The pelvis functions to transmit upper body loads to the lower limbs and is critical in human locomotion. Semi-automated, landmark-based finite element (FE) morphing and mapping techniques eliminate the need for segmentation and have shown to accelerate the generation of multiple specimen-specific pelvic FE models to enable the study of pelvic mechanical behaviour. The purpose of this research was to produce an experimentally validated cohort of specimen-specific FE models of the human pelvis and to use this cohort to analyze pelvic strain patterns during gait. Using an initially segmented specimen-specific pelvic FE model as a source model, four more specimen-specific pelvic FE models were generated from target clinical CT scans using landmark-based morphing and mapping techniques. FE strains from the five models were compared to the experimental strains obtained from cadaveric testing via linear regression analysis, (R2 values ranging from 0.70 to 0.93). Inter-specimen variability in FE strain distributions was seen among the five specimen-specific pelvic FE models. The validated cohort of specimen-specific pelvic FE models was utilized to examine pelvic strains at different phases of the gait cycle. Each validated specimen-specific FE model was reconfigured into gait cycle phases representing heel-strike/heel-off and midstance/midswing. No significant difference was found in the double-leg stance and heel-strike/heel-off models (p = 0.40). A trend was observed between double-leg stance and midstance/midswing models (p = 0.07), and a significant difference was found between heel-strike/heel-off models and midstance/midswing models (p = 0.02). Significant differences were also found in comparing right vs. left models (heel-strike/heel-off p = 0.14, midstance/midswing p = 0.04).  相似文献   

2.
Statistical shape analysis was conducted on 15 pairs (left and right) of human kidneys. It was shown that the left and right kidney were significantly different in size and shape. In addition, several common modes of kidney variation were identified using statistical shape analysis. Semi-automatic mesh morphing techniques have been developed to efficiently create subject specific meshes from a template mesh with a similar geometry. Subject specific meshes as well as probabilistic kidney meshes were created from a template mesh. Mesh quality remained about the same as the template mesh while only taking a fraction of the time to create the mesh from scratch or morph with manually identified landmarks. This technique can help enhance the quality of information gathered from experimental testing with subject specific meshes as well as help to more efficiently predict injury by creating models with the mean shape as well as models at the extremes for each principal component.  相似文献   

3.
The purpose of this study was to determine whether modifying an existing, highly biofidelic full body finite element model [total human model for safety (THUMS)] would produce valid amplitude and temporal shock wave characteristics as it travels proximally through the lower extremity. Modifying an existing model may be more feasible than developing a new model, in terms of cost, labour and expertise. The THUMS shoe was modified to more closely simulate the material properties of a heel pad. Relative errors in force and acceleration data from experimental human pendulum impacts and simulated THUMS impacts were 22% and 54%, respectively, across the time history studied. The THUMS peak acceleration was attenuated by 57.5% and took 19.7 ms to travel proximally along the lower extremity. Although refinements may be necessary to improve force and acceleration timing, the modified THUMS represented, to a certain extent, shock wave propagation and attenuation demonstrated by living humans under controlled impact conditions.  相似文献   

4.
5.
Total knee arthroplasty (TKA) is a successful procedure for osteoarthritis. However, some patients (19%) do have pain after surgery. A finite element model was developed based on boundary conditions of a knee rig. A 3D-model of an anatomical full leg was generated from magnetic resonance image data and a total knee prosthesis was implanted without patella resurfacing. In the finite element model, a restarting procedure was programmed in order to hold the ground reaction force constant with an adapted quadriceps muscle force during a squat from 20° to 105° of flexion. Knee rig experimental data were used to validate the numerical model in the patellofemoral and femorotibial joint. Furthermore, sensitivity analyses of Young’s modulus of the patella cartilage, posterior cruciate ligament (PCL) stiffness, and patella tendon origin were performed. Pearson’s correlations for retropatellar contact area, pressure, patella flexion, and femorotibial ap-movement were near to 1. Lowest root mean square error for retropatellar pressure, patella flexion, and femorotibial ap-movement were found for the baseline model setup with Young’s modulus of 5 MPa for patella cartilage, a downscaled PCL stiffness of 25% compared to the literature given value and an anatomical origin of the patella tendon. The results of the conducted finite element model are comparable with the experimental results. Therefore, the finite element model developed in this study can be used for further clinical investigations and will help to better understand the clinical aspects after TKA with an unresurfaced patella.  相似文献   

6.
This article introduces a new approach for the construction of a risk model for the prediction of Traumatic Brain Injury (TBI) as a result of a car crash. The probability of TBI is assessed through the fusion of an experiment-based logistic regression risk model and a finite element (FE) simulation-based risk model. The proposed approach uses a multilevel framework which includes FE simulations of vehicle crashes with dummy and FE simulations of the human brain. The loading conditions derived from the crash simulations are transferred to the brain model thus allowing the calculation of injury metrics such as the Cumulative Strain Damage Measure (CSDM). The framework is used to propagate uncertainties and obtain probabilities of TBI based on the CSDM injury metric. The risk model from FE simulations is constructed from a support vector machine classifier, adaptive sampling, and Monte-Carlo simulations. An approach to compute the total probability of TBI, which combines the FE-based risk assessment as well as the risk prediction from the experiment-based logistic regression model is proposed. In contrast to previous published work, the proposed methodology includes the uncertainty of explicit parameters such as impact conditions (e.g., velocity, impact angle), and material properties of the brain model. This risk model can provide, for instance, the probability of TBI for a given assumed crash impact velocity.  相似文献   

7.
Computational biomechanics for human body modeling has generally been categorized into two separated domains: finite element analysis and multibody dynamics. Combining the advantages of both domains is necessary when tissue stress and physical body motion are both of interest. However, the method for this topic is still in exploration. The aim of this study is to implement unique controlling strategies in finite element model for simultaneously simulating musculoskeletal body dynamics and in vivo stress inside human tissues. A finite element lower limb model with 3D active muscles was selected for the implementation of controlling strategies, which was further validated against in-vivo human motion experiments. A unique feedback control strategy that couples together a basic Proportion-Integration-Differentiation (PID) controller and generic active signals from Computed Muscle Control (CMC) method of the musculoskeletal model or normalized EMG singles was proposed and applied in the present model. The results show that the new proposed controlling strategy show a good correlation with experimental test data of the normal gait considering joint kinematics, while stress distribution of local lower limb tissue can be also detected in real-time with lower limb motion. In summary, the present work is the first step for the application of active controlling strategy in the finite element model for concurrent simulation of both body dynamics and tissue stress. In the future, the present method can be further developed to apply it in various fields for human biomechanical analysis to monitor local stress and strain distribution by simultaneously simulating human locomotion.  相似文献   