首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Coronary computed tomography angiography (CCTA) in combination with first-pass CT myocardial perfusion imaging (MPI) has a better diagnostic performance than CCTA alone, compared with invasive coronary angiography as the reference standard. The aim of this study was to investigate the additional diagnostic value of first-pass CT-MPI without stress for detecting hemodynamic significance of coronary stenosis, compared with invasive fractional flow reserve (FFR). We recruited 53 patients with suspected coronary artery disease undergoing both CCTA and first-pass CT-MPI without stress and invasive FFR, and 75 vessels were analyzed. We used the same raw data for CCTA and CT-MPI. First-pass CT-MPI was reconstructed by examining the diastolic signal densities as a bull’s eye map. Invasive FFR <0.8 was considered as positive. On per-vessel analysis, the area under the receiver operating characteristic curve for CCTA plus first-pass CT-MPI and CCTA alone was 0.81 (0.73–0.90) and 0.70 (0.61–0.81), respectively (P = 0.036). CCTA plus first-pass CT-MPI without stress showed 0.73 sensitivity, 0.74 specificity, 0.53 positive predictive value, and 0.87 negative predictive value for detecting hemodynamically significant coronary stenosis. First-pass CT-MPI without stress correctly reclassified 38% of CCTA false-positive vessels as true negative. First-pass CT-MPI without stress combined with CCTA demonstrated excellent diagnostic accuracy, compared with invasive FFR as the reference standard. This technique could complement CCTA for diagnosis of coronary artery disease.  相似文献   

2.
Purpose

Invasive fractional flow reserve (FFR), the reference standard for identifying significant coronary artery disease (CAD), can be estimated non-invasively by computed tomography-derived fractional flow reserve (CT-FFR). Commercially available off-site CT-FFR showed improved diagnostic accuracy compared to coronary computed tomography angiography (CCTA) alone. However, the diagnostic performance of this lumped-parameter on-site method is unknown. The aim of this cross-sectional study was to determine the diagnostic accuracy of on-site CT-FFR in patients with suspected CAD.

Methods

A total of 61 patients underwent CCTA and invasive coronary angiography with FFR measured in 88 vessels. Significant CAD was defined as FFR and CT-FFR below 0.80. CCTA with stenosis above 50% was regarded as significant CAD. The diagnostic performance of both CT-FFR and CCTA was assessed using invasive FFR as the reference standard.

Results

Of the 88 vessels included in the analysis, 34 had an FFR of ≤?0.80. On a per-vessel basis, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 91.2%, 81.4%, 93.6%, 75.6% and 85.2% for CT-FFR and were 94.1%, 68.5%, 94.9%, 65.3% and 78.4% for CCTA. The area under the receiver operating characteristic curve was 0.91 and 0.85 for CT-FFR and CCTA, respectively, on a per-vessel basis.

Conclusion

On-site non-invasive FFR derived from CCTA improves diagnostic accuracy compared to CCTA without additional testing and has the potential to be integrated in the current clinical work-up for diagnosing stable CAD.

  相似文献   

3.
Although coronary stents have been the most important improvement in percutaneous coronary interventions in the last 10 years, it is well known to interventionalists that many patients after percutaneous transluminal coronary angioplasty (PTCA) have a favourable outcome without stenting. Coronary angiography, however, is not sensitive enough to identify those particular patients and it has been suggested that a combination of angiographic and functional criteria would be more suitable to distinguish patients with a low restenosis chance after plain balloon angioplasty. In the present study, the authors investigated the value of coronary pressure measurement for conditional stenting in 85 patients. It was demonstrated that in patients in whom a high fractional flow reserve (FFR) was present (> 0.90), the incidence of coronary events at two-year follow-up was almost three times lower than in those patients with an FFR below 0.90. Such high FFRs could be obtained in approximately 45% of all patients. In an additional group of patients, it was demonstrated by intravascular ultrasound (IVUS) studies that the mechanism of a high FFR after plain balloon angioplasty is most likely the result of a larger lumen compared with patients with a suboptimal FFR. This means that, in patients in whom both the angiographic and the functional result after PTCA is optimal, a restenosis rate is achieved similar to that achieved by stenting. Obviously, in such patients, additional stenting and a number of problems in the long-term possibly related to stenting can be avoided. Therefore, coronary angiography and coronary pressure measurement have a complementary value in the evaluation of PTCA results and such information can be easily obtained by using a pressure wire instead of a regular guidewire.  相似文献   

4.

Determining the anatomic severity and extent of coronary artery disease (CAD) by means of coronary computed tomography angiography (CCTA) and its effect on perfusion using myocardial perfusion imaging (MPI) form the pillars of the non-invasive imaging assessment of CAD. This review will 1) focus on CCTA and [15O]H2O positron emission tomography MPI as stand-alone imaging modalities and their combined use for detecting CAD, 2) highlight some of the lessons learned from the PACIFIC trial (Comparison of Coronary CT Angiography, SPECT, PET, and Hybrid Imaging for Diagnosis of Ischemic Heart Disease Determined by Fractional Flow Reserve (FFR) (NCT01521468)), and 3) discuss the use of [15O]H2O PET MPI in the clinical work-up of patients with a chronic coronary total occlusion (CTO).

  相似文献   

5.
Abnormal haemodynamic parameters are associated with atheroma plaque progression and instability in coronary arteries. Flow recirculation, shear stress and pressure gradient are understood to be important pathogenic mediators in coronary disease. The effect of freedom of coronary artery movement on these parameters is still unknown. Fluid–structure interaction (FSI) simulations were carried out in 25 coronary artery models derived from authentic human coronaries in order to investigate the effect of degree of freedom of movement of the coronary arteries on flow recirculation, wall shear stress (WSS) and wall pressure gradient (WPG). Each FSI model had distinctive supports placed upon it. The quantitative and qualitative differences in flow recirculation, maximum wall shear stress (MWSS), areas of low wall shear stress (ALWSS) and maximum wall pressure gradient (MWPG) for each model were determined. The results showed that greater freedom of movement was associated with lower MWSS, smaller ALWSS, smaller flow recirculation zones and lower MWPG. With increasing percentage diameter stenosis (%DS), the effect of degree of freedom on flow recirculation and WSS diminished. Freedom of movement is an important variable to be considered for computational modelling of human coronary arteries, especially in the setting of mild to moderate stenosis.

Abbreviations: 3D: Three-dimensional; 3DR: Three-dimensional Reconstruction; 3D-QCA: Three-dimensional quantitative coronary angiography; ALWSS: Areas of low wall shear stress; CAD: Coronary artery disease; CFD: Computational fluid dynamics; %DS: Diameter stenosis percentage; EPCS: End point of counter-rotating streamlines; FSI: Fluid–structure interaction; IVUS: Intravascular ultrasound; LAD: Left anterior descending; MWSS: Maximum wall shear stress; SST: Shear stress transport; TAWSS: Time-averaged wall shear stress; WSS: wall shear stress; WPG: Wall pressure gradient; MWPG: Maximum wall pressure gradient; FFR: Fractional flow reserve; iFR: Instantaneous wave-free ratio  相似文献   


6.

Background

Variability in intracoronary computed tomography (CT) number may influence vessel quantification. We confirmed the feasibility of a novel method for measuring vessel diameter and area using coronary CT angiography (CCTA) with an optimized intracoronary CT number, 350 HU.

Methods

We performed intravascular ultrasound (IVUS) imaging in 52 patients with significant stenosis detected by coronary CT angiography targeting 350 HU using a CT number-controlling system. We measured 0-to-0 HU distances in the cross-sectional coronary images of 32 patients. We analyzed the ratio of 0-to-0 HU distances in CT images to media-to-media distances in IVUS images (C:I ratio). The area of ≥0 HU for 103 representative points in the remaining 20 patients was compared to the area of the traced external elastic membrane (EEM) in IVUS images.

Results

There was a strong correlation between 0-to-0 HU distance in CT images and media-to-media diameter in IVUS images (r = 0.97, p<0.001). The C:I ratio was 1.1. EEM area was estimated by dividing the area of ≥0 HU by the square of C:I. There was also a strong correlation between the estimated EEM area and the EEM area in IVUS images (r = 0.95, p<0.001).

Conclusions

Media-to-media diameter and EEM area can be estimated by CCTA targeting the optimized intracoronary CT number when blood vessel borders are defined at 0 HU.  相似文献   

7.
To evaluate the hemodynamic impact of coronary stenoses, the fractional (FFR) or coronary flow velocity reserve (CFVR) usually is measured. The combined measurement of instantaneous flow velocity and pressure gradient (v-dp relation) is rarely used in humans. We derived from the v-dp relation a new index, dp(v50) (pressure gradient at flow velocity of 50 cm/s), and compared the diagnostic performance of dp(v50), CFVR, and FFR. Before coronary angiography was performed, patients underwent noninvasive stress testing. In all coronary vessels with an intermediate or severe stenosis, the flow velocity, aortic, and distal coronary pressure were measured simultaneously with a Doppler and pressure guidewire after induction of hyperemia. After regression analysis of all middiastolic flow velocity and pressure gradient data, the dp(v50) was calculated. With the use of the results of noninvasive stress testing, the dp(v50) cutoff value was established at 22.4 mmHg. In 77 patients, 124 coronary vessels with a mean 39% (SD 19) diameter stenosis were analyzed. In 43 stenoses, ischemia was detected. We found a sensitivity, specificity, and accuracy of 56%, 86%, and 76% for CFVR; 77%, 99%, and 91% for FFR; and 95%, 95%, and 95% for dp(v50). To establish that dp(v50) is not dependent on maximal hyperemia, dp(v50) was recalculated after omission of the highest quartile of flow velocity data, showing a difference of 3%. We found that dp(v50) provided the highest sensitivity and accuracy compared with FFR and CFVR in the assessment of coronary stenoses. In contrast to CFVR and FFR, assessment of dp(v50) is not dependent on maximal hyperemia.  相似文献   

8.
Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD.  相似文献   

9.

Studies performed in the last two decades demonstrate that after successful percutaneous coronary intervention (PCI) of a chronically occluded coronary artery, the physiology of the chronic total occlusion (CTO) vessel and dependent microvasculature does not normalise immediately but improves significantly over time. Generally, there is an increase in fractional flow reserve (FFR) in the CTO artery, a decrease in collateral blood supply and an increase in FFR in the donor artery accompanied by an increase in blood flow and decrease in microvascular resistance in the myocardium supplied by the CTO vessel. Analogous to these physiological changes, positive remodelling of the distal CTO artery also occurs over time, and intravascular imaging can be helpful for analysing distal vessel parameters. Follow-up coronary angiography with physiological measurements after several weeks to months can be helpful and informative in a subset of patients in order to decide upon the necessity for treatment of residual coronary artery stenosis in the vessel distal to the CTO or in the contralateral donor artery, as well as in deciding whether stent optimisation is indicated. We suggest that such physiological guidance of CTO procedures avoids unnecessary overtreatment during the initial procedure, guides interventions at follow-up, and improves our understanding of what PCI in CTO means.

  相似文献   

10.

Background and Aims

The degree of coronary artery stenosis should be assessed both anatomically and functionally. We observed that the intensity of blood speckle (IBS) on intravascular ultrasound (IVUS) is low proximal to a coronary artery stenosis, and high distal to the stenosis. We defined step-up IBS as the distal minus the proximal IBS, and speculated that this new parameter could be used for the functional evaluation of stenosis on IVUS. The aims of this study were to assess the relationships between step-up IBS and factors that affect coronary blood flow, and between step-up IBS and fractional flow reserve (FFR).

Methods and Results

This study enrolled 36 consecutive patients with angina who had a single moderate stenosis in the left anterior descending artery. All patients were evaluated by integrated backscatter IVUS and intracoronary pressure measurements. FFR was calculated from measurements using a coronary pressure wire during hyperemia. Conventional gray-scale IVUS images were recorded, and integrated backscatter was measured in three cross-sectional slices proximal and distal to the stenosis. Step-up IBS was calculated as (mean distal integrated backscatter value) − (mean proximal integrated backscatter value). Stepwise multiple linear regression analysis showed that the heart rate (r = 0.45, P = 0.005), ejection fraction (r = −0.39, P = 0.01), and hemoglobin level (r = −0.32, P = 0.04) were independently correlated with step-up IBS, whereas proximal and distal IBS were not associated with these factors. There was a strong inverse correlation between step-up IBS and FFR (r = −0.84, P < 0.001), which remained significant on stepwise multiple linear regression analysis.

Conclusions

The newly defined parameter of step-up IBS is potentially useful for the functional assessment of coronary artery stenosis.  相似文献   

11.
The association between the levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) and the severity of coronary artery disease (CAD) diagnosed by coronary angiography and other approaches has been investigated. The clinical application of NT-proBNP is restricted by the drawbacks of these techniques now available in screening out patients who need intensive or conservative treatment. Fractional flow reserve (FFR) is superior to coronary angiography and other functional indicators. Accordingly, we designed to investigate the association between NT-proBNP and myocardial ischemia from the perspective of anatomy and physiology in patients with unstable angina and preserved left ventricular function. Plasma samples were collected from 110 patients and NT-proBNP levels were measured by radioimmunoassay. The severity of coronary artery stenosis in patients was measured by coronary angiography and FFR. Stenosis ≥50% in the left main artery or stenosis of 70%, and fractional flow reserve (FFR) ≤0.80 in one or more coronary branches with diameter ≥2 mm were defined as “positive”, which require revascularization. NT-proBNP levels increased progressively between patients with negative and positive angiographic results (p < 0.05), and between FFR-negative and FFR-positive patients (p < 0.05). A significant correlation was observed between log NT-proBNP and log GS (GS = Gensini score, p < 0.001). NT-proBNP level serves as a predictor of positive results of angiographic stenosis and FFR, with the area under the receiver operating characteristic curve being 0.697 and 0.787, respectively. NT-proBNP levels are correlated with the severity of anatomic coronary obstruction and inducible myocardial ischemia, but NT-proBNP per se is insufficient to identify clinically significant angiographic and physiological stenoses.  相似文献   

12.
Coronary artery pressure-drop and distensibility (compliance) are two major, seemingly unrelated, parameters in the cardiovascular clinical setting, which are indicative of coronary arteries patency and atherosclerosis severity. While pressure drop is related to flow, and therefore serves as a functional indicator of a stenosis severity, the arterial distensibility is indicative of the arterial stiffness, and hence the arterial wall composition. In the present study, we hypothesized that local pressure drops are dependent on the arterial distensibility, and hence can provide information on both indices. The clinical significance is that a single measurement of pressure drop could potentially provide both functional and bio-mechanical metrics of lesions, and thus assist in real-time decision making prior to stenting. The goal of the current study was to set the basis for understanding this relationship, and define the accuracy and sensitivity required from the pressure measurement system. The investigation was performed using numerical fluid–structure interaction (FSI) simulations, validated experimentally using our high accuracy differential pressure measurement system. Simplified silicone mock coronary arteries with zero to intermediate size stenoses were used, and various combinations of arterial distensibility, diameter, and flow rate were simulated. Results of hyperemic flow cases were also compared to fractional flow reserve (FFR). The results indicate the potential clinical superiority of a high accuracy pressure drop-based parameter over FFR, by: (i) being more lesion-specific, (ii) the possibility to circumvent the FFR dependency on pharmacologically-induced hyperemia, and, (iii) by providing both functional and biomechanical lesion-specific information.  相似文献   

13.
Coronary flow reserve (CFR) and fractional flow reserve (FFR) are important physiological indexes for coronary disease. The purpose of this study was to validate the CFR and FFR measurement techniques using only angiographic image data. Fifteen swine were instrumented with an ultrasound flow probe on the left anterior descending artery (LAD). Microspheres were gradually injected into the LAD to create microvascular disruption. An occluder was used to produce stenosis. Contrast material injections were made into the left coronary artery during image acquisition. Volumetric blood flow from the flow probe (Q(q)) was continuously recorded. Angiography-based blood flow (Q(a)) was calculated by using a time-density curve based on the first-pass analysis technique. Flow probe-based CFR (CFR(q)) and angiography-based CFR (CFR(a)) were calculated as the ratio of hyperemic to baseline flow using Q(q) and Q(a), respectively. Relative angiographic FFR (relative FFR(a)) was calculated as the ratio of the normalized Q(a) in LAD to the left circumflex artery (LC(X)) during hyperemia. Flow probe-based FFR (FFR(q)) was measured from the ratio of hyperemic flow with and without disease. CFR(a) showed a strong correlation with the gold standard CFR(q) (CFR(a) = 0.91 CFR(q) + 0.30; r = 0.90; P < 0.0001). Relative FFR(a) correlated linearly with FFR(q) (relative FFR(a) = 0.86 FFR(q) + 0.05; r = 0.90; P < 0.0001). The quantification of CFR and relative FFR(a) using angiographic image data was validated in a swine model. This angiographic technique can potentially be used for coronary physiological assessment during routine cardiac catheterization.  相似文献   

14.
A hemodynamic analysis of coronary blood flow must be based on the measured branching pattern and vascular geometry of the coronary vasculature. We recently developed a computer reconstruction of the entire coronary arterial tree of the porcine heart based on previously measured morphometric data. In the present study, we carried out an analysis of blood flow distribution through a network of millions of vessels that includes the entire coronary arterial tree down to the first capillary branch. The pressure and flow are computed throughout the coronary arterial tree based on conservation of mass and momentum and appropriate pressure boundary conditions. We found a power law relationship between the diameter and flow of each vessel branch. The exponent is approximately 2.2, which deviates from Murray's prediction of 3.0. Furthermore, we found the total arterial equivalent resistance to be 0.93, 0.77, and 1.28 mmHg.ml(-1).s(-1).g(-1) for the right coronary artery, left anterior descending coronary artery, and left circumflex artery, respectively. The significance of the present study is that it yields a predictive model that incorporates some of the factors controlling coronary blood flow. The model of normal hearts will serve as a physiological reference state. Pathological states can then be studied in relation to changes in model parameters that alter coronary perfusion.  相似文献   

15.

Background

In literature, the effect of the inflow boundary condition was investigated by examining the impact of the waveform and the shape of the spatial profile of the inlet velocity on the cardiac hemodynamics. However, not much work has been reported on comparing the effect of the different combinations of the inlet/outlet boundary conditions on the quantification of the pressure field and flow distribution patterns in stenotic right coronary arteries.

Method

Non-Newtonian models were used to simulate blood flow in a patient-specific stenotic right coronary artery and investigate the influence of different boundary conditions on the phasic variation and the spatial distribution patterns of blood flow. The 3D geometry of a diseased artery segment was reconstructed from a series of IVUS slices. Five different combinations of the inlet and the outlet boundary conditions were tested and compared.

Results

The temporal distribution patterns and the magnitudes of the velocity, the wall shear stress (WSS), the pressure, the pressure drop (PD), and the spatial gradient of wall pressure (WPG) were different when boundary conditions were imposed using different pressure/velocity combinations at inlet/outlet. The maximum velocity magnitude in a cardiac cycle at the center of the inlet from models with imposed inlet pressure conditions was about 29% lower than that from models using fully developed inlet velocity data. Due to the fact that models with imposed pressure conditions led to blunt velocity profile, the maximum wall shear stress at inlet in a cardiac cycle from models with imposed inlet pressure conditions was about 29% higher than that from models with imposed inlet velocity boundary conditions. When the inlet boundary was imposed by a velocity waveform, the models with different outlet boundary conditions resulted in different temporal distribution patterns and magnitudes of the phasic variation of pressure. On the other hand, the type of different boundary conditions imposed at the inlet and the outlet did not have significant effect on the spatial distribution patterns of the PD, the WPG and the WSS on the lumen surface, regarding the locations of the maximum and the minimum of each quantity.

Conclusions

The observations from this study indicated that the ways how pressure and velocity boundary conditions are imposed in computational models have considerable impact on flow velocity and shear stress predictions. Accuracy of in vivo measurements of blood pressure and velocity is of great importance for reliable model predictions.
  相似文献   

16.
Myocardial fractional flow reserve (FFR(myo)) and coronary flow reserve (CFR), measured with guidewire, and quantitative angiography (QA) are widely used in combination to distinguish ischemic from non-ischemic coronary stenoses. Recent studies have shown that simultaneous measurements of FFR(myo) and CFR are recommended to dissociate conduit epicardial coronary stenoses from distal resistance microvascular disease. In this study, a more comprehensive diagnostic parameter, named as lesion flow coefficient, c, is proposed. The coefficient, c, which accounts for mean pressure drop, Delta p, mean coronary flow, Q, and percentage area stenosis, can be used to assess the hemodynamic severity of a coronary artery stenoses. Importantly, the contribution of viscous loss and loss due to momentum change for several lesion sizes can be distinguished using c. FFR(myo), CFR and c were calculated for pre-angioplasty, intermediate and post-angioplasty epicardial lesions, without microvascular disease. While hyperemic c decreased from 0.65 for pre-angioplasty to 0.48 for post-angioplasty lesion with guidewire of size 0.35 mm, FFR(myo) increased from 0.52 to 0.87, and CFR increased from 1.72 to 3.45, respectively. Thus, reduced loss produced by momentum change due to lower percentage area stenosis decreased c. For post-angioplasty lesion, c decreased from 0.55 to 0.48 with the insertion of guidewire. Hence, increased viscous loss due to the presence of guidewire decreased c compared with a lesion without guidewire. Further, c showed a linear relationship with FFR(myo), CFR and percentage area stenosis for pre-angioplasty, intermediate and post-angioplasty lesion. These baseline values of c were developed from fluid dynamics fundamentals for focal lesions, and provided a single hemodynamic endpoint to evaluate coronary stenosis severity.  相似文献   

17.

Background

Atherosclerosis is an inflammatory condition and increased blood levels of inflammatory biomarkers have been observed in acute coronary syndromes. In addition, high expression of inflammatory markers is associated with worse prognosis of coronary artery disease. The presence and extent of inducible ischemia in patients with stable angina has previously been shown to have strong prognostic value. We hypothesized that evidence of inducible myocardial ischemia by local lesions, as measured by fractional flow reserve (FFR), is associated with increased levels of blood based inflammatory biomarkers.

Methods

Whole blood samples of 89 patients with stable angina pectoris and 16 healthy controls were analyzed. The patients with stable angina pectoris underwent coronary angiography and FFR of all coronary lesions.We analyzed plasma levels of cytokines IL-6, IL-8 and TNF-α and membrane expression of Toll-like receptor 2 and 4, CD11b, CD62L and CD14 on monocytes and granulocytes as markers of inflammation.Furthermore, we quantified the severity of hemodynamically significant coronary artery disease by calculating Functional Syntax Score (FSS), an extension of the Syntax Score.

Results

For the majority of biomarkers, we observed lower levels in the healthy control group compared with patients with stable angina who underwent coronary catheterization.We found no difference for any of the selected biomarkers between patients with a positive FFR (≤0.75) and negative FFR (>0.80). We observed no relationship between the investigated biomarkers and FSS.

Conclusion

The presence of local atherosclerotic lesions that result in inducible myocardial ischemia as measured by FFR in patients with stable coronary artery disease is not associated with increased plasma levels of IL-6, IL-8 and TNF-α or increased expression of TLR2 and TLR4, CD11b, CD62L and CD14 on circulating leukocytes.  相似文献   

18.
Pressure-based fractional flow reserve (FFR) is used clinically to evaluate the functional severity of a coronary stenosis, by predicting relative maximal coronary flow (Q(s)/Q(n)). It is considered to be independent of hemodynamic conditions, which seems unlikely because stenosis resistance is flow dependent. Using a resistive model of an epicardial stenosis (0-80% diameter reduction) in series with the coronary microcirculation at maximal vasodilation, we evaluated FFR for changes in coronary microvascular resistance (R(cor) = 0.2-0.6 mmHg. ml(-1). min), aortic pressure (P(a) = 70-130 mmHg), and coronary outflow pressure (P(b) = 0-15 mmHg). For a given stenosis, FFR increased with decreasing P(a) or increasing R(cor). The sensitivity of FFR to these hemodynamic changes was highest for stenoses of intermediate severity. For P(b) > 0, FFR progressively exceeded Q(s)/Q(n) with increasing stenosis severity unless P(b) was included in the calculation of FFR. Although the P(b)-corrected FFR equaled Q(s)/Q(n) for a given stenosis, both parameters remained equally dependent on hemodynamic conditions, through their direct relationship to both stenosis and coronary resistance.  相似文献   

19.
The heart muscle is nourished by a complex system of blood vessels that make up the coronary circulation. Here we show that the design of the coronary circulation has a functional hierarchy. A full anatomic model of the coronary arterial tree, containing millions of blood vessels down to the capillary vessels, was simulated based on previously measured porcine morphometric data. A network analysis of blood flow through every vessel segment was carried out based on the laws of fluid mechanics and appropriate boundary conditions. Our results show an abrupt change in cross-sectional area that demarcates the transition from epicardial (EPCA) to intramyocardial (IMCA) coronary arteries. Furthermore, a similar pattern of blood flow was observed with a corresponding transition from EPCA to IMCA. These results suggest functional differences between the two types of vessels. An additional abrupt change occurs in the IMCA in relation to flow velocity. The velocity is fairly uniform proximal to these vessels but drops significantly distal to those vessels toward the capillary branches. This finding suggests functional differences between large and small IMCA. Collectively, these observations suggest a novel functional hierarchy of the coronary vascular tree and provide direct evidence of a structure-function relation.  相似文献   

20.
The branching pattern of the coronary arteries and veins is asymmetric, i.e., many small vessels branch off of a large trunk such that the two daughter vessels at a bifurcation are of unequal diameters and lengths. One important implication of the geometric vascular asymmetry is the dispersion of blood flow at a bifurcation, which leads to large spatial heterogeneity of myocardial blood flow. To document the asymmetric branching pattern of the coronary vessels, we computed an asymmetry ratio for the diameters and lengths of all vessels, defined as the ratio of the daughter diameters and lengths, respectively. Previous data from silicone elastomer cast of the entire coronary vasculature including arteries, arterioles, venules, and veins were analyzed. Data on smaller vessels were obtained from histological specimens by optical sectioning, whereas data on larger vessels were obtained from vascular casts. Asymmetry ratios for vascular areas, volumes, resistances, and flows of the various daughter vessels were computed from the asymmetry ratios of diameters and lengths for every order of mother vessel. The results show that the largest orders of arterial and venous vessels are most asymmetric and the degree of asymmetry decreases toward the smaller vessels. Furthermore, the diameter asymmetry at a bifurcation is significantly larger for the coronary veins (1.7-6.8 for sinus veins) than the corresponding arteries (1.5-5.8 for left anterior descending coronary artery) for orders 2-10, respectively. The reported diameter asymmetry at a bifurcation leads to significant heterogeneity of blood flow at a bifurcation. Hence, the present data quantify the dispersion of blood flow at a bifurcation and are essential for understanding flow heterogeneity in the coronary circulation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号