1.
Experimental data (Thornton et al., 1997) show that relaxation proceeds more rapidly (a greater slope on a log-log scale) than creep in ligament, a fact not explained by linear viscoelasticity. An interrelation between creep and relaxation is therefore developed for ligaments based on a single-integral nonlinear superposition model. This interrelation differs from the convolution relation obtained by Laplace transforms for linear materials. We demonstrate via continuum concepts of nonlinear viscoelasticity that such a difference in rate between creep and relaxation phenomenologically occurs when the nonlinearity is of a strain-stiffening type, i.e., the stress-strain curve is concave up as observed in ligament. We also show that it is inconsistent to assume a Fung-type constitutive law (Fung, 1972) for both creep and relaxation. Using the published data of Thornton et al. (1997), the nonlinear interrelation developed herein predicts creep behavior from relaxation data well (R > or = 0.998). Although data are limited and the causal mechanisms associated with viscoelastic tissue behavior are complex, continuum concepts demonstrated here appear capable of interrelating creep and relaxation with fidelity.  相似文献   

2.
The present study examines the viscoelastic behavior of cancellous bone at low strains and the effects of damage on this viscoelastic behavior. It provides experimental evidence of interaction between stress relaxation behavior and the effect of accumulated damage. The results suggest that damage is at least orthotropic in trabecular bone specimens under uniaxial loading. Simple linear models of viscoelasticity described the time-dependent stress-strain behavior at low strains before and after specimen damage, although better fits of these models were obtained prior to damage. Modeling the observed changes in relaxation times with damage accumulation appears necessary to successfully predict the post-damage viscoelastic response.  相似文献   

3.
A F Mak 《Biorheology》1986,23(4):371-383
A biphasic poroviscoelastic theory was used to analyze the unconfined compression creep and stress relaxation of a hydrated viscoelastic tissue. The intrinsic shear properties of the tissue matrix was described by an integral-type viscoelastic constitutive law while the intrinsic bulk property of the matrix was assumed to be linearly elastic. Parametric data were presented to show how the two major energy dissipative mechanisms, namely the interstitial fluid flow and the intrinsic matrix viscoelasticity, may each contribute to the apparent viscoelastic behavior of the whole tissue under unconfined compression. The hydraulic permeability of the tissue was found to enter in only as a scaling factor for time.  相似文献   

4.
Time-dependent deformation of porcine skin was studied in vitro using specialized microprobe instruments. The deformation behavior of stratum corneum, dermis, and whole skin is examined in the context of results of creep strain, elastic stiffness, and viscoelastic constants obtained in terms of the hold time, loading/unloading rate, and maximum indentation depth (load). Skin time-dependent deformation is significantly influenced by dermis viscoelasticity up to a critical indentation depth (load) beyond which it is controlled by the outermost hard epidermis, particularly stratum corneum. Skin viscoelastic behavior under constant load (creep) and constant displacement (stress relaxation) is interpreted in the light of phenomenological observations and experimental trends.  相似文献   

5.
Articular cartilage was modeled rheologically as a biphasic poroviscoelastic material. A specific integral-type linear viscoelastic model was used to describe the constitutive relation of the collagen-proteoglycan matrix in shear. For bulk deformation, the matrix was assumed either to be linearly elastic, or viscoelastic with an identical reduced relaxation spectrum as in shear. The interstitial fluid was considered to be incompressible and inviscid. The creep and the rate-controlled stress-relaxation experiments on articular cartilage under confined compression were analyzed using this model. Using the material data available in the literature, it was concluded that both the interstitial fluid flow and the intrinsic matrix viscoelasticity contribute significantly to the apparent viscoelastic behavior of this tissue under confined compression.  相似文献   

6.
《Biorheology》1998,35(3):171-191
Cheese viscoelasticity is commonly measured using steady uniaxial compression, steady uniaxial extension, shear and compressive creep, and stress relaxation in shear and compression. Viscoelastic properties for many cheeses have also been studied using small amplitude oscillatory shear (SAOS). However, there is little on the measurement of nonlinear viscoelastic properties. The large deformation test usually conducted on cheese to study nonlinear viscoelasticity is uniaxial compression, but this test hardly departs from linear behavior. In this work, the nonlinear viscoelasticity of four cheese varieties was studied using large amplitude oscillatory shear (LAOS). A sliding plate rheometer incorporating a shear stress transducer was used. The data were evaluated using spectral analysis, and results are presented mainly in the form of shear stress versus shear rate loops.  相似文献   

7.
Li LP  Herzog W 《Biorheology》2004,41(3-4):181-194
The relative importance of fluid-dependent and fluid-independent transient mechanical behavior in articular cartilage was examined for tensile and unconfined compression testing using a fibril reinforced model. The collagen matrix of articular cartilage was modeled as viscoelastic using a quasi-linear viscoelastic formulation with strain-dependent elastic modulus, while the proteoglycan matrix was considered as linearly elastic. The collagen viscoelastic properties were obtained by fitting experimental data from a tensile test. These properties were used to investigate unconfined compression testing, and the sensitivity of the properties was also explored. It was predicted that the stress relaxation observed in tensile tests was not caused by fluid pressurization at the macroscopic level. A multi-step tensile stress relaxation test could be approximated using a hereditary integral in which the elastic fibrillar modulus was taken to be a linear function of the fibrillar strain. Applying the same formulation to the radial fibers in unconfined compression, stress relaxation could not be simulated if fluid pressurization were absent. Collagen viscoelasticity was found to slightly weaken fluid pressurization in unconfined compression, and this effect was relatively more significant at moderate strain rates. Therefore, collagen viscoelasticity appears to play an import role in articular cartilage in tensile testing, while fluid pressurization dominates the transient mechanical behavior in compression. Collagen viscoelasticity plays a minor role in the mechanical response of cartilage in unconfined compression if significant fluid flow is present.  相似文献   

8.
The mechanical behavior of soft tissue demonstrates a number of complex features including nonlinearity, anisotropy, viscoelasticity, and growth. Characteristic features of the time-dependent and anisotropic behavior are related to the properties of various components of the tissue such as fibrous collagen and elastin networks, large proteins and sugars attached to these networks, and interstitial fluid. Attempts to model the elastic behavior of these tissues based on assumptions about the behavior of the underlying constituents have been reasonably successful, but the essential addition of viscoelasticity to these models has been met with varying success. Here, a new rheological network model is proposed using, as its basis, an orthotropic hyperelastic constitutive model for fibrous tissue and a viscoelastic reptation model for soft materials. The resulting model has been incorporated into numerical and computational models, and is shown to capture the mechanical behavior of soft tissue in various modes of deformation including uniaxial and biaxial tension and simple shear.  相似文献   

9.
A nonlinear viscoelastic finite element model of ultra-high molecular weight polyethylene (UHMWPE) was developed in this study. Eight cylindrical specimens were machined from ram extruded UHMWPE bar stock (GUR 1020) and tested under constant compression at 7% strain for 100 sec. The stress strain data during the initial ramp up to 7% strain was utilized to model the "instantaneous" stress-strain response using a Mooney-Rivlin material model. The viscoelastic behavior was modeled using the time-dependent relaxation in stress seen after the initial maximum stress was achieved using a stored energy formulation. A cylindrical model of similar dimensions was created using a finite element analysis software program. The cylinder was made up of hexahedral elements, which were given the material properties utilizing the "instantaneous" stress-strain curve and the energy-relaxation curve obtained from the experimental data. The cylinder was compressed between two flat rigid bodies that simulated the fixtures of the testing machine. Experimental stress-relaxation, creep and dynamic testing data were then used to validate the model. The mean error for predicted versus experimental data for stress relaxation at different strain levels was 4.2%. The mean error for the creep test was 7% and for dynamic test was 5.4%. Finally, dynamic loading in a hip arthroplasty was modeled and validated experimentally with an error of 8%. This study establishes a working finite element material model of UHMWPE that can be utilized to simulate a variety of postoperative arthroplasty conditions.  相似文献   

10.
The mechanical behavior of blood vessels is known to be viscoelastic rather than elastic. The functional role of viscoelasticity, however, has remained largely unclear. The hypothesis of this study is that viscoelasticity reduces the stresses and strains in the vessel wall, which may have a significant impact on the fatigue life of the blood vessel wall. To verify the hypothesis, the pulsatile stress in rabbit thoracic artery at physiological loading condition was investigated with a quasi-linear viscoelastic model, where the normalized stress relaxation function is assumed to be isotropic, while the stress-strain relationship is anisotropic and nonlinear. The artery was subjected to the same boundary condition, and the mechanical equilibrium equation was solved for both the viscoelastic and an elastic (which has a constant relaxation function) model. Numerical results show that, compared with purely elastic response, the viscoelastic property of arteries reduces the magnitudes and temporal variations of circumferential stress and strain. The radial wall movement is also reduced due to viscoelasticity. These findings imply that viscoelasticity may be beneficial for the fatigue life of blood vessels, which undergo millions of cyclic mechanical loadings each year of life.  相似文献   

11.
The present study defines several conditions under which stress relaxation tests can be performed and investigates the viscoelastic behaviour of trabecular bone in compression through a series of stress relaxation tests at three strain levels and in three loading directions of each cubic specimen. A visoelastic model is proposed to characterize the behaviour of trabecular bone and a spectrum of relaxation times is determined. Trabecular bone from the femoral head is non-linearly viscoelastic and displays anisotropic behaviour, which cannot be more symmetric elastically than orthotropic.  相似文献   

12.
The swelling and viscoelastic behaviors of samples of purified arterial elastin were investigated to develop a model for studying the viscoelastic behavior of elastin. Two osmotic stress models were used: the vapor phase model (VPM), in which the stress on the elastin sample was applied through the vapor phase by equilibrating the sample over a saline solution, and the liquid phase model (LPM), in which the stress was applied through the liquid phase by equilibrating the sample in aqueous solutions of large molecular weight polymers. The elastin in the VPM showed a highly varied viscoelastic response, and was slightly stiffer and had a slightly higher damping coefficient than the elastin in the LPM at equivalent nominal relative humidities. We believe the difference in behavior of the elastin in the two models was due to geometric distortions of the elastin that occur during dehydration in the VPM. In the LPM, the spaces between the elastin fibrils are filled with water, and in the VPM these spaces collapse when the water is removed. Removal of only the interfibrillar water deswelled the tissue and increased its stiffness and damping coefficient. Viscoelastic spectra obtained at different levels of osmotic stress in the LPM were reducible to one master curve, indicating that the dominant effect of dehydration is a nonspecific reduction of molecular mobility. We conclude that the LPM is a better model than the VPM for studying the effects of dehydration on the mechanical behavior of elastin. © 1996 John Wiley & Sons, Inc.  相似文献   

13.
The material properties of passive skeletal muscle are critical to proper function and are frequently a target for therapeutic and interventional strategies. Investigations into the passive viscoelasticity of muscle have primarily focused on characterizing the elastic behavior, largely neglecting the viscous component. However, viscosity is a sizeable contributor to muscle stress and extensibility during passive stretch and thus there is a need for characterization of the viscous as well as the elastic components of muscle viscoelasticity. Single mouse muscle fibers were subjected to incremental stress relaxation tests to characterize the dependence of passive muscle stress on time, strain and strain rate. A model was then developed to describe fiber viscoelasticity incorporating the observed nonlinearities. The results of this model were compared with two commonly used linear viscoelastic models in their ability to represent fiber stress relaxation and strain rate sensitivity. The viscous component of mouse muscle fiber stress was not linear as is typically assumed, but rather a more complex function of time, strain and strain rate. The model developed here, which incorporates these nonlinearities, was better able to represent the stress relaxation behavior of fibers under the conditions tested than commonly used models with linear viscosity. It presents a new tool to investigate the changes in muscle viscous stresses with age, injury and disuse.  相似文献   

14.
The goal of this study was to determine the duration of time that ligaments from a study group need to be loaded in order to adequately determine their collective viscoelastic behavior. Rat ligaments were subjected either to creep or stress relaxation for 1,000 s or stress relaxation for 10,000 s to compare estimates of viscoelastic behavior for different test durations. Stresses versus time (relaxation) or strains versus time (creep) were fit with power law models (tbeta where beta is the rate of creep or relaxation on a log-log scale). Time intervals were separated by logarithmic decade and analyzed using a Random Coefficients approach to compute residual specimen error as a function of the number of decades of data analyzed. Standard Regression was also used for comparison. Results show that by testing for 相似文献   

15.
On modelling nonlinear viscoelastic effects in ligaments   总被引:2,自引:0,他引:2  
  相似文献   

16.
We previously reported that when the stress relaxation response of urinary bladder wall (UBW) tissue was analyzed using a single continuous reduced relaxation function (RRF), we observed non-uniformly distributed, time-dependent residuals (Ann Biomed Eng 32(10):1409-1419, 2004). We concluded that the single relaxation spectrum was inadequate and that a new viscoelastic model for bladder wall was necessary. In the present study, we report a new approach composed of independent RRFs for smooth muscle and the extracellular matrix components (ECM), connected through a stress-dependent recruitment function. In order to determine the RRF for the ECM component, biaxial stress relaxation experiments were first performed on decellularized extracellular matrix network of the bladder obtained from normal and spinal cord injured rats. While it was assumed that smooth muscle followed a single spectrum RRF, modeling the UBW ECM required a dual-Gaussian spectrum. Experimental results revealed that the ECM stress relaxation response was insensitive to the initial stress level. Thus, the average ECM RRF parameters were determined by fitting the average stress relaxation data. The resulting stress relaxation behavior of whole bladder tissue was modeled by combining the ECM RRF with the RRF for the smooth muscle component using an exponential recruitment function representing the recruitment of collagen fibers at higher stress levels. In summary, the present study demonstrated, for the first time, that stress relaxation response of bladder tissue can be better modeled when divided into the contributions of the extracellular matrix and smooth muscle components. This modeling approach is suitable for prediction of mechanical behaviors of the urinary bladder and other organs that exhibit rapid tissue remodeling (i.e., smooth muscle hypertrophy and altered ECM synthesis) under various pathological conditions.  相似文献   

17.
We have recently demonstrated that the mitral valve anterior leaflet (MVAL) exhibited minimal hysteresis, no strain rate sensitivity, stress relaxation but not creep (Grashow et al., 2006, Ann Biomed Eng., 34(2), pp. 315-325; Grashow et al., 2006, Ann Biomed. Eng., 34(10), pp. 1509-1518). However, the underlying structural basis for this unique quasi-elastic mechanical behavior is presently unknown. As collagen is the major structural component of the MVAL, we investigated the relation between collagen fibril kinematics (rotation and stretch) and tissue-level mechanical properties in the MVAL under biaxial loading using small angle X-ray scattering. A novel device was developed and utilized to perform simultaneous measurements of tissue level forces and strain under a planar biaxial loading state. Collagen fibril D-period strain (epsilonD) and the fibrillar angular distribution were measured under equibiaxial tension, creep, and stress relaxation to a peak tension of 90 N/m. Results indicated that, under equibiaxial tension, collagen fibril straining did not initiate until the end of the nonlinear region of the tissue-level stress-strain curve. At higher tissue tension levels, epsilonD increased linearly with increasing tension. Changes in the angular distribution of the collagen fibrils mainly occurred in the tissue toe region. Using epsilonD, the tangent modulus of collagen fibrils was estimated to be 95.5+/-25.5 MPa, which was approximately 27 times higher than the tissue tensile tangent modulus of 3.58+/-1.83 MPa. In creep tests performed at 90 N/m equibiaxial tension for 60 min, both tissue strain and epsilonD remained constant with no observable changes over the test length. In contrast, in stress relaxation tests performed for 90 min epsilonD was found to rapidly decrease in the first 10 min followed by a slower decay rate for the remainder of the test. Using a single exponential model, the time constant for the reduction in collagen fibril strain was 8.3 min, which was smaller than the tissue-level stress relaxation time constants of 22.0 and 16.9 min in the circumferential and radial directions, respectively. Moreover, there was no change in the fibril angular distribution under both creep and stress relaxation over the test period. Our results suggest that (1) the MVAL collagen fibrils do not exhibit intrinsic viscoelastic behavior, (2) tissue relaxation results from the removal of stress from the fibrils, possibly by a slipping mechanism modulated by noncollagenous components (e.g. proteoglycans), and (3) the lack of creep but the occurrence of stress relaxation suggests a "load-locking" behavior under maintained loading conditions. These unique mechanical characteristics are likely necessary for normal valvular function.  相似文献   

18.
This paper presents a constitutive model for predicting the nonlinear viscoelastic behavior of soft biological tissues and in particular of ligaments. The constitutive law is a generalization of the well-known quasi-linear viscoelastic theory (QLV) in which the elastic response of the tissue and the time-dependent properties are independently modeled and combined into a convolution time integral. The elastic behavior, based on the definition of anisotropic strain energy function, is extended to the time-dependent regime by means of a suitably developed time discretization scheme. The time-dependent constitutive law is based on the postulate that a constituent-based relaxation behavior may be defined through two different stress relaxation functions: one for the isotropic matrix and one for the reinforcing (collagen) fibers. The constitutive parameters of the viscoelastic model have been estimated by curve fitting the stress relaxation experiments conducted on medial collateral ligaments (MCLs) taken from the literature, whereas the predictive capability of the model was assessed by simulating experimental tests different from those used for the parameter estimation. In particular, creep tests at different maximum stresses have been successfully simulated. The proposed nonlinear viscoelastic model is able to predict the time-dependent response of ligaments described in experimental works (Bonifasi-Lista et al., 2005, J. Orthopaed. Res., 23, pp. 67-76; Hingorani et al., 2004, Ann. Biomed. Eng., 32, pp. 306-312; Provenzano et al., 2001, Ann. Biomed. Eng., 29, pp. 908-214; Weiss et al., 2002, J. Biomech., 35, pp. 943-950). In particular, the nonlinear viscoelastic response which implies different relaxation rates for different applied strains, as well as different creep rates for different applied stresses and direction-dependent relaxation behavior, can be described.  相似文献   

19.
The viscoelastic properties of porcine carotid tissue are investigated in this work. Experimental uniaxial stress relaxation tests along the longitudinal and circumferential directions of the vessel were performed for carotid strips extracted from 10 vessels. Directional and local differences - distal versus proximal position - in the tissue behavior were investigated. The experimental tests reveal a highly anisotropic, non-linear viscoelastic response and local dependence of the samples. The carotid artery shows anisotropic relaxation behavior for both proximal and distal samples. The highest stress relaxation was found in the circumferential tensile test for the highest applied strain at the distal position. For the circumferential direction, the relaxation stress was higher than in the longitudinal being at its highest in the distal position. These facts show that the stress relaxation is higher in the distal than in the proximal position. However, there are no differences between both positions in the longitudinal direction. In addition, a constitutive law that takes into account the fundamental features, including non-linear viscoelasticity, of the arterial tissue is proposed. The present results are correlated with the purely elastic response and the microstructural analysis of the tissue by means of histological quantification presented in a previous study.  相似文献   