL emission were investigated. The calibration graph was linear for the concentration range 0.02–8.0 µg/mL. The detection and quantification limits were found to be 0.006 and 0.018 µg/mL, respectively, while the relative standard deviation (RSD) was <2.0%. The present CL procedure was applied to the determination of VEN in pharmaceutical formulations and serum samples; the recovery levels were in the range 96.5–101.2%. The results suggest that the method is unaffected by the presence of common formulation excipients found in these samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
A highly sensitive pre-column HPLC method for simultaneous determination of prolyl dipeptides, Pro and Hyp in urine was developed. The analytes were labelled with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride at 70°C for 20 min. The derivatives separated on tandem reversed-phase columns by a gradient elution and were monitored with fluorescence detection at 318 nm (excitation) and 392 nm (emission). The detection limits for prolyl dipeptides, Pro and Hyp were 1–5 fmol/injection (S/N=3). Urine samples were treated with o-phthalaldehyde, followed by purification on a Bond Elut C18 column before conducting the labelling reaction. Pro–Hyp, Pro–Gly and Pro–Pro were identified as prolyl dipeptides in urine. The within-day and between-day relative standard deviations were 1.5–4.8 and 1.7–5.8%, respectively. The concentrations of Pro–Hyp, Pro–Gly, Pro–Pro, Pro and Hyp in normal human urine were 97.6±28.2, 2.74±1.48, 2.08±1.13, 6.71±3.34 and 2.30±1.59 nmol/mg creatinine, respectively.  相似文献   

5.
A simple and sensitive electrochemiluminescence (ECL) method for the determination of etamsylate has been developed by coupling an electrochemical flow‐through cell with a tris(2,2'‐bipyridyl)ruthenium(II) (Ru(bpy)32+)–Nafion‐modified carbon electrode. It is based on the oxidized Ru(bpy)32+ on the electrode surface reacting with etamsylate and producing an excellent ECL signal. Under optimized experimental conditions, the proposed method allows the measurement of etamsylate over the range of 8–1000 ng/mL with a correlation coefficient of r = 0.9997 (n = 7) and a limit of detection of 1.57 ng/mL (3σ), the relative standard deviation (RSD) for 1000 ng/mL etamsylate (n = 7) is 0.96%. The immobilized Ru(bpy)32+ carbon paste electrode shows good electrochemical and photochemical stability. This method is rapid, simple, sensitive and has good reproducibility. It has been successfully applied to the determination of the studied etamsylate in pharmaceutical preparations with satisfactory results. The possible ECL reaction mechanism has also been discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
[Arg6, -Trp7,9, mePhe8]-substance P (6–11), code-named antagonist G, is a novel peptide currently undergoing early clinical trials as an anticancer drug. A sensitive, high efficiency high-performance liquid chromatography (HPLC) method is described for the determination in human plasma of antagonist G and its three major metabolites, deamidated-G (M1), G-minus Met11 (M2) and G[Met11(O)] (M3). Gradient elution was employed using 40 mM ammonium acetate in 0.15% trifluoroacetic acid as buffer A and acetonitrile as solvent B, with a linear gradient increasing from 30 to 100% B over 15 min, together with a microbore analytical column (μBondapak C18, 30 cm×2 mm I.D.). Detection was by UV at 280 nm and the column was maintained at 40°C. Retention times varied by <1% throughout the day and were as follows: G, 13.0 min; M1, 12.2 min; M2, 11.2 min; M3, 10.8 min, and 18.1 min for a pyrene conjugate of G (G–P). The limit of detection on column (LOD) was 2.5 ng for antagonist G, M1–3 and G–P and the limit of quantitation (LOQ) was 20 ng/ml for G and 100 ng/ml for M1–3. Sample clean-up by solid-phase extraction using C2-bonded 40 μm silica particles (Bond Elut, 1 ml reservoirs) resulted in elimination of interference from plasma constituents. Within-day and between-day precision and accuracy over a broad range of concentrations (100 ng/ml–100 μg/ml) normally varied by <10%, although at the highest concentrations of M1 and M2 studied (50 μg/ml), increased variability and reduced recovery were observed. The new assay will aid in the clinical development of antagonist G.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号