首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Due to the well-described spring-mass dynamics of bouncing gaits, human hopping is a tractable model for elucidating basic neuromuscular compensation principles. We tested whether subjects would employ a multi-joint or single-joint response to stabilize leg stiffness while wearing a spring-loaded ankle-foot orthosis (AFO) that applied localized resistive and assistive torques to the ankle. We analyzed kinematics and kinetics data from nine subjects hopping in place on one leg, at three frequencies (2.2, 2.4, and 2.8Hz) and three orthosis conditions (freely articulating AFO, AFO with plantarflexion resistance, and AFO with plantarflexion assistance). Leg stiffness was invariant across AFO conditions, however, compensation strategy depended upon the nature of the applied load. Biological ankle stiffness increased in response to a resistive load at twice the rate that it decreased with an assitive load. Ankle adjustments alone fully compensated for an assistive load with no net change in combined (biological plus applied) total ankle stiffness (p > or =0.133). In contrast, a resistive load resulted in a 7.4-9.0% increase in total ankle stiffness across frequencies and a concomitant 10-15% increase in knee joint stiffness at each frequency (p< or =0.037). The increased knee joint stiffness in response to resistive ankle load allowed subjects to maintain a more flexed knee at mid-stance, which attenuated the effect of the increased total ankle joint stiffness to preserve leg stiffness and whole limb biomechanical performance. Our findings suggest humans maintain invariant leg stiffness in bouncing gaits through different intralimb compensation strategies that are specific to the nature of the joint loading.  相似文献   

2.
Mechanical tuning of an ankle-foot orthosis (AFO) is important in improving gait in individuals post-stroke. Alignment and resistance are two factors that are tunable in articulated AFOs. The aim of this study was to investigate the effects of changing AFO ankle alignment on lower limb joint kinematics and kinetics with constant dorsiflexion and plantarflexion resistance in individuals post-stroke. Gait analysis was performed on 10 individuals post-stroke under four distinct alignment conditions using an articulated AFO with an ankle joint whose alignment is adjustable in the sagittal plane. Kinematic and kinetic data of lower limb joints were recorded using a Vicon 3-dimensional motion capture system and Bertec split-belt instrumented treadmill. The incremental changes in the alignment of the articulated AFO toward dorsiflexion angles significantly affected ankle and knee joint angles and knee joint moments while walking in individuals post-stroke. No significant differences were found in the hip joint parameters. The alignment of the articulated AFO was suggested to play an important role in improving knee joint kinematics and kinetics in stance through improvement of ankle joint kinematics while walking in individuals post-stroke. Future studies should investigate long-term effects of AFO alignment on gait in the community in individuals post-stroke.  相似文献   

3.
Plantarflexion resistance of an ankle-foot orthosis (AFO) plays an important role to prevent foot-drop, but its impact on push-off has not been well investigated in individuals post-stroke. The aim of this study was to investigate the effect of plantarflexion resistance of an articulated AFO on ankle and knee joint power of the limb wearing the AFO in individuals post-stroke. Gait analysis was performed on 10 individuals with chronic stroke using a Vicon 3-dimensional motion capture system and a Bertec split-belt instrumented treadmill. They walked on the treadmill under 4 plantarflexion resistance levels (S1 < S2<S3 < S4) set on the AFO with resistance adjustable ankle joints. The ankle and knee joint power calculations were performed using Visual3D, and mean values were plotted across a gait cycle. Statistical analyses revealed significant differences in the peak ankle joint power generation according to the plantarflexion resistance of the AFO (P = 0.008). No significant differences were found in the knee joint power. Peak ankle joint power generation [Median (IQR: Interquartile range)] were S1: 0.0517 (0.0238–0.1071) W/kg, S2: 0.0342 (0.0132–0.0862) W/kg, S3: 0.0353 (0.0127–0.0821) W/kg, and S4: 0.0234 (0.0087–0.06764) W/kg. Reduction of the peak ankle joint power generation appeared to be related to reduction in the peak plantarflexion angular velocity at late stance due to increases in the plantarflexion resistance of the AFO. This study showed that peak ankle joint power generation was significantly, and somewhat systematically, affected by plantarflexion resistance of the AFO in individuals post-stroke.  相似文献   

4.
Ankle foot orthoses (AFOs) are designed to improve gait for individuals with neuromuscular conditions and have also been used to reduce energy costs of walking for unimpaired individuals. AFOs influence joint motion and metabolic cost, but how they impact muscle function remains unclear. This study investigated the impact of different stiffness AFOs on medial gastrocnemius muscle (MG) and Achilles tendon (AT) function during two walking speeds. We performed gait analyses for eight unimpaired individuals. Each individual walked at slow and very slow speeds with a 3D printed AFO with no resistance (free hinge condition) and four levels of ankle dorsiflexion stiffness: 0.25 Nm/°, 1 Nm/°, 2 Nm/°, and 3.7 Nm/°. Motion capture, ultrasound, and musculoskeletal modeling were used to quantify MG and AT lengths with each AFO condition. Increasing AFO stiffness increased peak AFO dorsiflexion moment with decreased peak knee extension and peak ankle dorsiflexion angles. Overall musculotendon length and peak AT length decreased, while peak MG length increased with increasing AFO stiffness. Peak MG activity, length, and velocity significantly decreased with slower walking speed. This study provides experimental evidence of the impact of AFO stiffness and walking speed on joint kinematics and musculotendon function. These methods can provide insight to improve AFO designs and optimize musculotendon function for rehabilitation, performance, or other goals.  相似文献   

5.
ABSTRACT: BACKGROUND: Chronic ankle stiffness can develop for numerous reasons after traumatic injury, and may adversely affect patient gait, mobility, and function. Although standard physical therapeutic techniques typically resolve this stiffness, some cases may be recalcitrant to these measures, making it difficult to restore range-of-motion. The purpose of this study was to evaluate a static progressive stretch orthosis for the treatment of persistent ankle stiffness. METHODS: Twenty-six patients (26 ankles) who had persistent post-traumatic ankle stiffness were studied. The patients began treatment at a mean of 47 weeks (range, 6 to 272 weeks) following their initial injury using a static progressive stretch orthosis. A patient-directed protocol was used for 30 minutes per day, 1 to 3 times per day, until the range-of-motion was considered to have plateaued. Mean treatment time was 10 weeks (range, 3 to 19 weeks). Treatment duration, range-of-motion, and complications with the device were assessed. RESULTS: The overall mean improvement in motion (combined dorsiflexion and plantar flexion) was 17 degrees (range, 2 to 44 degrees). There was a mean improvement in dorsiflexion of 9 degrees (range, -2 to 20 degrees), and a mean improvement of 8 degrees of plantar flexion (range, -10 to 35 degrees). There were no reports of numbness or skin problems. CONCLUSIONS: The outcomes of this study suggest that a patient-directed treatment protocol using a static progressive stretch orthosis was an effective ancillary method for the treatment of persistent post-traumatic ankle stiffness that was refractory to standard physical therapy techniques. Key Words: ankle; stiffness; orthosis; progressive stress relaxation; rehabilitation.  相似文献   

6.
7.
The structural response of a posterior leaf spring, ankle-foot orthosis (AFO) was studied both experimentally and with a simple theoretical model. The theoretical model, which was compared with other analytical solutions and experimental data, predicted the bending and twisting of the AFO due to unit loads. The simple theoretical model utilized beam equations and small deflection theory. Excellent agreement between test and predicted values was achieved, indicating that the simple theoretical model, which was relatively easy to implement computationally, could serve as the major component of a computer-aided design program.  相似文献   

8.
The purpose of this study was to analyse the effect of a valgus knee orthosis designed for patients with knee osteoarthritis on the electromyographic activity (EMG) of seven muscles of the lower limb during gait. Twelve patients with medial knee osteoarthritis walked on a treadmill in three different conditions: without orthosis, with a knee orthosis in 4° valgus adjustment and with an orthosis in a neutral flexible adjustment. Root-mean-square (RMS) was analysed in each condition during a 150 ms pre-activation phase and during the stance phase of gait, which was divided in four sub-phases. In addition, co-contraction ratios (CCRs) were calculated between extensor/flexor, medial/lateral muscles and between agonist and antagonist muscle pairs. Significant decreases in muscle activity and CCRs were observed with the use of the knee orthosis in both adjustments compared to the condition without orthosis. Using the valgus brace, medial/lateral CCR decreased significantly during the late stance and the flexor/extensor CCR decreased significantly during the loading phase and late stance. Decreases of muscle pairs CCRs were observed with the neutral flexible adjustment. The results support the theory of a possible beneficial effect of knee braces in reducing knee loading by decreasing muscle activation and co-contraction levels, which could contribute to decelerate disease progression in patients with knee osteoarthritis.  相似文献   

9.
When humans hop or run on different surfaces, they adjust their effective leg stiffness to offset changes in surface stiffness. As a result, the overall stiffness of the leg-surface series combination remains independent of surface stiffness. The purpose of this study was to determine whether humans make a similar adjustment when springs are placed in parallel with the leg via a lower limb orthosis. We studied seven human subjects hopping in place on one leg while wearing an ankle-foot orthosis. We used an ankle-foot orthosis because the ankle joint is primarily responsible for leg stiffness during hopping. A spring was added to the ankle-foot orthosis so that it increased orthosis stiffness by providing plantar flexor torque during ankle dorsiflexion. We hypothesized that subjects would decrease their biological ankle stiffness when the spring was added to the orthosis, keeping total ankle stiffness constant. We collected kinematic, kinetic, and electromyographic data during hopping with and without the spring on the orthosis. We found that total ankle stiffness and leg stiffness did not change across the two orthosis conditions (ANOVA, P > 0.05). This was possible because subjects decreased their biological ankle stiffness to offset the orthosis spring stiffness (P < 0.0001). The reduction in biological ankle stiffness was accompanied by decreases in soleus, medial gastrocnemius, and lateral gastrocnemius muscle activation (P < 0.0002). These results suggest that an elastic exoskeleton might improve human running performance by reducing muscle recruitment.  相似文献   

10.

Introduction

Rigid Ankle-Foot Orthoses (AFOs) are commonly prescribed to counteract excessive knee flexion during the stance phase of gait in children with cerebral palsy (CP). While rigid AFOs may normalize knee kinematics and kinetics effectively, it has the disadvantage of impeding push-off power. A spring-like AFO may enhance push-off power, which may come at the cost of reducing the knee flexion less effectively. Optimizing this trade-off between enhancing push-off power and normalizing knee flexion in stance is expected to maximize gait efficiency. This study investigated the effects of varying AFO stiffness on gait biomechanics and efficiency in children with CP who walk with excessive knee flexion in stance. Fifteen children with spastic CP (11 boys, 10±2 years) were prescribed with a ventral shell spring-hinged AFO (vAFO). The hinge was set into a rigid, or spring-like setting, using both a stiff and flexible performance. At baseline (i.e. shoes-only) and for each vAFO, a 3D-gait analysis and 6-minute walk test with breath-gas analysis were performed at comfortable speed. Lower limb joint kinematics and kinetics were calculated. From the 6-minute walk test, walking speed and the net energy cost were determined. A generalized estimation equation (p<0.05) was used to analyze the effects of different conditions. Compared to shoes-only, all vAFOs improved the knee angle and net moment similarly. Ankle power generation and work were preserved only by the spring-like vAFOs. All vAFOs decreased the net energy cost compared to shoes-only, but no differences were found between vAFOs, showing that the effects of spring-like vAFOs to promote push-off power did not lead to greater reductions in walking energy cost. These findings suggest that, in this specific group of children with spastic CP, the vAFO stiffness that maximizes gait efficiency is primarily determined by its effect on knee kinematics and kinetics rather than by its effect on push-off power.

Trial Registration

Dutch Trial Register NTR3418  相似文献   

11.
Loss of mobility due to lower limb paralysis is a common result of thoracic level spinal cord injury. Functional electrical stimulation (FES) can restore primitive gait in the vicinity of a wheelchair by using electrical stimulation to generate muscle contractions. A new concept for FES-assisted gait is presented that combines electrical stimulation with an orthosis that contains a fluid power system to store and transfer energy during the gait cycle. The energy storage orthosis (ESO) can be driven through a complete gait cycle using only stimulation of the quadriceps muscles. The conceptual design of the ESO was completed and implemented in a dynamic simulation model and in a benchtop prototype for engineering measurements. No studies were conducted with human subjects. The results demonstrate the potential of the ESO concept for a feasible gait-assist system and the validity of the simulation model as a means for designing the system.  相似文献   

12.
Dopamine (DA) replacement therapy continues to be the gold standard treatment for Parkinson's disease (PD), as it improves key motor symptoms including bradykinesia and gait disturbances. With time, treatment induces side effects in the majority of patients, known as L‐DOPA‐induced dyskinesia (LID), which are often studied in animals by the use of unilateral, toxin‐induced rodent models. In this study, we used the progressive, genetic PD model MitoPark to specifically evaluate bilateral changes in motor behavior following long‐term L‐DOPA treatment at three different stages of striatal DA depletion. Besides locomotor activity, we assessed changes in gait with two automated gait analysis systems and the development of dyskinetic behavior. Long‐term treatment with a moderate, clinically relevant dose of L‐DOPA (8 mg/kg) gradually produced age‐dependent hyperactivity in MitoPark mice. In voluntary and forced gait analyses, we show that MitoPark mice with severe DA depletion have distinct gait characteristics, which are normalized to control levels following long‐term L‐DOPA treatment. The cylinder test showed an age‐dependent and gradual development of bilateral LID. Significant increase in striatal FosB and prodynorphin expression was found to accompany the behavior changes. Taken together, we report that MitoPark mice model both behavioral and biochemical characteristics of long‐term L‐DOPA treatment in PD patients and provide a novel, consistent and progressive animal model of dyskinesia to aid in the discovery and evaluation of better treatment options to counteract LID.  相似文献   

13.
A robotic tendon is a spring based, linear actuator in which the stiffness of the spring is crucial for its successful use in a lightweight, energy efficient, powered ankle orthosis. Like its human analog, the robotic tendon uses its inherent elastic nature to reduce both peak power and energy requirements for its motor. In the ideal example, peak power required of the motor for ankle gait is reduced from 250 W to just 77 W. In addition, ideal energy requirements are reduced from nearly 36 J to just 21 J. Using this approach, an initial prototype has provided 100% of the power and energy necessary for ankle gait in a compact 0.95 kg package, seven times less than an equivalent motor/gearbox system.  相似文献   

14.
An ankle-foot orthosis powered by artificial pneumatic muscles   总被引:3,自引:0,他引:3  
We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury.  相似文献   

15.
This paper deals with a design approach of a gait training machine based on a quantitative gait analysis.The proposed training machine is composed of a body weight support device and a cable-driven parallel robot.This paper is focused on the cable-driven robot,which controls the pose of the lower limb through an orthosis placed on the patient's leg.The cable robot reproduces a normal gait movement through the motion of the orthosis.A motion capture system is used to perform the quantitative analysis of a normal gait,which will be used as an input to the inverse dynamic model of the cable robot.By means of an optimization algorithm,the optimal design parameters,which minimize the tensions in the cables,are determined.Two constraints are considered,i.e.,a non-negative tension in the cables at all times,and a free cable/end-effector collision.Once the optimal solution is computed,a power analysis is carried out in order to size the robot actuators.The proposed approach can be easily extended for the design study of a similar type of cable robots.  相似文献   

16.
Background and Objectives: While body weight support (BWS) intonation is vital during conventional gait training of neurologically challenged subjects, it is important to evaluate its effect during robot assisted gait training. In the present research we have studied the effect of BWS intonation on muscle activities during robotic gait training using dynamic simulations. Methods: Two dimensional (2-D) musculoskeletal model of human gait was developed conjointly with another 2-D model of a robotic orthosis capable of actuating hip, knee and ankle joints simultaneously. The musculoskeletal model consists of eight major muscle groups namely; soleus (SOL), gastrocnemius (GAS), tibialis anterior (TA), hamstrings (HAM), vasti (VAS), gluteus maximus (GLU), uniarticular hip flexors (iliopsoas, IP), and Rectus Femoris (RF). BWS was provided at levels of 0, 20, 40 and 60% during the simulations. In order to obtain a feasible set of muscle activities during subsequent gait cycles, an inverse dynamics algorithm along with a quadratic minimization algorithm was implemented. Results: The dynamic parameters of the robot assisted human gait such as joint angle trajectories, ground contact force (GCF), human limb joint torques and robot induced torques at different levels of BWS were derived. The patterns of muscle activities at variable BWS were derived and analysed. For most part of the gait cycle (GC) the muscle activation patterns are quite similar for all levels of BWS as is apparent from the mean of muscle activities for the complete GC. Conclusions: Effect of BWS variation during robot assisted gait on muscle activities was studied by developing dynamic simulation. It is expected that the proposed dynamic simulation approach will provide important inferences and information about the muscle function variations consequent upon a change in BWS during robot assisted gait. This information shall be quite important while investigating the influence of BWS intonation on neuromuscular parameters of interest during robotic gait training.  相似文献   

17.
The oscillatory behavior of the center of mass (CoM) and the corresponding ground reaction force (GRF) of human gait for various gait speeds can be accurately described in terms of resonance using a spring–mass bipedal model. Resonance is a mechanical phenomenon that reflects the maximum responsiveness and energetic efficiency of a system. To use resonance to describe human gait, we need to investigate whether resonant mechanics is a common property under multiple walking conditions. Body mass and leg stiffness are determinants of resonance; thus, in this study, we investigated the following questions: (1) whether the estimated leg stiffness increased with inertia, (2) whether a resonance-based CoM oscillation could be sustained during a change in the stiffness, and (3) whether these relationships were consistently observed for different walking speeds. Seven healthy young subjects participated in over-ground walking trials at three different gait speeds with and without a 25-kg backpack. We measured the GRFs and the joint kinematics using three force platforms and a motion capture system. The leg stiffness was incorporated using a stiffness parameter in a compliant bipedal model that best fitted the empirical GRF data. The results showed that the leg stiffness increased with the load such that the resonance-based oscillatory behavior of the CoM was maintained for a given gait speed. The results imply that the resonance-based oscillation of the CoM is a consistent gait property and that resonant mechanics may be useful for modeling human gait.  相似文献   

18.
The gait pattern of a particular patient can be altered in a large set of pathologies. Tracking the body centre-of-mass (CoM) during the gait allows a quantitative evaluation of these diseases at comparing the gait with normal patterns. A correct estimation of this variable is still an open question because of its non-linearity and inaccurate location. This paper presents a novel strategy for tracking the CoM, using a biomechanical gait model whose parameters are determined by a Bayesian strategy. A particle filter is herein implemented for predicting the model parameters from a set of markers located at the sacral zone. The present approach is compared with other conventional tracking methods and decreases the calculated root mean squared error in about a 56% in the x-axis and 59% in the y-axis.  相似文献   

19.
Cao H  Liu D  Mo X  Xie C  Yao D 《Microbiological research》2011,166(6):475-483
Armillariella tabescens, a Chinese edible and medicinal fungus, whose multienzyme exist ability of AFB1-converting, and ADTZ (aflatoxin-detoxizyme) had previously purified from the A. tabescens multienzyme monitored by AFB1 conversion. However, the enzyme now confirmed an oxidase and renamed aflatoxin-oxidase (AFO). In this paper, AFO was purified by an economical and practical three-step procedure monitored by AFB1 conversion. And ESI-MS/MS analysis was done for identification of AFO. The following database searching (Protein Blast on NCBI) results did not show any homologous oxidase protein, which implied that AFO was mostly a new oxidase differing from other reported aflatoxin-converting enzymes such as fungal laccase and horse radish peroxidase. HPTLC analysis of the purified AFO activity suggested that the enzyme reacted at the bisfuran ring of AFB1 which was the key toxic structure. Therefore, all these investigations implied a new choice for biodegradation of aflatoxin in foods and feeds with the practical application of AFO.  相似文献   

20.
ABSTRACT: BACKGROUND: Fatigue in combination with gait and balance impairments can severely limit daily activities in people with multiple sclerosis (PWMS). Generalised fatigue has a major impact on walking ability, with moderately disabled PWMS experiencing difficulty in walking extended distances. Localised motor fatigue in the ankle dorsiflexors can lead to foot drop, further reducing functional ambulation. The aim of this study is to evaluate the effect of a simple dynamic dorsiflexion assist orthosis on walking-induced fatigue, gait, balance and functional mobility in PWMS. METHODS: A randomised cross-over trial will be conducted with 40 community dwelling PWMS with mild to moderate mobility disability. Participants will initially be screened for disease severity, balance, strength, depression and fatigue at the South Australian Motion Analysis Centre. On two non-consecutive occasions, within two weeks, participants will undergo either the 6-minute walk test (6MWT) or the 6MWT while wearing a dorsiflexion ankle orthosis (with a randomised condition order). Distance walked, perceived exertion, perceived fatigue and the physiological cost of walking (the primary outcome measures) will be compared between the two walking conditions. Additional pre- and post-6MWT assessments for the two conditions will include tests of strength, reaction time, gait and balance. DISCUSSION: This study will increase our understanding of motor fatigue on gait and balance control inPWMS and elucidate the effect of a Dynamic Ankle Orthosis on fatigue-related balance and gait in PWMS. It will also examine relationships between mobility and balance performance with perceived fatigue levels in this group. Trial Registration Number ACTRN12612000218897.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号