首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper, a novel amperometric glucose biosensor was constructed by alternative self-assembly of positively charged poly(diallydimethylammonium chloride) (PDDA) and negatively charged glucose oxidase (GOx) onto a 3D Nafion network via electrostatic adsorption. The amount of Nafion in the electrode and the number of the (PDDA/GOx)n multilayers were optimized to develop a sensitive and selective glucose biosensor. Under optimal conditions, the glucose biosensor with (PDDA/GOx)5 multilayers exhibited remarkable electrocatalytic activity, capable of detecting glucose with enhanced sensitivity of 9.55 μA/mM cm2 and a commendably low detection limit of 20 μM (S/N = 3). A linear response range of 0.05–7 mM (a linear correlation coefficient of 0.9984, n = 20) was achieved. In addition, the glucose biosensor demonstrated superior selectivity towards glucose over some interferents, such as ascorbic acid (AA) and uric acid (UA), at an optimized detection potential of 0.6 V versus Ag/AgCl reference.  相似文献   

2.
Xian Y  Hu Y  Liu F  Xian Y  Wang H  Jin L 《Biosensors & bioelectronics》2006,21(10):1996-2000
In this paper, we report a novel glucose biosensor based on composite of Au nanoparticles (NPs)-conductive polyaniline (PANI) nanofibers. Immobilized with glucose oxidase (GOx) and Nafion on the surface of nanocomposite, a sensitive and selective biosensor for glucose was successfully developed by electrochemical oxidation of H2O2. The glucose biosensor shows a linear calibration curve over the range from 1.0x10(-6) to 8.0x10(-4) mol/L, with a slope and detection limit (S/N=3) of 2.3 mA/M and 5.0x10(-7) M, respectively. In addition, the glucose biosensor system indicates excellent reproducibility (less than 5% R.S.D.) and good operational stability (over 2 weeks).  相似文献   

3.
In this study, a novel glucose biosensor was fabricated by reconstitutional immobilization of glucose oxidase (GOx) onto a poly(glycidyl methacrylate-co-vinylferrocene) (poly(GMA-co-VFc)) film coated pencil graphite electrode (PGE). The amperometric current response of poly(GMA-co-VFc)-GOx to glucose is linear in the concentration range between 1 and 16 mM (correlation coefficient of 0.9998) with a detection limit of 2.7 μM (S/N = 3). Experimental parameters were studied in detail and optimized, including the pH and temperature governing the analytical performance of the biosensor. The stability and reusability of the biosensor as well as its kinetic parameters have also been studied.  相似文献   

4.
The performance of a new glucose biosensor based on the combination of biocatalytic activity of glucose oxidase (GOx) with the electrocatalytic properties of CNTs and neutral red (NR) for the determination of glucose is described. This sensor is comprised of a multiwalled carbon nanotubes (MWNTs) conduit functionalized with NR and Nafion (Nf) as a binder and glucose oxidase as a biocatalyst. Neutral red was covalently immobilized on carboxylic acid groups of the CNTs via carbodiimide reaction. The functionalized MWNTs were characterized by microscopic, spectroscopic and thermal methods. The MWNT-NR-GOx-Nf nanobiocomposite was prepared by mixing the GOx solution with NR functionalized CNTs followed by mixing homogeneously with Nafion. The performance of the MWNT-NR-GOx-Nf nanobiocomposite modified electrode was examined by electrochemical impedance spectroscopy and cyclic voltammetry. The catalytic reduction of hydrogen peroxide liberated from the enzymatic reaction of glucose oxidase upon glucose with NR functionalized CNTs leads to the selective detection of glucose. The excellent electrocatalytic activity and the influence of nanobiocomposite film result in good characteristics such as low potential detection of glucose with a large determination range from 1 x 10(-8) to 1 x 10(-3)M with a detection limit of 3 x 10(-9)M glucose, a short response time (with 4s), good stability and anti-interferent ability. The improved electrocatalytic activity and stability made the MWNT-NR-GOx-Nf nanobiocomposite biosensor system a potential platform to immobilize different enzymes for other bioelectrochemical applications.  相似文献   

5.
For the first time glucose oxidase (GOx) was successfully co-deposited on nickel-oxide (NiO) nanoparticles at a glassy carbon electrode. In this paper we present a simple fabrication method of biosensor which can be easily operated without using any specific reagents. Cyclic voltammetry was used for electrodeposition of NiO nanoparticle and GOx immobilization. The direct electron transfer of immobilized GOx displays a pair of well defined and nearly reversible redox peaks with a formal potential (E(0')) of -0.420 V in pH 7 phosphate buffer solution and the response shows a surface controlled electrode process. The surface coverage and heterogeneous electron transfer rate constant (k(s)) of GOx immobilized on NiO film glassy carbon electrode are 9.45 x 10(-13)mol cm(-2) and 25.2+/-0.5s(-1), indicating the high enzyme loading ability of the NiO nanoparticles and great facilitation of the electron transfer between GOx and NiO nanoparticles. The biosensor shows excellent electrocatalytical response to the oxidation of glucose when ferrocenmethanol was used as an artificial redox mediator. Furthermore, the apparent Michaelis-Menten constant 2.7 mM, of GOx on the nickel oxide nanoparticles exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. In addition, this glucose biosensor shows fast amperometric response (3s) with the sensitivity of 446.2nA/mM, detection limit of 24 microM and wide concentration range of 30 microM to 5mM. This biosensor also exhibits good stability, reproducibility and long life time.  相似文献   

6.
A highly sensitive electrochemical glucose sensor has been developed by the co-immobilization of glucose oxidase (GOx) and horseradish peroxidase (HRP) onto a gold electrode modified with biocompatible cyclic bisureas–gold nanoparticle conjugate (CBU–AuNP). A self-assembled monolayer of mercaptopropionic acid (MPA) and CBU–AuNP was formed on the gold electrode through a layer-by-layer assembly. This modified electrode was used for immobilization of the enzymes GOx and HRP. Both the HRP and GOx retained their catalytic activity for an extended time, as indicated by the low value of Michaelis–Menten constant. Analytical performance of the sensor was examined in terms of sensitivity, selectivity, reproducibility, lower detection limit, and stability. The developed sensor surface exhibited a limit of detection of 100 nM with a linear range of 100 nM to 1 mM. A high sensitivity of 217.5 μA mM−1 cm−2 at a low potential of −0.3 V was obtained in this sensor design. Various kinetic parameters were calculated. The sensor was examined for its practical clinical application by estimating glucose in human blood sample.  相似文献   

7.
We report for the first time the development of a sensitive and selective glucose biosensor based on the self-assembling of multiwall carbon nanotubes (MWCNTs) dispersed in polyhistidine (Polyhis) and glucose oxidase (GOx) on glassy carbon electrodes (GCE). The supramolecular architecture was characterized by SEM, FT-IR and electrochemical techniques. The optimum multistructure was obtained with five (MWCNT-Polyhis/GOx) bilayers and one layer of Nafion as anti-interferent barrier. The sensitivity at 0.700V was (1.94±0.03) mAM(-1) (r=0.9991), with a linear range between 0.25 and 5.00mM, a detection limit of 2.2μM and a quantification limit of 6.7μM with minimum interference from lactose (1.5%), maltose (5.7%), galactose (1.2%), ascorbic acid (1.0%), and uric acid (3.3%). The biocatalytic layer demonstrated to be highly reproducible since the R.S.D. for 10 successive amperometric calibrations using the same surface was 3.6%. The sensitivity of the biosensor after 15 day storage at 4°C remained at 90% of its original value. The combination of the excellent dispersing properties and polycationic nature of polyhistidine, the stability of the MWCNT-Polyhis dispersion, the electrocatalytic properties of MWCNTs, the biocatalytic specificity of GOx, and the permselective properties of Nafion have allowed building up a sensitive, selective, robust, reproducible and stable glucose amperometric biosensor for the quantification of glucose in milk samples.  相似文献   

8.
The interfacial electron transfer of glucose oxidase (GOx) on a poly(glutamic acid)-modified glassy carbon electrode (PGA/GCE) was investigated. The redox peaks measured for GOx and flavin adenine dinucleotide (FAD) are similar, and the anodic peak of GOx does not increase in the presence of glucose in a mediator-free solution. These indicate that the electroactivity of GOx is not the direct electron transfer (DET) between GOx and PGA/GCE and that the observed electroactivity of GOx is ascribed to free FAD that is released from GOx. However, efficient electron transfer occurred if an appropriate mediator was placed in solution, suggesting that GOx is active. The PGA/GCE-based biosensor showed wide linear response in the range of 0.5–5.5 mM with a low detection limit of 0.12 mM and high sensitivity and selectivity for measuring glucose.  相似文献   

9.
A kind of nanocomposite with good dispersion in water was prepared through covalent adsorption of ferrocenecarboxaldehyde on multiwalled carbon nanotubes (MWNTs) for electrical communication between glucose oxidase (GOD) and electrode. The ferrocene-modified multiwalled carbon nanotube nanocomposites (MWNTs-Fc) could be conveniently cast on electrode surfaces. With the aid of chitosan, GOD was then immobilized on the nanostructure film to form a reagentless amperometric sensor for glucose determination. FTIR spectra and cyclic voltammetry were used to characterize the nanocomposites. The presence of both ferrocene as mediator of electron transfer and MWNTs as conductor enhanced greatly the enzymatic response to the oxidation of glucose. The novel biosensor exhibited a fast response toward glucose with a detection limit of 3.0 × 10−6 mol/L and the linear range extended up to 3.8 × 10−3 mol/L.  相似文献   

10.
A glucose amperometric biosensor based on the immobilization of glucose oxidase (GOx) in microparticles prepared by polymerization of the ionic liquid 1-vinyl-3-ethyl-imidazolium bromide (ViEtIm+Br) using the concentrated emulsion polymerization method has been developed. The polymerization of the emulsion dispersed phase, in which the enzyme was dissolved together with the ionic liquid monomer, provides poly(ViEtIm+Br) microparticles with entrapped GOx. An anion-exchange reaction was carried out for synthesizing new microparticles of poly(ViEtIm+(CF3SO2)2N) and poly(ViEtIm+BF4). The enzyme immobilization method was optimized for biosensor applications and the following optimal values were determined: pH 4.0 for the synthesis medium, 1.23 M monomer concentration and 3.2% (w/w) cross-linking content. The performance of the biosensor as a function of some analytical parameters such as pH and temperature of the measuring medium, and enzymatic load of the microparticles was also investigated. The effect of the substances which are present in serum samples such as uric and ascorbic acid was eliminated by using a thin Nafion layer covering the electrode surface. The biosensor thus prepared can be employed in aqueous and in non-aqueous media with satisfactory results for glucose determination in human serum samples. The useful lifetime of this biosensor was 150 days.  相似文献   

11.
Gu H  Yu Y  Liu X  Ni B  Zhou T  Shi G 《Biosensors & bioelectronics》2012,32(1):118-126
In this work, a novel amperometric biosensor for hydrogen peroxide was fabricated through the layer-by-layer (LBL) self-assembling of amine-terminated ionic liquid (IL-NH(2)), and sulfonic acid (SO(3)(-)) functionalized graphene by covalent bonding. The modification of the two functionalities introduced positive and negative charge onto the surface of graphene respectively, thus facilitating the formation of a multilayer film denoted with {IL-RGO/S-RGO}(n) through electrostatic interaction and further immobilization of glucose oxidase (GOx). The resulting {IL-RGO/S-RGO}(n)/GOx/Nafion biosensor displayed an excellent response to glucose at a potential of -200 mV. Combined with on-line microdialysis system, the glucose biosensor in the on-line system showed good linear range from 10 μM to 500 μM with the detection limit of 3.33 μM (S/N=3). Consequently, the basal level of glucose in the striatum of anesthetic rats was calculated to be 0.376 ± 0.028 mM (mean ± s.d., n=3). The {IL-RGO/S-RGO}(n)/GOx/Nafion biosensor was further applied for in vivo sensing of the glucose level in the striatum when rats received intraperitoneal (i.p.) injection of 30 μL insulin, which resulted in an obvious decrease in the extracellular concentration of glucose within 30 min. The method was proved to be sensitive and reproducible, which enabled its promising application in physiology and pathology.  相似文献   

12.
An amperometric glucose biosensor with glucose oxidase (GOx) immobilized into palladium hexacyanoferrate (PdHCF) hydrogel has been prepared and evaluated. The sensor was based on a two-layer configuration with biocatalytic and electrocatalytic layers separately deposited onto the electrode. To reduce the overpotential for reduction of hydrogen peroxide liberated in the enzyme catalyzed oxidation of glucose, an inner thin layer of nickel hexacyanoferrate (NiHCF) electrodeposited onto the surface of graphite electrode was used as an electrocatalyst. As an outer layer, the hydrogel of palladium hexacyanoferrate with entrapped glucose oxidase was used. Under optimal operating conditions (pH 5.0 and E = -0.075 V versus calomel (3.0 M KCl) reference electrode), sensor showed high sensitivity to glucose (0.3-1.0 microA/mM) and a response time of less than 30s. The linear response to glucose was obtained in the concentration range between 0.05 and 1.0 mM in batch analysis mode and 0-7.0 mM in FIA. During the 32 days testing period, no significant decrease in the sensor sensitivity was observed. The sensor was applied for the determination of glucose concentration in fruit juice and yoghurt drink, and the results obtained showed good correlation with results obtained by reference spectrophotometric enzyme method.  相似文献   

13.
A nanobiocomposite film consisted of polypyrrole (PPy), functionalized multiwalled carbon nanotubes (cMWNTs), and glucose oxidase (GOx) were electrochemically synthesized by electrooxidation of 0.1M pyrrole in aqueous solution containing appropriate amounts of cMWNTs and GOx. Potentiostatic growth profiles indicate that the anionic cMWNTs is incorporated within the growing PPy-cMWNTs nanocomposite for maintaining its electrical neutrality. The morphology of the PPy-cMWNTs nanocomposite was characterized by scanning electron microscopy (SEM). The PPy-cMWNTs nanocomposite was deposited homogeneously onto glassy carbon electrode. The amperometric responses vary proportionately to the concentration of hydrogen peroxide at the PPy-cMWNTs nanocomposite modified electrode at an operating potential of 0.7V versus Ag/AgCl (3M). The results indicate that the electroanalytical PPy-cMWNTs-GOx nanobiocomposite film was highly sensitive and suitable for glucose biosensor based on GOx function. The GOx concentration within the PPy-cMWNTs-GOx nanobiocomposite and the film thickness are crucial for the performance of the glucose biosensor. The amperometric responses of the optimized PPy-cMWNTs-GOx glucose biosensor (1.5 mgmL(-1) GOx, 141 mCcm(-2) total charge) displayed a sensitivity of 95 nAmM(-1), a linear range up to 4mM, and a response time of about 8s.  相似文献   

14.
A comparison of the analytical performances of several enzyme biosensor designs, based on the use of different tailored gold nanoparticle-modified electrode surfaces, is discussed. Glucose oxidase (GOx) and the redox mediator tetrathiafulvalene were coimmobilized in all cases by crosslinking with glutaraldehyde. The biosensor designs tested were based on the use of (i) colloidal gold (Au(coll)) bound on cysteamine (Cyst) monolayers self-assembled on a gold disk electrode (AuE) and (ii) glassy carbon electrodes (GCEs) modified with electrodeposited gold nanoparticles (nAu). The results obtained with these designs were compared with those provided by a GOx/Cyst-AuE and a GOx/MPA-AuE. In the second case (ii), configurations based on direct immobilization of GOx on nAu (GOx/nAu-GCE) or on Cyst or MPA self-assembled monolayers (SAMs) previously bound on gold nanoparticles (GOx/Cyst-nAu-GCE or GOx/MPA-nAu-GCE, respectively) were compared. The analytical characteristics of glucose calibration plots and the kinetic parameters of the enzyme reaction were compared for all of the biosensors tested. The GOx/Au(coll)-Cyst-AuE design showed a sensitivity for glucose determination higher than that achieved with GOx/Cyst-AuE and GOx/Au(coll)-Cyst/Cyst-AuE and similar to that achieved with GOx/MPA-AuE. Moreover, the useful lifetime of one single GOx/Au(coll)-Cyst-AuE was 28 days, remarkably longer than that of the other GOx biosensor designs.  相似文献   

15.
Glucose sensing electrodes have been realized by immobilizing glucose oxidase (GOx) on unmodified edge plane of highly oriented pyrolytic graphite (epHOPG) and the native oxide of heavily doped silicon (SiO2/Si). Both kinds of electrode show direct interfacial electron transfer due to the redox process of the immobilized GOx. The measured formal potential of the redox process agrees with that of the native enzyme, suggesting that the immobilized GOx has retained its enzymatic activity. The electron transfer rates of the GOx immobilized electrode are 2s(-1) for GOx/epHOPG electrode and 7.9s(-1) for GOx/SiO2/Si electrode, which are greater than those for which GOx is immobilized on modified electrodes, probably due to the fact that the enzyme makes direct contact to electrode surface. The preservation of the enzymatic activity of the immobilized GOx has been confirmed by observing the response of the GOx/epHOPG and GOx/SiO2/Si electrodes to glucose with a detection limit of 0.050 mM. The response signals the catalyzed oxidation of glucose and, therefore, confirms that the immobilized GOx retained its enzymatic activity. The properties of the electrode as a glucose sensor are presented.  相似文献   

16.
Aspergillus niger glucose oxidase (GOx) genes for wild-type (GenBank accession no. X16061, swiss-Prot; P13006) and M12 mutant (N2Y, K13E, T30 V, I94 V, K152R) were cloned into pPICZαA vector for expression in Pichia pastoris KM71H strain. The highest expression level of 17.5 U/mL of fermentation media was obtained in 0.5 % (v/v) methanol after 9 days of fermentation. The recombinant GOx was purified by cross-flow ultrafiltration using membranes of 30 kDa molecular cutoff and DEAE ion-exchange chromatography at pH 6.0. Purified wt GOx had k cat of 189.4 s?1 and K m of 28.26 mM while M12 GOx had k cat of 352.0 s?1 and K m of 13.33 mM for glucose at pH 5.5. Specificity constants k cat/K m of wt (6.70 mM?1 s?1) and M12 GOx (26.7 mM?1 s?1) expressed in P. pastoris KM71H were around three times higher than for the same enzymes previously expressed in Saccharomyces cerevisiae InvSc1 strain. The pH optimum and sugar specificity of M12 mutant of GOx remained similar to the wild-type form of the enzyme, while thermostability was slightly decreased. M12 GOx expressed in P. pastoris showed three times higher activity compared to the wt GOx toward redox mediators like N,N-dimethyl-nitroso-aniline used for glucose strips manufacturing. M12 mutant of GOx produced in P. pastoris KM71H could be useful for manufacturing of glucose biosensors and biofuel cells.  相似文献   

17.
A biosensor for the measurement of glucose in serum has been developed, based on a screen-printed carbon electrode modified with Meldola’s Blue-Reinecke salt, coated with the enzyme glucose dehydrogenase (from Bacillus sp.), and nicotinamide adenine dinucleotide coenzyme (NAD+). A cellulose acetate layer was deposited on top of the device to act as a permselective membrane. The biosensor was incorporated into a commercially available, thin-layer, amperometric flow cell operated at a potential of only +0.05 V versus Ag/AgCl. The mobile phase consisted of 0.2 M phosphate buffer (pH 7.0) containing 0.1 M potassium chloride solution, and a flow rate of 0.8 ml min−1 was used throughout the investigation. The biosensor response was linear over the range of 0.075-30 mM glucose, with the former representing the detection limit. The precision of the system was determined by carrying out 20 repeat injections of a 5-mM glucose standard, and the calculated coefficient of variation was 3.9%. It was demonstrated that this biosensor system could be applied to the direct measurement of glucose in serum without pretreatment. Therefore, this would allow high-throughput analysis, at low cost, for this clinically important analyte.  相似文献   

18.
We report on the utilization of a novel nanoscaled cobalt phthalocyanine (NanoCoPc)-glucose oxidase (GOD) biocomposite colloid to create a highly responsive glucose biosensor. The biocomposite colloid is constructed under enzyme-friendly conditions by adsorbing GOD molecules on CoPc nanoparticles via electrostatic interactions. The glucose biosensor can be easily achieved by casting the biocomposite colloid on a pyrolytic graphite electrode (PGE) without any auxiliary matter. It has been found that GOD can be firmly immobilized on PGE surface and maintain its bioactivity after conjugating with NanoCoPc. NanoCoPc displays intrinsic electrocatalytic ability to the oxidation of the product of enzymatic reaction H2O2 and shows a higher catalytic activity than that of bulk CoPc. Under optimal conditions, the biosensor shows a wide linear response to glucose in the range of 0.02-18 mM, with a fast response (5s), high sensitivity (7.71 microA cm(-2) mM(-1)), as well as good thermostability and long-term life. The detection limit was 5 microM at 3 sigma. The general interferences coexisted in blood except ascorbic acid and L-cysteine do not affect glucose determination, and further coating Nafion film on the surface of the biosensor can effectively eliminate the interference from ascorbic acid and L-cysteine. The biosensor with Nafion film has been used for the determination of glucose in serum with an acceptable accuracy.  相似文献   

19.
Using silver nanoparticle to enhance current response of biosensor   总被引:6,自引:0,他引:6  
In this paper, we present a simple procedure to increase the sensitivity of a glucose biosensor. The feasibility of an amperometric glucose biosensor based on immobilization of glucose oxidase (GOx) in silver (Ag) sol was investigated for the first time. GOx was simply mixed with Ag nanoparticles and cross-linked with a polyvinyl butyral (PVB) medium by glutaraldehyde. Then a platinum electrode was coated with the mixed solution. The effects of the amount of the Ag particles used, with respect to the current response for enzyme electrodes, were studied. A set of experimental results indicate that the current response for the enzyme electrode containing hydrophobic Ag sol increased from 0.531 to 31.17 microA in the solution of 10 mmol/L beta-D glucose. The time reaching the steady-state current response reduced from 60 to 20s, three times less than those without Ag particles involved.  相似文献   

20.
A novel glucose biosensor was fabricated. The first layer of the biosensor was polythionine, which was formed by the electrochemical polymerisation of the thionine monomer on a glassy carbon electrode. The remaining layers were coated with chitosan-MWCNTs, GOx, and the chitosan-PTFE film in sequence. The MWCNTs embedded in FAD were like “conductive wires” connecting FAD with electrode, reduced the distance between them and were propitious to fast direct electron transfer. Combining with good electrical conductivity of PTH and MWCNTs, the current response was enlarged. The sensor was a parallel multi-component reaction system (PMRS) and excellent electrocatalytic performance for glucose could be obtained without a mediator. The glucose sensor had a working voltage of −0.42 V, an optimum working temperature of 25°C, an optimum working pH of 7.0, and the best percentage of polytetrafluoroethylene emulsion (PTFE) in the outer composite film was 2%. Under the optimised conditions, the biosensor displayed a high sensitivity of 2.80 µA mM−1 cm−2 and a low detection limit of 5 µM (S/N = 3), with a response time of less than 15 s and a linear range of 0.04 mM to 2.5 mM. Furthermore, the fabricated biosensor had a good selectivity, reproducibility, and long-term stability, indicating that the novel CTS+PTFE/GOx/MWCNTs/PTH composite is a promising material for immobilization of biomolecules and fabrication of third generation biosensors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号