首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
Modelling flow-diverting (FD) stents as porous media (PM) markedly improves the efficiency of computational fluid dynamics (CFD) simulations in the study of intracranial aneurysm treatment. Nonetheless, the parameters of PM models adopted for simulations up until now were rarely calibrated to match the represented FD structure. We therefore sought to evaluate the PM parameters for a representative variety of commercially available stents, so characterising the flow-diversion behaviours of different FD devices on the market.We generated fully-resolved geometries for treatments using PED, Silk+, FRED, and dual PED stents. We then correspondingly derived the calibrated PM parameters—permeability (k) and inertial resistance factor (C2)—for each stent design from CFD simulations, to ensure the calibrated PM model has identical flow resistance to the FD stent it represents. With each of the calibrated PM models respectively deployed in two aneurysms, we studied the flow-diversion effects of these stent configurations.This work for the first time reported several sets of parameters for PM models, which is vital to address the current knowledge gap and rectify the errors in PM model simulations, thereby setting right the modelling protocol for future studies using PM models. The flow resistance parameters were strongly affected by porosity and effective thickness of the commercial stents, and thus accounted for in the PM models. Flow simulations using the PM stent models revealed differences in aneurysmal mass flowrate (MFR) and energy loss (EL) between various stent designs.This study improves the practicability of FD simulation by using calibrated PM models, providing an individualised method with improved simulation efficiency and accuracy.  相似文献   

2.
Endovascular intervention using traditional neurovascular stents and densely braided flow diverters (FDs) have become the preferred treatment strategies for traditionally challenging intracranial aneurysms. Modeling stent and FD deployment in patient-specific aneurysms and its flow modification results prior to the actual intervention can potentially predict the patient outcome and treatment optimization. We present a clinically focused, streamlined virtual stenting workflow that efficiently simulates stent and FD treatment in patient-specific aneurysms based on expanding a simplex mesh structure. The simplex mesh is generated using an innovative vessel-specific initialization technique, which uses the patient’s parent artery diameter to identify the initial position of the simplex mesh inside the artery. A novel adaptive expansion algorithm enables the acceleration of deployment process by adjusting the expansion forces based on the distance of the simplex mesh from the parent vessel. The virtual stenting workflow was tested by modeling the treatment of two patient-specific aneurysms using the Enterprise stent and the Pipeline Embolization Device (commercial FD). Both devices were deployed in the aneurysm models in a few seconds. Computational fluid dynamics analyses of pre- and post-treatment aneurysmal hemodynamics show flow reduction in the aneurysmal sac in treated aneurysms, with the FD diverting more flow than the Enterprise stent. The test results show that this workflow can rapidly simulate clinical deployment of stents and FDs, hence paving the way for its future clinical implementation.  相似文献   

3.
Flow diverter (FD) is an emerging neurovascular device based on self-expandable braided stent for treating intracranial aneurysms. Variability in FD outcome has underscored a need for investigating the hemodynamic effect of fully deployed FD in patient-specific aneurysms. Image-based computational fluid dynamics, which can provide important hemodynamic insight, requires accurate representation of FD in deployed states. We developed a finite element analysis (FEA) based workflow for simulating mechanical deployment of FD in patient-specific aneurysms. We constructed FD models of interlaced wires emulating the Pipeline Embolization Device, using 3D finite beam elements to account for interactions between stent strands, and between the stent and other components. The FEA analysis encompasses all steps that affect the final deployed configuration including stent crimping, delivery and expansion. Besides the stent, modeling also includes key components of the FD delivery system such as microcatheter, pusher, and distal coil. Coordinated maneuver of these components allowed the workflow to mimic clinical operation of FD deployment and to explore clinical strategies. The workflow was applied to two patient-specific aneurysms. Parametric study indicated consistency of the deployment result against different friction conditions, but excessive intra-stent friction should be avoided. This study demonstrates for the first time mechanical modeling of braided FD stent deployment in cerebral vasculature to produce realistic deployed configuration, thus paving the way for accurate CFD analysis of flow diverters for reliable prediction and optimization of treatment outcome.  相似文献   

4.
Embolic coiling is the most popular endovascular treatment available for cerebral aneurysms. Nevertheless, the embolic coiling of wide-neck aneurysms is challenging and, in many cases, ineffective. Use of highly porous stents to support coiling of wide-neck aneurysms has become a common procedure in recent years. Several studies have also demonstrated that high porosity stents alone can significantly alter aneurysmal hemodynamics, but differences among different stent configurations have not been fully characterized. As a result, it is usually unclear which stent configuration is optimal for treatment. In this paper, we present a flow study that elucidates the influence of stent configuration on cerebral aneurysm fluid dynamics in an idealized wide-neck basilar tip aneurysm model. Aneurysmal fluid dynamics for three different stent configurations (half-Y, Y and, cross-bar) were first quantified using particle image velocimetry and then compared. Computational fluid dynamics (CFD) simulations were also conducted for selected stent configurations to facilitate validation and provide more detailed characterizations of the fluid dynamics promoted by different stent configurations. In vitro results showed that the Y stent configuration reduced cross-neck flow most significantly, while the cross-bar configuration reduced velocity magnitudes within the aneurysmal sac most significantly. The half-Y configuration led to increased velocity magnitudes within the aneurysmal sac at high parent-vessel flow rates. Experimental results were in strong agreement with CFD simulations. Simulated results indicated that differences in fluid dynamic performance among the different stent configurations can be attributed primarily to protruding struts within the bifurcation region.  相似文献   

5.
Endovascular coiling is the most common treatment for cerebral aneurysms. During the treatment, a sequence of embolic coils with different stiffness, shapes, sizes, and lengths is deployed to fill the aneurysmal sac. Although coil packing density has been clinically correlated with treatment success, many studies have also reported success at low packing densities, as well as recurrence at high packing densities. Such reports indicate that other factors may influence treatment success. In this study, we used a novel finite element approach and computational fluid dynamics (CFD) to investigate the effects of packing density, coil shape, aneurysmal neck size, and parent vessel flow rate on aneurysmal hemodynamics. The study examines a testbed of 80 unique CFD simulations of post-treatment flows in idealized basilar tip aneurysm models. Simulated coil deployments were validated against in vitro and in vivo deployments. Among the investigated factors, packing density had the largest effect on intra-aneurysmal velocities. However, multifactor analysis of variance showed that coil shape can also have considerable effects, depending on packing density and neck size. Further, linear regression analysis showed an inverse relationship between mean void diameter in the aneurysm and mean intra-aneurysmal velocities, which underscores the importance of coil distribution and thus coil shape. Our study suggests that while packing density plays a key role in determining post-treatment hemodynamics, other factors such as coil shape, aneurysmal geometry, and parent vessel flow may also be very important.  相似文献   

6.
《Process Biochemistry》2010,45(8):1362-1367
The effect of magnetic fields (MF) on glutathione (GSH) production by Saccharomyces cerevisiae ATCC 7754 was studied. For this purpose, a factorial design of experiments was used to determine the influence of the time of exposure (8–16 h) and MF induction (25.0–34.3 mT), in GSH and biomass production. Additionally, control experiments (CE), without the application of MF, were performed. The results indicated the existence of favourable alterations in GSH and biomass concentrations due to the application of MF. In all experiments, the amount of biomass produced was higher than in CE and, with regard to GSH yield, in all the experiments at 24 and 48 h it was higher and in three experiments at 72 h of culture. The highest specific GSH yield (20.9 mgGSH/gbiomass), GSH yield (340.0 mg/L) and biomass (16.26 g/L) were obtained using a MF induction of 25.0 mT for 16 h. These results were 16.1%, 39.0% and 19.6% higher than in the CE, respectively. Through statistical analysis it was found that the MF induction was a significant factor in GSH yield, and also it was observed that, within the range of the experimental conditions used, the lower MF induction, the higher the GSH yield.  相似文献   

7.

Purpose

Flow diverters (FD) are increasingly being considered for treating large or giant wide-neck aneurysms. Clinical outcome is highly variable and depends on the type of aneurysm, the flow diverting device and treatment strategies. The objective of this study was to analyze the effect of different flow diverting strategies together with parent artery curvature variations on altering intra-aneurysmal hemodynamics.

Methods

Four ideal intracranial aneurysm models with different parent artery curvature were constructed. Computational fluid dynamics (CFD) simulations of the hemodynamics before and after applying five types of flow diverting strategies (single FD, single FD with 5% and 10% packing density of coils, two FDs with 25% and 50% overlapping rate) were performed. Changes in pressure, wall shear stress (WSS), relative residence time (RRT), inflow velocity and inflow volume rate were calculated and compared.

Results

Each flow diverting strategy resulted in enhancement of RRT and reduction of normalized mean WSS, inflow volume rate and inflow velocity in various levels. Among them, 50% overlapped FD induced most effective hemodynamic changes in RRT and inflow volume rate. The mean pressure only slightly decreased after treatment. Regardless of the kind of implantation of FD, the mean pressure, inflow volume rate and inflow velocity increased and the RRT decreased as the curvature of the parent artery increased.

Conclusions

Of all flow diverting strategies, overlapping FDs induced most favorable hemodynamic changes. Hemodynamics alterations post treatment were substantially influenced by parent artery curvature. Our results indicate the need of an individualized flow diverting strategy that is tailored for a specific aneurysm.  相似文献   

8.
Coronary stent design affects the spatial distribution of wall shear stress (WSS), which can influence the progression of endothelialization, neointimal hyperplasia, and restenosis. Previous computational fluid dynamics (CFD) studies have only examined a small number of possible geometries to identify stent designs that reduce alterations in near-wall hemodynamics. Based on a previously described framework for optimizing cardiovascular geometries, we developed a methodology that couples CFD and three-dimensional shape-optimization for use in stent design. The optimization procedure was fully-automated, such that solid model construction, anisotropic mesh generation, CFD simulation, and WSS quantification did not require user intervention. We applied the method to determine the optimal number of circumferentially repeating stent cells (N(C)) for slotted-tube stents with various diameters and intrastrut areas. Optimal stent designs were defined as those minimizing the area of low intrastrut time-averaged WSS. Interestingly, we determined that the optimal value of N(C) was dependent on the intrastrut angle with respect to the primary flow direction. Further investigation indicated that stent designs with an intrastrut angle of approximately 40 deg minimized the area of low time-averaged WSS regardless of vessel size or intrastrut area. Future application of this optimization method to commercially available stent designs may lead to stents with superior hemodynamic performance and the potential for improved clinical outcomes.  相似文献   

9.
Adjusting hemodynamics via flow diverter (FD) implantation is emerging as a novel method of treating cerebral aneurysms. However, most previous FD-related hemodynamic studies were based on virtual FD deployment, which may produce different hemodynamic outcomes than realistic (in vivo) FD deployment. We compared hemodynamics between virtual FD and realistic FD deployments in rabbit aneurysm models using computational fluid dynamics (CFD) simulations. FDs were implanted for aneurysms in 14 rabbits. Vascular models based on rabbit-specific angiograms were reconstructed for CFD studies. Real FD configurations were reconstructed based on micro-CT scans after sacrifice, while virtual FD configurations were constructed with SolidWorks software. Hemodynamic parameters before and after FD deployment were analyzed. According to the metal coverage (MC) of implanted FDs calculated based on micro-CT reconstruction, 14 rabbits were divided into two groups (A, MC >35%; B, MC <35%). Normalized mean wall shear stress (WSS), relative residence time (RRT), inflow velocity, and inflow volume in Group A were significantly different (P<0.05) from virtual FD deployment, but pressure was not (P>0.05). The normalized mean WSS in Group A after realistic FD implantation was significantly lower than that of Group B. All parameters in Group B exhibited no significant difference between realistic and virtual FDs. This study confirmed MC-correlated differences in hemodynamic parameters between realistic and virtual FD deployment.  相似文献   

10.
Residual force enhancement (RFE) and force depression (FD) refer to an increased or decreased force following an active lengthening or shortening contraction, respectively, relative to the isometric force produced at the same activation level and muscle length. Our intent was to determine if EMG characteristics differed in the RFE or FD states compared with a purely isometric reference contraction for maximal and submaximal voluntary activation of the adductor pollicis muscle. Quantifying these alterations to EMG in history-dependent states allows for more accurate modeling approaches for movement control in the future. For maximal voluntary contractions (MVC), RFE was 6–15% (P < 0.001) and FD was 12–19% (P < 0.001). The median frequency of the EMG was not different between RFE, FD and isometric reference contractions for the 100% and 40% MVC intensities (P > 0.05). However, root mean square EMG (EMGRMS) amplitude for the submaximal contractions was higher in the FD and lower in the RFE state, respectively (P < 0.05). For maximal contractions, EMGRMS was lower for the FD state but was the same for the RFE state compared to the isometric reference contractions (P > 0.05). Neuromuscular efficiency (NME; force/EMG) was lower in the force depressed state and higher in the force enhanced state (P < 0.05) compared to the isometric reference contractions. EMG spectral properties were not altered between the force-enhanced and depressed states relative to the isometric reference contractions, while EMG amplitude measures were.  相似文献   

11.
Freezing is a major environmental limitation to crop productivity for a number of species including legumes. We investigated the genetic determinism of freezing tolerance in the model legume Medicago truncatula Gaertn (M. truncatula). After having observed a large variation for freezing tolerance among 15 M. truncatula accessions, the progeny of a F6 recombinant inbred line population, derived from a cross between two accessions, was acclimated to low above-freezing temperatures and assessed for: (a) number of leaves (NOL), leaf area (LA), chlorophyll content index (CCI), shoot and root dry weights (SDW and RDW) at the end of the acclimation period and (b) visual freezing damage (FD) during the freezing treatment and 2 weeks after regrowth and foliar electrolyte leakage (EL) 2 weeks after regrowth. Consistent QTL positions with additive effects for FD were found on LG1, LG4 and LG6, the latter being the most explanatory (R 2 ≈ 40 %). QTL for NOL, QTL for EL, NOL and RDW, and QTL for EL and CCI colocalized with FD QTL on LG1, LG4 and LG6, respectively. Favorable alleles for these additive effects were brought by the same parent suggesting that this accession contributes to superior freezing tolerance by affecting plants’ capacity to maintain growth at low above-freezing temperatures. No epistatic effects were found between FD QTL, but for each of the studied traits, 3–6 epistatic effects were detected between loci not detected directly as QTL. These results open the way to the assessment of syntenic relationships between QTL for frost tolerance in M. truncatula and cultivated legume species.  相似文献   

12.
Background and aimsBecause of their pluripotency, human CD34+ peripheral blood progenitor cells (PBPC) are targets of interest for the treatment of many acquired and inherited disorders using gene therapeutic approaches. Unfortunately, most current vector systems lack either sufficient transduction efficiency or an appropriate safety profile. Standard single-stranded recombinant adeno-associated virus 2 (AAV2)-based vectors offer an advantageous safety profile, yet lack the required efficiency in human PBPC.MethodsA panel of pseudotyped AAV vectors (designated AAV2/x, containing the vector genome of serotype 2 and capsid of serotype x, AAV2/1–AAV2/6) was screened on primary human granulocyte–colony-stimulating factor (G-CSF)-mobilized CD34+ PBPC to determine their gene transfer efficacy. Additionally, double-stranded self-complementary AAV (dsAAV) were used to determine possible second-strand synthesis limitations.ResultsAAV2/6 vectors proved to be the most efficient [12.8% (1.8–25.4%) transgene-expressing PBPC after a single transduction], being significantly more efficient (all P < 0.005) than the other vectors [AAV2/2, 2.0% (0.2–7.3%); AAV2/1, 1.3% (0.1–2.9%); others, <; 1% transgene-expressing PBPC]. In addition, the relevance of the single-to-double-strand conversion block in transduction of human PBPC could be shown using pseudotyped dsAAV vectors: for dsAAV2/2 [9.3% (8.3–20.3%); P < 0.001] and dsAAV2/6 [37.7% (23.6–61.0%); P < 0.001) significantly more PBPC expressed the transgene compared with their single-stranded counterparts; for dsAAV2/1, no significant increase could be observed.ConclusionsWe have shown that clinically relevant transduction efficiency levels using AAV-based vectors in human CD34+ PBPC are feasible, thereby offering an efficient alternative vector system for gene transfer into this important target cell population.  相似文献   

13.
PurposeTo quantify the impact of simulated errors for nasopharynx radiotherapy across multiple institutions and planning techniques (auto-plan generated Volumetric Modulated Arc Therapy (ap-VMAT), manually planned VMAT (mp-VMAT) and manually planned step and shoot Intensity Modulated Radiation Therapy (mp-ssIMRT)).MethodsTen patients were retrospectively planned with VMAT according to three institution’s protocols. Within one institution two further treatment plans were generated using differing treatment planning techniques. This resulted in mp-ssIMRT, mp-VMAT, and ap-VMAT plans. Introduced treatment errors included Multi Leaf Collimator (MLC) shifts, MLC field size (MLCfs), gantry and collimator errors. A change of more than 5% in most selected dose metrics was considered to have potential clinical impact. The original patient plan total Monitor Units (MUs) were correlated to the total number of dose metrics exceeded.ResultsThe impact of different errors was consistent, with ap-VMAT plans (two institutions) showing larger dose deviations than mp-VMAT created plans (one institution). Across all institutions’ VMAT plans the significant errors included; ±5° for the collimator angle, ±5 mm for the MLC shift and +1, ±2 and ±5 mm for the MLC field size. The total number of dose metrics exceeding tolerance was positively correlated to the VMAT total plan MUs (r = 0.51, p < 0.001), across all institutions and techniques.ConclusionsDifferences in VMAT robustness to simulated errors across institutions occurred due to planning method differences. Whilst ap-VMAT was most sensitive to MLC errors, it also produced the best quality treatment plans. Mp-ssIMRT was most robust to errors. Higher VMAT treatment plan complexity led to less robust plans.  相似文献   

14.
The success of vascular stents in the restoration of blood flow is limited by restenosis. Recent data generated from computational fluid dynamics (CFD) models suggest that stent geometry may cause local alterations in wall shear stress (WSS) that have been associated with neointimal hyperplasia and subsequent restenosis. However, previous CFD studies have ignored histological evidence of vascular straightening between circumferential stent struts. We tested the hypothesis that consideration of stent-induced vascular deformation may more accurately predict alterations in indexes of WSS that may subsequently account for histological findings after stenting. We further tested the hypothesis that the severity of these alterations in WSS varies with the degree of vascular deformation after implantation. Steady-state and time-dependent simulations of three-dimensional CFD arteries based on canine coronary artery measurements of diameter and blood flow were conducted, and WSS and WSS gradients were calculated. Circumferential straightening introduced areas of high WSS between stent struts that were absent in stented vessels of circular cross section. The area of vessel exposed to low WSS was dependent on the degree of circumferential vascular deformation and axial location within the stent. Stents with four vs. eight struts increased the intrastrut area of low WSS in vessels, regardless of cross-sectional geometry. Elevated WSS gradients were also observed between struts in vessels with polygonal cross sections. The results obtained using three-dimensional CFD models suggest that changes in vascular geometry after stent implantation are important determinants of WSS distributions that may be associated with subsequent neointimal hyperplasia.  相似文献   

15.
Summary To study the effect of haemodynamic stress on the morphological differentiation of pseudointima, the ultrastructure of the cells lining normally shaped and aneurysmal polyurethane vascular prostheses implanted into the abdominal aorta of rats was examined. In the normally shaped vascular prostheses the pseudointima was composed of several layers of smooth muscle cells, which varied in differentiation from normal smooth muscle cells to myofibroblasts, and which were lined by a continuous sheet of endothelial cells. In the aneurysmal vascular prostheses, a pseudointima, composed of only layers of smooth muscle cells had developed. Those smooth muscle cells which lined the lumen had a typical morphology: they were polygonal, flat cells of unequal size, with a distinct organelle-free zone, containing myofilaments, at the luminal peripheral cytoplasmic side. The other smooth muscle cells varied in differentiation from normal smooth muscle cells to myofibroblasts. Under severe haemodynamic stresses, such as occur in the aneurysmal vascular prostheses, the regeneration of endothelial cells is impaired and smooth muscle cells undergo morphological changes to form a pseudoendothelial lining.  相似文献   

16.
This study aimed to examine within-day and between-days intratester reliability of mechanomyography (MMG) in assessing muscle fatigue. An accelerometer was used to detect the MMG signal from rectus femoris. Thirty one healthy subjects (15 males) with no prior knee problems initially performed three maximum voluntary contractions (MVCs) using an ISOCOM dynamometer. After 10 min rest, subjects performed a fatiguing protocol in which they performed three isometric knee extensions at 75% MVC for 40 s. The fatiguing protocol was repeated on two other days, two to four days apart for between-days reliability. MMG activity was determined by overall root mean squared amplitude (RMS), mean power frequency (MPF) and median frequency (MF) during a 40 s contraction. RMS, MPF and MF linear regression slopes were also analysed. Intraclass Correlation Coefficients (ICC); ICC1,1 and ICC1,2 were used to assess within-day reliability and between-days reliability respectively. Standard error of measurement (SEM) and smallest detectable difference (SDD) described the within-subjects variability. MMG fatigue measures using linear regression slopes showed low reliability and large between-days error (ICC1,2 = 0.43–0.46; SDD = 306.0–324.8% for MPF and MF slopes respectively). Overall MPF and MF, on the other hand, were reliable with high ICCs and lower SDDs compared to linear slopes (ICC1,2 = 0.79–0.83; SDD = 21.9–22.8% for MPF and MF respectively). ICC1,2 for overall MMG RMS and linear RMS slopes were 0.81 and 0.66 respectively; however, the SDDs were high (56.4% and 268.8% respectively). The poor between-days reliability found in this study suggests caution in using MMG RMS, MPF and MF and their corresponding slopes in assessing muscle fatigue.  相似文献   

17.
In the present study, the aphrodisiac activity of Butea frondonsa Koen. ex Roxb (Papillionaceae) bark extract was investigated. The extract (400 mg/kg body wt./day) was administered orally by gavage for 28 days. Mount latency (ML), intromission latency (IL), ejaculation latency (EL), mounting frequency (MF), intromission frequency (IF), ejaculation frequency (EF) and post-ejaculatory interval (PEI) were the parameters observed before and during the sexual behavior study at day 0, 7, 10, 14, 21, and 28. The extract reduced significantly ML, IL, EL and PEI (p < 0.05). The extract also increased significantly MF, IF and EF (p < 0.05). These effects were observed in sexually active and inactive male rats.  相似文献   

18.

Introduction  

The success of vascular stents in the restoration of blood flow is limited by restenosis. Recent data generated from computational fluid dynamics (CFD) models suggest that the vascular geometry created by an implanted stent causes local alterations in wall shear stress (WSS) that are associated with neointimal hyperplasia (NH). Foreshortening is a potential limitation of stent design that may affect stent performance and the rate of restenosis. The angle created between axially aligned stent struts and the principal direction of blood flow varies with the degree to which the stent foreshortens after implantation.  相似文献   

19.
This study investigates the mitochondrial (mt) distribution in canine ovarian oocytes examined at recovery time, as related to the reproductive cycle stage, and in oviductal oocytes. Ovarian Germinal Vesicle (GV) stage oocytes were recovered from bitches in anestrous (A, n = 2), follicular phase (F, n = 4), ovulation (O, n = 2), early luteal (EL, n = 7) and mid/late luteal phase (MLL, n = 2). Oviductal GV, metaphase I (MI) or MII stage oocytes were recovered from six bitches between 56 and 110 h after ovulation. Mitochondria were revealed by using MitoTracker Orange CMTM Ros and confocal microscopy. In ovarian oocytes, three mt distribution patterns were found: (I) small aggregates diffused throughout the cytoplasm; (II) diffused tubular networks; (III) pericortical tubular networks. Significantly higher rates of oocytes showing heterogeneous mt patterns (II + III) were obtained from bitches in F (75%) and in O (96%) compared with bitches in A (31%; F vs. A: P < 0.05; O vs. A: P < 0.001), in EL (61%; O vs. EL: P < 0.01), or in MLL (0%; F vs. MLL: P < 0.05; O vs. MLL: P < 0.001). Fluorescence intensity did not vary according to mt distribution pattern except that it was lower in oocytes recovered in EL phase and showing small mt aggregations (P < 0.001). The majority of ovulated MII stage oocytes (79%) showed diffused tubular mt network. We conclude that mt distribution pattern of canine ovarian immature oocytes changes in relation to reproductive cycle stage and that patterns observed in oocytes recovered from bitches in periovulatory phases are heterogeneous and similar to those of in vivo matured oocytes.  相似文献   

20.
An aortic dissection (AD) is a serious condition defined by the splitting of the arterial wall, thus generating a secondary lumen [the false lumen (FL)]. Its management, treatment and follow-up are clinical challenges due to the progressive aortic dilatation and potentially severe complications during follow-up. It is well known that the direction and rate of dilatation of the artery wall depend on haemodynamic parameters such as the local velocity profiles, intra-luminal pressures and resultant wall stresses. These factors act on the FL and true lumen, triggering remodelling and clinical worsening. In this study, we aimed to validate a computational fluid dynamic (CFD) tool for the haemodynamic characterisation of chronic (type B) ADs. We validated the numerical results, for several dissection geometries, with experimental data obtained from a previous in vitro study performed on idealised dissected physical models. We found a good correlation between CFD simulations and experimental measurements as long as the tear size was large enough so that the effect of the wall compliance was negligible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号