Complications in the patellofemoral (PF) joint of patients with total knee replacements include patellar subluxation and dislocation, and remain a cause for revision. Kinematic measurements to assess these complications and evaluate implant designs require the accuracy of dynamic stereo-radiographic systems with 3D-2D registration techniques. While tibiofemoral kinematics are typically derived by tracking metallic implants, PF kinematic measurements are difficult as the patellar implant is radiotransparent and a representation of the resected patella bone requires either pre-surgical imaging and precise implant placement or post-surgical imaging. Statistical shape models (SSMs), used to characterize anatomic variation, provide an alternative means to obtain the representation of the resected patella for use in kinematic tracking. Using a virtual platform of a stereo-radiographic system, the objectives of this study were to evaluate the ability of an SSM to predict subject-specific 3D implanted patellar geometries from simulated 2D image profiles, and to formulate an effective data collection methodology for PF kinematics by considering accuracy for a variety of patient pose scenarios. An SSM of the patella was developed for 50 subjects and a leave-one-out approach compared SSM-predicted and actual geometries; average 3D errors were 0.45 ± 0.07 mm (mean ± standard deviation), which is comparable to the accuracy of traditional segmentation. Further, initial imaging of the patella in five unique stereo radiographic perspectives yielded the most accurate representation. The ability to predict the remaining patellar geometry of the implanted PF joint with radiographic images and SSM, instead of CT, can reduce radiation exposure and streamline in vivo kinematic evaluations.  相似文献   

2.
The iliotibial band (ITB) has an important role in knee mechanics and tightness can cause patellofemoral maltracking. This study investigated the effects of increasing ITB tension on knee kinematics. Nine fresh-frozen cadaveric knees had the components of the quadriceps loaded with 175 N. A Polaris optical tracking system was used to acquire joint kinematics during extension from 100° to 0° flexion. This was repeated after the following ITB loads: 30, 60 and 90 N. There was no change with 30 N load for patellar translation. On average, at 60 and 90 N, the patella translated laterally by 0.8 and 1.4 mm in the mid flexion range compared to the ITB unloaded condition. The patella became more laterally tilted with increasing ITB loads by 0.7°, 1.2° and 1.5° for 30, 60 and 90 N, respectively. There were comparable increases in patellar lateral rotation (distal patella moves laterally) towards the end of the flexion cycle. Increased external rotation of the tibia occurred from early flexion onwards and was maximal between 60° and 75° flexion. The increase was 5.2°, 9.5° and 13° in this range for 30, 60 and 90 N, respectively. Increased tibial abduction with ITB loads was not observed. The combination of increased patellar lateral translation and tilt suggests increased lateral cartilage pressure. Additionally, the increased tibial external rotation would increase the Q angle. The clinical consequences and their relationship to lateral retinacular releases may be examined, now that the effects of a tight ITB are known.  相似文献   

3.
Quantifying the mechanical environment at the knee is crucial for developing successful rehabilitation and surgical protocols. Computational models have been developed to complement in vitro studies, but are typically created to represent healthy conditions, and may not be useful in modeling pathology and repair. Thus, the objective of this study was to create finite element (FE) models of the natural knee, including specimen-specific tibiofemoral (TF) and patellofemoral (PF) soft tissue structures, and to evaluate joint mechanics in intact and ACL-deficient conditions. Simulated gait in a whole joint knee simulator was performed on two cadaveric specimens in an intact state and subsequently repeated following ACL resection. Simulated gait was performed using motor-actuated quadriceps, and loads at the hip and ankle. Specimen-specific FE models of these experiments were developed in both intact and ACL-deficient states. Model simulations compared kinematics and loading of the experimental TF and PF joints, with average RMS differences [max] of 3.0° [8.2°] and 2.1° [8.4°] in rotations, and 1.7 [3.0] and 2.5 [5.1] mm in translations, for intact and ACL-deficient states, respectively. The timing of peak quadriceps force during stance and swing phase of gait was accurately replicated within 2° of knee flexion and with an average error of 16.7% across specimens and pathology. Ligament recruitment patterns were unique in each specimen; recruitment variability was likely influenced by variations in ligament attachment locations. ACL resections demonstrated contrasting joint mechanics in the two specimens with altered knee motion shown in one specimen (up to 5 mm anterior tibial translation) while increased TF joint loading was shown in the other (up to 400 N).  相似文献   

4.
Diagnosing dysfunctional atlantoaxial motion is challenging given limitations of current diagnostic imaging techniques. Three-dimensional imaging during upright functional motion may be useful in identifying dynamic instability not apparent on static imaging. Abnormal atlantoaxial motion has been linked to numerous pathologies including whiplash, cervicogenic headaches, C2 fractures, and rheumatoid arthritis. However, normal C1/C2 rotational kinematics under dynamic physiologic loading have not been previously reported owing to imaging difficulties. The objective of this study was to determine dynamic three-dimensional in vivo C1/C2 kinematics during upright axial rotation. Twenty young healthy adults performed full head rotation while seated within a biplane X-ray system while radiographs were collected at 30 images per second. Six degree-of-freedom kinematics were determined for C1 and C2 via a validated volumetric model-based tracking process. The maximum global head rotation (to one side) was 73.6 ± 8.3°, whereas maximum C1 rotation relative to C2 was 36.8 ± 6.7°. The relationship between C1/C2 rotation and head rotation was linear through midrange motion (±20° head rotation from neutral) in a nearly 1:1 ratio. Coupled rotation between C1 and C2 included 4.5 ± 3.1° of flexion and 6.4 ± 8.2° of extension, and 9.8 ± 3.8° of contralateral bending. Translational motion of C1 relative to C2 was 7.8 ± 1.5 mm ipsilaterally, 2.2 ± 1.2 mm inferiorly, and 3.3 ± 1.0 mm posteriorly. We believe this is the first study describing 3D dynamic atlantoaxial kinematics under true physiologic conditions in healthy subjects. C1/C2 rotation accounts for approximately half of total head axial rotation. Additionally, C1 undergoes coupled flexion/extension and contralateral bending, in addition to inferior, lateral and posterior translation.  相似文献   

5.
Numerous techniques have been employed to monitor humeral head translation due to its involvement with several shoulder pathologies. However, most of the techniques were not validated. The objective of this study is to compare the accuracy of manual digitization and contour registration in measuring superior translation of the humeral head. Eight pairs of cadaver scapulae and humerii bones were harvested for this study. Each scapula and humerus was secured in a customized jig that allowed for control of humeral head translations and a vise that permitted rotations of the scapula about three axes. Fluoroscopy was used to take images of the shoulder bones. Scapular orientation was manipulated in different positions while the humerus was at 90° of humeral elevation in the scapular plane. Humeral head translation was measured using the two methods and was compared to the known translation. Additionally, accuracy of the contour registration method to measure 2-D scapular rotations was assessed. The range for the root mean square (RMS) error for manual digitization method was 0.27 mm - 0.43 mm and the contour registration method had a RMS error ranging from 0.18 mm - 0.40 mm. In addition, the RMS error for the scapular angle rotation using the contour registration method was 2.4°. Both methods showed acceptable errors. However, on average, the contour registration method showed lesser measurement error compared to the manual digitization method. In addition, the contour registration method was able to show good accuracy in measuring rotation that is useful in 2-D image analysis.  相似文献   

6.
The aim of this study was to quantify the tibio-femoral contact point (CP) locations in healthy and osteoarthritic (OA) subjects during a weight-bearing squat using stand-alone biplanar X-ray images.Ten healthy and 9 severe OA subjects performed quasi-static squats. Bi-planar X-ray images were recorded at 0°, 15°, 30°, 45°, and 70° of knee flexion. A reconstruction/registration process was used to create 3D models of tibia, fibula, and femur from bi-planar X-rays and to measure their positions at each posture. A weighted centroid of proximity algorithm was used to calculate the tibio-femoral CP locations. The accuracy of the reconstruction/registration process in measuring the quasi-static kinematics and the contact parameters was evaluated in a validation study.The quasi-static kinematics data revealed that in OA knees, adduction angles were greater (p<0.01), and the femur was located more medially relative to the tibia (p<0.01). Similarly, the average CP locations on the medial and lateral tibial plateaus of the OA patients were shifted (6.5±0.7 mm; p<0.01) and (9.6±3.1 mm; p<0.01) medially compared to the healthy group. From 0° to 70° flexion, CPs moved 8.1±5.3 mm and 8.9±5.3 mm posteriorly on the medial and lateral plateaus of healthy knees; while in OA joints CPs moved 10.1±8.4 mm and 3.6±2.8 mm posteriorly. The average minimum tibio-femoral bone-to-bone distances of the OA joints were lower in both compartments (p<0.01).The CPs in the OA joints were located more medially and displayed a higher ratio of medial to lateral posterior translations compared to healthy joints.  相似文献   

7.
Verified computational models represent an efficient method for studying the relationship between articular geometry, soft-tissue constraint, and patellofemoral (PF) mechanics. The current study was performed to evaluate an explicit finite element (FE) modeling approach for predicting PF kinematics in the natural and implanted knee. Experimental three-dimensional kinematic data were collected on four healthy cadaver specimens in their natural state and after total knee replacement in the Kansas knee simulator during a simulated deep knee bend activity. Specimen-specific FE models were created from medical images and CAD implant geometry, and included soft-tissue structures representing medial–lateral PF ligaments and the quadriceps tendon. Measured quadriceps loads and prescribed tibiofemoral kinematics were used to predict dynamic kinematics of an isolated PF joint between 10° and 110° femoral flexion. Model sensitivity analyses were performed to determine the effect of rigid or deformable patellar representations and perturbed PF ligament mechanical properties (pre-tension and stiffness) on model predictions and computational efficiency.Predicted PF kinematics from the deformable analyses showed average root mean square (RMS) differences for the natural and implanted states of less than 3.1° and 1.7 mm for all rotations and translations. Kinematic predictions with rigid bodies increased average RMS values slightly to 3.7° and 1.9 mm with a five-fold decrease in computational time. Two-fold increases and decreases in PF ligament initial strain and linear stiffness were found to most adversely affect kinematic predictions for flexion, internal–external tilt and inferior–superior translation in both natural and implanted states. The verified models could be used to further investigate the effects of component alignment or soft-tissue variability on natural and implant PF mechanics.  相似文献   

8.
This study aims to quantify and compare the accuracy of traditional radiostereometric analysis (RSA), fluoroscopic RSA (fRSA), and optical tracking systems. Three phantoms were constructed, each having three stainless steel spheres and three reflective markers. One phantom was mounted to the base of a precision cross-slide table, one to the base of a precision rotation table, and the third was mounted to each moveable tabletop. Two dial-gauges, rigidly mounted to the cross-slide table and rotation table, quantified translations and rotations. Two fluoroscopy units placed orthogonally tracked the steel spheres while a four-camera optical motion capture system tracked the reflective markers in three-dimensional space. RSA was performed with both digital radiography and fluoroscopy. Three axes of translation were tested: parallel to one fluoroscopy image, parallel to the other fluoroscopy image, and at approximately 45° to each image. One axis of rotation was tested. Intraclass correlation coefficients indicated excellent agreement between the actual (dial-gauge) and measured translations for all modalities (ICCs>0.99) and excellent agreement between actual and measured rotations for RSA and fRSA (ICCs>0.99). Standard errors of measurement ranged from 0.032 mm and 0.121° for RSA, to 0.040 mm and 0.229° for fRSA, and to 0.109 mm and 0.613° for optical tracking. Differences between actual and measured translations along the 45° axis were significantly smaller than the two parallel axes. These findings suggest that under ideal conditions, accuracy of fRSA is comparable to traditional RSA, and superior to optical tracking. Accuracy is highest when measured at 45° to the fluoroscopy units.  相似文献   

9.
Estimating joint kinematics from skin-marker trajectories recorded using stereophotogrammetry is complicated by soft tissue artefact (STA), an inexorable source of error. One solution is to use a bone pose estimator based on multi-body kinematics optimisation (MKO) embedding joint constraints to compensate for STA. However, there is some debate over the effectiveness of this method. The present study aimed to quantitatively assess the degree of agreement between reference (i.e., artefact-free) knee joint kinematics and the same kinematics estimated using MKO embedding six different knee joint models. The following motor tasks were assessed: level walking, hopping, cutting, running, sit-to-stand, and step-up. Reference knee kinematics was taken from pin-marker or biplane fluoroscopic data acquired concurrently with skin-marker data, made available by the respective authors. For each motor task, Bland-Altman analysis revealed that the performance of MKO varied according to the joint model used, with a wide discrepancy in results across degrees of freedom (DoFs), models and motor tasks (with a bias between −10.2° and 13.2° and between −10.2 mm and 7.2 mm, and with a confidence interval up to ±14.8° and ±11.1 mm, for rotation and displacement, respectively). It can be concluded that, while MKO might occasionally improve kinematics estimation, as implemented to date it does not represent a reliable solution to the STA issue.  相似文献   

10.
Soft tissue artefacts (STA) introduce errors in joint kinematics when using cutaneous markers, especially on the scapula. Both segmental optimisation and multibody kinematics optimisation (MKO) algorithms have been developed to improve kinematics estimates. MKO based on a chain model with joint constraints avoids apparent joint dislocation but is sensitive to the biofidelity of chosen joint constraints. Since no recommendation exists for the scapula, our objective was to determine the best models to accurately estimate its kinematics. One participant was equipped with skin markers and with an intracortical pin screwed in the scapula. Segmental optimisation and MKO for 24-chain models (including four variations of the scapulothoracic joint) were compared against the pin-derived kinematics using root mean square error (RMSE) on Cardan angles. Segmental optimisation led to an accurate scapula kinematics (1.1°  RMSE  3.3°) even for high arm elevation angles. When MKO was applied, no clinically significant difference was found between the different scapulothoracic models (0.9°  RMSE  4.1°) except when a free scapulothoracic joint was modelled (1.9°  RMSE  9.6°). To conclude, using MKO as a STA correction method was not more accurate than segmental optimisation for estimating scapula kinematics.  相似文献   

11.
Excessive knee joint laxity is often used as an indicator of joint disease or injury. Clinical assessment devices are currently limited to anterior–posterior drawer measurements, while tools used to measure movement in the remaining degrees of freedom are either invasive or prone to soft tissue artefact. The objective of this work was, therefore, to develop a methodology whereby in vivo knee joint kinematics could be measured in three dimensions under torsional loading while still maintaining a non-invasive procedure. A device designed to administer a subject-normalized torque in the transverse plane of the knee was securely fastened to the outer frame of an open magnetic resonance imaging (MRI) magnet. Low resolution 3D T1-weighted images (6.25 mm slice thickness) were generated by the 0.2 Tesla MRI scanner in less than 3 min while the joint was under load. The 3D image volume was then shape-matched to a high resolution image volume (1.56 mm slice thickness) scanned in a no-load position. Three-dimensional rotations and translations of the tibia with respect to the femur were calculated by comparing the transformation matrices before and after torque was applied. Results from six subjects showed that this technique was repeatable over five trials with the knee in extended and flexed positions. Differences in range of rotation were shown between subjects and between knee positions, suggesting that this methodology has sufficient utility for further application in clinical studies.  相似文献   

12.
Skin-mounted marker based motion capture systems are widely used in measuring the movement of human joints. Kinematic measurements associated with skin-mounted markers are subject to soft tissue artifacts (STA), since the markers follow skin movement, thus generating errors when used to represent motions of underlying bone segments. We present a novel ultrasound tracking system that is capable of directly measuring tibial and femoral bone surfaces during dynamic motions, and subsequently measuring six-degree-of-freedom (6-DOF) tibiofemoral kinematics. The aim of this study is to quantitatively compare the accuracy of tibiofemoral kinematics estimated by the ultrasound tracking system and by a conventional skin-mounted marker based motion capture system in a cadaveric experimental scenario. Two typical tibiofemoral joint models (spherical and hinge models) were used to derive relevant kinematic outcomes. Intra-cortical bone pins equipped with optical markers were inserted in the tibial and femoral bones to serve as a reference to provide ground truth kinematics. The ultrasound tracking system resulted in lower kinematic errors than the skin-mounted markers (the ultrasound tracking system: maximum root-mean-square (RMS) error 3.44° for rotations and 4.88 mm for translations, skin-mounted markers with the spherical joint model: 6.32° and 6.26 mm, the hinge model: 6.38° and 6.52 mm). Our proposed ultrasound tracking system has the potential of measuring direct bone kinematics, thereby mitigating the influence and propagation of STA. Consequently, this technique could be considered as an alternative method for measuring 6-DOF tibiofemoral kinematics, which may be adopted in gait analysis and clinical practice.  相似文献   

13.
To reduce the impact of the soft tissue artefact (STA) on the estimate of skeletal movement using stereophotogrammetric and skin-marker data, multi-body kinematics optimisation (MKO) and extended Kalman filters (EKF) have been proposed. This paper assessed the feasibility and efficiency of these methods when they embed a mathematical model of the STA and simultaneously estimate the ankle, knee and hip joint kinematics and the model parameters. A STA model was used that provides an estimate of the STA affecting the marker-cluster located on a body segment as a function of the kinematics of the adjacent joints. The MKO and the EKF were implemented with and without the STA model. To assess these methods, intra-cortical pin and skin markers located on the thigh, shank, and foot of three subjects and tracked during the stance phase of running were used. Embedding the STA model in MKO and EKF reduced the average RMS of marker tracking from 12.6 to 1.6 mm and from 4.3 to 1.9 mm, respectively, showing that a STA model trial-specific calibration is feasible. Nevertheless, with the STA model embedded in MKO, the RMS difference between the estimated and the reference joint kinematics determined from the pin markers slightly increased (from 2.0 to 2.1 deg) On the contrary, when the STA model was embedded in the EKF, this RMS difference was slightly reduced (from 2.0 to 1.7 deg) thus showing a better potentiality of this method to attenuate STA effects and improve the accuracy of joint kinematics estimate.  相似文献   

14.
PurposeThis multi-institution study assessed the positioning accuracy of multileaf collimators (MLC) by analyzing log files. It determined the main machine parameters that affect MLC positioning errors for pre-TrueBeam (Clinac) and TrueBeam linacs.MethodsAround 30,000 dIMRT and VMAT log files belonging to 6 linacs from 4 different centers were analyzed. An in-house software was used to calculate 95th percentile and RMS error values and their correlation with certain parameters such as maximum leaf speed, mean leaf speed and gantry angle. The effect of MLC communication delay on error statistics was assessed in Clinac linacs. To that end MLC positioning error statistics were calculated with and without the delay effect.ResultsFor dIMRT treatments in Clinac linacs the mean leaf RMS error was 0.306 mm with and 0.030 mm without the delay effect. Leaf RMS error was closely linked to maximum and mean leaf speeds, but without the delay effect that link was weaker. No trend was observed between bank RMS error and gantry angle. Without the delay effect larger bank RMS errors were obtained for gantry angles with leaf movements against gravity. For VMAT treatments in TrueBeam linacs the mean leaf RMS error was 0.038 mm. A link was also observed between leaf RMS error and maximum and mean leaf speeds.ConclusionTrueBeam MLC positioning errors are substantially lower than those of Clinac linacs. In Clinac machines the analysis of dynalogs without the delay effect allows us to study the influence of factors that are masked by the delay effect.  相似文献   

15.
Combination of biplane fluoroscopy and CT-scan provides accurate 3D measurement of the acromiohumeral distance (AHD) during dynamic tasks. However, participants performed only two and six trials in previous experiments to respect the recommended radiation exposure per year. Our objective was to propose a technique to assess the AHD in 3D during dynamic tasks without this limitation. The AHD was computed from glenohumeral kinematics obtained using markers fitted to pins drilled into the scapula and the humerus combined with 3D bone geometry obtained using CT-scan. Four participants performed range-of-motion, daily-living, and sports activities. Sixty-six out of 158 trials performed by each participant were analyzed. Two participants were not considered due to experimental issues. AHD decreased with arm elevation. Overall, the smallest AHD occurred in abduction (1.1 mm (P1) and 1.2 mm (P2)). The smallest AHD were 2.4 mm (P1) and 3.1 mm (P2) during ADL. It was 2.8 mm (P1) and 1.1 mm (P2) during sports activities. The humeral head greater and lesser tuberosities came the nearest to the acromion. The proposed technique increases the number of trials acquired during one experiment compared to previous. The identification of movements maximizing AHD is possible, which may provide benefits for shoulder rehabilitation.  相似文献   

16.
AimTo investigate tumour motion tracking uncertainties in the CyberKnife Synchrony system with single fiducial marker in liver tumours.BackgroundIn the fiducial-based CyberKnife real-time tumour motion tracking system, multiple fiducial markers are generally used to enable translation and rotation corrections during tracking. However, sometimes a single fiducial marker is employed when rotation corrections are not estimated during treatment.Materials and methodsData were analysed for 32 patients with liver tumours where one fiducial marker was implanted. Four-dimensional computed tomography (CT) scans were performed to determine the internal target volume (ITV). Before the first treatment fraction, the CT scans were repeated and the marker migration was determined. Log files generated by the Synchrony system were obtained after each treatment and the correlation model errors were calculated. Intra-fractional spine rotations were examined on the spine alignment images before and after each treatment.ResultsThe mean (standard deviation) ITV margin was 4.1 (2.3) mm, which correlated weakly with the distance between the fiducial marker and the tumour. The mean migration distance of the marker was 1.5 (0.7) mm. The overall mean correlation model error was 1.03 (0.37) mm in the radial direction. The overall mean spine rotations were 0.27° (0.31), 0.25° (0.22), and 0.23° (0.26) for roll, pitch, and yaw, respectively. The treatment time was moderately associated with the correlation model errors and weakly related to spine rotation in the roll and yaw planes.ConclusionsMore caution and an additional safety margins are required when tracking a single fiducial marker.  相似文献   

17.
The soft-tissue interface between skin-mounted markers and the underlying bones poses a major limitation to accurate, non-invasive measurement of joint kinematics. The aim of this study was twofold: first, to quantify lower limb soft-tissue artifact in young healthy subjects during functional activity; and second, to determine the effect of soft-tissue artifact on the calculation of knee joint kinematics. Subject-specific bone models generated from magnetic resonance imaging (MRI) were used in conjunction with X-ray images obtained from single-plane fluoroscopy to determine three-dimensional knee joint kinematics for four separate tasks: open-chain knee flexion, hip axial rotation, level walking, and a step-up. Knee joint kinematics was derived using the anatomical frames from the MRI-based, 3D bone models together with the data from video motion capture and X-ray fluoroscopy. Soft-tissue artifact was defined as the degree of movement of each marker in the anteroposterior, proximodistal and mediolateral directions of the corresponding anatomical frame. A number of different skin-marker clusters (total of 180) were used to calculate knee joint rotations, and the results were compared against those obtained from fluoroscopy. Although a consistent pattern of soft-tissue artifact was found for each task across all subjects, the magnitudes of soft-tissue artifact were subject-, task- and location-dependent. Soft-tissue artifact for the thigh markers was substantially greater than that for the shank markers. Markers positioned in the vicinity of the knee joint showed considerable movement, with root mean square errors as high as 29.3 mm. The maximum root mean square errors for calculating knee joint rotations occurred for the open-chain knee flexion task and were 24.3°, 17.8° and 14.5° for flexion, internal–external rotation and abduction–adduction, respectively. The present results on soft-tissue artifact, based on fluoroscopic measurements in healthy adult subjects, may be helpful in developing location- and direction-specific weighting factors for use in global optimization algorithms aimed at minimizing the effects of soft-tissue artifact on calculations of knee joint rotations.  相似文献   

18.
Scapular kinematics in healthy adults is well described in the literature but little is known on typical children. This study aimed to compare the three-dimensional (3-D) scapular kinematics and scapulohumeral rhythm during the elevation and lowering of the arm in the scapular plane in typical children and healthy adults. Twenty-six healthy adults (35.34 ± 11.65 years, 1.70 ± 0.10 m, 70.00 ± 12.30 kg) and 33 typical children (9.12 ± 1.51 years, 1.40 ± 0.10 m, 35.40 ± 10.45 kg) participated in this study. 3-D scapular kinematics were obtained using an electromagnetic tracking device. The subjects were asked to elevate and lower their arm in the scapular plane. Children showed less scapular protraction compared to adults at 120° during arm elevation, more anterior tilt than adults in the elevation and also at 60°, 90° and 120° during lowering of the arm. Children also showed higher scapulohumeral rhythm during lowering of the arm compared to adults from 90° to 60°. It was also found a low to little correlation between scapular position and age. The study showed small but significant differences in scapular kinematics and scapulohumeral rhythm between children and adults. These results can help clinicians to improve diagnosis and treatment protocols directed to children with dysfunction, as reference values on scapular kinematics in healthy children are also provided in this study.  相似文献   

19.
Rotator cuff (RC) tears may be associated with increased glenohumeral instability; however, this instability is difficult to quantify using currently available diagnostic tools. Recently, the three-dimensional (3D) reconstruction and registration method of the scapula and humeral head, based on sequences of low-dose biplane X-ray images, has been proposed for glenohumeral displacement assessment. This research aimed to evaluate the accuracy and reproducibility of this technique and to investigate its potential with a preliminary application comparing RC tear patients and asymptomatic volunteers. Accuracy was assessed using CT scan model registration on biplane X-ray images for five cadaveric shoulder specimens and showed differences ranging from 0.6 to 1.4 mm depending on the direction of interest. Intra- and interobserver reproducibility was assessed through two operators who repeated the reconstruction of five subjects three times, allowing defining 95% confidence interval ranging from ±1.8 to ±3.6 mm. Intraclass correlation coefficient varied between 0.84 and 0.98. Comparison between RC tear patients and asymptomatic volunteers showed differences of glenohumeral displacements, especially in the superoinferior direction when shoulder was abducted at 20° and 45°. This study thus assessed the accuracy of the low-dose 3D biplane X-ray reconstruction technique for glenohumeral displacement assessment and showed potential in biomechanical and clinical research.  相似文献   

20.
Optical motion capture is commonly used in biomechanics to measure human kinematics. However, no studies have yet examined the accuracy of optical motion capture in a large capture volume (>100 m3), or how accuracy varies from the center to the extreme edges of the capture volume. This study measured the dynamic 3D errors of an optical motion capture system composed of 42 OptiTrack Prime 41 cameras (capture volume of 135 m3) by comparing the motion of a single marker to the motion reported by a ThorLabs linear motion stage. After spline interpolating the data, it was found that 97% of the capture area had error below 200 μm. When the same analysis was performed using only half (21) of the cameras, 91% of the capture area was below 200 μm of error. The only locations that exceeded this threshold were at the extreme edges of the capture area, and no location had a mean error exceeding 1 mm. When measuring human kinematics with skin-mounted markers, uncertainty of marker placement relative to underlying skeletal features and soft tissue artifact produce errors that are orders of magnitude larger than the errors attributed to the camera system itself. Therefore, the accuracy of this OptiTrack optical motion capture system was found to be more than sufficient for measuring full-body human kinematics with skin-mounted markers in a large capture volume (>100 m3).  相似文献   