首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A SYBR Green LightCycler PCR assay using a single primer pair allowed simultaneous detection of stx1 and/or stx2 of Escherichia coli O157:H7. A distinct sequence of the Shiga-like toxin genes was amplified to yield products of 227 and/or 224 bp, respectively. The two products were distinguished by melting point curve analysis.  相似文献   

2.
A multiplex PCR-DNA probing assay was developed to detect four major Escherichia coli virotypes. Six highly specific polymerase chain reaction (PCR) primer sets and DIG-labeled chemiluminescent probes were designed to target the Shiga-like toxin I and II genes (stxI and stxII) of verotoxigenic E. coli (VTEC), heat-stable and heat-labile toxin genes of enterotoxigenic E. coli (ETEC), adherence factor (EAF) of enteropathogenic E. coli (EPEC) and a fragment of the invasiveness plasmid (IAL) of enteroinvasive E. coli (EIEC). The primer pairs generate products of 350, 262, 170, 322, 293 and 390 bp in length, respectively. The multiplex primers and probes were tested for specificity against 31 pathogenic E. coli strains, nine nonpathogenic E. coli and non-E.coli enteric and environmental bacterial strains. The results showed a high degree of specificity of the primers and probes for strains from corresponding virotypes and no reaction with the nontarget bacterial strains. The proposed multiplex PCR-DNA probing assay provides rapid and specific detection of four major virotypes of E. coli.  相似文献   

3.
The design and operating parameters affecting the performance of 5' nuclease PCR (TaqMan) assays for the detection of Listeria monocytogenes was investigated. A system previously developed and based on the hlyA gene was used as a model [Appl. Environ. Microbiol. 61 (1995) 3724]. A series of fluorogenic probes labeled with a reporter and a quencher dye was synthesized to explore the effect of probe position and sequence content on the efficiency of probe hydrolysis. In addition, a series of PCR primer pairs that altered the distance between the upstream primer and the interceding probe was examined. The effects of various assay parameters were evaluated by measuring the ratio of the fluorescence intensity of the reporter dye over the quencher dye (deltaRQ). For a given probe sequence, the deltaRQ was typically lower if the 5' terminus was a G residue. Decreasing the probe concentration increased the deltaRQ, although this was at the expense of reproducibility in the assay readout. The distance between the upstream primer and the interceding probe has a significant effect on probe hydrolysis. Reducing the primer-probe distance from, for example, 127 to 4 nt increased the deltaRQ from 2.87 to 5.00. These general rules were used to develop a 5' nuclease PCR (TaqMan) assay with enhanced signal output, providing higher and more reproducible deltaRQ values for L. monocytogenes detection.  相似文献   

4.
A PCR-ELISA for detecting Shiga toxin-producing Escherichia coli   总被引:2,自引:0,他引:2  
A sensitive and specific PCR-ELISA was developed to detect Escherichia coli O157:H7 and other Shiga toxin-producing E. coli (STEC) in food. The assay was based on the incorporation of digoxigenin-labeled dUTP and a biotin-labeled primer specific for Shiga toxin genes during PCR amplification. The labeled PCR products were bound to streptavidin-coated wells of a microtiter plate and detected by an ELISA. The specificity of the PCR was determined using 39 bacterial strains, including STEC, enteropathogenic E. coli, E. coli K12, and Salmonella. All of the STEC strains were positive, and non-STEC organisms were negative. The ELISA detecting system was able to increase the sensitivity of the PCR assay by up to 100-fold, compared with a conventional gel electrophoresis. The detection limit of the PCR-ELISA was 0.1-10 CFU dependent upon STEC serotypes, and genotypes of Shiga toxins. With the aid of a simple DNA extraction system, PrepMan, the PCR-ELISA was able to detect ca. 10(5) CFU of STEC per gram of ground beef without any culture enrichment. The entire procedure took about 6 h. Because of its microtiter plate format, PCR-ELISA is particularly suitable for large-scale screening and compatible with future automation.  相似文献   

5.
A multiplex PCR assay specifically detecting Escherichia coli O157 : H7 was developed by employing primers amplifying a DNA sequence upstream of E. coli O157 : H7 eaeA gene and genes encoding Shiga-like toxins (SLT) I and II. Analysis of 151 bacterial strains revealed that all E. coli O157 : H7 strains were identified simultaneously with the SLT types and could be distinguished from E. coli O55 : H7 and E. coli 055 : NM, and other non-O157 SLT-producing E. coli strains. Primer design, reaction composition (in particular, primer quantity and ratios), and amplification profile were most important in development of this multiplex PCR. This assay can serve not only as a confirmation test but also potentially can be applied to detect the pathogen in food.  相似文献   

6.
目的实现对致病性大肠埃希菌(E.coli)、沙门菌(Salmonella)的同时检测,建立快速灵敏的双重PCR检测方法。方法以致病性大肠埃希菌和沙门菌毒力岛基因为研究对象,根据GenBank发表的大肠埃希菌和沙门菌毒力岛基因序列,分别设计合成了大肠埃希菌毒力岛irpl、irl)2和fyuA,沙门菌毒力岛mgtC、sseL和sopB等6对引物,以禽致病性大肠埃希菌(CVCC1565)菌株和沙门菌(ATCC9150)菌株的核酸混合物为模板,经引物特异性试验,引物组合,成功建立了快速鉴别检测致病性大肠埃希菌和沙门菌的双重PCR方法。结果特异性试验结果显示,引物irpl、irp2和fyuA仅能扩增出大肠埃希菌(CVCC1565)的特异性片段,大小分别是799、414和948bp;引物mgtC、sseL和sopB仅能扩增出沙门菌(ATCC9150)的特异性片段,大小分别是500、269和1000bp。敏感性试验结果表明大肠埃希菌和沙门菌的最低检测限分别为2.2×101CFU/mL和2.0×101CFU/mL。结论本研究建立的双重PCR方法具有特异性强、敏感性高、快速简便等特点,可用于致病性大肠埃希菌和沙门菌的联合检测与鉴别诊断。  相似文献   

7.
The polymerase chain reaction (PCR) after a short enrichment culture was used to detect Campylobacter spp. in chicken products. After the 16S rRNA gene sequence of Campylobacter jejuni was determined and compared with known sequences from other enterobacteria, a primer and probe combination was selected from the region before V3 and the variable regions V3 and V5. With this primer set and probe, 426-bp fragments from C. jejuni, Campylobacter coli, and Campylobacter lari could be amplified. The detection limit of the PCR was 12.5 CFU. Chicken samples inoculated with 25 CFU of Campylobacter spp. per g were PCR positive after an 18-h enrichment, which resulted in 500 CFU/ml of culture broth. This PCR-culture assay was compared with the conventional method on naturally infected chicken products. Both methods detected the same number of positive and negative samples; however, the results of the PCR-culture assay were available within 48 h.  相似文献   

8.
The polymerase chain reaction (PCR) after a short enrichment culture was used to detect Campylobacter spp. in chicken products. After the 16S rRNA gene sequence of Campylobacter jejuni was determined and compared with known sequences from other enterobacteria, a primer and probe combination was selected from the region before V3 and the variable regions V3 and V5. With this primer set and probe, 426-bp fragments from C. jejuni, Campylobacter coli, and Campylobacter lari could be amplified. The detection limit of the PCR was 12.5 CFU. Chicken samples inoculated with 25 CFU of Campylobacter spp. per g were PCR positive after an 18-h enrichment, which resulted in 500 CFU/ml of culture broth. This PCR-culture assay was compared with the conventional method on naturally infected chicken products. Both methods detected the same number of positive and negative samples; however, the results of the PCR-culture assay were available within 48 h.  相似文献   

9.
A SYBR Green LightCycler PCR assay using a single primer pair allowed simultaneous detection of stx1 and/or stx2 of Escherichia coli O157:H7. A distinct sequence of the Shiga-like toxin genes was amplified to yield products of 227 and/or 224 bp, respectively. The two products were distinguished by melting point curve analysis.  相似文献   

10.
Molecular beacons (MBs) are oligonucleotide probes that fluoresce upon hybridization. In this paper, we described the development of a real-time PCR assay to detect the presence of Escherichia coli O157:H7 using these fluorogenic reporter molecules. MBs were designed to recognize a 26-bp region of the rfbE gene, coding for an enzyme necessary for O-antigen biosynthesis. The specificity of the MB-based PCR assay was evaluated using various enterohemorrhagic (EHEC) and Shiga-like toxin-producing (STEC) E. coli strains as well as bacteria species that cross-react with the O157 antisera. All E. coli serotype O157 tested was positively identified while all other species, including the closely related O55 were not detected by the assay. Positive detection of E. coli O157:H7 was demonstrated when >10(2) CFU/ml was present in the samples. The capability of the assay to detect E. coli O157:H7 in raw milk and apple juice was demonstrated. As few as 1 CFU/ml was detected after 6 h of enrichment. These assays could be carried out entirely in sealed PCR tubes, enabling rapid and semiautomated detection of E. coli O157:H7 in food and environmental samples.  相似文献   

11.
Surface water and groundwater are continuously used as sources of drinking water in many metropolitan areas of the United States. The quality of water from these sources may be reduced due to increases in contaminants such as Escherichia coli from urban and agricultural runoffs. In this study, a multiplex fluorogenic PCR assay was used to quantify E. coli O157:H7 in soil, manure, cow and calf feces, and dairy wastewater in an artificial wetland. Primers and probes were designed to amplify and quantify the Shiga-like toxin 1 (stx1) and 2 (stx2) genes and the intimin (eae) gene of E. coli O157:H7 in a single reaction. Primer specificity was confirmed with DNA from 33 E. coli O157:H7 and related strains with and without the three genes. A direct correlation was determined between the fluorescence threshold cycle (C(T)) and the starting quantity of E. coli O157:H7 DNA. A similar correlation was observed between the C(T) and number of CFU per milliliter used in the PCR assay. A detection limit of 7.9 x 10(-5) pg of E. coli O157:H7 DNA ml(-1) equivalent to approximately 6.4 x 10(3) CFU of E. coli O157:H7 ml(-1) based on plate counts was determined. Quantification of E. coli O157:H7 in soil, manure, feces, and wastewater was possible when cell numbers were >/=3.5 x 10(4) CFU g(-1). E. coli O157:H7 levels detected in wetland samples decreased by about 2 logs between wetland influents and effluents. The detection limit of the assay in soil was improved to less than 10 CFU g(-1) with a 16-h enrichment. These results indicate that the developed PCR assay is suitable for quantitative determination of E. coli O157:H7 in environmental samples and represents a considerable advancement in pathogen quantification in different ecosystems.  相似文献   

12.
AIMS: To evaluate PCR primers for the detection of pathogenic Escherichia coli in a real-time PCR assay and determine their utility in produce irrigation water testing. METHODS AND RESULTS: Three previously published PCR primer sets and one set designed for this study were tested for their ability to produce amplification products for several pathogenic E. coli serotypes from whole cells as template. Two of the previously published primer sets were chosen for real-time PCR detection limit determination. The coneaeA and PEH detection limit of E. coli O157:H7 was 10(0) and 10(1) CFU rxn(-1) in sterile water respectively. To detect E. coli O157:H7 in sprout irrigation water, the water required dilution due to PCR inhibitors. The detection limit of the coneaeA and PEH was 10(1) and between 10(2) and 10(3) CFU rxn(-1) in diluted sprout irrigation water respectively. CONCLUSIONS: The primer set coneaeA was able to produce an amplification product from each E. coli serotype, except O128:H7 and most sensitive for real-time PCR detection of pathogenic E. coli in diluted sprout irrigation water. SIGNIFICANCE AND IMPACT OF THE STUDY: The necessity of a dissociation analysis to distinguish positive samples from those with fluorescence of random dsDNA generation for real-time PCR in a complex background was established.  相似文献   

13.
AIMS: To evaluate the specificity and sensitivity of PCR primers for the detection of Salmonella enterica in a real-time PCR assay using pure cultures. METHODS AND RESULTS: Unenriched whole cells in sterile water were used as template for each PCR. SYBR Green dye was used for the nonspecific detection of dsDNA. The real-time PCR detection limits of five previously published primer sets used in conventional PCR applications were not below 3 x 10(3) CFU per reaction (rxn). A new primer set, Sen, was designed, which detected Salm. enterica Newport down to 6 CFU rxn(-1) in one case, and gave an average detection limit of 35 CFU rxn(-1) over three separate runs. CONCLUSIONS: Primers originally designed for end-point PCR did not have adequate specificity or sensitivity compared with those specifically designed for real-time PCR. SIGNIFICANCE AND IMPACT OF THE STUDY: This study emphasizes the importance of evaluating real-time PCR primer sets in pure cultures prior to testing in field samples. This study will benefit other researchers in selecting an appropriate primer set for real-time PCR detection of Salm. enterica.  相似文献   

14.
A rapid and sensitive method for detection of Shiga-like toxin (SLT)-producing Escherichia coli (SLT-EC) with the polymerase chain reaction (PCR) is described. Two pairs of oligonucleotide primers homologous to SLTI and SLTII genes, respectively, were used in multiplex PCR assays. The first pair generated a ca. 600-bp PCR product with DNA from all SLTI-producing E. coli tested but not from E. coli strains that produce SLTII or variants of SLTII. The second pair generated a ca. 800-bp PCR product with DNA from E. coli strains that produce SLTII or variants of SLTII but not from SLTI-producing E. coli. When used in combination, the SLTI and SLTII oligonucleotide primers amplified DNA from all of the SLT-EC tested. No PCR products were obtained with SLT primers with DNA from 28 E. coli strains that do not produce SLT or 44 strains of 28 other bacterial species. When ground beef samples were inoculated with SLT-EC strains 319 (O157:H7; SLTI and SLTII), H30 (O26:H11; SLTI), and B2F1/3 (O91:H21; SLTII variants VT2ha and VT2hb) and cultured in modified Trypticase soy broth for 6 h at 42 degrees C, an initial sample inoculum of as few as 1 CFU of these SLT-EC strains per g could be detected in PCR assays with DNA extracted from the broth cultures.  相似文献   

15.
A rapid and sensitive method for detection of Shiga-like toxin (SLT)-producing Escherichia coli (SLT-EC) with the polymerase chain reaction (PCR) is described. Two pairs of oligonucleotide primers homologous to SLTI and SLTII genes, respectively, were used in multiplex PCR assays. The first pair generated a ca. 600-bp PCR product with DNA from all SLTI-producing E. coli tested but not from E. coli strains that produce SLTII or variants of SLTII. The second pair generated a ca. 800-bp PCR product with DNA from E. coli strains that produce SLTII or variants of SLTII but not from SLTI-producing E. coli. When used in combination, the SLTI and SLTII oligonucleotide primers amplified DNA from all of the SLT-EC tested. No PCR products were obtained with SLT primers with DNA from 28 E. coli strains that do not produce SLT or 44 strains of 28 other bacterial species. When ground beef samples were inoculated with SLT-EC strains 319 (O157:H7; SLTI and SLTII), H30 (O26:H11; SLTI), and B2F1/3 (O91:H21; SLTII variants VT2ha and VT2hb) and cultured in modified Trypticase soy broth for 6 h at 42 degrees C, an initial sample inoculum of as few as 1 CFU of these SLT-EC strains per g could be detected in PCR assays with DNA extracted from the broth cultures.  相似文献   

16.
A multiplex PCR assay was devised and compared with standard conventional methods for quality evaluation of pharmaceutical raw materials and finished products with low levels of microbial contamination. Samples which were artificially contaminated with <10 colony forming units of Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, and Salmonella species and possibly contaminated samples were incubated for 16 h with different enrichment media. Primers that deduce 559 bp fragment of the 16S rRNA gene was employed in amplifying E. coli species, similarly invasion protein gene with 275 bp fragment size was used as target for detecting Salmonella spp., in case of S. aureus a 461 bp amplicon from m-RNA nuclease gene, and an 709 bp fragment from oprL gene was used for amplifying P. aeruginosa. The detection limits for artificially contaminants by multiplex PCR was 1 CFU/g, where as in case of conventional method the detection limit was >2 CFU/g. Similarly, when tested with possibly contaminated samples, 35% were detected for E. coli, Salmonella spp., S. aureus and P. aeruginosa species with multiplex PCR, while only 21% were detected with standard conventional microbial methods. Multiplex PCR assay provides sensitive and reliable results and allows for the cost-effective detection of all four bacterial pathogens in single reaction tube.  相似文献   

17.
Primers, specific for a unique base substitution in uidA of Escherichia coli O157:H7, were coupled with oligonucleotides for the shiga-like toxin I (SLT-I) and SLT-II genes in a multiplex PCR assay. A minimum of 10(2) CFU per PCR (10 microliters) was necessary to amplify E. coli O157:H7-specific bands by multiplex PCR. Food particles as well as various unknown metabolic by-products of bacteria inhibited the PCR, but a simple two-step filtration procedure eliminated this inhibition. To reliably generate PCR products, an E. coli inoculum of 10(3) CFU g of food slurry-1 in a nonspecific medium was required with 6 h of enrichment at 37 degrees C. However, when the food homogenate was incubated overnight, E. coli O157:H7 at an initial inoculum of even 1 CFU g-1 was detected.  相似文献   

18.
环介导等温扩增联合横向流动试纸条可视化检测志贺氏菌   总被引:2,自引:0,他引:2  
【目的】将环介导等温扩增技术(LAMP)与横向流动试纸条(LFD)联合应用,建立一种可应用于志贺氏菌快速检测的LAMP-LFD技术。【方法】以福氏志贺氏菌的侵袭性质粒抗原H(ipa H)基因为检测靶标设计3对特异性引物(其中上游内引物Sfl-ipa H-FIP由生物素标记),进行LAMP反应;同时设计1条异硫氰酸荧光素(FITC)标记的探针Sfl-ipa H-HP,与获得的LAMP产物进行特异性杂交,杂交产物经LFD完成检测。【结果】优化后的LAMP反应条件为63°C 40 min,加上LFD结果判读共需50 min。LAMP-LFD方法能够特异性检测出福氏志贺氏菌,而对肠炎沙门氏菌等其它4种导致腹泻的致病菌和创伤弧菌等5种常见食物源性致病菌,以及4株不同大肠杆菌的检测结果呈阴性。该方法针对福氏志贺氏菌的检测灵敏度为1.0×10~2 CFU/m L或4 CFU/反应,针对人工污染鲤鱼肠组织的检测灵敏度是5.0×10~2 CFU/m L,是以LAMP外引物Sfl-ipa H-F3/Sfl-ipa H-B3的常规PCR方法的100倍。【结论】建立的LAMP-LFD技术具有操作简单、检测快速准确、检测成本低等优点,有望在志贺氏菌的常规监测和即时检测中被普及使用。  相似文献   

19.
20.
目的:建立检测猪常见致病菌的反向斑点杂交方法。方法:将23S rRNA基因芯片用的针对12种细菌的25~30 mer探针加长到30~38 mer,2对通用引物序列不变。用地高辛标记下游引物,以尼龙膜为载体制备膜芯片,检验探针/膜杂交的特异性和敏感性;另外设计1条大肠杆菌K88基因探针、一段带K88探针的报告基因和1对报告基因的反向PCR引物,在PCR体系中增加封口的K88报告基因和反向引物对,被检样品扩增后进行膜杂交。结果:修改的13条探针与参考目标菌株在膜上成特异性杂交,对52个参考菌株和野外分离株的检测准确率为92%;膜杂交的敏感性与玻片芯片接近,最小检出量为100 fg DNA;在尼龙膜上增加K88探针,与3重PCR产物杂交,可以检测到大肠杆菌K88毒力基因。结论:建立的反向斑点杂交方法简便快速,检测成本低,可用于仪器设备不足的实验室,同时可以加入检测如大肠杆菌K88等致病基因,提高基于保守基因的芯片的诊断能力。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号