共查询到20条相似文献,搜索用时 0 毫秒
1.
PurposeIt is unclear that spatial accuracy can reflect the impact of deformed dose distribution. In this study, we used dosimetric parameters to compare an in-house deformable image registration (DIR) system using NiftyReg, with two commercially available systems, MIM Maestro (MIM) and Velocity AI (Velocity).MethodsFor 19 non-small-cell lung cancer patients, the peak inspiration (0%)-4DCT images were deformed to the peak expiration (50%)-4DCT images using each of the three DIR systems, which included computation of the deformation vector fields (DVF). The 0%-gross tumor volume (GTV) and the 0%-dose distribution were also then deformed using the DVFs. The agreement in the dose distributions for the GTVs was evaluated using generalized equivalent uniform dose (gEUD), mean dose (Dmean), and three-dimensional (3D) gamma index (criteria: 3 mm/3%). Additionally, a Dice similarity coefficient (DSC) was used to measure the similarity of the GTV volumes.ResultsDmean and gEUD demonstrated good agreement between the original and deformed dose distributions (differences were generally less than 3%) in 17 of the patients. In two other patients, the Velocity system resulted in differences in gEUD of 50.1% and 29.7% and in Dmean of 11.8% and 4.78%. The gamma index comparison showed statistically significant differences for the in-house DIR vs. MIM, and MIM vs. Velocity.ConclusionsThe finely tuned in-house DIR system could achieve similar spatial and dose accuracy to the commercial systems. Care must be taken, as we found errors of more than 5% for Dmean and 30% for gEUD, even with a commercially available DIR tool. 相似文献
2.
We evaluate the non-linear characteristics of the human lung via image registration-derived local variables based on volumetric multi-detector-row computed tomographic (MDCT) lung image data of six normal human subjects acquired at three inflation levels: 20% of vital capacity (VC), 60% VC and 80% VC. Local variables include Jacobian (ratio of volume change) and maximum shear strain for assessment of lung deformation, and air volume change for assessment of air distribution. First, the variables linearly interpolated between 20% and 80% VC images to reflect deformation from 20% to 60% VC are compared with those of direct registration of 20% and 60% VC images. The result shows that the linearly-interpolated variables agree only qualitatively with those of registration (P<0.05). Then, a quadratic (or linear) interpolation is introduced to link local variables to global air volumes of three images (or 20% and 80% VC images). A sinusoidal breathing waveform is assumed for assessing the time rate of change of these variables. The results show significant differences between two-image and three-image results (P<0.05). The three-image results for the whole lung indicate that the peak of the maximum shear rate occurs at about 37% of the maximum volume difference between 20% and 80% VC, while the peaks for the Jacobian and flow rate occur at 50%. This is in agreement with accepted physiology whereby lung tissues deform more at lower lung volumes due to lower elasticity and greater compliance. Furthermore, the three-image results show that the upper and middle lobes, even in the recumbent, supine posture, reach full expansion earlier than the lower lobes. 相似文献
3.
PurposeTo evaluate the respiratory motion of adrenal gland metastases in three-dimensional directions using four-dimensional computed tomography (4DCT) images.MethodsFrom January 2013 to May 2016, 12 patients with adrenal gland metastases were included in this study. They all underwent 4DCT scans to assess respiratory motion of adrenal gland metastases in free breathing state. The 4DCT images were sorted into 10 image series according to the respiratory phase from the end inspiration to the end expiration, and then transferred to FocalSim workstation. All gross tumor volumes (GTVs) of adrenal gland metastases were drawn by a single physician and confirmed by a second. Relative coordinates of adrenal gland metastases were automatically generated to calculate adrenal gland metastases motion in different axial directions.ResultsThe average respiratory motion of adrenal gland metastases in left-right (LR), cranial-caudal (CC), anterior-posterior (AP), 3-dimensional (3D) vector directions was 3.4 ± 2.2 mm, 9.5 ± 5.5 mm, 3.8 ± 2.0 mm and 11.3 ± 5.3 mm, respectively. The ratios were 58.6% ± 11.4% and 63.2% ± 12.5% when the volumes of GTVIn0% and GTV In100% were compared with volume of IGTV10phase. The volume ratio of IGTV10phase to GTV3D was 1.73 ± 0.48.ConclusionsAdrenal gland metastasis is a respiration-induced moving target, and an internal target volume boundary should be provided when designing the treatment plan. The CC motion of adrenal gland metastasis is predominant and >5 mm, thus motion management strategies are recommended for patients undergoing external radiotherapy for adrenal gland metastasis. 相似文献
4.
In proton therapy, the knowledge of the proton stopping power, i.e. the energy deposition per unit length within human tissue, is essential for accurate treatment planning. One suitable method to directly measure the stopping power is proton computed tomography (pCT). Due to the proton interaction mechanisms in matter, pCT image reconstruction faces some challenges: the unique path of each proton has to be considered separately in the reconstruction process adding complexity to the reconstruction problem. This study shows that the GPU-based open-source software toolkit TIGRE, which was initially intended for X-ray CT reconstruction, can be applied to the pCT image reconstruction problem using a straight line approach for the proton path. This simplified approach allows for reconstructions within seconds.To validate the applicability of TIGRE to pCT, several Monte Carlo simulations modeling a pCT setup with two Catphan® modules as phantoms were performed. Ordered-Subset Simultaneous Algebraic Reconstruction Technique (OS-SART) and Adaptive-Steepest-Descent Projection Onto Convex Sets (ASD-POCS) were used for image reconstruction. Since the accuracy of the approach is limited by the straight line approximation of the proton path, requirements for further improvement of TIGRE for pCT are addressed. 相似文献
5.
《Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)》2016,32(12):1628-1633
Purpose: Nowadays, patient positioning and target localization can be verified by using kilovolt cone beam computed tomography (kV-CBCT). There have been various studies on the absorbed doses and image qualities of different kV-CBCT systems. However, the Varian TrueBeam CBCT (TB CBCT) system has not been investigated so far. We assess the image quality and absorbed dose of TB CBCT through comparison with those of on-board imager (OBI) CBCT.Methods: The image quality was evaluated using two phantoms. A CATPHAN phantom measured the image quality parameters of the American Association of Physicists in Medicine Task Group 142 (AAPM TG-142) report. These factors are the pixel value stability and accuracy, noise, high-contrast resolution, low-contrast resolution, and image uniformity. A H2SO4 phantom was used to evaluate the image uniformity over a larger region than the CATPHAN phantom. In evaluating the absorbed dose, the radial dose profile and the patient organ doses at the prostate and rectum levels were evaluated.Results: The image quality parameters of AAPM TG-142 using TB CBCT are equal to or greater than those of OBI CBCT. In particular, the contrast-to-noise ratio with TB CBCT is 2.5 times higher than that with OBI CBCT. For the test of a large field uniformity, the maximum difference in the Hounsfield unit (HU) values between the centre and peripheral regions is within 30 HU with TB CBCT and 283 HU with OBI CBCT. The maximum absorbed dose with TB CBCT is decreased by 60%.Conclusions: We find that the image quality improved and the absorbed dose decreased with TB CBCT in comparison to those with OBI CBCT. Its image uniformity is also superior over a larger scanning range. 相似文献
6.
7.
To study temporal resolved computed tomography imaging (4-Dimensional Computed Tomography: 4DCT) artifacts correlations with scanning parameters and target kinetics and to assess uncertainty introduced by 4DCT in radiotherapy treatment planning.In this work we classified 4DCT artifacts as finite gantry rotation speed related (FGS) and finite sampling frequency related (FSF). We studied FGS artifacts using a respiratory phantom and FSF artifacts using a Monte Carlo simulation of acquisition timing.From our analysis FGS localization error is comparable with image resolution determined by voxel dimensions. Remaining FGS artifacts are correlated with gantry rotation time (Trot), target velocity (v) and their interaction.FSF artifacts occurrence is correlated with sampling ratio (SR), i.e. the ratio of patient respiratory period (Tresp) and sampling time (Ts).In the studied velocity range (0–2 cm/s), using a Trot of 0,5s and a SR higher than 15, FGS and FSF artifacts became comparable with other sources of uncertainty.Our considerations are valid for “ideal” breathing pattern only. When variations from periodical breathing, high target velocity (more than 2 cm/s) or high peak to peak amplitude (more than 2 cm) are present, patient specific images artifacts analysis is recommended. 相似文献
8.
PurposeThe aim of this study is to present a short and comprehensive review of the methods of medical image registration, their conditions and applications in radiotherapy. A particular focus was placed on the methods of deformable image registration.MethodsTo structure and deepen the knowledge on medical image registration in radiotherapy, a medical literature analysis was made using the Google Scholar browser and the medical database of the PubMed library.ResultsChronological review of image registration methods in radiotherapy based on 34 selected articles. A particular attention was given to show: (i) potential regions of the application of different methods of registration, (ii) mathematical basis of the deformable methods and (iii) the methods of quality control for the registration process.ConclusionsThe primary aim of the medical image registration process is to connect the contents of images. What we want to achieve is a complementary or extended knowledge that can be used for more precise localisation of pathogenic lesions and continuous improvement of patient treatment. Therefore, the choice of imaging mode is dependent on the type of clinical study. It is impossible to visualise all anatomical details or functional changes using a single modality machine. Therefore, fusion of various modality images is of great clinical relevance. A natural problem in analysing the fusion of medical images is geographical errors related to displacement. The registered images are performed not at the same time and, very often, at different respiratory phases. 相似文献
9.
10.
Purpose: To reduce image artifacts of proton computed tomography (pCT) from a preclinical scanner, for imaging of the relative stopping power (RSP) needed for particle therapy treatment planning using a simple empirical artifact correction method.Methods: We adapted and employed a correction method previously used for beam-hardening correction in x-ray CT which makes use of a single scan of a custom-built homogeneous phantom with known RSP. Exploiting the linearity of the filtered backprojection operation, a function was found which corrects water-equivalent path lengths (RSP line integrals) in experimental scans using a prototype pCT scanner. The correction function was applied to projection values of subsequent scans of a homogeneous water phantom, a sensitometric phantom with various inserts and an anthropomorphic head phantom. Data were acquired at two different incident proton energies to test the robustness of the method.Results: Inaccuracies in the detection process caused an offset and known ring artifacts in the water phantom which were considerably reduced using the proposed method. The mean absolute percentage error (MAPE) of mean RSP values of all inserts of the sensitometric phantom and the water phantom was reduced from 0.87% to 0.44% and from 0.86% to 0.48% for the two incident energies respectively. In the head phantom a clear reduction of artifacts was observed.Conclusions: Image artifacts of experimental pCT scans with a prototype scanner could substantially be reduced both in homogeneous, heterogeneous and anthropomorphic phantoms. RSP accuracy was also improved. 相似文献
11.
12.
Pollyana Marques Moura Gilson Giraldi Pedro Henrique Lira Diego Augusto Quadrado Leite Paulo Sérgio Silva Rodrigues Marcelo Faria 《Computer methods in biomechanics and biomedical engineering》2013,16(12):1089-1095
Objectives: The accuracy of cone-beam technique, cone-beam computed tomography (CBCT), compared with that of the multislice spiral CT (MSCT), for image-based linear measurements of midpalatal suture was assessed. Material and Methods: Two measurements were performed by one investigator on the dry skull by using one digital caliper and in the axial cuts by using software. A 2D object-based image registration process was applied to determine the best affine transformation that maps a 2D input image (CBCT) in a reference image (MSCT). Results: The value of the intraclass correlation coefficient was approximately 0.9%. The results suggest that differences between two scanners did not exist (observation 1, p = 0.964 and observation 2, p = 0.795). With regard to the dry skull and the image, the significance probabilities equaled zero (observation 1, p = 0.002 and observation 2, p = 0.004), therefore, indicating significant differences. Conclusion: Measurements acquired in the images were similar and these findings contribute to stimulate the use of CBCT for evaluation of the maxillary expansion procedure. 相似文献
13.
Sherif Gonem Alys Scadding Marcia Soares Amisha Singapuri Per Gustafsson Chandra Ohri Simon Range Christopher E Brightling Ian Pavord Alex Horsley Salman Siddiqui 《Respiratory research》2014,15(1):59
Background
Lung clearance index (LCI) is a measure of abnormal ventilation distribution derived from the multiple breath inert gas washout (MBW) technique. We aimed to determine the clinical utility of LCI in non-CF bronchiectasis, and to assess two novel MBW parameters that distinguish between increases in LCI due to specific ventilation inequality (LCIvent) and increased respiratory dead space (LCIds).Methods
Forty-three patients with non-CF bronchiectasis and 18 healthy control subjects underwent MBW using the sulphur hexafluoride wash-in technique, and data from 40 adults with CF were re-analysed. LCIvent and LCIds were calculated using a theoretical two-compartment lung model, and represent the proportional increase in LCI above its ideal value due to specific ventilation inequality and increased respiratory dead space, respectively.Results
LCI was significantly raised in patients with non-CF bronchiectasis compared to healthy controls (9.99 versus 7.28, p < 0.01), and discriminated well between these two groups (area under receiver operating curve = 0.90, versus 0.83 for forced expiratory volume in one second [% predicted]). LCI, LCIvent and LCIds were repeatable (intraclass correlation coefficient > 0.75), and correlated significantly with measures of spirometric airflow obstruction.Conclusion
LCI is repeatable, discriminatory, and is associated with spirometric airflow obstruction in patients with non-CF bronchiectasis. LCIvent and LCIds are a practical and repeatable alternative to phase III slope analysis and may allow a further level of mechanistic information to be extracted from the MBW test in patients with severe ventilation heterogeneity. 相似文献14.
《Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)》2016,32(12):1575-1583
ObjectiveTo evaluate the effect of cone-beam computed tomography (CBCT) image acquisition protocols on image quality, lesion detection, delineation, and patient dose.Methods100-patients and a CTDI phantom combined with an electron density phantom were examined using four different CBCT-image acquisition protocols during image-guided transarterial chemoembolization (TACE). Protocol-1 (time: 6 s, tube rotation: 360°), protocol-2 (5 s, 300°), protocol-3 (4 s, 240°) and protocol-4 (3 s, 180°) were used. The protocols were first investigated using a phantom. The protocols that were found to be clinically appropriate in terms of image quality and radiation dose were then assessed on patients. A higher radiation dose and/or a poor image quality were inappropriate for the patient imaging. Patient dose (patient-entrance dose and dose-area product), image quality (Hounsfield Unit, noise, signal-to-noise ratio and contrast-to-noise ratio), and lesion delineation (tumor-liver contrast) were assessed and compared using appropriate statistical tests. Lesion detectability, sensitivity, and predictive values were estimated for CBCT-image data using pre-treatment patient magnetic resonance imaging.ResultsThe estimated patient dose showed no statistical significance (p > 0.05) between protocols-2 and -3; the assessed image quality between these protocols manifested insignificant difference (p > 0.05). Two other phantom protocols were not considered for patient imaging due to significantly higher dose (protocols-1) and poor image quality (protocol-4). Lesion delineation and detection were insignificant (p > 0.05) between protocols-2 and -3. Lesion sensitivities generated were 81–89% (protocol-2) and 81–85% (protocol-3) for different lesion types.ConclusionData acquisition using protocols-2 and -3 provided good image quality, lesion detection and delineation with acceptable patient dose during CBCT-imaging mainly due to similar frame numbers acquired. 相似文献
15.
PurposeTo develop an automatic multimodal method for segmentation of parotid glands (PGs) from pre-registered computed tomography (CT) and magnetic resonance (MR) images and compare its results to the results of an existing state-of-the-art algorithm that segments PGs from CT images only.MethodsMagnetic resonance images of head and neck were registered to the accompanying CT images using two different state-of-the-art registration procedures. The reference domains of registered image pairs were divided on the complementary PG regions and backgrounds according to the manual delineation of PGs on CT images, provided by a physician. Patches of intensity values from both image modalities, centered around randomly sampled voxels from the reference domain, served as positive or negative samples in the training of the convolutional neural network (CNN) classifier. The trained CNN accepted a previously unseen (registered) image pair and classified its voxels according to the resemblance of its patches to the patches used for training. The final segmentation was refined using a graph-cut algorithm, followed by the dilate-erode operations.ResultsUsing the same image dataset, segmentation of PGs was performed using the proposed multimodal algorithm and an existing monomodal algorithm, which segments PGs from CT images only. The mean value of the achieved Dice overlapping coefficient for the proposed algorithm was 78.8%, while the corresponding mean value for the monomodal algorithm was 76.5%.ConclusionsAutomatic PG segmentation on the planning CT image can be augmented with the MR image modality, leading to an improved RT planning of head and neck cancer. 相似文献
16.
目的:评价智能期相选择(Smart phase)和自动追踪冻结(Snap-Shot-Freeze, SSF)技术联合应用在前门控冠状动脉CT血管成像(Coronary CT angiography, CCTA)改善图像运动伪影中的价值。方法:94例疑似心血管疾病的患者行CCTA检查。所有患者图像均采用smart phase、SSF及smart phase+SSF两种技术联合进行后处理。将原始图像(A组)、smart phase图像(B组)、SSF图像(C组)和smart phase+SSF图像(D组)导入GE AW4.6工作站。对四组患者冠状动脉三大分支(右冠状动脉、左前降支及左旋支)图像质量进行主观评价(5分法)和测量每组图像主动脉根部及前胸壁肌肉CT值和标准差,并计算图像的噪声(Noise,N)、信噪比(Signal-to-noise ratio,SNR)和对比噪声比(Contrast-to-noise ratio,CNR)和比较。结果:经smart phase处理后,A组冠状动脉三大分支图像评分均得到了明显提高(P<0.05)。经SSF矫正的A组和B组冠状动脉三大分支图像质量评分均得到明显提高(P<0.05)。Smart Phase联合SSF技术得到的图像评分在所有组中评分最高,与其他组均存在显著差异(P<0.05)。结论:Smart phase联合SSF技术可明显改善前门控CCTA图像运动伪影,值得临床推广应用。 相似文献
17.
将恒定空间分辨率离散序列小波变换(discrete sequence wavelet transform,DSWT)应用于眼底吲哚青绿血管造影(indocyanine green angiography,ICGA)图像的拼接,解决了传统基为2的DSWT会导致分解结果的空间分辨率下降的问题。提出对图像小波分解细节逼近和平滑逼近分别使用加权平均拼接和直接平均拼接进行处理的策略,以得到兼顾视觉效果和保真性的拼接结果。并且针对眼底图像背景光照不一致,提出在小波域进行处理的策略。实验结果表明拼接算法效果良好。 相似文献
18.
Brian N Jobse Cory AJR McCurry Mathieu C Morissette Rod G Rhem Martin R St?mpfli Nancy Renée Labiris 《Respiratory research》2014,15(1):42
Background
Chronic obstructive pulmonary disease (COPD) is known to greatly affect ventilation (V) and perfusion (Q) of the lung through pathologies such as inflammation and emphysema. However, there is little direct evidence regarding how these pathologies contribute to the V/Q mismatch observed in COPD and models thereof. Also, little is known regarding how smoking cessation affects V/Q relationships after inflammation and airspace enlargement have become established. To this end, we have quantified V/Q on a per-voxel basis using single photon emission computed tomography (SPECT) in mouse models of COPD and lung obstruction.Methods
Three distinct murine models were used to investigate the impact of different pathologies on V/Q, as measured by SPECT. Lipopolysaccharide (LPS) was used to produce neutrophilic inflammation, porcine pancreatic elastase (PPE) was used to produce emphysema, and long-term cigarette smoke (CS) exposure and cessation were used to investigate the combination of these pathologies.Results
CS exposure resulted in an increase in mononuclear cells and neutrophils, an increase in airspace enlargement, and an increase in V/Q mismatching. The inflammation produced by LPS was more robust and predominantly neutrophilic, compared to that of cigarette smoke; nevertheless, inflammation alone caused V/Q mismatching similar to that seen with long-term CS exposure. The emphysematous lesions caused by PPE administration were also capable of causing V/Q mismatch in the absence of inflammation. Following CS cessation, inflammatory cell levels returned to those of controls and, similarly, V/Q measures returned to normal despite evidence of persistent mild airspace enlargement.Conclusions
Both robust inflammation and extensive airspace enlargement, on their own, were capable of producing V/Q mismatch. As CS cessation resulted in a return of V/Q mismatching and inflammatory cell counts to control levels, lung inflammation is likely a major contributor to V/Q mismatch observed in the cigarette smoke exposure model as well as in COPD patients. This return of V/Q mismatching to control values also took place in the presence of mild airspace enlargement, indicating that emphysematous lesions must be of a larger volume before affecting the lung significantly. Early smoking cessation is therefore critical before emphysema has an irreversible impact on gas exchange. 相似文献19.
Weronika Jackowiak Bartosz B?k Anna Kowalik Adam Ryczkowski Ma?gorzata Skórska Ma?gorzata Paszek-Widzińska 《Reports of Practical Oncology and Radiotherapy》2015,20(5):351-357
AimThe aim of this study was to compare the intra- and interobserver contouring variability for structures with density of organ at risk in two types of tomography: kilovoltage computed tomography (KVCT) versus megavoltage computed tomography (MVCT). The intra- and interobserver differences were examined on both types of tomography for structures which simulate human tissue or organs.Materials and methodsSix structures with density of the liver, bone, trachea, lung, soft tissue and muscle were created and used. For the measurements, the special water phantom with all structures was designed. To evaluate interobserver variability, five observers delineated the structures in both types of computed tomography (CT).ResultsIntraobserver variability was in the range of 1–14% and was the largest for the liver. The observers segmented larger volumes on MVCT compared with KVCT for the trachea (79.56 ccm vs.74.91 ccm), lung (87.61 vs. 82.50), soft tissue (154.24 vs. 145.47) and muscle (164.01 vs. 157.89). For the liver (98.13 vs. 99.38) and bone (51.86 vs. 67.97), the volume on MVCT was smaller than KVCT. The statistically significant differences between observers were observed for structures with density of the liver, bone and soft tissue on KVCT and for the liver, lung and soft tissue on MVCT. For the structures with density of the trachea and muscles, there were no significant differences for both types of tomography.ConclusionsDuring the contouring process the interobserver and intraobserver contouring uncertainty was larger on MVCT, especially for structures with HU near 80, compared with KVCT. 相似文献
20.
断层间图像插值是三维重建的一个关键步骤,因为图像上像素之间的间隔常常小于断层图像之间的距离,而在三维重建需要它们有一致的分辨率.由于是同模态断层图像层间插值,对于解决同模态弹性配准问题,Thirion的demons算法比较适合.所以配准采用Demons方法.Demons算法先判断出待配准图像上各个象素点的运动方法,通过对各个象素点的移动来实现非刚性配准.在这个算法中,每张图像都被视为同灰度值轮廓的集合.该算法可以应用于精度要求比较高的体数据插值重建过程. 相似文献