首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel strategy to fabricate an amperometric biosensor for phenol determination based on chitosan/laponite nanocomposite matrix was described. The composite film was used to immobilize PPO on the surface of a glassy carbon electrode. Chitosan was utilized to improve the analytical performance of the pure clay-modified bioelectrode. The biosensor exhibited a series of properties: good affinity to its substrate (the apparent Michaelis-Menten constant for the sensor was found to be 0.16 mM), high sensitivity (674 mA M(-1)cm(-2) for catechol) and remarkable long-term stability in storage (it retains 88% of the original activity after 60 days). In addition, optimization of the biosensor construction as well as effects of experimental variables such as pH, operating potential and temperature on the amperometric response of the sensor were discussed.  相似文献   

2.
Modified screen-printed electrodes for amperometric detection of H(2)O(2) and nicotinamide adenine dinucleotide (NADH) at low applied potential are presented in this paper. The sensors are obtained by modifying the working electrode surface with Prussian Blue, a well known electrochemical mediator for H(2)O(2) reduction. The coupling of this sensor with phenazine methosulfate (PMS) in the working solution gives the possibility of measuring both NAD(P)H and H(2)O(2). PMS reacts with NADH producing PMSH, which in the presence of oxygen, gives an equimolar amount of H(2)O(2). This allows the measurement of both analytes with similar sensitivity (357 mA mol(-1)L cm(-2) for H(2)O(2) and 336 mA mol(-1)L cm(-2) for NADH) and LOD (5x10(-7)mol L(-1) for H(2)O(2) and NADH) and opens the possibility of a whole series of biosensor applications. In this paper, results obtained with a variety of dehydrogenase enzymes (alcohol, malic, lactate, glucose, glycerol and glutamate) for the detection of enzymatic substrates or enzymatic activity are presented demonstrating the suitability of the proposed method for future biosensor applications.  相似文献   

3.
A new amperometric biosensor, based on adsorption of glucose oxidase (GOD) at the platinum nanoparticle-modified carbon nanotube (CNT) electrode, is presented in this article. CNTs were grown directly on the graphite substrate. The resulting GOD/Pt/CNT electrode was covered by a thin layer of Nafion to avoid the loss of GOD in determination and to improve the anti-interferent ability. The morphologies and electrochemical performance of the CNT, Pt/CNT, and Nafion/GOD/Pt/CNT electrodes have been investigated by scanning electron microscopy, cyclic voltammetry, and amperometric methods. The excellent electrocatalytic activity and special three-dimensional structure of the enzyme electrode result in good characteristics such as a large determination range (0.1-13.5mM), a short response time (within 5s), a large current density (1.176 mA cm(-2)), and high sensitivity (91mA M(-1)cm(-2)) and stability (73.5% remains after 22 days). In addition, effects of pH value, applied potential, electrode construction, and electroactive interferents on the amperometric response of the sensor were investigated and discussed. The reproducibility and applicability to whole blood analysis of the enzyme electrode were also evaluated.  相似文献   

4.
Han E  Shan D  Xue H  Cosnier S 《Biomacromolecules》2007,8(3):971-975
A new type of amperometric phenol biosensor based on chitosan/layered double hydroxides organic-inorganic composite film was described. This hybrid material combined the advantages of organic biopolymer, chitosan, and inorganic layered double hydroxides. Polyphenol oxidase (PPO) immobilized in the material maintained its activity well as the usage of glutaraldehyde was avoided. The composite films have been characterized by Fourier transform infrared. The results indicated that PPO retained the essential feature of its native structure in the composite film. The enzyme electrode provided a linear response to catechol over a concentration range of 3.6 x 10(-9) to 4 x 10(-5) M with a sensitivity of 2750 +/- 52 mA M(-1) cm(-2) and a detection limit of 0.36 nM based on S/N = 3. The apparent Michaelis-Menten constant K(app)(M) for the sensor was found to be 0.13 mM. The activation energy for enzymatic reaction was calculated to be 27.6 kJ mol(-1). Furthermore, the biosensor exhibited excellent long-term stability and satisfactory reproducibility.  相似文献   

5.
A novel amperometric biosensor, based on electrodeposition of platinum nanoparticles onto multi-walled carbon nanotube (MWNTs) and immobilizing enzyme with chitosan-SiO(2) sol-gel, is presented in this article. MWNTs were cast on the glass carbon (GC) substrate directly. An extra Nafion coating was used to eliminate common interferents such as acetaminophen and ascorbic acids. The morphologies and electrochemical performance of the modified electrodes have been investigated by scanning electron microscopy (SEM) and amperometric methods, respectively. The synergistic action of Pt and MWNTs and the biocompatibility of chitosan-SiO(2) sol-gel made the biosensor have excellent electrocatalytic activity and high stability. The resulting biosensor exhibits good response performance to glucose with a wide linear range from 1 microM to 23 mM and a low detection limit 1 microM. The biosensor also shows a short response time (within 5s), and a high sensitivity (58.9 microAm M(-1)cm(-2)). In addition, effects of pH value, applied potential, rotating rate, electrode construction and electroactive interferents on the amperometric response of the sensor were investigated and discussed in detail.  相似文献   

6.
Pan D  Chen J  Nie L  Tao W  Yao S 《Analytical biochemistry》2004,324(1):115-122
Prussian blue (PB), as a good catalyst for the reduction of hydrogen peroxide, has been combined with nonconducting poly(o-aminophenol) (POAP) film to assemble glucose biosensor. Compared with PB-modified enzymatic biosensor, the biosensor based on glucose oxidase immobilized in POAP film at PB-modified electrode shows much improved stability (78% remains after 30 days) in neutral medium. Additionally, the biosensor, at an applied potential of 0.0 V, exhibits other good characteristics, such as relative low detection limit (0.01 mM), short response time (within 5s), large current density (0.28 mA/cm2), high sensitivity (24 mAM(-1)cm(-2)), and good antiinterferent ability. The apparent activation energy of enzyme-catalyzed reaction and apparent Michaelis-Menten constant are 34.2 KJmol(-1) and 10.5 mM, respectively. In addition, effects of temperature, applied potential used in the determination, pH value of the detection solution, and electroactive interferents on the amperometric response of the sensor were investigated and are discussed.  相似文献   

7.
A bienzymatic glucose biosensor was proposed for selective and sensitive detection of glucose. This mediatorless biosensor was made by simultaneous immobilization of glucose oxidase (GOD) and horseradish peroxidase (HRP) in an electropolymerized pyrrole (PPy) film on a single-wall carbon nanotubes (SWNT) coated electrode. The amperometric detection of glucose was assayed by potentiostating the bienzymatic electrode at -0.1 versus Ag/AgCl to reduce the enzymatically produced H(2)O(2) with minimal interference from the coexisting electroactive compounds. The single-wall carbon nanotubes, sandwiched between the enzyme loading polypyrrole (PPy) layer and the conducting substrate (gold electrode), could efficiently promote the direct electron transfer of HRP. Operational characteristics of the bienzymatic sensor, in terms of linear range, detection limit, sensitivity, selectivity and stability, were presented in detail.  相似文献   

8.
As the purines, in particular adenosine, are important signaling agents in the nervous system we have devised a new biosensor for directly measuring their production in real time during physiological activity. Our amperometric adenosine biosensor is made by entrapping 3 enzymes (xanthine oxidase, purine nucleoside phosphorylase and adenosine deaminase) in a composite lactobionamide and amphiphillic polypyrrole matrix around a Pt microelectrode. The resulting sensors are small (25-100 microm diameter), fast responding (10-90% rise time, 2+/-0.23 s), sensitive (100-222 mA M(-1) cm(-2)) and stable (100% activity after 5 days). The sensor was used in vivo to demonstrate the spatial localization of release of adenosine from Xenopus embryo spinal cord during fictive swimming.  相似文献   

9.
In the present work, an amperometric inhibition biosensor for the determination of sulfide has been fabricated by immobilizing Coprinus cinereus peroxidase (CIP) on the surface of screen printed electrode (SPE). Chitosan/acrylamide was applied for immobilization of peroxidase on the working electrode. The amperometric measurement was performed at an applied potential of -150 mV versus Ag/AgCl with a scan rate of 100 mV in the presence of hydroquinone as electron mediator and 0.1M phosphate buffer solution of pH 6.5. The variables influencing the performance of sensor including the amount of substrate, mediator concentration and electrolyte pH were optimized. The determination of sulfide can be achieved in a linear range of 1.09-16.3 μM with a detection limit of 0.3 μM. Developed sensor showed quicker response to sulfide compared to the previous developed sulfide biosensors. Common anions and cations in environmental water did not interfere with sulfide detection by the developed biosensor. Cyanide interference on the enzyme inhibition caused 43.25% error in the calibration assay which is less than the amounts reported by previous studies. Because of high sensitivity and the low-cost of SPE, this inhibition biosensor can be successfully used for analysis of environmental water samples.  相似文献   

10.
A sensitive glutamate biosensor is prepared based on glutamate dehydrogenase/vertically aligned carbon nanotubes (GLDH, VACNTs). Vertically aligned carbon nanotubes were grown on a silicon substrate by direct current plasma enhanced chemical vapor deposition (DC-PECVD) method. The electrochemical behavior of the synthesized VACNTs was investigated by cyclic voltammetry and electrochemical impedance spectroscopic methods. Glutamate dehydrogenase covalently attached on tip of VACNTs. The electrochemical performance of the electrode for detection of glutamate was investigated by cyclic and differential pulse voltammetry. Differential pulse voltammetric determinations of glutamate are performed in mediator-less condition and also, in the presence of 1 and 5 μM thionine as electron mediator. The linear calibration curve of the concentration of glutamate versus peak current is investigated in a wide range of 0.1-500 μM. The mediator-less biosensor has a low detection limit of 57 nM and two linear ranges of 0.1-20 μM with a sensitivity of 0.976 mA mM(-1) cm(-2) and 20-300 μM with a sensitivity of 0.182 mA mM(-1) cm(-2). In the presence of 1 μM thionine as an electron mediator, the prepared biosensor shows a low detection limit of 68 nM and two linear ranges of 0.1-20 with a calibration sensitivity of 1.17 mA mM(-1) cm(-2) and 20-500 μM with a sensitivity of 0.153 mA mM(-1) cm(-2). The effects of the other biological compounds on the voltammetric behavior of the prepared biosensor and its response stability are investigated. The results are demonstrated that the GLDH/VACNTs electrode even without electron mediator is a suitable basic electrode for detection of glutamate.  相似文献   

11.
Borate buffer strongly decreases amperometric response of a glucose oxidase linked pO2 or H2O2 sensing electrode, extending substantially its linear calibration range. With increasing pH and concentration of the buffer the upper limit for glucose can be varied between 1 and 30 mmol l-1 glucose. The effect of borate ion is explained by the rapid complexation of glucose decreasing the equilibrium concentration of free beta-anomer, the specific substrate of glucose oxidase. The high loading of cross-linked enzyme inside the sensor membrane is necessary for the measurement to ensure an almost constant response factor (delta i per 1 mmol l-1) between pH 5 and 10. Analysis in stirred solution and in a flow-through system has been employed for the measurement of elevated glucose levels in heparinized human blood or plasma samples.  相似文献   

12.
A novel inexpensive and simple amperometric biosensor, based on the immobilization of HRP into redox active [Zn-Cr-ABTS] layered double hydroxide, is applied to the determination of cyanide. The electrochemical transduction step corresponds to the reduction at 0.0 V of ABTS+* enzymatically formed in the presence of H2O2. The biosensor has a fast response to H2O2 (8s) with a linear range of 1.7 x 10(-9) to 2.1 x 10(-6) M and a sensitivity of 875 mA M(-1) cm(-2). The apparent Michaelis-Menten constant (KMapp) is 12 microM. The detection of cyanide is performed via its non competitive inhibiting action on the HRP/[Zn-Cr-ABTS] electrode. The concentration range of the linear response and the apparent inhibition constant (ki) are 5 x 10(-9) to 4 x 10(-8) and 1.4 x 10 (-7) M, respectively.  相似文献   

13.
This paper describes a new amperometric biosensor for glucose monitoring. The biosensor is based on the activity of glucose dehydrogenase (GDH) and diaphorase (DI) co-immobilized with NAD(+) into a carbon nanotube paste (CNTP) electrode modified with an osmium functionalized polymer. This mediator was demonstrated to shuttle the electron transfer between the immobilized diaphorase and the CNTP electrode, thus, showing a good electrocatalytic activity towards NADH oxidation at potentials around +0.2V versus Ag|AgCl, where interfering reactions are less prone to occur. The biosensor exhibits a detection limit of 10 micromol L(-1), linearity up to 8 x 10(-4) mol L(-1), a sensitivity of 13.4 microA cm(-2)mmol(-1)L(-1), a good reproducibility (R.S.D. 2.1%, n=6) and a stability of about 1 week when stored dry at 4 degrees C. Finally, the proposed biosensor was applied for the determination of glucose in different samples of sweet wine and validated with a commercial spectrophotometric enzymatic kit.  相似文献   

14.
An amperometric principle based biosensor containing tissues of cucumber, rich in ascorbic acid oxidase, was used for the detection of organophosphorous (OP) pesticide ethyl paraoxon, which inhibits the activity of ascorbic acid oxidase. The optimal concentration of ascorbic acid used as substrate was found to be 5.67 mM. The biosensor response was found to reach steady state within 2 min. A measurable inhibition (> 10%) was obtained with 10 min incubation of the enzyme electrode with different concentrations of the pesticide. There was a linear relationship between the percentage of inhibition of the enzyme substrate reaction and the pesticide (ethyl paraoxon) concentration in the range 1-10 ppm with a regression value 0.9942.  相似文献   

15.
Hydroquinone diphosphate (HQDP) was synthesized and compared to phenyl phosphate (PP) and 1-naphthyl phosphate (NP) as a substrate for alkaline phosphatase (AP) under electrochemical immunoassay (EIA) conditions. Voltammetric and amperometric experiments showed that electrochemical oxidation of hydroquinone (HQ), which is the AP hydrolysis product of HQDP, did not produce electrode passivation, even with repeated biosensor use. In contrast, phenol and 1-naphthol, the hydrolysis products of PP and NP, respectively, were shown to be irreversibly oxidized on the electrode surfaces, and produced rapid electrode passivation, resulting in complete loss of electrode signal. When employed as AP substrate in an iridium oxide based EIA, HQDP produced significantly larger amperometric responses (117 microA/cm2) compared to PP (31 microA/cm2) and NP (27 microA/cm2). The results presented in this paper show that HQDP is an attractive alternative to commonly used AP substrates such as NP and PP. The substrate shows excellent hydrolytic stability, produces larger amperometric responses (than PP or NP), and does not produce sensor passivation.  相似文献   

16.
An amperometric biosensor for the detection of cellobiose has been introduced to study the kinetics of enzymatic hydrolysis of crystalline cellulose by cellobiohydrolase. By use of a sensor in which pyrroloquinoline quinone-dependent glucose dehydrogenase was immobilized on the surface of electrode, direct and continuous observation of the hydrolysis can be achieved even in a thick cellulose suspension. The steady-state rate of the hydrolysis increased with increasing concentrations of the enzyme to approach a saturation value and was proportional to the amount of the substrate. The experimental results can be explained well by the rate equations derived from a three-step mechanism consisting of the adsorption of the free enzyme onto the surface of the substrate, the reaction of the adsorbed enzyme with the substrate, and the liberation of the product. The catalytic constant of the adsorbed enzyme was determined to be 0.044+/-0.011s(-1).  相似文献   

17.
An amperometric microbial biosensor for the direct measurement of organophosphate nerve agents is described. The sensor is based on a carbon paste electrode containing genetically engineered cells expressing organophosphorus hydrolase (OPH) on the cell surface. OPH catalyzes the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon, parathion and methyl parathion to p-nitrophenol. The later is detected anodically at the carbon transducer with the oxidation current being proportional to the nerve-agent concentration. The sensor sensitivity was optimized with respect to the buffer pH and loading of cells immobilized using paraoxon as substrate. The best sensitivity was obtained using a sensor constructed with 10 mg of wet cell weight per 100 mg of carbon paste and operating in pH 8.5 buffer. Using these conditions, the biosensor was used to measure as low as 0.2 microM paraoxon and 1 microM methyl parathion with very good sensitivity, excellent selectivity and reproducibility. The microbial biosensor had excellent storage stability, retaining 100% of its original activity when stored at 4 degrees C for up to 45 days.  相似文献   

18.
A novel polyaniline-ionic liquid-carbon nanofiber (PANI-IL-CNF) composite was greenly prepared by in situ one-step electropolymerization of aniline in the presence of IL and CNF for fabrication of amperometric biosensors. The scanning electron micrographs confirmed that the PANI uniformly grew along with the structure of CNF and the PANI-IL-CNF composite film showed a fibrillar morphology with the diameter of around 95 nm. A phenol biosensor was constructed by immobilizing tyrosinase on the surface of the composite modified glassy carbon electrode via the cross-linking step with glutaraldehyde. The biosensor exhibited a wide linear response to catechol ranging from 4.0 x 10(-10) to 2.1 x 10(-6)M with a high sensitivity of 296+/-4 AM(-1)cm(-2), a limit of detection down to 0.1 nM at the signal to noise ratio of 3 and applied potential of -0.05 V. According to the Arrhenius equation, the activation energy for enzymatic reaction was calculated to be 38.8 kJmol(-1) using catechol as the substrate. The apparent Michaelis-Menten constants of the enzyme electrode were estimated to be 1.44, 1.33, 1.16, 0.65 microM for catechol, p-cresol, phenol, m-cresol, respectively. The functionalization of CNF with PANI in IL provided good biocompatible platform for biosensing and biocatalysis.  相似文献   

19.
Pyrrole was electropolymerized onto a Pt electrode in the presence of LiClO(4) and horseradish peroxidase (HRP). This HRP-based biosensor has been used for the amperometric detection of rifampicin (RIF) in the presence of a constant concentration of H(2)O(2). The C(H(2)O(2)) as well as the applied potential (E(ap)) and the pH of the phosphate buffer have simultaneously been optimized through a central composite design. Under these conditions, repeatability, reproducibility, and stability of the modified electrode have been analyzed. The detection limit for RIF has been calculated taking into account the probability of false-positive (alpha) and -negative (beta), reaching a value of 5.06x10(-6) mol dm(-3). The biosensor was applied to the determination of RIF in pharmaceutical preparations and biological samples.  相似文献   

20.
An amperometric biosensor was constructed for analysis of human salivary phosphate without sample pretreatment. The biosensor was constructed by immobilizing pyruvate oxidase (PyOD) on a screen-printed electrode. The presence of phosphate in the sample causes the enzymatic generation of hydrogen peroxide (H(2)O(2)), which was monitored by a potentiostat and was in proportion to the concentration of human salivary phosphate. The sensor shows response within 2s after the addition of standard solution or sample and has a short recovery time (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 to 625 microM phosphate with a detection limit of 3.6 microM. A total of 50 salivary samples were collected for the determination of phosphate. A good level of agreement (R(2)=0.9646) was found between a commercial phosphate testing kit and the phosphate sensor. This sensor maintained a high working stability (>85%) after 12h operation and required only a simple operation procedure. The amperometric biosensor using PyOD is a simple and accurate tool for rapid determinations of human salivary phosphate, and it explores the application of biosensors in oral and dental research and diagnosis.  相似文献   