首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sandwich format immunochromatographic assay for detecting foot-and-mouth disease virus (FMDV) serotypes was developed. In this rapid test, affinity purified polyclonal antibodies from Guinea pigs which were immunized with sucking-mouse adapted FMD virus (A/AV88(L) strain) were conjugated to colloidal gold beads and used as the capture antibody, and affinity purified polyclonal antibodies from rabbits which were immunized with cell-culture adapted FMD virus (A/CHA/09 strain) were used as detector antibody. On the nitrocellulose membrane of the immunochromatographic strip, the capture antibody was laid on a sample pad, the detector antibody was printed at the test line(T) and goat anti-guinea pigs IgG antibodies were immobilized to the control line(C). The lower detection limit of the test for a FMDV 146S antigen is 11.7ng/ml as determined in serial tests after the strip device was assembled and the assay condition optimization. No cross reactions were found with FMDV serotype C, Swine vesicular disease (SVD), Vesicular stomatiti svirus (VSV) and vesicular exanthema of swine virus (VES) viral antigens with this rapid test. Clinically, the diagnostic sensitivity of this test for FMDV serotypes A was 88.7% which is as same as an indirect-sandwich ELISA. The specificity of this strip test was 98.2% and is comparable to the 98.7% obtained with indirect-sandwich ELISA. This rapid strip test is simple, easy and fast for clinical testing on field sites; no special instruments and skills are required, and the result can be obtained within 15 min. To our knowledge, this is the first rapid immunochromatogarpic assay for serotype A of FMDV.  相似文献   

2.
Edema disease in piglets is caused by Shiga toxin 2e (Stx2e)‐producing Escherichia coli. However, there is currently no available Stx2e‐specific immunochromatographic test strip to differentiate Stx2e from other types of Shiga toxin 2. In the present study, to develop an Stx2e‐specific immunochromatographic test strip, we isolated nine different monoclonal antibody‐producing hybridoma clones from Stx2e toxoid‐immunized mice and confirmed that six antibodies were A subunit‐specific whereas three antibodies were B subunit‐specific. Only one A subunit‐specific monoclonal antibody (45B2) was cross‐reactive with prototype Stx2 (Stx2a) at the same sensitivity, but the remaining eight monoclonal antibodies were not. In immunochromatographic tests using the highly sensitive antibodies, test strips using some combinations of gold colloid‐conjugated monoclonal antibody with the B subunit‐specific monoclonal antibody on the membrane detected Stx2e, but not other types of Shiga toxin 2. These test strips had the ability to detect Stx2e in the culture supernatant of clinically isolated Stx2e gene‐positive strains, but not in those of Stx2e gene‐negative strains. These results indicate that our test strip is practical for the specific detection of Stx2e to diagnose swine edema disease.  相似文献   

3.
4.
In prostate cancer screening, prostate-specific antigen (PSA) has been utilized as a valuable biomarker. There are routinely used procedures based on enzyme-linked immunosorbent assay (ELISA) for PSA detection. The procedures based on ELISA, however, are time consuming, complicated, and costly. We have developed a rapid, very simple, cost effective and sensitive immunochromatographic assay using gold nanoparticles and evaluated its applications for first screening of prostate cancer in serum samples. The sensitive immunochromatographic assay requires only 40 μL of the serum sample. The assay used is rapid and simple, that it totally takes approx 15 min to complete. The method for sensitive immunochromatographic assay has the other advantage of decreasing the antibody concentration that is used for the test line. In this study, we show the advantage to decrease the antibody concentration and the evaluation of our sensitive immunochromatographic assay for the semiquantitative detection of PSA in serum. The results obtained from 163 serum samples using sensitive immunochromatographic assay are compared with the results obtained using the chemiluminescent enzyme immunoassay (CLEIA) and normal immunochromatographic assay. The results obtained in the sensitive immunochromatographic assay correlated well with the values obtained in CLEIA. We concluded that our sensitive immunochromatographic assay is applicable to the first screening test for the diagnosis of prostate cancer. Our developed sensitive immunochromatographic assay is a promising candidate for diagnosis or research use, which may become commercially available in the near future.  相似文献   

5.
We are developing hollow fiber-based specific antibody filters (SAFs) that selectively remove antibodies of a given specificity directly from whole blood, without separation of the plasma and cellular blood components and with minimal removal of plasma proteins other than the targeted pathogenic antibodies. A principal goal of our research is to identify the primary mechanisms that control antibody transport within the SAF and to use this information to guide the choice of design and operational parameters that maximize the SAF-based antibody removal rate. In this study, we formulated a simple mathematical model of SAF-based antibody removal and performed in vitro antibody removal experiments to test key predictions of the model. Our model revealed three antibody transport regimes, defined by the magnitude of the Damk?hler number Da (characteristic antibody-binding rate/characteristic antibody diffusion rate): reaction-limited (Da /= 10). For a given SAF geometry, blood flow rate, and antibody diffusivity, the highest antibody removal rate was predicted for diffusion-limited antibody transport. Additionally, for diffusion-limited antibody transport the predicted antibody removal rate was independent of the antibody-binding rate and hence was the same for any antibody-antigen system and for any patient within one antibody-antigen system. Using SAF prototypes containing immobilized bovine serum albumin (BSA), we measured anti-BSA removal rates consistent with transport in the intermediate regime (Da approximately 3). We concluded that initial SAF development work should focus on achieving diffusion-limited antibody transport by maximizing the SAF antibody-binding capacity (hence maximizing the characteristic antibody-binding rate). If diffusion-limited antibody transport is achieved, the antibody removal rate may be raised further by increasing the number and length of the SAF fibers and by increasing the blood flow rate through the SAF.  相似文献   

6.
7.
曾毅等报道,应用间接免疫荧光法(IIF)检测了8,279份正常成年人血清标本,发现3例T细胞白血病病毒(HTLV)抗体阳性:一例马杨氏,丈夫是日本人(HTLV抗体也阳性),侨居南京46年;第二例是台湾籍妇女;第三例是位侨居北京的日本人。650份各类白血病病人血清中,一例成人T细胞白血病患者HTLV抗体阳性,此人是船员,常去日本。  相似文献   

8.
Efficiency and sensitivity of indirect immunoperoxidase methods   总被引:3,自引:0,他引:3  
The peroxidase-antiperoxidase (PAP) complex method has repeatedly been claimed to be more sensitive and antibody efficient than the indirect peroxidase labeled antibody method. However, most studies comparing these methods used tissue sections as the test material. However, test systems with known amounts of antigen will allow more reliable comparison of these methods and quantitative evaluation of method sensitivity. We therefore compared the antibody efficiency and sensitivity of these methods for the detection of human chorionic gonadotropin in an enzyme linked immunosorbent assay (ELISA), an antigen spot test (AST) and tissue sections of choriocarcinoma. In the PAP technique rabbit PAP and goat anti-rabbit antibody were applied. The same antibody was peroxidase-labeled with the periodate technique and used in the labeled antibody method. In the ELISA the PAP method resulted in slightly higher antibody efficiency than the labeled antibody method. At low primary antibody dilutions the intensity of the reaction decreased with the PAP method but remained high with the labeled antibody method, in the ELISA as well as on tissue sections. In the AST the labeled antibody method and the PAP method appeared to be equally sensitive.  相似文献   

9.
P Perrin  S Morgeaux  P Sureau 《Biologicals》1990,18(4):321-330
The replacement of the in vivo potency test (NIH test) for rabies vaccine evaluation by in vitro methods is at present discussed in many reports and also by WHO expert working groups. For this purpose, in vitro glycoprotein titration has been proposed. Among the different glycoprotein assays, we have studied two ELISA methods (immunocapture and direct plate coating with the antigen to be tested) using neutralizing mono- and polyclonal antibodies. In our view, the immunocapture method based on the use of a neutralizing monoclonal anti-glycoprotein antibody seems to be a convenient tool for the determination of the in vitro potency of rabies vaccine and of the products corresponding to the different steps of their production process.  相似文献   

10.
An immunochromatographic strip test using gold nanoparticles was developed for the rapid detection of Salmonella typhi (S. typhi) in human serum. The strip test based on the principle of sandwich immunoassay by the specific binding of antigens from S. typhi O901 and antibody of S. typhi O901 on a nitrocellulose membrane. Antibody-gold nanoparticle conjugate was used as the label and was coated onto a glass fiber membrane, which was used as a conjugate pad. To create a test and control zone, antibody of S. typhi O901 and an anti-IgG were dotted on the nitrocellulose membrane, respectively. Positive samples were displayed as red dots at the test and control zones of the nitrocellulose membrane, while negative samples resulted in a red dot only in the control zone. The limit of detection (LOD) was found to be 1.14×10(5) cfu mL(-1), which could be visually detected by the naked eye within 15 min. This strip test provided a lower detection limit and analysis time than a dot blot immunoassay (8.88×10(6) cfu mL(-1) for LOD and 110 min for reaction time). In addition, our immunochromatographic strip test was employed to detect S. typhi in human serum effectively, with high accuracy. This strip test offers great promise for a rapid, simple and low-cost analysis of S. typhi.  相似文献   

11.
《BMJ (Clinical research ed.)》1971,4(5788):643-646
In October 1969 tests made on 1,457 students entering English universities and colleges showed that 57% already possessed antibody to EB virus. The students without antibody in these initial tests were retested seven months later and by then 12% had acquired antibody. In about one-third of them the acquisition of antibody was not associated with any illness. In about 20% respiratory and other illness had occurred, but these symptoms were almost equally frequent in students who had not acquired antibody. Nearly half had developed infectious mononucleosis. In students in whom the acquisition of EB virus antibody was associated with the clinical and haematological manifestations of infectious mononucleosis the Paul-Bunnell test was almost invariably positive. In contrast, when these manifestations were not associated with the acquisition of EB virus antibody the Paul-Bunnell test was always negative.Tests for cytomegalovirus antibody were also made on the students at entry. The proportion of students with this antibody was much less (30%) and only a small proportion (1·4%) of those without antibody had acquired cytomegalovirus antibody seven months later. In the only patient in whom the acquisition of cytomegalovirus antibody alone was associated with the clinical and haematological features of infectious mononucleosis the Paul-Bunnell test was negative.  相似文献   

12.
In this study, the multi-walled carbon nanotubes (MWCNTs) were applied in lateral flow strips (LFS) for semi-quantitative and quantitative assays. Firstly, the solubility of MWCNTs was improved using various surfactants to enhance their biocompatibility for practical application. The dispersed MWCNTs were conjugated with the methamphetamine (MET) antibody in a non-covalent manner and then manufactured into the LFS for the quantitative detection of MET. The MWCNTs-based lateral flow assay (MWCNTs-LFA) exhibited an excellent linear relationship between the values of test line and MET when its concentration ranges from 62.5 to 1500 ng/mL. The sensitivity of the LFS was evaluated by conjugating MWCNTs with HCG antibody and the MWCNTs conjugated method is 10 times more sensitive than the one conjugated with classical colloidal gold nanoparticles. Taken together, our data demonstrate that MWCNTs-LFA is a more sensitive and reliable assay for semi-quantitative and quantitative detection which can be used in forensic analysis.  相似文献   

13.
J G Lewis  K H Yeo  P A Elder 《Steroids》1986,47(6):365-372
An enzyme-linked immunosorbent assay (ELISA) for 11-deoxycortisol is described for the first time. 11-Deoxycortisol-thyroglobulin conjugate is adsorbed onto the wells of a 96-well ELISA plate and competes with 11-deoxycortisol in the standards or plasma extract for antibody binding sites. After washing, immobilized primary antibody is probed with peroxidase-labeled goat anti-rabbit IgG. The ELISA plate is further washed and o-phenylenediamine added, color developed and the absorbance read at 492 nm. The ELISA shows good agreement with our existing 11-deoxycortisol radioimmunoassay (RIA) and has similar specificity and performance which allow its use in the routine steroid laboratory for assessing pituitary adrenal function by the metyrapone test.  相似文献   

14.
Indirect hemagglutinating (IHA) antibody responses to Herpesvirus hominis types 1 and 2 (HVH-1 and HVH-2) were compared to complement-fixing and neutralizing antibody responses in immunized laboratory animals (rabbits, guinea pigs, and hamsters) and in natural infections of man. With the immunized animals, type specificity was seen only in the IHA test and only with antisera produced in hamsters and in the rabbits immunized with HVH-2. In human nongenital infections (considered to be caused predominately by HVH-1), IHA and neutralizing antibodies developed at about the same rate and reached approximately the same levels for HVH-1 and HVH-2. IHA titers tended to be higher than neutralizing antibody titers for both virus types. In genital infections (considered to be caused predominately by HVH-2), there was a rapid IHA antibody response to HVH-2, and the early HVH-2 antibody demonstrable by IHA, but not by neutralization tests, was found to be immunoglobulin M in nature. In genital infections, IHA titers for HVH-2 were markedly higher than neutralization titers, but there was no pronounced difference in neutralizing the IHA antibody titers for HVH-1. Several patients with genital infections fialed to develop IHA antibody for HVH-1. The IHA test possessed no greater sensitivity than did complement fixation or neutralization tests for serodiagnosis of HVH infections. Despite the fact that a number of patients with genital infections produced IHA antibody only for HVH-2, the test was no more effective than the neutralization test in providing a type-specific serodiagnosis of infection, due largely to the fact that the rapid IHA antibody response to HVH-2 prevented demonstration of a further, significant antibody titer increase in a number of cases.  相似文献   

15.
A cellular specific-locus mutation test is described for detecting mutant cells in mammals. The test is based upon the use of specific anti-C57BL/6J mouse hemoglobin antibody that binds hemoglobin “single” (hemoglobin s, present in C57BL/6J mouse) and not hemoglobin “diffuse” (hemoglobin d, present in DBA/2J mouse). Attempts to purify such antibody from pony and rabbit antisera through cross-absorption were unsuccessful. Immunization of LP/J mouse with C57BL/6J hemoglobin produced antiserum that reacted with s hemoglobin but not with d hemoglobin. In a fluorescent antibody technique, this antibody was found to label fixed red blood cells from C57BL/6J mice but not from DBA/2J mice. In a mixture of C57BL/6J and DBA/2J red cells, the C57BL/6J cells could be differentiated by their bright fluorescence from the non-fluorescent DBA/2J cells. Reconstruction experiment with artificial mixtures of DBA/2J and C57BL/6J cells showed that s hemoglobin bearing cells could be detected in DBA/2J red cells at frequencies as small as 0.4×10?6. Thus, the system is sensitive enough to detect d → s mutation in DBA/2J mice. Amino acid comparison of the globin chains of s and d hemoglobins shows that our antibody can probably detect mutations leading to a substitution of serine or proline by alanine at β20 position and/or a substitution of threonine by alanine at β139 position.  相似文献   

16.
用萄葡球菌菌体A蛋白(SPA)预先处理被检血清,以去除抗体IgG部份的竞争性结合,提高了间接免疫荧光法检查鼻咽癌病人血清中EB病毒膜抗原IgA(IgA/MA)抗体的敏感性及特异性,检查48例鼻咽癌病人血清IgA/MA抗体,阳性率为100%,血清几何平均滴度为141;40例其它恶性肿瘤病人和46例正常人都检不出IgA/MA抗体,免疫荧光法测得IgA/MA抗体阴性的6例鼻咽癌病人血清,SPA吸收后呈阳性反应,此改进方法可用以追踪观察鼻咽癌病的病程及预后。  相似文献   

17.
应用金黄地鼠作动物模型测定国内外四种流行性出血热灭活疫苗的保护率,并测定相应的中和抗体进行比较,发现四种疫苗对动物的保护率均较明显优于其中和抗体水平。说明保护力试验能较全面反映EHF疫苗的效力和质量水平。  相似文献   

18.
Pavoni E  Monteriù G  Cianfriglia M  Minenkova O 《Gene》2007,391(1-2):120-129
We report the development of a novel phagemid vector, pKM19, for display of recombinant antibodies in single-chain format (scFv) on the surface of filamentous phage. This new vector improves efficacy of selection and reduces the biological bias against antibodies that can be harmful to host bacteria. It is useful for generation of large new antibody libraries, and for the subsequent maturation of antibody fragments. In comparison with commonly used plasmids, this vector is designed to have relatively low expression levels of cloned scFv antibodies due to the amber codon positioned in a sequence encoding for the PhoA leader peptide. Moreover, fusion of antibodies to the carboxy terminal part only of the gene III protein improves display of scFv on bacteriophage surface in this system. Despite the lower antibody expression, the functional test performed with a new scFv library derived from human peripheral blood lymphocytes demonstrates that specific antibodies can be easily isolated from the library, even after the second selection round. The use of the pKM19 vector for maturation of an anti-CEA antibody significantly improves the final results. In our previous work, an analogous selection through the use of a phagemid vector, with antibody expression under the control of a lacP promoter, led to isolation of anti-CEA phage antibodies with improved affinities, which were not producible in soluble form. Probably due to the toxicity for E. coli of that particular anti-CEA antibody, 70% of maturated clones contained suppressed stop codons, acquired during various selection/amplification rounds. The pKM19 plasmid facilitates an efficient maturation process, resulting in selection of antibodies with improved affinity without any stop codons.  相似文献   

19.
This study reports a new capture ELISA (MM3-SERO) for the serodiagnosis of sheep fascioliasis, based on the use of the monoclonal antibody (mAb) MM3. Like our previously reported indirect ELISA method, based on the use of a FPLC-purified fraction (fraction IV) of the Fasciola hepatica excretion/secretion antigens (ESAs), this new test was able to detect animals infected with very small numbers of metacercariae (5-40) and showed no cross-reaction with sera from sheep infected with other parasites, i.e., Moniezia spp., Cysticercus tenuicollis, and Dicrocoelium dendriticum. In contrast with these 2 methods, some sera (mainly those obtained from animals infected with D. dendriticum) showed high reactivities in indirect ELISA with whole F. hepatica ESAs used as control. Interestingly, the MM3-SERO ELISA has a better signal-to-noise ratio than the fraction-IV ELISA, thus allowing detection of seroconversion in infected sheep on average 1 wk earlier (3.2 +/- 0.4 wk postinfection [PI] for MM3-SERO ELISA vs. 4.2 +/- 0.9 wk PI for fraction IV ELISA). Moreover, the antibody response detected with MM3-SERO ELISA was more uniform, with seroconversion always occurring at 4 wk PI in sheep with 1-2 flukes and at 3 wk PI in sheep with more than 2 flukes. The MM3-SERO ELISA was also used to evaluate the kinetics of antibody response against MM3-recognized antigens in sera from sheep experimentally infected with F. hepatica and then treated with triclabendazole. Our results showed that antibody levels dropped by about 25% during the 4-wk observation period following the flukicide treatment, whereas they remained invariably high in all sheep left untreated. We conclude that the MM3-SERO ELISA is a 100% sensitive and 100% specific test for the early serodiagnosis of sheep fascioliasis. Preliminary studies in our laboratory seem to indicate that this method may also be useful for the determination of anti-F. hepatica antibodies in serum and milk of other ruminants. A commercial version of MM3-SERO is currently available from BIO X Diagnostics (La Jemelle, Belgium).  相似文献   

20.
Bacteria and viruses may be transmitted to laboratory rodents by contaminated biological materials such as transplantable tumours, cell lines, sera or other biological materials. Biological materials are currently being screened using the mouse or rat antibody production (MAP/RAP) test (serological testing). We decided to test and validate an alternative assay using polymerase chain reaction (PCR/realtime PCR) technology to detect viral contamination directly in biological material. The aim of this study therefore is the validation of our new PCR assays and the comparison of PCR and the MAP test. For 8/14 viruses, conventional PCR was more sensitive and more specific than the MAP test in detecting murine viruses. For 12/14 viruses, the realtime PCR was more sensitive than the MAP test. In 2/14 cases, all three detection methods had the same sensitivity. Furthermore, PCR screening clearly conforms to the principles of the 3Rs as a replacement technique because it eliminates the need for using animals to screen for murine viruses in biological material.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号