首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high-performance liquid chromatographic method has been developed for the simultaneous determination of mycophenolic acid (MPA) and its glucuronide conjugate (MPAG) in human plasma. The method involves protein precipitation with acetonitrile, followed by ion-pair reversed-phase chromatography on C18 column, with a 40 mM tetrabutyl ammonium bromide (TBA)–acetonitrile (65:35, v/v) mobile phase. A 20-μl volume of clear supernatant was injected after centrifugation, and the eluent was monitored at 304 nm. No interference was found either with endogenous substances or with many concurrently used drugs, indicating a good selectivity for the procedure. Calibration curves were linear over a concentration range of 0.5–20.0 μg/ml for MPA and 5–200 μg/ml for MPAG. The accuracy of the method is good, that is, the relative error is below 5%. The intra- and inter-day reproducibility of the analytical method is adequate with relative statistical deviations of 6% or below. The limits of quantification for MPA and MPAG were lower than 0.5 and 5.0 μg/ml, respectively, using 50 μl of plasma. The method was used to determine the pharmacokinetic parameters of MPA and MPAG following oral administration in a patient with renal transplantation.  相似文献   

2.
We extended the application of a sensitive high-performance liquid chromatography assay of amoxicillin developed in this laboratory for human plasma and middle ear fluid (MEF) to other sample matrices including chinchilla plasma or MEF and human and chinchilla whole blood with minor modification and validated the limit of quantitation at 0.25 μg/ml with a 50-μl sample size for human and chinchilla plasmas or MEFs. Amoxicillin and cefadroxil, the internal standard, were extracted from 50 μl of the samples with Bond Elut C18 cartridges. The extract was analyzed on a Keystone MOS Hypersil-1 (C8) column with UV detection at 210 nm. The mobile phase was 6% acetonitrile in 5 mM phosphate buffer, pH 6.5 and 5 mM tetrabutylammonium. The within-day coefficients of variation were 2.7–9.9 (n=4) and 1.7–7.2% (n=3) for chinchilla plasma and MEF samples, respectively; 2.8–8.1% (n=3) and 2.9–4.7% (n=3) for human and chinchilla whole blood, respectively. An alternative mobile phase composition for chinchilla plasma and MEF samples reduced the analysis time significantly.  相似文献   

3.
A rapid and sensitive liquid chromatography–electrospray ionisation mass spectrometry (HPLC–ESI-MS) assay has been developed for the measurement of moclobemide and metabolites, Ro12-5637 and Ro12-8095, in human plasma. Sample preparation (0.5 ml plasma) involves solid-phase extraction using C18 cartridges. A Nova-Pak phenyl column (Waters, 4 μm, 150×2 mm I.D.) was employed for analyte separation with a mixture of 0.2 M ammonium formate buffer, pH 3.57 and acetonitrile as the mobile phase. The within- and between-day precisions of the assay were <18% and the limit of quantification for all analytes was 0.01 μg/ml. The total run-time was 6 min. The method described was used to measure moclobemide, Ro12-5637 and Ro12-8095 in human plasma following an oral 300 mg dose.  相似文献   

4.
An isocratic high-performance liquid chromatographic method with column switching and direct injection has been developed to determine ciprofloxacin in plasma and Mueller–Hinton broth. An on-line dilution of the sample was performed with a loading mobile phase consisting of 173 mM phosphoric acid. The analyte was retained on a LiChrocart 4-4 precolumn filled with a LiChrospher 100 RP18, 5 μm. An electric-actuated system with two six-port valves allowed a clean-up step with a mixture 20 mM phosphate buffer (pH 3.5)–methanol (97: 3, v/v) and the transfer of the analyte by a back-flush mode to a 150×4.6 mm I.D. column packed with a Kromasil C8 5 μm, using a mobile phase of 20 mM phosphate buffer (pH 3.5)–acetonitrile (85:15, v/v). Fluorescence detection allowed a quantification limit of 0.078 μg/ml with a 40-μl sample size. The method was evaluated to determine its usefulness in studying the pharmacokinetic/pharmacodynamic behaviour of ciprofloxacin in an in vitro model.  相似文献   

5.
A method for the quantification of clindamycin in human serum and in human bone tissue samples applying high-performance liquid chromatography with atmospheric pressure chemical ionization–mass spectrometry (APCI–MS) is presented. Lincomycin is used as the internal standard. Serum samples are prepared only by protein precipitation with acetonitrile. Bone tissue samples have to be crushed and homogenized in extraction buffer prior to analysis. The chromatographic separation is achieved on an RP-18 stationary phase with 0.02% trifluoroacetic acid in water 60%/acetonitrile 40% v/v as mobile phase. The limits of quantification are 0.1 μg/ml for serum samples and 0.1 μg/g for bone tissue samples. The coefficients of variation for the assays are 4.48 and 8.41% at the limit of quantification for serum and bone tissue samples, respectively. Bone tissue samples as small as 50 mg can be used.  相似文献   

6.
A reversed-phase high-performance liquid chromatographic assay for the simultaneous determination of phenytoin and fosphenytoin, a prodrug for phenytoin, in human plasma and plasma ultrafiltrate is described. For plasma, the method involves simple extraction of drugs with diethyl ether and evaporation of solvent, followed by injection of the reconstituted sample onto a reversed-phase C18 column. Plasma ultrafiltrate is injected directly into the HPLC column. Compounds are eluted using an ion-pair mobile phase containing 20% acetonitrile. The eluent is monitored by UV absorbance at 210 nm. The fosphenytoin standard curves are linear in the concentration range 0.4 to 400 μg/ml for plasma and 0.03 to 80 μg/ml for ultrafiltrate. Phenytoin standard curves are linear from 0.08 to 40 μg/ml for plasma and from 0.02 to 5.0 μg/ml for ultrafiltrate. No interferences with the assay procedure were found in drug-free blank plasma or plasma ultrafiltrate. Relative standard deviation for replicate plasma or ultrafiltrate samples was less than 5% at concentrations above the limit of quantitation for both within- and between-run calculations.  相似文献   

7.
8.
An improved analytical method for the quantitative measurement of tianeptine and its main metabolite MC5 in human plasma was designed. Extraction involved ion-paired liquid–liquid extraction of the compounds from 1.0 ml of human plasma adjusted to pH 7.0. HPLC separation was performed using a Nucleosil C18, 5 μm column (150×4.6 mm I.D.) and a mixture of acetonitrile and pH 3, 2.7 g l−1 solution of sodium heptanesulfonate in distilled water (40:60, v/v) as mobile phase. UV detection was performed using a diode array detector in the 200–400 nm passband, and quantification of the analytes was made at 220 nm. For both tianeptine and MC5 metabolite, the limit of quantitation was 5 μg l−1 and the calibration curves were linear from 5 to 500 μg l−1. Intra- and inter-assay precision and accuracy fulfilled the international requirements. The recovery of tianeptine and its metabolite from plasma was, respectively, 71.5 and 74.3% at 20 μg l−1, 71.2 and 70.8% at 400 μg l−1. The selectivity of the method was checked by verifying the absence of chromatographic interference from pure solutions of the most commonly associated therapeutic drugs. This method, validated according to the criteria established by the Journal of Chromatography B, was applied to the determination of tianeptine and MC5-metabolite in human plasma in pharmacokinetic studies.  相似文献   

9.
A gas chromatography–electron capture mass spectrometry assay has been developed for the histamine H3 receptor agonist, Nα-methylhistamine (Nα-MH). The assay is linear from 50 pg–10 ng, with a limit of detection of 50 pg/ml for gastric juice and plasma, and 50 pg/sample for bacteria (107–108 CFU) and gastric tissue (5–10 mg wet weight). The limits of quantification are 100 pg/ml for gastric juice (%RSD=1.4) and plasma (%RSD=9.4), and 100 pg/sample for bacteria (%RSD=3.9) and tissue (%RSD=5.8). Nα-MH was not present in human plasma, but low levels (1.4 ng/ml and 0.4 ng/ml) were detected in two samples of human gastric juice obtained from patients infected with Helicobacter pylori.  相似文献   

10.
11.
We describe a novel sensitive and simplified gradient HPLC assay for quantification of the immunosuppressant mycophenolic acid (MPA) in rat and human plasma. In contrast to previously reported MPA assays, our method used a single step extraction comprising addition of acetonitrile, which contained phenolphthalein glucoronic acid as internal standard, for protein precipitation. Linearity: 0.1–100 μg/ml (r2>0.999), mean recoveries: MPA 98.0%, internal standard 105.2%, mean intra-day precision: 4.3%, mean day-to-day precision: 4.3%, mean day-to-day accuracy: −1.5%. Sensitivity was sufficient to allow for quantification of mycophenolic acid in as little as 50 μl plasma.  相似文献   

12.
A column-switching high-performance liquid chromatographic method for the simultaneous determination of five frequently prescribed benzodiazepines: clonazepam, diazepam, flunitrazepam, midazolam and oxazepam was developed. A 50-μl plasma sample was directly injected into a BioTrap 500 MS (hydrophobic polymer) column. After a washing step with a mixture of phosphate buffer and acetonitrile, the retained benzodiazepines were back-flushed into a reversed-phase (LiChrospher Select B C8) column with a mobile phase of acetonitrile–phosphate buffer. The method showed excellent linearity from 50 to 1000 ng/ml for clonazepam, flunitrazepam and midazolam and from 50 to 5000 ng/ml for diazepam and oxazepam. The recoveries were around 98% for all the benzodiazepines studied. The relative standard deviation for between- and within-day assay was <20% for low concentrations close to the values of the limit of quantification and <4% for high concentrations. The procedure described is relatively simple and rapid because no off-line manipulation of the sample is required: the total analysis time is approximately 30 min.  相似文献   

13.
A column-switching high-performance liquid chromatography (HPLC) method is described for the determination of asiaticoside in rat plasma and bile using column-switching and ultraviolet (UV) absorbance detection. Plasma was simply deproteinated with acetonitrile prior to injection and bile was directly injected onto the HPLC system consisting of a clean-up column, a concentrating column, and an analytical column, which were connected with two six-port switching valves. Detection of asiaticoside was accurate and repeatable, with a limit of quantification of 0.125 μg/ml in plasma and 1 μg/ml in bile. The calibration curves were linear in a concentration range of 0.125–2.5 μg/ml and 1–20 μg/ml for asiaticoside in rat plasma and bile, respectively. This method has been successfully applied to determine the level of asiaticoside in rat plasma and bile samples from pharmacokinetics and biliary excretion studies.  相似文献   

14.
A reliable high-performance liquid chromatographic method has been validated for determination of gallamine in rat plasma, muscle tissue and microdialysate samples. A C18 reversed-phase column with mobile phase of methanol and water containing 12.5 mM tetrabutyl ammonium (TBA) hydrogen sulphate (22:78, v/v) was used. The flow-rate was 1 ml/min with UV detection at 229 nm. Sample preparation involved protein precipitation with acetonitrile for plasma and muscle tissue homogenate samples. Microdialysate samples were injected into the HPLC system without any sample preparation. Intra-day and inter-day accuracy and precision of the assay were <13%. The limit of quantification was 1 μg/ml for plasma, 1.6 μg/g for muscle tissue and 0.5 μg/ml for microdialysate samples. The assay was applied successfully to analysis of samples obtained from a pharmacokinetic study in rats using the microdialysis technique.  相似文献   

15.
This study describes a HPLC method to determine the concentrations of acetylsalicylic acid (ASA) and salicylic acid (SA) in human stratum corneum and in plasma. The stratum corneum layers for ASA/SA analysis were removed from three patients with postherpetic hyperalgesia treated with topical and oral aspirin. Blood samples were also collected from the same patients. Tape strippings were placed in acetonitrile and sonicated for 15 min. After centrifuging, aliquots of the supernatant were injected into the chromatograph. ASA and SA from plasma samples were extracted on Isolute C8 columns. Due to interfering peaks in the tape samples, HPLC conditions were slightly different for tape and plasma samples. ASA and SA were separated on a LiChrospher 100 RP-18 column at 1 ml/min using a water–phosphate buffer (pH 2.5)–acetonitrile mobile phase (35:40:25, v/v/v). A linear response to quantities of ASA from 0.1 to 100 μg/cm2 and of SA from 0.1 to 5 μg/cm2 in tape and to quantities of ASA 0.1 to 2 μg/ml and 1 to 50 μg/ml was obtained and the recovery from tape and plasma samples was over 98%. The method is sensitive (0.1 μg/cm2) and specific enough to allow the determination of the drugs in the skin not only after topical but also after oral administration. A good sensitivity was also obtained in plasma (0.1 μg/ml) allowing study of the kinetics of ASA and SA in plasma after oral administration. Concentrations of ASA after topical administration were 100–200 times higher than after oral administration. Plasma levels of ASA and SA after oral administration were similar to those previously found. No ASA or SA were detected in plasma after topical ASA administration.  相似文献   

16.
A reliable reversed-phase high-performance liquid chromatographic method has been developed for the determination of bromocriptine (BCT) in plasma and eye tissues. The BCT and propranolol, added as an internal standard (I.S.), were extracted by a liquid–liquid technique followed by an aqueous back-extraction, allowing injection of an aqueous solvent into a 4-μm Nova-Pak C18 column (150×3.9 mm I.D.). The mobile phase was a mixture of 30 parts of acetonitrile and 70 parts of 0.2% triethylamine (pH 3) at a flow-rate of 1 ml/min. Fluorescence detection was at an excitation wavelength of 330 nm and an emission wavelength of 405 nm. The retention times of I.S. and BCT were 4.1 and 11.6 min, respectively. The calibration curve was linear over the concentration range 0.2–10 μg/l for plasma (r>0.999) and vitreous humour (r>0.997) and 1–50 μg/l for aqueous humour (r>0.985). The limit of quantification was 0.2 μg/l for plasma and vitreous humour using a 1-ml sample and was 1 μg/l for aqueous humour using a 0.2-ml sample. The quality control samples were reproducible with acceptable accuracy and precision. The within-day recovery (n=3) was 100–102% for plasma, 91–106% for aqueous humour and 96–111% for vitreous humour. The between-day recovery (n=9) was 90–114% for plasma, 83–115% for aqueous humour and 90–105% for vitreous humour. The within-day precision (n=3) and the between-day precision (n=9) were 1.7–7.0% and 8.1–13.6%, respectively. No interferences from endogenous substances were observed. Taken together, the above simple, sensitive and reproducible high-performance liquid chromatography assay method was suitable for the determination of BCT in plasma and eye tissues following ocular application of BCT for the therapy of myopia.  相似文献   

17.
A high-performance liquid chromatographic method has been developed for the determination of a new cephalosporin antibiotic in plasma, urine and saliva (mixed saliva) using normal-phase technique and an NH2 bonded-phase column. The eluent mixture was a combination of acetonitrile and an aqueous solution of ammonium carbonate. The rapid method involved precipitation of protein from fluids by means of acetonitrile followed by automatic injection of the supernatant. The detection limit was 0.4 μg/ml for plasma, 3 μg/ml for urine and 0.03 μg/ml for saliva using UV detection.  相似文献   

18.
A simple and highly sensitive method has been developed for the determination in plasma of ciprostene, 9β-methyl-6α-carbaprostaglandin I2, using gas chromatography—mass spectrometry following solid-phase extraction on an immobilized antibody column. The anti-ciprostene antibody obtained from rabbit serum was coupled to an agarose support matrix, and the immobilized antibody thus prepared was used as an extraction phase for sample clean-up. The extracted drug was treated with pentafluorobenzyl bromide followed by bis(trimethylsilyl)trifluoroacetamide. The derivative was quantitatively analysed by negative-ion chemical ionization gas chromatography—mass spectrometry. The lower limit of quantitation was 50 pg/ml when 1 ml of human plasma was used. The plasma concentration of ciprostene in a dog treated with ciprostene at 2.5 μg/kg was determined successfully by this method.  相似文献   

19.
Methods for the determination of celecoxib in human plasma and rat microdialysis samples using liquid chromatography tandem mass spectrometry are described. Celecoxib and an internal standard were extracted from plasma by solid-phase extraction with C18 cartridges. Thereafter compounds were separated on a short narrow bore RP C18 column (30×2 mm). Microdialysis samples did not require extraction and were injected directly using a narrow bore RP C18 column (70×2 mm). The detection was by a PE Sciex API 3000 mass spectrometer equipped with a turbo ion spray interface. The compounds were detected in the negative ion mode using the mass transitions m/z 380→316 and m/z 366→302 for celecoxib and internal standard, respectively. The assay was validated for human plasma over a concentration range of 0.25–250 ng/ml using 0.2 ml of sample. The assay for microdialysis samples (50 μl) was validated over a concentration range of 0.5–20 ng/ml. The method was utilised to determine pharmacokinetics of celecoxib in human plasma and in rat spinal cord perfusate.  相似文献   

20.
A sensitive gas chromatographic–mass spectrometric method is described for reliably measuring endogenous uracil in 100 μl of human plasma. Validation of this assay over a wide concentration range, 0.025 μM to 250 μM (0.0028 μg/ml to 28 μg/ml), allowed for the determination of plasma uracil in patients treated with agents such as eniluracil, an inhibitor of the pyrimidine catabolic enzyme, dihydropyrimidine dehydrogenase. Calibration standards were prepared in human plasma using the stable isotope, [15N2]uracil, to avoid interference from endogenous uracil and 10 μM 5-chlorouracil was added as the internal standard.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号