首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A number of studies have been published that have used variables of the electromyogram (EMG) power spectrum during dynamic exercise. Despite these studies there is a shortage of studies of the validity of surface EMG registrations during repetitive dynamic contractions with respect to fatigue. The aim of this study was to investigate if the surface EMG variables mean frequency (MNF [Hz]) and the signal amplitude (RMS [microV]) are valid indicators of muscular fatigue (defined as "any exercise-induced reduction in the capacity to generate force or power output") during maximum repeated isokinetic knee extensions (i.e. criterion validity using peak torque). Twenty-one healthy volunteers performed 100 isokinetic knee extensions at 90 degrees s(-1). EMG signals were recorded from the vastus lateralis, the rectus femoris and the vastus medialis of the right thigh by surface electrodes. MNF and RMS of the EMG together with peak torque (PT [Nm]) were determined for each contraction. MNF showed consequently higher correlation coefficients with PT than RMS did. Positive correlations generally existed between MNF and PT. The majority of the subjects had positive correlations between RMS and PT (i.e. decreases both in PT and in RMS).In conclusion, at the individual level MNF generally - in contrast to RMS - showed good criterion validity with respect to biomechanical fatigue during dynamic maximum contractions.  相似文献   

2.
The aim of this study was to investigate the reliability of peak torque and surface electromyography (EMG) variable's root mean square (RMS) and mean frequency (MNF) during an endurance test consisting of repetitive maximum concentric knee extensions. Muscle fatigue has been quantified in several ways, and in isokinetic testing it is based on a set of repetitive contractions. To assess test-retest reliability, two sets of 100 dynamic maximum concentric knee extensions were performed using an isokinetic dynamometer. The two series were separated by 7-8 days. The subjects relaxed during the passive flexion phase. Twenty (10 men and 10 women) clinically healthy subjects volunteered.Peak torque and EMG from rectus femoris, vastus medialis, vastus lateralis and biceps femoris were recorded. RMS and MNF were calculated from the EMG signal. The reliability was calculated with intraclass correlation coefficient ICC (1.1) and standard error of measurements (SEM). The reliability of peak torque was good (ICC=0.93) and SEM showed low values. ICC was good for absolute RMS of rectus femoris (ICC>/=0.80), vastus medialis (ICC>/=0.88) and vastus lateralis (ICC>/=0.82) and MNF of rectus femoris (ICC>/=0.82) and vastus medialis (ICC>/=0.83). Peak torque, and MNF and RMS of rectus femoris and vastus medialis are reliable variables obtained from an isokinetic endurance test of the knee extensors.  相似文献   

3.
The purpose of this study was to compare the electromyographic (EMG) amplitudes of the quadriceps femoris (QF) muscles during a maximum voluntary isometric contraction (MVIC) to submaximal and maximal dynamic concentric contractions during active exercises. A secondary purpose was to provide information about the type of contraction that may be most appropriate for normalization of EMG data if one wants to determine if a lower extremity closed chain exercise is of sufficient intensity to produce a strengthening response for the QF muscles. Sixty-eight young healthy volunteers (39 female, 29 male) with no lower extremity pain or injury participated in the study. Surface electrodes recorded EMG amplitudes from the vastus medialis obliquus (VMO), rectus femoris (RF), and vastus lateralis (VL) muscles during 5 different isometric and dynamic concentric exercises. The last 27 subjects performed an additional 4 exercises from which a second data set could be analyzed. Maximum isokinetic knee extension and moderate to maximum closed chain exercises activated the QF significantly more than a MVIC. A 40-cm. lateral step-up exercise produced EMG amplitudes of the QF muscles of similar magnitude as the maximum isokinetic knee extension exercises and would be an exercise that could be considered for strengthening the QF muscles. Most published EMG studies of exercises for the QF have been performed by comparing EMG amplitudes during dynamic exercises to a MVIC. This procedure can lead one to overestimate the value of a dynamic exercise for strengthening the QF muscles. We suggest that when studying the efficacy of a dynamic closed chain exercise for strengthening the QF muscles, the exercise be normalized to a dynamic maximum muscle contraction such as that obtained with knee extension during isokinetic testing.  相似文献   

4.
Frequency analysis of myoelectric (ME) signals, using the mean power spectral frequency (MNF), has been widely used to characterize peripheral muscle fatigue during isometric contractions assuming constant force. However, during repetitive isokinetic contractions performed with maximum effort, output (force or torque) will decrease markedly during the initial 40-60 contractions, followed by a phase with little or no change. MNF shows a similar pattern. In situations where there exist a significant relationship between MNF and output, part of the decrease in MNF may per se be related to the decrease in force during dynamic contractions. This study estimated force effects on the MNF shifts during repetitive dynamic knee extensions. Twenty healthy volunteers participated in the study and both surface ME signals (from the right vastus lateralis, vastus medialis, and rectus femoris muscles) and the biomechanical signals (force, position, and velocity) of an isokinetic dynamometer were measured. Two tests were performed: (i) 100 repetitive maximum isokinetic contractions of the right knee extensors, and (ii) five gradually increasing static knee extensions before and after (i). The corresponding ME signal time-frequency representations were calculated using the continuous wavelet transform. Compensation of the MNF variables of the repetitive contractions was performed with respect to the individual MNF-force relation based on an average of five gradually increasing contractions. Whether or not compensation was necessary was based on the shape of the MNF-force relationship. A significant compensation of the MNF was found for the repetitive isokinetic contractions. In conclusion, when investigating maximum dynamic contractions, decreases in MNF can be due to mechanisms similar to those found during sustained static contractions (force-independent component of fatigue) and in some subjects due to a direct effect of the change in force (force-dependent component of fatigue). In order to compare MNF shifts during sustained static and repetitive dynamic contractions it is necessary to estimate the force-dependent component of fatigue of dynamic contractions. Our results are preliminary and have to be confirmed in larger experiments using single dynamic contractions when determining the MNF-force relationship of the unfatigued situation.  相似文献   

5.
The continuous wavelet transform (CWT), a time-frequency method, was used when calculating mean frequency of the power spectrum (MNF) and signal amplitude (RMS) of the surface EMG to investigate their relationships to force during a gradually increasing knee extension (ramp). Based upon the CWT, MNF was redefined to include time dependence on the EMG signal frequency contents, the short-time MNF (STMNF). Surface EMG was recorded from vastus lateralis, rectus femoris and vastus medialis in 21 clinically healthy subjects during a brief, gradually increasing contraction up to 100% of a maximum voluntary contraction (MVC), with a duration of approximately 10 s. The relationships between the EMG variables and force using linear regression were determined for each subject. For vastus lateralis, we also investigated if certain aspects of the muscle morphology (i.e., proportions and areas of different fibre types) influenced the EMG-force relationship.For the majority of subjects (17-18 out of 21 subjects) there were significant positive correlations between STMNF and force in the three muscles. No sex differences were found in intercepts or regression coefficients of STMNF. The muscle morphology had a significant influence on the STMNF-force intercept and the regression coefficient. Positive and highly significant linear correlations between RMS and force were found for all subjects and all three muscles.In conclusion, time frequency methods can be applied when investigating EMG during brief contractions associated with non-stationarity. In a great majority of the subjects, and in the three muscles, significant linear force dependencies were found for STMNF. Thus, when evaluating muscle fatigue, e.g., in ergonomic situations, it is important to consider the force level as one factor that can influence the results. Morphological variables (fibre proportions and fibre areas) influenced the STMNF-force relationship in vastus lateralis.  相似文献   

6.
This study was designed to determine trial-to-trial and day-to-day reproducibility of isometric force and electromyogram activity (EMG) of the knee extensor muscles in water and on dry land as well as to make comparisons between the two training conditions in muscle activity and force production. A group of 20 healthy subjects (12 women and 8 men) were tested three times over 2 weeks. A measurement session consisted of recordings of maximal and submaximal isometric knee extension force with simultaneous recording of surface EMG from the vastus medialis, vastus lateralis and biceps femoris muscles. To ensure identical measurement conditions the same patient elevator chair was used in both the dry and the wet environment. Intraclass correlation coefficients (ICC) and coefficients of variation (CV) showed high trial-to-trial (ICC = 0.95-0.99, CV = 3.5%-11%) and day-to-day reproducibility (ICC=0.85-0.98, CV=11%-19%) for underwater and dry land measurements of force and EMG in each muscle during maximal contractions. The day-to-day reproducibility for submaximal contractions was similar. The interesting finding was that underwater EMG amplitude decreased significantly in each muscle during maximal (P < 0.01-P < 0.001) and submaximal contractions (P < 0.05-P < 0.001). However, the isometric force measurements showed similar values in both wet and dry conditions. The water had no disturbing effect on the electrodes as shown by slightly lowered interelectrode resistance values, the absence of artefacts and low noise levels of the EMG signals. It was concluded that underwater force and EMG measurements are highly reproducible. The significant decrease of underwater EMG could have electromechanical and/or neurophysiological explanations.  相似文献   

7.
The repeatability of initial values and rate of change of EMG signal mean spectral frequency (MNF), average rectified values (ARV), muscle fiber conduction velocity (CV) and maximal voluntary contraction (MVC) was investigated in the vastus medialis obliquus (VMO) and vastus lateralis (VL) muscles of both legs of nine healthy male subjects during voluntary, isometric contractions sustained for 50 s at 50% MVC. The values of MVC were recorded for both legs three times on each day and for three subsequent days, while the EMG signals have been recorded twice a day for three subsequent days. The degree of repeatability was investigated using the Fisher test based upon the ANalysis Of VAriance (ANOVA), the Standard Error of the Mean (SEM) and the Intraclass Correlation Coefficient (ICC).

Data collected showed a high level of repeatability of MVC measurement (normalized SEM from 1.1% to 6.4% of the mean). MNF and ARV initial values also showed a high level of repeatability (ICC>70% for all muscles and legs except right VMO). At 50% MVC level no relevant pattern of fatigue was observed for the VMO and VL muscles, suggesting that other portions of the quadriceps might have contributed to the generated effort. These observations seem to suggest that in the investigation of muscles belonging to a multi-muscular group at submaximal level, the more selective electrically elicited contractions should be preferred to voluntary contractions.  相似文献   


8.
The clinical application of EMG requires that the recorded signal is representative of the muscle of interest and is not contaminated with signals from adjacent muscles. Some authors report that surface EMG is not suitable for obtaining information on a single muscle but rather reflects muscle group function [J. Perry, C.S. Easterday, D.J. Antonelli, Surface versus intramuscular electrodes for electromyography of superficial and deep muscles. Physical Therapy 61 (1981) 7–15]. Other authors report however, that surface EMG is adequate to determine individual muscle function, once guidelines pertaining to data acquisition are followed [D.A. Winter, A.J. Fuglevand, S.E. Archer. Cross-talk in surface electromyography: theoretical and practical estimates. Journal of Electromyography and Kinesiology 4 (1994) 15–26]. The aim of this study was to determine whether surface EMG was suitable for monitoring rectus femoris (RF) activity during static contractions. Five healthy subjects, having given written informed consent, participated in this trial. Surface and fine wire EMG from the rectus femoris and the vastus lateralis (VL) muscles were recorded simultaneously during a protocol of static contractions consisting of knee extensions and hip flexions. Ratios were used to quantify the relationship between the surface EMG amplitude value and the fine wire EMG amplitude value for the same contraction. The results showed that hip flexion contractions elicited RF activation only and that knee extension contractions elicited fine wire activity in VL only. When the relationship between RF surface and RF fine wire electrodes was compared for hip flexion and knee extension contractions, it was observed that for all subjects, there was a tendency for increased RF surface activity in the absence of RF fine wire activity during knee extensions. It was concluded that the activity recorded by the RF surface electrode arrangement during knee extension consisted of EMG from the vastii, i.e., cross-talk and that vastus intermedius was the most likely origin of the erroneous signal. Therefore it is concluded that for accurate EMG information from RF, fine wire electrodes are necessary during a range of static contractions.  相似文献   

9.
The purpose of this study was to determine the effect of gender on changes in electromyographic (EMG) signal characteristics of the quadriceps muscles with increasing force and with fatigue. A total of fourteen healthy adults (seven men, seven women) participated in the study. Subjects had to perform isometric ramp contractions in knee extension with the force gradually increasing from 0 to 100% of the maximal voluntary contraction (MVC) in a 6-s period. Subjects then performed a fatigue task, consisting of a sustained maximum isometric knee extension contraction held until force decreased below 50% of the pre-fatigue MVC. Subjects also performed a single ramp contraction immediately after the fatigue task. The Root Mean Square (RMS) amplitude, mean power frequency (MPF) and median frequency (MF) of EMG signals obtained from the vastus lateralis, vastus medialis and rectus femoris were calculated at nine different force levels from the ramp contractions (10, 20, 30, 40, 50, 60, 70, 80 and 90% MVC), as well as every 5 s during the fatigue task. The main results were a more pronounced increase in EMG RMS amplitude for the three muscles and in MPF for the VL muscle with force in men compared with women. No significant effect of gender was found with regards to fatigue. These observations most likely reflect a moderately greater type II fiber content and/or area in the VL muscle of men compared to that of women.  相似文献   

10.
AIM: This study examined the electromyographic (EMG) activity of knee extensor agonists and a knee extensor antagonist muscle during fatiguing isometric extensions across a range of force levels. METHODS: Five female subjects performed isometric knee extensions at 25%, 50%, 75% and 100% of their maximal voluntary contraction (MVC) with the knee flexed to 75 degrees. Surface EMG (SEMG) was recorded with bipolar electrodes from the vastus lateralis (VL), vastus medialis (VM), rectus femoris (RF) and biceps femoris (BF) and the root-mean-squared (RMS) amplitude and the percentage frequency compression of these recordings were calculated. Commonality and cross talk between recordings were also examined. RESULTS: Cross talk between recordings was deemed negligible despite significant levels of commonality between the agonist and antagonist SEMG, which was attributed to common drive. SEMG RMS amplitude increased significantly for all muscles during the 25%, 50%, 75% MVC knee extensions until task failure, and decreased significantly for 100% MVC. The frequency spectrum of the SEMG compressed significantly for all muscles and % MVC levels. The VM, VL and BF SEMG recordings responded similarly to fatigue. The RF's frequency spectrum compressed to a significantly higher degree. CONCLUSIONS: The VM, VL, RF, and BF fatigue in parallel, with high similarity between VM, VL and BF, giving support to the concept of a shared agonist-antagonist motoneuron pool.  相似文献   

11.
The purpose of this study was to examine the responses of peak torque (PT), mean power output (MP), mechanomyographic (MMG) and electromyographic (EMG) amplitudes, and mean power frequencies (MPFs) of the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) in men and women during dynamic muscle actions. Twelve women (mean +/- SD age = 22 +/- 3 years) and 11 men (22 +/- 3 years) performed maximal, concentric, isokinetic leg extensions at velocities of 60, 120, 180, 240, and 300 degrees x s(-1) on a Cybex 6000 dynamometer. Piezoelectric MMG-recording sensors and bipolar surface EMG electrodes were placed over the VL, RF, and VM muscles. No sex-related differences were found among the velocity-related patterns for PT, MP, MMG amplitude, MMG MPF, or EMG MPF. There were, however, sex-related differences in the patterns of EMG amplitude across velocity. The results indicated similar velocity-related patterns of increase of MP and MMG amplitude for all 3 muscles and of EMG amplitude for the VL and VM in the women. Velocity-related decreases (p 0.05) across velocity. MMG MPF increased (p < or = 0.05) only between 240 and 300 degrees x s(-1). Overall, these findings suggested that there were sex- and muscle-specific, velocity-related differences in the associations among motor unit activation strategies (EMG amplitude and MPF) and the mechanical aspects of muscular activity (MMG amplitude and MPF). With additional examination and validation, however, MMG may prove useful to practitioners for monitoring training-induced changes in muscle power output.  相似文献   

12.
The purpose of this study was to evaluate gender and muscle differences in electromyographic (EMG) amplitude and median frequency mean and standard deviation during maximal voluntary contractions of the quadriceps femoris. Thirty recreationally active volunteers were assessed for isometric EMG activity of the vastus medialis (VM), vastus lateralis (VL), and rectus femoris (RF) muscles during three 5-s maximal isometric voluntary contractions (MVCs). Median frequency of the three muscles was assessed through a power spectral analysis (fast Fourier transformation, Hanning window processing, 512 points). The power spectral analysis was performed during the middle 3 s of each contraction over 11 consecutive, 512 ms epochs overlapping each other by half their length (256 ms). The median frequency (F(med)) for each of the 11 windows was determined for each muscle. The mean and standard deviation of the F(med) across the 11 overlapping windows were then calculated for each contraction and muscle. EMG amplitude was determined by calculating the root mean square (RMS-50 ms time constant) over the same contraction period for each muscle. The mean amplitude and standard deviation about the mean value were then determined. A three-factor ANOVA with repeated measures was performed on the calculated F(med) mean and standard deviation values, and RMS standard deviations, to assess any gender, muscle, or trial differences, or interactions. A two-factor (gender by muscle) ANOVA with repeated measures was performed on the RMS mean amplitude for each muscle. Intraclass correlation coefficients (ICCs-2,1), standard errors of measurement (SEMs), and associated 95% confidence intervals were then calculated for maximal quadriceps torque and F(med) for each muscle. The results from this study demonstrated that the VL muscle displayed significantly higher F(med) values than the RF and VM muscles. The RF muscle showed significantly higher F(med) values (mean of 11 overlapping windows) than the VM muscle. Intrasession reliability was found to be high for the calculated mean values (ICC=0.85-0.96), but was shown to be low for variability (ICC=0.13-0.45). The major findings of this study support the notion that the EMG signal is "quasi-random" in nature, as demonstrated by the reproducible F(med) means and unreliable variability.  相似文献   

13.
The purpose of this study was to determine test-retest reliability for median frequency (MDF) and amplitude of surface EMG during sustained fatiguing contractions of the quadriceps. Twenty-two healthy subjects (11 males and 11 females) were tested on two days held one week apart. Surface EMG was recorded from rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM) during sustained isometric contractions at 80% and 20% of maximal voluntary contraction (MVC) held to exhaustion. Quadriceps fatigue was described using four measures for both MDF and amplitude of EMG: initial, final, normalized final and slope. For both MDF and amplitude, the initial, final and normalized EMG showed moderate to high reliability for all three muscle groups at both contraction levels (ICC=0.59-0.88 for MDF; ICC=0.58-0.99 for amplitude). Slope of MDF and amplitude was associated with a large degree of variability and low ICCs for the 80% but not the 20% MVC. MDF and amplitude of EMG during sustained contractions of the quadriceps are reproducible; normalized final values of MDF and amplitude show better reliability than slope.  相似文献   

14.
The objective of this study was to examine the superficial quadriceps femoris (QF) muscle electromyogram (EMG) during fatiguing knee extensions. Thirty young adults were evaluated for their one-repetition maximum (1RM) during a seated, right-leg, inertial knee extension. All subjects then completed a single set of repeated knee extensions at 50% 1RM, to failure. Subjects performed a knee extension (concentric phase), held the weight with the knee extended for 2s (isometric phase), and lowered the weight in a controlled manner (eccentric phase). Raw EMG of the vastus medialis (VM), vastus lateralis (VL) and rectus femoris (RF) muscles were full-wave rectified, integrated and normalized to the 1RM EMG, for each respective phase and repetition. The EMG median frequency (f(med)) was computed during the isometric phase. An increase in QF muscle EMG was observed during the concentric phase across the exercise duration. VL EMG was greater than the VM and RF muscles during the isometric phase, in which no significant changes occurred in any of the muscles across the exercise duration. A significant decrease in EMG across the exercise duration was observed during the eccentric phase, with the VL EMG greater than the VM and RF muscles. A greater decrease in VL and RF muscle f(med) during the isometric phase, than the VM muscle, was observed with no gender differences. The findings demonstrated differential recruitment of the superficial QF muscle, depending on the contraction mode during dynamic knee extension exercise, where VL muscle dominance appears to manifest across the concentric-isometric-eccentric transition.  相似文献   

15.
The purpose of this study was to determine whether surface electromyography (EMG) assessment of myoelectric manifestations of muscle fatigue is capable of detecting differences between the vastus lateralis and medialis muscles which are consistent with the results of previous biopsy studies. Surface EMG signals were recorded from the vastus medialis longus (VML), vastus medialis obliquus (VMO) and vastus lateralis (VL) muscles during isometric knee extension contractions at 60% and 80% of the maximum voluntary contraction (MVC) for 10 s and 60 s, respectively. Initial values and rate of change of mean frequency (MNF), average rectified value (ARV) and conduction velocity (CV) of the EMG signal were calculated. Comparisons between the two force levels revealed that the initial values of MNF for the VL muscle were greater at 80% MVC compared to 60% MVC (P < 0.01). Comparisons between the vasti muscles demonstrated lower initial values of CV for VMO compared to VL at 60% MVC (P < 0.01) and lower than VML and VL at 80% MVC (P < 0.01). In addition, initial values of MNF were higher for VL with respect to both VML and VMO at 80% MVC (P < 0.01) and initial estimates of ARV were higher for VMO compared to VML at both force levels (P < 0.01 at 60% MVC and P < 0.05 at 80% MVC). For the sustained contraction at 80% MVC, VL demonstrated a greater decrease in CV over time compared to VMO (P < 0.05).These findings suggest that surface EMG signals and their time course during sustained isometric contractions may be useful to non-invasively describe functional differences between the vasti muscles.  相似文献   

16.
Electromyography (EMG) is the standard modality for measuring muscle activity. However, the convenience and availability of low-cost accelerometer-based wearables makes mechanomyography (MMG) an increasingly attractive alternative modality for clinical applications. Literature to date has demonstrated a strong association between EMG and MMG temporal alignment in isometric and isokinetic contractions. However, the EMG-MMG relationship has not been studied in gait. In this study, the concurrence of EMG- and MMG-detected contractions in the tibialis anterior, lateral gastrocnemius, vastus lateralis, and biceps femoris muscles were investigated in children during self-paced gait. Furthermore, the distribution of signal power over the gait cycle was statistically compared between EMG-MMG modalities. With EMG as the reference, muscular contractions were detected based on MMG with balanced accuracies between 88 and 94% for all muscles except the gastrocnemius. MMG signal power differed from that of EMG during certain phases of the gait cycle in all muscles except the biceps femoris. These timing and power distribution differences between the two modalities may in part be related to muscle fascicle length changes that are unique to muscle motion during gait. Our findings suggest that the relationship between EMG and MMG appears to be more complex during gait than in isometric and isokinetic contractions.  相似文献   

17.
The aim of this study was to examine the time-of-day (TOD) effects in myoelectric and mechanical properties of muscle during a maximal and prolonged isokinetic exercise. Twelve male subjects were asked to perform 50 maximal voluntary contractions (MVC) of the knee extensor muscles at a constant angular velocity of 2.09 rad . sec(-1), at 06 : 00 and 18 : 00 h. Torque and electromyographic (EMG) parameters were recorded for each contraction, and the ratio between these values was calculated to evaluate variations of the neuromuscular efficiency (NME) with fatigue and with TOD. The results indicated that maximal torque values (T(45)Max) was significantly higher (7.73%) in the evening than in the morning (p<0.003). The diurnal variation in torque decrease was used to define two phases. During the first phase (1st to the 26th repetition), torque values decreased fast and values were higher in the evening than in the morning, and during the second phase (27th to the 50th repetition), torque decreased slightly and reached a floor value that appeared constant with TOD. The EMG parameters (Root Mean Square; RMS) were modified with fatigue, but were not TOD dependent. The NME decrease-significantly with fatigue, showing that peripheral factors were mainly involved in the torque decrease. Furthermore, NME decrease was greater at 18 : 00 than at 06 : 00 h for the vastus medialis (p<0.05) and the vastus lateralis muscles (p<0.002), and this occurred during the first fatigue phase of the exercise. In conclusion, the diurnal variation of the muscle fatigue observed during a maximal and prolonged isokinetic exercise seems to reflect on the muscle, with a greater contractile capacity but a higher fatigability in the evening compared to the morning.  相似文献   

18.
The purpose of this study was to examine the reliability of normalisation methods used in the study of the posterior and posterolateral neck muscles in a group of healthy controls. Six asymptomatic male subjects performed a total of 12 maximum voluntary isometric contractions (MVIC) and 60%-submaximal isometric contractions (60%-MVIC) against the torque arm of an isokinetic dynamometer whilst surface and intramuscular electromyography (EMG) was recorded unilaterally from representative posterior and posterolateral locations. Reliability was calculated using intra-class correlation coefficient (ICC), relative standard error of measurement (%SEM) and relative coefficient of variation (%CV). Maximal torque output was found to be highly reliable in the directions of extension and right lateral bending when the first of three MVIC contractions was excluded. When averaged across contraction direction, high reliability was found for both surface (MVIC: ICC=0.986, %SEM=7.5, %CV=9.2; 60%-MVIC: ICC=0.975, %SEM=10, %CV=13.7) and intramuscular (MVIC: ICC=0.910, %SEM=20, %CV=19.1; 60%-MVIC: ICC=0.952, %SEM=16.5, %CV=13.5) electrodes. Intramuscular electrodes displayed the least reliability in right lateral bending. The use of visual feedback markedly increased the reliability of 60%-MVIC contractions.  相似文献   

19.
The purpose of this study was to examine the effect of graded conditioning contractions of the antagonist knee flexor muscles on the output characteristics of knee extensor muscles in healthy humans. Eight male university students performed maximum isometric contractions of knee extensors, preceded by isometric conditioning contractions of the antagonist knee flexors. The developed force and electromyographic (EMG) amplitudes of the knee extensors after the conditioning contraction were measured and compared with those of simple knee extension without conditioning. The forces of the conditioning flexor contraction were set at three levels: low (20% of maximum voluntary contraction: MVC), moderate (60% of MVC), and high (100% of MVC). The EMG amplitudes of the vastus medialis, vastus lateralis, and rectus femoris muscle were recorded and the root mean square amplitudes were calculated. The strongest enhancement of the extension force was obtained by moderate intensity conditioning contraction (108.95+/-1.87% of simple knee extension), although high intensity conditioning also induced a significant increase (105.41+/-2.69%). Low intensity conditioning did not cause a significant enhancement of the contraction force (103.17+/-2.99%). Similarly, the EMG amplitudes were significantly increased by moderate and/or high conditioning. These results suggest that antagonist conditioning contraction of moderate intensities is sufficient and may be optimal to potentiate knee extensor contraction.  相似文献   

20.
The purpose of this study was to compare different normalization methods of electromyographic (EMG) activity of antagonists during isokinetic eccentric and concentric knee movements. Twelve women performed three maximum knee extensions and flexions isometrically and at isokinetic concentric and eccentric angular velocities of 30 °·s−1, 90 °·s−1, 120 °·s−1 and 150 °·s−1. The EMG activity of the vastus lateralis, rectus femoris, vastus medialis and hamstrings was recorded. The antagonist integrated IEMG values were normalized relative to the EMG of the same muscle during an isometric maximal action (static method). The values were also expressed as a percentage of the EMG activity of the same muscle, at the same angle, angular velocity and muscle action (dynamic method) when the muscle was acting as an agonist. Three-way analysis of variance (ANOVA) designs indicated significantly greater IEMG normalized with the dynamic method compared to the EMG derived using the static method (P < 0.05). These differences were more evident at concentric angular velocities and at the first and last 20 ° of the movement. The present findings demonstrate that the method of normalization significantly influences the conclusions on antagonistic activity during isokinetic maximum voluntary efforts. The dynamic method of normalization is more appropriate because it considers the effects of muscle action, muscle length and angular velocity on antagonist IEMG.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号