首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI/TOF/MS) with delayed extraction is utilized in linear, reflected-ion and post-source decay (PSD) modes to directly characterize enzymes being developed for use in a petroleum desulfurization process. The DNA sequence for the genes isolated fromRhodococcussp. strain IGTS8 that produce three of the four enzymes under study had been previously reported with a discrepancy in residue assignments for one of the enzymes, dsz-C. The use of proteolytic digests followed by MALDI/TOF/MS with delayed extraction in the reflected-ion mode provided sequence-specific information with mass accuracies exceeding 40 ppm over a range of masses and signal-to-noise values. Peptide mapping of >80% of the residues was accomplished for all four proteins. The use of PSD established the true sequence for dsz-C, resolving the discrepancy in the literature. A posttranslational loss of N-terminal methionine was observed for each of the four proteins in linear MALDI/MS and was reconfirmed by peptide mapping for three of the proteins.  相似文献   

2.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF) was used to quantify the phosphopeptide produced by calcium/calmodulin-dependent protein kinase II (CaMK II). MALDI-TOF measurements were performed in a linear and positive ion mode with delayed extraction excited at various laser powers and at different sampling positions, i.e., different loci of laser illumination. We find that the ratio of the peak area of the substrate (S) to that of its monophosphorylated form (SP) for a given mixture is constant, independent of the laser powers and/or of the sample loci illuminated by the laser. We also find that the fraction of phosphorylation determined by MALDI-TOF, orfMALDI-TOF, is proportionally smaller than that determined by HPLC, orfHPLC; the ratiofMALDI-TOF/fHPLCwas 0.797 ± 0.0229 (99% confidence limit,n= 7) for a 30-mer peptide substrate used in this study. A low mass gate, which turns off the detector temporarily, improved the ratiofMALDI-TOF/fHPLCto 0.917 ± 0.0184 (99% confidence limit,n= 7). Our interpretation of this result is that the reduction of the phosphopeptide peak in the MALDI-TOF measurement is likely to be caused by a temporal loss of detector function rather than by a lower efficiency of ionization for the phosphopeptide compared with its parent species. In these measurements the experimental errors, up to the 50% phosphorylation state, were less than 5%. After an adjustment made based on thefMALDI-TOF/fHPLCratio of 0.917, MALDI-TOF gave an accurate measurement for the kinetics of the CaMK II phosphorylation reaction. Since only a small volume of the reaction mixture, typically containing 3 to 50 pmol of substrate, is required for the MALDI-TOF measurement, this method can be adapted to a nonradioactive microscale assay for CaMK II and also for other protein kinases.  相似文献   

3.
The use of peptide mass fingerprinting with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was demonstrated to identify and phenotypically characterize toluene-degrading bacteria via biomarkers of degradation and taxonomical classification. Pseudomonas putida F1, P. mendocina KR1, and Burkholderia sp. JS150 were grown on toluene, extracted, electrophoretically separated, and analyzed by MALDI-TOF MS. Catabolic enzymes were identified and results substantiated using tandem MS.  相似文献   

4.
5.
Rapid identification of microorganisms in urine is essential for patients with urinary tract infections (UTIs). Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been proposed as a method for the direct identification of urinary pathogens. Our purpose was to compare centrifugation-based MALDI-TOF MS and short-term culture combined with MALDI-TOF MS for the direct identification of pathogens in urine specimens. We collected 965 urine specimens from patients with suspected UTIs, 211/965 isolates were identified as positive by conventional urine culture. Compared with the conventional method, the results of centrifugation-based MALDI-TOF MS were consistent in 159/211 cases (75.4%), of which 135/159 (84.9%) had scores ≥ 2.00; 182/211 cases (86.3%) were detected using short-term culture combined with MALDI-TOF MS, of which 153/182 (84.1%) had scores ≥ 2.00. There were no apparent differences among the three methods (p = 0.135). MALDI-TOF MS appears to accelerate the microbial identification speed in urine and saves at least 24 to 48 hours compared with the routine urine culture. Centrifugation-based MALDI-TOF MS is characterized by faster identification speed; however, it is substantially affected by the number of bacterial colonies. In contrast, short-term culture combined with MALDI-TOF MS has a higher detection rate but a relatively slow identification speed. Combining these characteristics, the two methods may be effective and reliable alternatives to traditional urine culture.  相似文献   

6.
Matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) has been used to identify bacteria based upon protein signatures. This research shows that while some different proteins are produced by vegetative bacteria when they are cultured in different growth media, positive identification with MALDI-TOF MS is still possible with the protocol established at the Pacific Northwest National Laboratory (K. H. Jarman, S. T. Cebula, A. J. Saenz, C. E. Petersen, N. B. Valentine, M. T. Kingsley, and K. L. Wahl, Anal. Chem. 72:1217-1223, 2000). A core set of small proteins remain constant under at least four different culture media conditions and blood agar plates, including minimal medium M9, rich media, tryptic soy broth (TSB) or Luria-Bertani (LB) broth, and blood agar plates, such that analysis of the intact cells by matrix-assisted laser desorption/ionization mass spectrometry allows for consistent identification.  相似文献   

7.
Human trichinellosis occurs through consumption of raw or inadequately processed meat or meat products containing larvae of the parasitic nematodes of the genus Trichinella. Currently, nine species and three genotypes are recognized, of which T. spiralis, T. britovi and T. pseudospiralis have the highest public health relevance. To date, the differentiation of the larvae to the species and genotype level is based primarily on molecular methods, which can be relatively time consuming and labor intensive. Due to its rapidness and ease of use a matrix assisted laser desorption / ionization time of flight mass spectrometry (MALDI-TOF MS) reference spectra database using Trichinella strains of all known species and genotypes was created. A formicacid/acetonitrile protein extraction was carried out after pooling 10 larvae of each Trichinella species and genotype. Each sample was spotted 9 times using α-cyano 4-hydoxy cinnamic acid matrix and a MicroFlex LT mass spectrometer was used to acquire 3 spectra (m/z 2000 to 20000 Da) from each spot resulting in 27 spectra/species or genotype. Following the spectra quality assessment, Biotyper software was used to create a main spectra library (MSP) representing nine species and three genotypes of Trichinella. The evaluation of the spectra generated by MALDI-TOF MS revealed a classification which was comparable to the results obtained by molecular methods. Also, each Trichinella species utilized in this study was distinct and distinguishable with a high confidence level. Further, different conservation methods such as freezing and conservation in alcohol and the host species origin of the isolated larvae did not have a significant influence on the generated spectra. Therefore, the described MALDI-TOF MS can successfully be implemented for both genus and species level identification and represents a major step forward in the use of this technique in foodborne parasitology.  相似文献   

8.
Signal suppression is a problem in matrix-assisted laser desorption/ionization mass spectrometry of peptides prepared by capillary electrophoresis. Many common electrolytes that are efficient for separation, such as sodium phosphate, also are strongly suppressive during laser desorption/ionization. We have tested individual electrolytes for highest performance in each step of separation and collection, respectively. Suppression is not observed if citrate, trifluoroacetic acid, or hydrochloric acid is used for collection, while phosphate still can be employed in the capillary providing excellent resolution. Low concentrations of hydrochloric acid added to the sample/matrix mixture generate mass spectra with better ion intensities than if trifluoroacetic acid or citrate is used.  相似文献   

9.

Background

With long delays observed between sampling and availability of results, the usefulness of blood cultures in the context of emergency infectious diseases has recently been questioned. Among methods that allow quicker bacterial identification from growing colonies, matrix-assisted laser desorption ionisation time-of-flight (MALDI-TOF) mass spectrometry was demonstrated to accurately identify bacteria routinely isolated in a clinical biology laboratory. In order to speed up the identification process, in the present work we attempted bacterial identification directly from blood culture bottles detected positive by the automate.

Methodology/Principal Findings

We prospectively analysed routine MALDI-TOF identification of bacteria detected in blood culture by two different protocols involving successive centrifugations and then lysis by trifluoroacetic acid or formic acid. Of the 562 blood culture broths detected as positive by the automate and containing one bacterial species, 370 (66%) were correctly identified. Changing the protocol from trifluoroacetic acid to formic acid improved identification of Staphylococci, and overall correct identification increased from 59% to 76%. Lack of identification was observed mostly with viridans streptococci, and only one false positive was observed. In the 22 positive blood culture broths that contained two or more different species, only one of the species was identified in 18 samples, no species were identified in two samples and false species identifications were obtained in two cases. The positive predictive value of bacterial identification using this procedure was 99.2%.

Conclusions/Significance

MALDI-TOF MS is an efficient method for direct routine identification of bacterial isolates in blood culture, with the exception of polymicrobial samples and viridans streptococci. It may replace routine identification performed on colonies, provided improvement for the specificity of blood culture broths growing viridans streptococci is obtained in the near future.  相似文献   

10.

Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) is widely used in clinical laboratories for routine identification of bacteria and yeasts. However, methodological difficulties are still apparent when applied to filamentous fungi. The liquid cultivation method recommended by Bruker Daltonics GmbH for identification of filamentous fungi by MALDI-TOF MS is labour intensive and time-consuming. In this study, growth of Aspergillus species on different (porous) surfaces was investigated with the aim to develop a more reliable, quicker and less laborious identification method using MALDI-TOF MS. Mycelial growth without sporulation mimicking liquid cultivation and reliable MALDI-TOF MS spectra were obtained when A. fumigatus strains were grown on and in between a polycarbonate membrane filter on Sabouraud dextrose agar. A database of in-house reference spectra was created by growing Aspergillus reference strains (mainly focusing on sections Fumigati and Flavi) under these selected conditions. A test set of 50 molecularly identified strains grown under different conditions was used to select the best growth condition for identification and to perform an initial validation of the in-house database. Based on these results, the cultivation method on top of a polycarbonate filter proved to be most successful for species identification. This method was therefore selected for the identification of two sets of clinical isolates that mainly consisted of Aspergilli (100 strains originating from Indonesia, 70 isolates from Qatar). The results showed that this cultivation method is reliable for identification of clinically relevant Aspergillus species, with 67% and 76% correct identification of strains from Indonesia and Qatar, respectively. In conclusion, cultivation of Aspergilli on top of a polycarbonate filter showed improved results compared to the liquid cultivation protocol recommended by Bruker in terms of percentage of correct identification, ease of MSP creation, time consumption, cost and labour intensity. This method can be reliably applied for identification of clinically important Aspergilli and has potential for identification of other filamentous fungi.

  相似文献   

11.
Identification of mineral-associated biosignatures is of significance for retrieving biochemical information from geological records here on Earth and for detecting signs of life on other planets, such as Mars. An investigation using laser desorption Fourier transform mass spectrometry was conducted to determine whether geomatrix-assisted laser desorption/ionization (GALDI) can be used to detect amino acids (e.g., histidine, threonine, and cysteine) and small proteins (e.g., gramicidin S) associated with mineral phases and whether the geomatrix impacts detection. Iron oxide (Fe2 O 3 ) and sodium chloride (NaCl) were investigated as clean chemical analogues of hematite and halite, respectively, which have both been detected on the surface of Mars. Samples were prepared by 2 methods: (1) application of analyte solution to the geomatrix surface with subsequent drying; and (2) physical mixing of analyte and geomatrix. Amino acids incorporated within NaCl by physical mixing yielded a better signal-to-noise ratio than those that were applied to the surface of a NaCl pellet. The composition of the geomatrix had an influence on the detection of biomolecules. Peaks corresponding to the cation-attached biomolecular ions were observed for the NaCl prepared samples. However, no biomolecular ion species were observed in samples using Fe 2 O 3 as geomatrix. Instead, only minor peaks that may correspond to ions derived from fragments of the biomolecules were obtained.  相似文献   

12.
Atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry (AP-MALDI MS) was applied to develop a proteomics-based method to detect and identify Neisseria species. Heat-inactivated clinical isolate cell suspensions of Neisseria gonorrhoeae and strains belonging to five serogroups (A, B, C, W135, and Y) of Neisseria meningitidis were subjected to on-probe protein/peptide extraction and tryptic digestion followed by AP-MALDI tandem MS (MS/MS)-based proteomic analysis. Amino acid sequences derived from three protonated peptides with m/z values of 1743.8, 1894.8, and 1946.8 were identified by AP-MALDI MS/MS and MASCOT proteome database search analysis as belonging to neisserial acyl carrier protein, neisserial-conserved hypothetical protein, and neisserial putative DNA binding protein, respectively. These three peptide masses can thus be potential biomarkers for neisserial species identification by AP-MALDI MS.  相似文献   

13.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been widely used for structural characterization of bacterial endotoxins (lipid A). However, the mass spectrometric behavior of the lipid A molecule is highly dependent on the matrix. Furthermore, this dependence is strongly linked to phosphorylation patterns. Using lipid A from Escherichia coli O116 as a model system, we have investigated the effects of different matrices and comatrix compounds on the analysis of lipid A. In this paper, we report a highly sensitive matrix system for lipid A analysis, which consists of 5-chloro-2-mercaptobenzothiazole matrix and EDTA ammonium salt comatrix. This matrix system enhances the sensitivity of the analysis of diphosphorylated lipid A species by more than 100-fold and in addition provides tolerance to high concentrations of sodium dodecyl sulfate (SDS) and tolerance to sodium chloride and calcium chloride at 10 μM, 100 μM, and 10 μM concentrations. The method was further evaluated for analysis of lipid A species with different phosphorylation patterns and from different bacteria, including Helicobacter pylori, Salmonella enterica serovar Riogrande, and Francisella novicida.Lipopolysaccharide (LPS) is a major component of the outer membranes of Gram-negative bacteria (21). Typically, LPS molecules consist of a hydrophilic carbohydrate portion and a hydrophobic lipid A (or endotoxin). The lipid A molecule consists of a fatty acyl substituted β-d-GlcN-(1-6)-α-GlcN disaccharide unit that usually carries phosphate groups. Diphosphorylated lipid A is generally presumed to be phosphorylated at C-1 and C-4′ positions (9); however, lipid A moieties containing pyrophosphate (PP) groups have also been reported (13). The presence of phosphate groups in lipid A greatly affects the endotoxic properties of LPS (22). Deletion of either of these groups reduces an endotoxic activity of the resulting monophosphorylated LPS by approximately 100-fold (18). For example, monophosphorylated lipid A has been used as an adjuvant in a hepatitis B vaccine in Europe (1, 12).Mass spectrometry (MS) has been widely used to gain information about the heterogeneity, i.e., the number of different species of lipid A families and a distribution of fatty acids on each glucosamine residue (2, 3, 9, 16, 20, 23, 28, 29, 30, 32, 35, 36). Detailed structural information, including the phosphorylation pattern of lipid A, can be obtained by tandem mass spectrometry. Several matrices have been used for the analysis of lipid A using matrix-assisted laser desorption ionization-time of flight MS (MALDI-TOF MS), including 2,5-dihydroxybenzoic acid (DHB), 2,4,6-trihydroxyacetophenone (THAP), and 6-aza-2-thiothymine (ATT) (8). Although DHB has been widely used for peptide analysis, it produces uneven crystals and leads to poor spot-to-spot reproducibility (3, 6, 11). Furthermore, the low solubility in the solvent compatible with lipid A and nonuniformity in a matrix layer (crystals) can lead to variations in the ionization yield across the sample resulting in formation of “hot” (or “sweet”) spots (14). On the other hand, 5-chloro-2-mercaptobenzothiazole (CMBT) was found to offer excellent spot-to-spot reproducibility because of the homogeneous crystallization of the analyte/matrix mixture over the sample spot (33). CMBT is soluble in methanol-chloroform-water (4:4:1, vol:vol:vol), a solvent compatible with lipid A molecules, especially hexaacylated species. Thus, it has been widely used for lipid A analysis (4, 9, 23, 35, 33). Interestingly, different preparation procedures for analysis of lipid A species dictate a selection of the preferred matrix system (10). For example, lipid A prepared using a TRI Reagent-based procedure with a CMBT matrix was preferable for the detection of phosphoethanolamine modifications (35). On the other hand, the analysis of lipid A prepared using an LPS extraction kit-based procedure with DHB was preferable for the detection of aminoarabinose modification (10). In addition, divalent cations, such as Ca2+ or Mg2+, can bridge the phosphorylated negatively charged groups between neighboring LPS molecules to form aggregates (24). Thus, there is a need for technologies capable of characterizing lipid A from biologically relevant samples in an accurate, rapid, and highly sensitive manner. Here we attempt to establish an optimized MALDI MS matrix system for the sensitive analysis of lipid A, especially its diphosphorylated forms, including both pyrophosphorylated and bisphosphorylated species. We also propose to incorporate a complex reagent (additive or comatrix) for reducing the interference of cations (5, 7, 15).  相似文献   

14.
15.
Nine Corallococcus isolates and three type strains of Corallococcus species were characterized by Intact Cell Mass Spectrometry using Matrix Assisted Laser Desorption Ionization Time-of-Flight (MALDI-TOF) mass spectrometry. The resulting phenetic clustering was compared to the phylogenetic grouping based upon sequences of two housekeeping genes. The three dendrograms of relatedness resembled each other in that the isolates were highly similar to the type strains of Corallococcus exiguus and Corallococcus coralloides, while Corallococcus macrosporus and Myxococcus xanthus were more distantly related. While certain pairs of organisms were recovered by spectrometry and genes sequence analysis, others were detected by two of the three approaches. The degree of similarity determined by sequence analysis of the two genes was not higher than that revealed by MALDI-TOF analysis. The results show that the spectral profile, consisting of about 25 to 45 masses ranging between 2 and 20 kDa, have indeed taxonomic significance, confirming literature data that ribosomal proteins and certain housekeeping proteins are responsible for the masses obtained. Provided the availability of a database of type strains, MALDI-TOF analysis of unknown strains appears to be a rapid and inexpensive method to taxonomically cluster environmental isolates, expanding the spectrum to strains other than those of medical importance predominantly investigated so far.  相似文献   

16.
Mass spectrometry (MS) represents a rapid technique for the identification of microbial monocultures, and its adaptation to the detection of pathogens in real-world samples is a public health and homeland security priority. Norovirus, a leading cause of gastroenteritis in the world, is difficult to monitor because it cannot be cultured outside the human body. The detection of norovirus capsid protein was explored using three common MS-based methods: scanning of intact proteins, peptide mass fingerprinting, and peptide sequencing. Detection of intact target protein was limited by poor selectivity and sensitivity. Detection of up to 16 target peptides by peptide mass fingerprinting allowed for the reproducible and confident (P < 0.05) detection of the 56-kDa norovirus capsid protein in the range of 0.1 × 10−12 to 50 × 10−12 mol in authentic standards of recombinant norovirus virus-like particles (VLPs). To explore assay performance in complex matrixes, a non-gel-based, rapid method (2 to 3 h) for virus extraction from human stool was evaluated (72% ± 12% recovery), and additional analyses were performed on norovirus-free stool extracts fortified with VLPs. Whereas peptide mass fingerprinting was rendered impractical by sample interferences, peptide sequencing using nanospray tandem MS facilitated unambiguous identification of ≥250 fmol of capsid protein in stool extracts. This is the first report on MS-based detection of norovirus, accomplished by using structurally identical, noninfective VLPs at clinically relevant concentrations. It represents an important milestone in the development of assays for surveillance of this category B bioterrorism agent.  相似文献   

17.
In the post-source decay (PSD) fragment spectrum of a reduced xyloglucan heptasaccharide (XXXGol) from tamarind seeds, eleven sodium-adduct fragment ions and a precursor ion [M + Na]+ were clearly observed by using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Each fragment ion interval corresponded to the absence of unhydroxylose, unhydroglucose, and glucitol residues, indicating that PSD fragmentation cleavage in the sugar compound occurred only at glycosidic linkages close to the oxygen atom of saccharide ring members, and not in inner sugar ring bonds. The PSD fragment ions were classified into two series, one involving the reducing end and the other involving the non-reducing end. Structural information from both the reducing and non-reducing ends could therefore be simultaneously obtained from the measurement of the positive ion mode. Almost all the fragment ions from species larger than trisaccharide residues could be detected in this PSD fragment experiment. Such fragmentation information will enable the structural determination of xyloglucan oligosaccharides.  相似文献   

18.
On-probe sample pretreatment using trifluoroacetic acid as an additional reagent enabled the direct detection of phospholipids in whole bacteria by means of matrix-assisted laser desorption ionization mass spectrometry for not only gram-negative organisms but also gram-positive ones with a thicker peptidoglycan layer.  相似文献   

19.
目的研究基质辅助激光解析电离飞行时间质谱(Matrix-Assisted Laser Desorption Ionization-Time of Flight MassSpectrometry,MALDI-TOF-MS)用于快速检测鉴定临床分离的酵母菌的可行性。方法应用Bruker MALDI-TOF-MS和VITEK 2-compact系统分别鉴定150株临床分离的酵母菌,结果不一致的菌株通过基因序列测定来鉴定。结果 MALDI-TOF-MS快速准确鉴定出了150株临床酵母菌,鉴定符合率在属水平上为100%,种水平上为94%。结论基于MALDI-TOF-MS鉴定方法具有很好的可重复性和准确性,并且其检测成本较低,实验准备时间很短,MALDI-TOF-MS可以用于临床分离的酵母菌的快速鉴定。  相似文献   

20.
Unique patterns of biomarkers were reproducibly characterized by matrix-assisted laser desorption ionization (MALDI)–mass spectrometry and were used to distinguish Bacillus species members from one another. Discrimination at the strain level was demonstrated for Bacillus cereus spores. Lipophilic biomarkers were invariant in Bacillus globigii spores produced in three different media and in B. globigii spores stored for more than 30 years. The sensitivity was less than 5,000 cells deposited for analysis. Protein biomarkers were also characterized by MALDI analysis by using spores treated briefly with corona plasma discharge. Protein biomarkers were readily desorbed following this treatment. The effect of corona plasma discharge on the spores was examined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号