首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for determining operator protection factors in Class I and Class II microbiological safety cabinets and for evaluating product protection factors in Class II cabinets, is described. The technique employs an aerosol of potassium iodide droplets produced by a spinning disc generator together with special centripetal air samplers detecting any aerosol escape. The method meets the requirements of British Standard (BS) 5726 and is an alternative to the microbiological technique.
The method has been used to evaluate the performance of a number of safety cabinets in relation to the requirements of BS 5726.
Working procedures and unsuitable environments have been shown to prejudice the containment performance of open-fronted cabinets by several orders of magnitude.
The relationship between inflow air velocity and protection factors in Class I safety cabinets has confirmed the optimum requirements defined in the British Standard.  相似文献   

2.
Open fronted safety cabinets in ventilated laboratories   总被引:1,自引:0,他引:1  
Open fronted Class I and II microbiological safety cabinets (MSCs) are required by the British Standard 5726 to provide similar levels of operator protection (viz. 105). In laboratories that are naturally ventilated large numbers of both types of cabinets have been shown to exceed this requirement consistently over a number of years. The designs of some mechanically ventilated laboratories, however, produce excessive turbulence and draughts that can prejudice containment at the front aperture. On-site commissioning tests to determine operator protection factor are now well established and are recognized as being essential to the setting up of all open fronted cabinets in both ventilated and unventilated laboratories. This paper shows that where environmental conditions induce unsatisfactory cabinet containment, adjustments to air supply and exhaust systems can be made which will enable both Class I and II cabinets to produce operator protection factors in excess of 105. When compatibility is achieved between the local environment and the cabinets it is demonstrated that disturbances at the front aperture, caused by operator working procedures or by disturbances due to personnel movement within the room, have similar effects on both Class I and II cabinets. Once performance levels have been satisfactorily achieved, regular containment testing has shown that consistent performance can be maintained. These aspects of open fronted safety cabinet performance are discussed in relation to ventilated laboratories suitable for work with the human immunodeficiency virus (HIV). Of paramount importance in the future is the necessity to design laboratory air systems that will be compatible with satisfactory safety cabinet performance—a relatively new requirement in ventilation system specifications.  相似文献   

3.
The considerable refinements necessary to enable Class I and II microbiological safety cabinets to operate in a force-ventilated laboratory and to meet appropriate safety criteria have been reported previously. The continued successful operation of such cabinets without a deterioration of operator protection is described. The performance of two Class II units, one meeting and one failing the current British Standard applied to four head KI-discus testing, is compared and discussed. In addition, some further potential difficulties within the environment, which could compromise cabinet containment, are highlighted.  相似文献   

4.
R.W. OSBORNE AND T.A. DURKIN. 1991. The considerable refinements necessary to enable Class I and II microbiological safety cabinets to operate in a force-ventilated laboratory and to meet appropriate safety criteria have been reported previously. The continued successful operation of such cabinets without a deterioration of operator protection is described. The performance of two Class II units, one meeting and one failing the current British Standard applied to four head KI-Discus testing, is compared and discussed. In addition, some further potential difficulties within the environment, which could compromise cabinet containment, are highlighted.  相似文献   

5.
The deposition patterns of large-particle microbiological aerosols within the respiratory tract are not well characterized. A novel system (the flow-focusing aerosol generator [FFAG]) which enables the generation of large (>10-μm) aerosol particles containing microorganisms under laboratory conditions was characterized to permit determination of deposition profiles within the murine respiratory tract. Unlike other systems for generating large aerosol particles, the FFAG is compatible with microbiological containment and the inhalational challenge of animals. By use of entrapped Escherichia coli cells, Bacillus atrophaeus spores, or FluoSphere beads, the properties of aerosols generated by the FFAG were compared with the properties of aerosols generated using the commonly available Collison nebulizer, which preferentially generates small (1- to 3-μm) aerosol particles. More entrapped particulates (15.9- to 19.2-fold) were incorporated into 9- to 17-μm particles generated by the FFAG than by the Collison nebulizer. The 1- to 3-μm particles generated by the Collison nebulizer were more likely to contain a particulate than those generated by the FFAG. E. coli cells aerosolized using the FFAG survived better than those aerosolized using the Collison nebulizer. Aerosols generated by the Collison nebulizer and the FFAG preferentially deposited in the lungs and nasal passages of the murine respiratory tract, respectively. However, significant deposition of material also occurred in the gastrointestinal tract after inhalation of both the small (89.7%)- and large (61.5%)-particle aerosols. The aerosols generated by the Collison nebulizer and the FFAG differ with respect to mass distribution, distribution of the entrapped particulates, bacterial survival, and deposition within the murine respiratory tract.  相似文献   

6.
A recent resolution of the Parliamentary Assembly of Europe (No. 986–1992) emphasizes that technical innovation is an important and continuing feature of modern society and that it will act as the driving force in commercial and industrial competition for a long while to come. The public draws substantial benefits from this technological progress but has also developed a keen awareness of the supposed effects of certain technologies on the ethical values on which society is based, on health and on the environment.
In this context, the issue of risks (particularly those present in certain new technologies) becomes more complex. Despite a general improvement in safety levels and a substantial reduction in traditional risks, new types of risks, far more difficult to calculate and predict, are emerging. This is especially true in the chemical, pharmaceutical and biotechnology industries where these difficulties have been recognized and where safe systems of work and equipment are therefore being developed that can effectively contain potentially hazardous material.
Of particular significance over the last 10 years in this area has been the marked improvement in the design and performance of safety cabinets and related containment systems for microbiological use. In the UK this has been due to a number of factors including the implementation of the requirements of BS 5726 1979 (Microbiological safety cabinets) (Anon. 1979) which have been complimentary to the COSHH (Control of Substances Hazardous to Health) Regulations (Anon. 1988) which themselves reinforced the Health and Safety at Work Act (Anon. 1974). Taken together, this framework has been responsible for significant improvements to the manufacturing technologies for safety systems, the management of containment systems within laboratories and the awareness by users of the functional requirements that all containment systems must now have.  相似文献   

7.
The performance of class I and II microbiological safety cabinets over 7 years, employed in a force-ventilated containment level 3 (CL-3) laboratory, is described. Operator Protection (OP) provided by the cabinets, assessed by still and latterly limited 'in-use' KI-Discus tests, showed no overall deterioration during the review period. Comparisons show that a selected class II unit, but not a second, and a new class II MSC in a recently commissioned, similar CL-3 facility, provide the same order of OP as a class I cabinet. From the experiences described, it is strongly recommended that OP tests (OPTs) should be part of the routine servicing regime to ensure that cabinets meet required performance levels, and additionally to allow detection and rectification of poor containment, particularly where induced by environmental factors. The value of OPTs is discussed with reference to certain national standards.  相似文献   

8.
Aims: To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Methods and Results: Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high‐efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). Conclusions: This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Significance and Impact of the Study: Routine evaluation and maintenance of MSCs are critical for optimizing performance.  相似文献   

9.
The aerosol stability of two particle forms, infectious and potentially infectious, of reovirus were examined under static conditions for a range of relative humidities at 21 and 24 degrees C. Virus aerosolization efficiency was determined for two methods of dissemination: Collison nebulizer and Chicago atomizer. Suspensions of Bacillus subtilis var. niger spores were added to reovirus preparations that included both particle forms and disseminated into a dynamic aerosol toroid to estimate the physical decay of the aerosols. At 90 to 100% relative humidity, both reovirus particle forms showed less than 10-fold loss of infectivity after 12 h of aging. At lower relative humidities the aerosol decay curve showed rapid initial decay followed by a markedly lower decay rate. Our findings reveal that reovirus particles are relatively stable in the airborne state.  相似文献   

10.
A biological safety cabinet modified for bedding disposal was tested to determine the cabinet's ability to protect operators and experiments from aerosol exposure during routine microbiological and cage cleaning procedures. Stringent test conditions were provided by modifications of standardized protocols in addition to simulated cage dumping procedures, both of which utilized bacterial aerosols as challenges. Results of standardized test procedures (with no operator present) indicated good performance in protecting both operators and experiments. Procedures involving the dumping (by an operator) of contaminated bedding within the unit showed that the cabinet was able to contain 99.96% or greater of the total particles generated.  相似文献   

11.
Schlieren photography has been used to visualize the airflows in and around three re-circulating linear downflow cabinets. The results show that there is an air 'bulge' at the front opening that allows air from within the cabinet to spill out towards the operator. Hand movements within, and activity just outside, cause air to be expelled from these cabinets. Bunsen burners within the cabinets destroy the linear nature of the downflowing air streams. The results indicate that the operator protection afforded by these cabinets may be much less than is generally recognized.  相似文献   

12.
《MABS-AUSTIN》2013,5(5):1347-1355
Most monoclonal antibodies (mAbs) are administered to patients intravenously to ensure high bioavailability as rapidly as possible. The airways, however, are an attractive delivery route for mAbs for the treatment of lung diseases, making it possible to increase their concentration in the target organ while limiting their systemic passage. Several challenges must be overcome for translation into clinical practice. For example, the drug and device must be paired for the efficient and reliable deposition of a pharmacologically active and safe mAb in the lung region of interest. Mesh nebulizers appear to be the most effective aerosol-producing devices for delivering large amounts of biopharmaceutical while limiting protein instability during nebulization. We used metrological and analytic methods to analyze the effect of both antibody concentration and surfactant addition on aerosol performance and antibody integrity. These two factors had a limited effect on aerosol performance, but affected antibody aggregation. The addition of surfactants to antibody formulations at concentrations appropriate for lung administration markedly reduced the formation of medium or large aggregates, as shown by dynamic light scattering and fluorescence microscopy. Aggregation was also dependent on the type of mesh nebulizer, highlighting the need to optimize drug and device together.  相似文献   

13.
Most monoclonal antibodies (mAbs) are administered to patients intravenously to ensure high bioavailability as rapidly as possible. The airways, however, are an attractive delivery route for mAbs for the treatment of lung diseases, making it possible to increase their concentration in the target organ while limiting their systemic passage. Several challenges must be overcome for translation into clinical practice. For example, the drug and device must be paired for the efficient and reliable deposition of a pharmacologically active and safe mAb in the lung region of interest. Mesh nebulizers appear to be the most effective aerosol-producing devices for delivering large amounts of biopharmaceutical while limiting protein instability during nebulization. We used metrological and analytic methods to analyze the effect of both antibody concentration and surfactant addition on aerosol performance and antibody integrity. These two factors had a limited effect on aerosol performance, but affected antibody aggregation. The addition of surfactants to antibody formulations at concentrations appropriate for lung administration markedly reduced the formation of medium or large aggregates, as shown by dynamic light scattering and fluorescence microscopy. Aggregation was also dependent on the type of mesh nebulizer, highlighting the need to optimize drug and device together.  相似文献   

14.
This study aimed to provide data on the survival and site of damage of Escherichia coli cells following aerosolization using two different techniques, nebulization and flow focusing. Four metabolic stains were assessed for their ability to detect respiratory activities and membrane homeostasis in aerosolized E. coli cells. The degree of sublethal injury increased significantly over the 10-min period of aerosolization in E. coli cells aerosolized by using the Collison nebulizer, reaching up to 99.9% of the population. In contrast, a significantly lower proportion of the population was sublethally damaged during aerosolization using the flow-focusing aerosol generator (FFAG). Concomitantly, loss of membrane homeostasis increased at a higher rate in nebulized cells (68 to 71%) than in those aerosolized by using the FFAG (32 to 34%). The activities of respiratory enzymes decreased at increased rates in nebulized cells (27 to 37%) compared to the rates of decrease in cells aerosolized by using the FFAG (59 to 61%). The results indicate that the physiology of an aerosolized bacterium is linked to the method of aerosol generation and may affect the interpretation of a range of aerobiological phenomenon.  相似文献   

15.
Cryptococcus is an emerging global health threat that is annually responsible for over 1,000,000 infections and one third of all AIDS patient deaths. There is an ongoing outbreak of cryptococcosis in the western United States and Canada. Cryptococcosis is a disease resulting from the inhalation of the infectious propagules from the environment. The current and most frequently used animal infection models initiate infection via liquid suspension through intranasal instillation or intravenous injection. These models do not replicate the typically dry nature of aerosol exposure and may hinder our ability to decipher the initial events that lead to clearance or the establishment of infection. We have established a standardized aerosol model of murine infection for the human fungal pathogen Cryptococcus. Aerosolized cells were generated utilizing a Collison nebulizer in a whole-body Madison Chamber at different humidity conditions. The aerosols inside the chamber were sampled using a BioSampler to determine viable aerosol concentration and spray factor (ratio of viable aerosol concentration to total inoculum concentration). We have effectively delivered yeast and yeast-spore mixtures to the lungs of mice and observed the establishment of disease. We observed that growth conditions prior to exposure and humidity within the Madison Chamber during exposure can alter Cryptococcus survival and dose retained in mice.  相似文献   

16.
Microbes in food processing technology   总被引:4,自引:0,他引:4  
Abstract: There is an increasing understanding that the microbial quality of a certain food is the result of a chain of events. It is clear that the microbial safety of food can only be guaranteed when the overall processing, including the production of raw materials, distribution and handling by the consumer are taken into consideration. Therefore, the microbiological quality assurance of foods is not only a matter of control, but also of a careful design of the total process chain. Food industry has now generally adapted quality assurance systems and is implementing the Hazard Analysis Critical Control Point (HACCP) concept. Rapid microbiological monitoring systems should be used in these cases. There is a need for rapid and simple microbiological tests which can be adapted to the technology and logistics of specific production processes. Traditional microbiological methods generally do not meet these high requirements. This paper discusses the tests, based on molecular biological principles, to detect and identify microbes in food-processing chains. Tests based on DNA technology are discussed, including in vitro DNA amplification like the polymerase chain reaction (PCR) method and identifications based on RFLP, RAPD and DNA fingerprinting analysis. PCR-haled methodology can be used for the rapid detection of microbes in food manufacturing environments. In addition, DNA fingerprinting methods are suitable for investigating sources and routes of microbial contamination in the food cycle.  相似文献   

17.
Effect of relative humidity on the airborne survival of rhinovirus-14   总被引:5,自引:0,他引:5  
Rhinovirus-14, suspended in tryptose phosphate broth supplemented with uranine (physical tracer) and an antifoam, was aerosolized by use of a Collison nebulizer. The aerosols were held in a rotating drum with the relative humidity at either the low (30 +/- 5%), medium (50 +/- 5%), or high (80 +/- 5%) level at 20 +/- 1 degrees C. An all-glass impinger was used to recover the virus from the air in the drum, with the first air sample being collected after a 15-min period of aerosol stabilization. Subsequent air samples were withdrawn at 2, 4, 8, and 14 h after stabilization of the aerosol. At the low and medium relative humidity levels, the infectivity of the airborne virus was rapidly lost and less than 0.25% could be detected in the first air sample. At the high RH level, however, the airborne virus had a half-life of 13.7 +/- 1.91 h and nearly 30% of the input infectious virus could be detected in the drum air even after 24 h of aerosolization. These findings suggest that under certain environmental conditions, notably high relative humidity, air may act as a vehicle for the spread of rhinovirus infections.  相似文献   

18.
Flow-focussing technology was harnessed to enable generation of large droplet aerosols within high-level microbiological containment. The Collison nebuliser and flow-focussing aerosol generator (FFAG) produced aerosols from distilled water with average mass median aerodynamic diameters (MMAD) of 4.19 and 11.93 μm, respectively. The medium type [water, phosphate buffered saline (PBS) or microbiological broth] had minimal effect on the droplet size generated by the FFAG. The FFAG can be modulated to generate reproducible aerosols with a wide range of MMADs (9–105 μm). The number of particulates (i.e. fluospheres) contained within the droplets increased as the MMAD increased from 12 to 50 μm. The technology described can be used for the exposure of small-animal models to large droplet aerosols (>10 μm) and has applications in healthcare, pharmaceutical, agricultural and biodefence environments.  相似文献   

19.
Laser diffraction (LD) and next generation impactor (NGI) are commonly used for the evaluation of inhaled drug formulations. In this study, the effect of temperature and humidity on the assessment of the nebulizer particle size distribution (PSD) by LD was investigated, and the consistency between NGI and LD measurements was evaluated. There was an increase in particle size with higher temperature or lower humidity. The particle population with a diameter less than 1 μm was significant at a temperature of 5°C or at relative humidity >90%; however, the same particle population became undetectable when temperature increased to 39°C or at relative humidity of 30–45%. The results of the NGI and LD measurements of aerosol generated from three types of jet nebulizers were compared. A poor correlation between the NGI and LD measurements was observed for PARI LC (2.2 μm) (R 2?=?0.893) and PARI LC (2.9 μm) (R 2?=?0.878), while a relatively good correlation (R 2?=?0.977) was observed for the largest particle size nebulizer (PARI TIA (8.6 μm)). We conclude that the ambient environment and the nebulizer have significant impacts on the performance and consistency between these instruments. These factors should be controlled in the evaluation of inhaled aerosol drug formulations when these instruments are used individually or in combination.  相似文献   

20.
Rotavirus SA11, suspended in tryptose phosphate broth with 2.5 mg of rhodamine B per ml, was aerosolized (Collison nebulizer) into a rotating drum, and the aerosols were held at 20 +/- 1 degree C with the desired relative humidity (RH). An all-glass impinger with tryptose phosphate broth was used to collect 1-min (5.6-liter) samples of air from the drum. The virus was found to survive best at medium (50 +/- 5%) RH, where its half-life was nearly 40 h. The half-life of the virus at the low (25 +/- 5%) RH level was about 9 h. Even at 72 h of aerosol age, 45 and 21% of the infectious virus remained detectable in the air at the medium and low RH levels, respectively. The high (80 +/- 5%) RH level was found to be the least favorable to the survival of the virus, since 50% of the infectious virus became undetectable within 2 h of aerosolization. In a separate experiment at the midrange RH, 3% of the infectious virus was detectable in the drum air after 223 h (9 days) of aerosol age. Rotaviruses could, therefore, survive in air for prolonged periods, thus making air a possible vehicle for their dissemination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号