首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A homogeneous detection mechanism based on fluorescence resonance energy transfer (FRET) has been developed for two DNA diagnostic tests. In the template-directed dye-terminator incorporation (TDI) assay, a donor dye-labeled primer is extended by DNA polymerase using allele-specific, acceptor dye-labeled ddNTPs. In the dye-labeled oligonucleotide ligation (DOL) assay, a donor dye-labeled common probe is joined to an allele-specific, acceptor dye-labeled probe by DNA ligase. Once the donor and acceptor dyes become part of a new molecule, intramolecular FRET is observed over background intermolecular FRET. The rise in FRET, therefore, can be used as an index for allele-specific ddNTP incorporation or probe ligation. Real time monitoring of FRET greatly increases the sensitivity and reliability of these assays. Change in FRET can also be measured by end-point reading when appropriate controls are included in the experiment. FRET detection proves to be a robust method in homogeneous DNA diagnostic assays.  相似文献   

3.
4.
We have developed and optimized a stopped-flow fluorescence assay for use in studying DNA unwinding catalyzed by Escherichia coli RecBCD helicase. This assay monitors changes in fluorescence resonance energy transfer (FRET) between a pair of fluorescent probes (Cy3 donor and Cy5 acceptor) placed on opposite sides of a nick in duplex DNA. As such, this is an "all-or-none" DNA unwinding assay. Single turnover DNA unwinding experiments were performed using a series of eight fluorescent DNA substrates containing duplex DNA regions ranging from 24 bp to 60 bp. The time-courses obtained by monitoring Cy3 fluorescence display a distinct lag phase that increases with increasing duplex DNA length, reflecting the transient formation of partially unwound DNA intermediates. These Cy3 FRET time-courses are identical with those obtained using a chemical quenched-flow kinetic assay developed previously. The signal from the Cy5 fluorescence probe shows additional effects that appear to specifically monitor the RecD helicase subunit. The continuous nature of this fluorescence assay enabled us to acquire more precise time-courses for many more duplex DNA lengths in a significantly reduced amount of time, compared to quenched-flow methods. Global analysis of the Cy3 and Cy5 FRET time-courses, using an n-step sequential DNA unwinding model, indicates that RecBCD unwinds duplex DNA with an average unwinding rate constant of kU = 200(+/-40) steps s(-1) (mkU = 680(+/-12)bp s(-1)) and an average kinetic step size, m = 3.4 (+/-0.6) bp step(-1) (5 mM ATP, 10 mM MgCl(2), 30 mM NaCl, pH 7.0, 5% (v/v) glycerol, 25.0 degrees C), in excellent agreement with the kinetic parameters determined using quenched-flow techniques. Under these same conditions, the RecBC enzyme unwinds DNA with a very similar rate. These methods will facilitate detailed studies of the mechanisms of DNA unwinding and translocation of the RecBCD and RecBC helicases.  相似文献   

5.
Transient kinetic analyses further support the role of the clamp-loader in bacteriophage T4 as a catalyst which loads the clamp onto DNA through the sequential hydrolysis of two molecules of ATP before and after addition of DNA. Additional rapid-quench and pulse-chase experiments have documented this stoichiometry. The events of ATP hydrolysis have been related to the opening/closing of the clamp protein through fluorescence resonance energy transfer (FRET). In the absence of a hydrolysable form of ATP, the distance across the subunit interface of the clamp does not increase as measured by intramolecular FRET, suggesting gp45 cannot be loaded onto DNA. Therefore, ATP hydrolysis by the clamp-loader appears to open the clamp wide enough to encircle DNA easily. Two additional molecules of ATP then are hydrolyzed to close the clamp onto DNA. The presence of an intermolecular FRET signal indicated that the dissociation of the clamp-loader from this complex occurred after guiding the polymerase onto the correct face of the clamp bound to DNA. The final holoenzyme complex consists of the clamp, DNA, and the polymerase. Although this sequential assembly mechanism can be generally applied to most other replication systems studied to date, the specifics of ATP utilization seem to vary across replication systems.  相似文献   

6.
A major product of oxidative damage to DNA, 8-oxo-7,8-dihydro-2'-deoxyguanine (8-oxoG), can lead to genomic mutations if it is bypassed unfaithfully by DNA polymerases in vivo. However, our pre-steady-state kinetic studies show that DNA polymerase IV (Dpo4), a prototype Y-family enzyme from Sulfolobus solfataricus, can bypass 8-oxoG both efficiently and faithfully. For the first time, our stopped-flow FRET studies revealed that a DNA polymerase altered its synchronized global conformational dynamics in response to a DNA lesion. Relative to nucleotide incorporation into undamaged DNA, three of the four domains of Dpo4 undertook different conformational transitions during 8-oxoG bypass and the subsequent extension step. Moreover, the rapid translocation of Dpo4 along DNA induced by nucleotide binding was significantly hindered by the interactions between the embedded 8-oxoG and Dpo4 during the extension step. These results unprecedentedly demonstrate that a Y-family DNA polymerase employs different global conformational dynamics when replicating undamaged and damaged DNA.  相似文献   

7.
8.
We sought to develop a novel competitive fluorescence resonance energy transfer (FRET)-aptamer-based strategy for detection of foot-and-mouth (FMD) disease within minutes. A 14-amino-acid peptide from the VP1 structural protein, which is conserved among 16 strains of O-serotype FMD virus, was synthesized and labeled with Black Hole Quencher-2 (BHQ-2) dye. Polyclonal FMD DNA aptamers were labeled with Alexa Fluor 546-14-dUTP by polymerase chain reaction and allowed to bind the BHQ-2-peptide conjugate. Following purification of the FRET–aptamer–peptide complex, a “lights off” response was observed within 10 minutes and was sensitive to a level of 25–250 ng/mL of FMD peptide. Ten candidate aptamers were sequenced from the polyclonal family. The aptamer candidates were screened in an enzyme-based plate assay. A high- and low-affinity aptamer candidate were each labeled with Alexa Fluor 546-14-dUTP by asymmetric polymerase chain reaction and used in the competitive FRET assay, but neither matched the sensitivity of the polyclonal FRET response, indicating the need for further screening of the aptamer library.  相似文献   

9.
A new method for specific detection of proteins based on fluorescence resonance energy transfer (FRET) using affinity proteins (affibodies) derived from combinatorial engineering of Staphylococcal protein A has been developed. Antiidiotypic affibody pairs were used in a homogeneous competitive binding assay, where the idiotypic, target-specific affibody was labeled with fluorescein and the antiidiotypic affibody was labeled with tetramethylrhodamine. Intermolecular FRET between the two fluorescent probes was observed in the antiidiotypic affibody complex, but upon addition of target protein the antiidiotypic affibody was displaced, which was monitored by a shift in the relative emission of the donor and acceptor fluorophores. The feasibility of the system was demonstrated by the detection of IgA and Taq DNA polymerase with high specificity, using two different antiidiotypic affibody pairs. Detection of Taq DNA polymerase in 25% human plasma was successfully carried out, demonstrating that the method can be used for analysis of proteins in samples of complex composition.  相似文献   

10.
A rapid real-time qRT-PCR assay for ovine beta-actin mRNA   总被引:2,自引:0,他引:2  
  相似文献   

11.
12.
A FRET peptide substrate was synthesized and evaluated for enzymatic cleavage by the BoNT/B light chain protease. The FRET substrate was found to be useful in both a high throughput assay to uncover initial ‘hits’ and a low throughput HPLC assay to determine kinetic parameters and modes of inhibition.  相似文献   

13.
A major goal of polymerase research is to determine the mechanism through which a nucleotide complementary to a templating DNA base is selected and delivered to the polymerase active site. Structural evidence suggests a large open-to-closed conformational change affecting the fingers subdomain as being crucial to the process. We previously designed a FRET system capable of measuring the rate of fingers subdomain closure in the presence of correct nucleotide. However, this FRET system was limited in that it could not directly measure the rate of fingers subdomain opening by FRET after polymerization or in the absence of DNA. Here we report the development of a new system capable of measuring both fingers subdomain closure and reopening by FRET, and show that the rate of fingers subdomain opening is limited only by the rate of polymerization. We anticipate that this system will scale down to the single molecule level, allowing measurement of fingers subdomain movements in the presence of incorrect nucleotide and in the absence of DNA.  相似文献   

14.
A fluorescent resonance energy transfer (FRET)-based hybridization assay for detecting multiplex ligation-dependent probe amplification (MLPA) products has been developed, extending the diagnostic power of the technique and demonstrating the possibility of combining MLPA with microarrays for the detection of multiple mutations. FRET is one of the most commonly used detection techniques for hybridization assays. To investigate the applicability of FRET based detection of MLPA products, a sandwich assay was designed to detect gene copy number by exploiting an immobilized probe labeled with an acceptor dye, Alexa Fluor 555, which hybridises to specific PCR amplicons, followed by hybridization of a second probe labeled with the donor dye, Alexa Fluor 488. Following excitation of the Alexa Fluor 488, a FRET signal was produced only if a DNA sequence specific to the BRCA1 exon 13 was present in the test sample. We have verified this assay on a DNA sample of a patient carrying a heterozygous BRCA1 exon 13 deletion using male genomic DNA as control. Here we demonstrate that the DNA sample containing the heterozygous deletion generated a considerably reduced FRET signal as compared to the control male human DNA. Our results show that the FRET design presented in this study can differentiate between reduced copy numbers any genomic DNA sequence after MLPA analysis, and the reported format is applicable to multiplex detection of MLPA products, using microarrays, or optical biosensor arrays, and future work will focus on the demonstration of this.  相似文献   

15.
A real-time polymerase chain reaction (PCR) assay with fluorescence resonance energy transfer (FRET) hybridisation probes combined with melting curve analysis was developed to detect Schistosoma japonicum in experimentally infected snails and in faecal samples of infected mice. This procedure is based on melting curve analysis of a hybrid between an amplicon from the S. japonicum internal transcribed spacer region 2 sequence, which is a 192-bp S. japonicum-specific sequence, and fluorophore-labelled specific probes. Real-time FRET PCR could detect as little as a single cercaria artificially introduced into a pool of 10 non-infected snails and a single egg inoculated in 100 mg of non-infected mouse faeces. All S. japonicum-infected snails and all faecal samples from infected mice were positive. Non-infected snails, non-infected mouse faeces and genomic DNA from other parasites were negative. This assay is rapid and has potential for epidemiological S. japonicum surveys in snails, intermediate hosts and faecal samples of final hosts.  相似文献   

16.
DNA polymerases discriminate between correct and incorrect nucleotide substrates during a "nonchemical" step that precedes phosphodiester bond formation in the enzymatic cycle of nucleotide incorporation. Despite the importance of this process in polymerase fidelity, the precise nature of the molecular events involved remains unknown. Here we report a fluorescence resonance energy transfer (FRET) system that monitors conformational changes of a polymerase-DNA complex during selection and binding of nucleotide substrates. This system utilizes the fluorescent base analogue 1,3-diaza-2-oxophenothiazine (tC) as the FRET donor and Alexa-555 (A555) as the acceptor. The tC donor was incorporated within a model DNA primer/template in place of a normal base, adjacent to the primer 3' terminus, while the A555 acceptor was attached to an engineered cysteine residue (C751) located in the fingers subdomain of the Klenow fragment (KF) polymerase. The FRET efficiency increased significantly following binding of a correct nucleotide substrate to the KF-DNA complex, showing that the fingers had closed over the active site. Fluorescence anisotropy titrations utilizing tC as a reporter indicated that the DNA was more tightly bound by the polymerase under these conditions, consistent with the formation of a closed ternary complex. The rate of the nucleotide-induced conformational transition, measured in stopped-flow FRET experiments, closely matched the rate of correct nucleotide incorporation, measured in rapid quench-flow experiments, indicating that the conformational change was the rate-limiting step in the overall cycle of nucleotide incorporation for the labeled KF-DNA system. Taken together, these results indicate that the FRET system can be used to probe enzyme conformational changes that are linked to the biochemical function of DNA polymerase.  相似文献   

17.
Histograms of single-molecule Förster resonance energy transfer (FRET) efficiency are often used to study the structures of biomolecules and relate these structures to function. Methods like probability distribution analysis analyze FRET histograms to detect heterogeneities in molecular structure, but they cannot determine whether this heterogeneity arises from dynamic processes or from the coexistence of several static structures. To this end, we introduce burst variance analysis (BVA), a method that detects dynamics by comparing the standard deviation of FRET from individual molecules over time to that expected from theory. Both simulations and experiments on DNA hairpins show that BVA can distinguish between static and dynamic sources of heterogeneity in single-molecule FRET histograms and can test models of dynamics against the observed standard deviation information. Using BVA, we analyzed the fingers-closing transition in the Klenow fragment of Escherichia coli DNA polymerase I and identified substantial dynamics in polymerase complexes formed prior to nucleotide incorporation; these dynamics may be important for the fidelity of DNA synthesis. We expect BVA to be broadly applicable to single-molecule FRET studies of molecular structure and to complement approaches such as probability distribution analysis and fluorescence correlation spectroscopy in studying molecular dynamics.  相似文献   

18.
19.
20.
In common with other DNA polymerases, DNA polymerase III holoenzyme of E. coli selects the biologically correct base pair with remarkable accuracy. DNA polymerase III is particularly useful for mechanistic studies because the polymerase and editing activities reside on separate subunits. To investigate the biochemical mechanism for base insertion fidelity, we have used a gel electrophoresis assay to measure kinetic parameters for the incorporation of correct and incorrect nucleotides by the polymerase (alpha) subunit of DNA polymerase III. As judged by this assay, base selection contributes a factor of roughly 10(4)-10(5) to the overall fidelity of genome duplication. The accuracy of base selection is determined mainly by the differential KM of the enzyme for correct vs. incorrect deoxynucleoside triphosphate. The misinsertion of G opposite template A is relatively efficient, comparable to that found for G opposite T. Based on a variety of other work, the G:A pair may require a special correction mechanism, possibly because of a syn-anti pairing approximating Watson-Crick geometry. We suggest that precise recognition of the equivalent geometry of the Watson-Crick base pairs may be the most critical feature for base selection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号