首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 101 毫秒
1.
A new type of sol-gel/organic hybrid composite material based on the cross-linking of natural polymer chitosan with (3-aoryloxypropyl) dimethoxymethylsilane was developed for the fabrication of an amperometric H(2)O(2) biosensor. The composite film was used to immobilize horseradish peroxidase (HRP) on a gold disk electrode. The properties of sol-gel/chitosan and sol-gel/chitosan-HRP films have been carefully characterized by atomic force microscopy and Fourier transform infrared. By using fluorescent label, a protein density on sol-gel/chitosan has been calculated to be 3.14 x 10(12) moleculescm(-2). With the aid of catechol mediator, the biosensor had a fast response of less than 2 s with linear range of 5.0 x 10(-9)-1.0 x 10(-7) mol l(-1) and a detection limit of 2 x 10(-9) mol l(-1). Its current response shows a typical Michaelis-Menten mechanism. The apparent Michaelis-Menten constant K(M)(app) is found to be 1.30 micromol l(-1). The activation energy for enzymatic reaction is calculated to be 8.22 kJ mol(-1). The biosensor retained approximately 75% of its original activity after about 60 days of storage in a phosphate buffer at 4 degrees C.  相似文献   

2.
A highly sensitive and selective amperometric hydrogen peroxide (H(2)O(2)) biosensor based on immobilization of hemoglobin (Hb) at multiwalled carbon nanotubes-zinc oxide (MWCNT/ZnO) composite modified glassy carbon electrode (GCE) is reported. ZnO microsponges were electrochemically grown on MWCNT surface by the simple, cost-effective, green, electrochemical method at room temperature. The MWCNT/ZnO/Hb composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E°') of -0.336V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.26s(-1). The developed biosensor showed a very fast response (>2s) toward H(2)O(2) with good sensitivity, wide linear range, and low detection limit of 0.02μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of MWCNT, and good biocompatibility of ZnO. The fabrication method of this biosensor is simple and effective for determination of H(2)O(2) in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery.  相似文献   

3.
The nanocomposite composed of carboxymethyl chitosan (CMCS) and gold nanoparticles was successfully prepared by a novel and in situ process. It was characterized by transmission electron microscopy (TEM) and Fourier transform infrared spectrophotometer (FTIR). The nanocomposite was hydrophilic even in neutral solutions, stable and inherited the properties of the AuNPs and CMCS, which make it biocompatible for enzymes immobilization. HRP, as a model enzyme, was immobilized on the silica sol-gel matrix containing the nanocomposite to construct a novel H(2)O(2) biosensor. The direct electron transfer of HRP was achieved and investigated. The biosensor exhibited a fast amperometric response (5s), a good linear response over a wide range of concentrations from 5.0 x 10(-6) to 1.4 x 10(-3)M, and a low detection limit of 4.01 x 10(-7)M. The apparent Michaelis-Menten constant (K(M)(app)) for the biosensor was 5.7 x 10(-4)M. Good stability and sensitivity were assessed for the biosensor.  相似文献   

4.
A simple and controllable electrodeposition approach was established for one-step construction of hydrogen peroxide (H(2)O(2)) biosensors by in situ formation of chitosan-ionic liquid-horseradish peroxidase (CS-IL-HRP) biocomposite film on electrode surface. A highly porous surface with orderly three-dimensional network was revealed by scanning electron microscopy (SEM) investigation. The biocomposite provided improved conductivity and biocompatible microenvironment. The developed biosensor exhibited a fast amperometric response for the determination of H(2)O(2) and 95% of the steady-state current was obtained within 2s. The linear response of the developed biosensor for the determination of H(2)O(2) ranged from 6.0x10(-7) to 1.6x10(-4)M with a detection limit of 1.5x10(-7)M. Performance of the biosensor was evaluated with respect to possible interferences and a good selectivity was revealed. The fabricated biosensor exhibited high reproducibility and long-time storage stability. The ease of the one-step non-manual technique and the promising feature of biocomposite could serve as a versatile platform for the fabrication of electrochemical biosensors.  相似文献   

5.
Zou Y  Sun LX  Xu F 《Biosensors & bioelectronics》2007,22(11):2669-2674
In this work, a novel route for fabrication polyaniline (PANI)-Prussian Blue (PB) hybrid composites is proposed by the spontaneous redox reaction in the FeCl(3)-K(3)[Fe(CN)(6)] and the aniline solution. With the introduction of multi-walled carbon nanotubes (MWNTs), the PANI-PB/MWNTs system shows synergy between the PANI-PB and MWNTs which amplified the H(2)O(2) sensitivity greatly. A linear range from 8 x1 0(-8) to 1 x 10(-5)M and a high sensitivity 508.1 8 microA microM cm(2) for H(2)O(2) detection are obtained. The composites also show good stability in neutral solution. A glucose biosensor was further constructed by immobilizing glucose oxidase (GOD) with Nafion and glutaraldehyde on the electrode surface. The performance factors influencing the resulted biosensor were studied in detail. The biosensor exhibits excellent response performance to glucose with the linear range from 1 to 11 mM and a detection limit of 0.01 mM. Furthermore, the biosensor shows rapid response, high sensitivity, good reproducibility, long-term stability and freedom of interference from other co-existing electroactive species.  相似文献   

6.
A novel organic-inorganic nanocomposite of methylene blue (MB) and silicon oxide was synthesized and characterized by TEM, FTIR, and UV-vis. The as-prepared material was able to transfer the electron of the MB to electrode and was different from other SiO2 spheres structurally. It can be used as mediator to construct a biosensor with horseradish peroxidase (HRP) coimmobilized in the gelatine matrix and cross-linked with formaldehyde. The resulting biosensor exhibited fast amperometric response and good stability to hydrogen peroxide (H2O2). The linear range for H2O2 determination was from 1 x 10(-5) to 1.2 x 10(-3) M, with a detection limit of 4 x 10(-6) M based on S/N = 3. Moreover, the lifetime is more than 3 months under dry conditions at 4 degrees C.  相似文献   

7.
Xian Y  Hu Y  Liu F  Xian Y  Wang H  Jin L 《Biosensors & bioelectronics》2006,21(10):1996-2000
In this paper, we report a novel glucose biosensor based on composite of Au nanoparticles (NPs)-conductive polyaniline (PANI) nanofibers. Immobilized with glucose oxidase (GOx) and Nafion on the surface of nanocomposite, a sensitive and selective biosensor for glucose was successfully developed by electrochemical oxidation of H2O2. The glucose biosensor shows a linear calibration curve over the range from 1.0x10(-6) to 8.0x10(-4) mol/L, with a slope and detection limit (S/N=3) of 2.3 mA/M and 5.0x10(-7) M, respectively. In addition, the glucose biosensor system indicates excellent reproducibility (less than 5% R.S.D.) and good operational stability (over 2 weeks).  相似文献   

8.
In this study, we report on a promising H(2)O(2) biosensor based on the co-immobilization of horseradish peroxidase (HRP) and chitosan onto Au-modified TiO(2) nanotube arrays. The titania nanotube arrays were directly grown on a Ti substrate using anodic oxidation first; a gold thin film was then uniformly coated onto the TiO(2) nanotube arrays by an argon plasma technique. The morphology and composition of the fabricated Au-modified TiO(2) nanotube arrays were characterized by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Cyclic voltammetry and chronoamperometry were used to study and to optimize the performance of the resulting electrochemical biosensor. The effect of pH, applied electrode potential, the presence of the electron-mediator methylene blue, and the anodic oxidation time of the Ti substrate on the electrochemical biosensor has been systemically studied. Our electrochemical measurements show that the Au-modified TiO(2) nanotube arrays provide excellent matrices for the immobilization of HRP and that the optimized electrochemical biosensor exhibits long linearity, a low detection limit, high stability and very good reproducibility for the detection of H(2)O(2). Under the optimized conditions the linearity of the developed biosensor for the detection of H(2)O(2) is observed from 5 x 10(-6) to 4 x 10(-4) moll(-1) with a detection limit of 2 x 10(-6) moll(-1) (based on the S/N=3).  相似文献   

9.
Han E  Shan D  Xue H  Cosnier S 《Biomacromolecules》2007,8(3):971-975
A new type of amperometric phenol biosensor based on chitosan/layered double hydroxides organic-inorganic composite film was described. This hybrid material combined the advantages of organic biopolymer, chitosan, and inorganic layered double hydroxides. Polyphenol oxidase (PPO) immobilized in the material maintained its activity well as the usage of glutaraldehyde was avoided. The composite films have been characterized by Fourier transform infrared. The results indicated that PPO retained the essential feature of its native structure in the composite film. The enzyme electrode provided a linear response to catechol over a concentration range of 3.6 x 10(-9) to 4 x 10(-5) M with a sensitivity of 2750 +/- 52 mA M(-1) cm(-2) and a detection limit of 0.36 nM based on S/N = 3. The apparent Michaelis-Menten constant K(app)(M) for the sensor was found to be 0.13 mM. The activation energy for enzymatic reaction was calculated to be 27.6 kJ mol(-1). Furthermore, the biosensor exhibited excellent long-term stability and satisfactory reproducibility.  相似文献   

10.
A novel inexpensive and simple amperometric biosensor, based on the immobilization of HRP into redox active [Zn-Cr-ABTS] layered double hydroxide, is applied to the determination of cyanide. The electrochemical transduction step corresponds to the reduction at 0.0 V of ABTS+* enzymatically formed in the presence of H2O2. The biosensor has a fast response to H2O2 (8s) with a linear range of 1.7 x 10(-9) to 2.1 x 10(-6) M and a sensitivity of 875 mA M(-1) cm(-2). The apparent Michaelis-Menten constant (KMapp) is 12 microM. The detection of cyanide is performed via its non competitive inhibiting action on the HRP/[Zn-Cr-ABTS] electrode. The concentration range of the linear response and the apparent inhibition constant (ki) are 5 x 10(-9) to 4 x 10(-8) and 1.4 x 10 (-7) M, respectively.  相似文献   

11.
A novel biosensor for superoxide radical (O(2)(*-)) detection based on Pseudomonas aeruginosa azurin immobilized on gold electrode was designed. The rate constant of azurin reduction by O(2)(*-) was found to be 10(5)M(-1)s(-1) in solution and five times lower, i.e., 0.2 x 10(5)M(-1)s(-1), for azurin coupled to gold by 3,3'-dithiobis(sulfosuccinimidylpropionate) (DTSSP). The electron transfer rate between the protein and the electrode ranged from 2 to 6s(-1). The sensitivity of this biosensor to O(2)(*-) was 6.8 x 10(2)Am(-2)M(-1). The response to the interference substances, such as uric acid, H(2)O(2), and dimethylsulfoxide was negligible below 10 microM. The electrode was applied in three O(2)(*-) generating systems: (i) xanthine oxidase (XOD), (ii) potassium superoxide (KO(2)), and (iii) stimulated neutrophil granulocytes. The latter was compared with luminol-amplified chemiluminescence. The biosensor responded to O(2)(*-) in all three environments, and the signals were antagonized by superoxide dismutase.  相似文献   

12.
A novel hydrogen peroxide biosensor was fabricated for the determination of H(2)O(2). The precursor film was first electropolymerized on the glassy carbon electrode with p-aminobenzene sulfonic acid (p-ABSA) by cyclic voltammetry (CV). Then thionine (Thi) was adsorbed to the film to form a composite membrane, which yielded an interface containing amine groups to assemble gold nanoparticles (nano-Au) layer for immobilization of horseradish peroxidase (HRP). The electrochemical characteristics of the biosensor were studied by CV and chronoamperometry. The factors influencing the performance of the resulting biosensor were studied in detail. The biosensor responded to H(2)O(2) in the linear range from 2.6 x 10(-6) mol/L to 8.8 x 10(-3) mol/L with a detection limit of 6.4 x 10(-7) mol/L. Moreover, the studied biosensor exhibited good accuracy and high sensitivity. The proposed method was economical and efficient, making it potentially attractive for the application to real sample analysis.  相似文献   

13.
In this work, a novel chemiluminescence (CL) flow biosensor for glucose was proposed. Glucose oxidase (GOD), horseradish peroxidase (HRP) and gold nanoparticles were immobilized with sol-gel method on the inside surface of the CL flow cell. The CL detection involved enzymatic oxidation of glucose to d-gluconic acid and H(2)O(2), and then the generated H(2)O(2) oxidizing luminol to produce CL emission in the presence of HRP. It was found that gold nanoparticles could remarkably enhance the CL respond of the glucose biosensor. The enhanced effect was closely related to the sizes of gold colloids, and the smaller the size of gold colloids had the higher CL respond. The immobilization condition and the CL condition were studied in detail. The CL emission intensity was linear with glucose concentration in the range of 1.0 x 10(-5)molL(-1) to 1.0 x 10(-3)molL(-1), and the detection limit was 5 x 10(-6)molL(-1) (3sigma). The apparent Michaelis-Menten constant of GOD in gold nanoparticles/sol-gel matrix was evaluated to be 0.3mmolL(-1), which was smaller than that of GOD immobilized in sol-gel matrix without gold nanoparticles. The proposed biosensor exhibited short response time, easy operation, low cost and simple assembly, and the proposed biosensor was successfully applied to the determination of glucose in human serum.  相似文献   

14.
A mediator-free phenol biosensor was developed. The low-isoelectric point tyrosinase was adsorbed on the surface of high-isoelectric point ZnO nanoparticles (nano-ZnO) facilitated by the electrostatic interactions and then immobilized on the glassy carbon electrode via the film forming by chitosan. It was found that the nano-ZnO matrix provided an advantageous microenvironment in terms of its favorable isoelectric point for tyrosinase loading and the immobilized tyrosinase retaining its activity to a large extent. Moreover, there is no need to use any other electron mediators. Phenolic compounds were determined by the direct reduction of biocatalytically generated quinone species at -200mV (vs. saturated calomel electrode). The parameters of the fabrication process and the various experimental variables for the enzyme electrode were optimized. The resulting biosensor can reach 95% of steady-state current within 10s, and the sensitivity was as high as 182microAmmol(-1)L. The linear range for phenol determination was from 1.5x10(-7) to 6.5x10(-5)molL(-1) with a detection limit of 5.0x 10(-8)molL(-1) obtained at a signal/noise ratio of 3. In addition, the apparent Michaelis-Menten constant (K(m)(app)) and the stability of the enzyme electrode were estimated. The performance of the developed biosensor was compared with that of biosensors based on other immobilization matrices.  相似文献   

15.
Nanosheet-based ZnO microsphere with porous nanostructures was synthesized by a facile chemical bath deposition method followed by thermal treatment, which was explored for the construction of electrochemical biosensors. Spectroscopic and electrochemical researches revealed the ZnO-based composite was a biocompatible immobilization matrix for enzymes with good enzymatic stability and bioactivity. With advantages of nanostructured inorganic-organic hybrid materials, a pair of stable and well-defined quasi-reversible redox peaks of hemoglobin was obtained with a formal potential of -0.345V (vs. Ag/AgCl) in pH 7.0 buffer. Facilitated direct electron transfer of the metalloenzymes with an apparent heterogeneous electron transfer rate constant (k(s)) of 3.2s(-1) was achieved on the ZnO-based enzyme electrode. Comparative studies demonstrated the nanosheet-based ZnO microspheres were more effective in facilitating the electron transfer of immobilized enzyme than solid ZnO microspheres, which may result from the unique nanostructures and larger surface area of the porous ZnO. The prepared biosensor displayed good performance for the detection of H(2)O(2) and NaNO(2) with a wide linear range of 1-410 and 10-2700muM, respectively. The entrapped hemoglobin exhibits high peroxidase-like activity for the catalytic reduction of H(2)O(2) with an apparent Michaelis-Menten constant (K(M)(app)) of 143muM. The nanosheet-based ZnO could be a promising matrix for the fabrication of direct electrochemical biosensors, and may find wide potential applications in biomedical detection and environmental analysis.  相似文献   

16.
A new film for the fabrication of an unmediated H2O2 biosensor   总被引:2,自引:0,他引:2  
A novel and stable film made from polyethylene glycol (PEG) on pyrolytic graphite (PG) electrode was presented in this paper for incorporating horseradish peroxidase (HRP) to study the direct electrochemistry of the enzyme. In PEG film, HRP showed a thin-layer electrochemistry behavior. The apparent standard potential (E degrees ') was -0.379 V versus SCE at pH 7.2. Moreover, the PEG-HRP modified electrode exhibited excellent electrocatalytical response to the reduction of H2O2 with a calibration range between 2.0 x 10(-6) and 6.0 x 10(-4) M and a good linear relation from 2.0 x 10(-6) to 1.0 x 10(-4) M, on which an unmediated H2O2 biosensor was based. The detection limit of 6.7 x 10(-7) M was estimated when the signal-to-noise ratio was 3. The relative standard deviation (R.S.D.) was 4.7% for six successive determinations at a concentration of 4.0 x 10(-5) M. The apparent Michaelis-Menten constant (Km app) of the sensor was found to be 1.38 mM. Epinephrine, dopamine, and ascorbic acid did not interfere with the sensitive determination of H2O2.  相似文献   

17.
A convenient and effective strategy for preparation nanohybrid film of multi-wall carbon nanotubes (MWNT) and gold colloidal nanoparticles (GNPs) by using proteins as linker is proposed. In such a strategy, hemoglobin (Hb) was selected as model protein to fabricate third-generation H2O2 biosensor based on MWNT and GNPs. Acid-pretreated, negatively charged MWNT was first modified on the surface of glassy carbon (GC) electrode, then, positively charged Hb was adsorbed onto MWNT films by electrostatic interaction. The {Hb/GNPs}n multilayer films were finally assembled onto Hb/MWNT film through layer-by-layer assembly technique. The assembly of Hb and GNPs was characterized with cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and transmission electron microscopy (TEM). The direct electron transfer of Hb is observed on Hb/GNPs/Hb/MWNT/GC electrode, which exhibits excellent electrocatalytic activity for the reduction of H2O2 to construct a third-generation mediator-free H2O2 biosensor. As compared to those H2O2 biosensors only based on carbon nanotubes, the proposed biosensor modified with MWNT and GNPs displays a broader linear range and a lower detection limit for H2O2 determination. The linear range is from 2.1x10(-7) to 3.0x10(-3) M with a detection limit of 8.0x10(-8) M at 3sigma. The Michaelies-Menten constant KMapp value is estimated to be 0.26 mM. Moreover, this biosensor displays rapid response to H2O2 and possesses good stability and reproducibility.  相似文献   

18.
The aerobic acidophilic bacterium Acidithiobacillus ferrooxidans oxidizes Fe(2+) and S(2)O(3)(2-) ions by consuming oxygen. An amperometric biosensor was designed including an oxygen probe as transducer and a recognition element immobilized by a suitable home-made membrane. This biosensor was used for the indirect amperometric determination of Cr(2)O(7)(2-) ions owing to methods based on a mediator (Fe(2+)) or titration. Using the mediator, the biosensor response versus Cr(2)O(7)(2-) was linear up to 0.4 mmol L(-1), with a response time of, respectively, 51 s (2 x 10(-5) mol L(-1) Cr(2)O(7)(2-)) and 61 s (6 x 10(-5) mol L(-1) Cr(2)O(7)(2-)). The method sensitivity was 816 microA L mol(-1). Response time and measurement sensitivity depended on membrane material and technique for biomass immobilization. For example, their values were 90 s-200 microA L mol(-1) when using a glass-felt membrane and 540 s-4.95 microA L mol(-1) with a carbon felt one to determine a concentration of 2 x 10(-5) mol L(-1) Cr(2)O(7)(2-). For the titration method, the biosensor is used to determine the equivalence point. The relative error of quantitative analysis was lower than 5%.  相似文献   

19.
Pyrrole was electropolymerized onto a Pt electrode in the presence of LiClO(4) and horseradish peroxidase (HRP). This HRP-based biosensor has been used for the amperometric detection of rifampicin (RIF) in the presence of a constant concentration of H(2)O(2). The C(H(2)O(2)) as well as the applied potential (E(ap)) and the pH of the phosphate buffer have simultaneously been optimized through a central composite design. Under these conditions, repeatability, reproducibility, and stability of the modified electrode have been analyzed. The detection limit for RIF has been calculated taking into account the probability of false-positive (alpha) and -negative (beta), reaching a value of 5.06x10(-6) mol dm(-3). The biosensor was applied to the determination of RIF in pharmaceutical preparations and biological samples.  相似文献   

20.
A novel tyrosinase biosensor based on Fe(3)O(4) nanoparticles-chitosan nanocomposite has been developed for the detection of phenolic compounds. The large surface area of Fe(3)O(4) nanoparticles and the porous morphology of chitosan led to a high loading of enzyme and the entrapped enzyme could retain its bioactivity. The tyrosinase-Fe(3)O(4) nanoparticle-chitosan bionanocomposite film was characterized with atomic force microscopy and AC impedance spectra. The prepared biosensor was used to determine phenolic compounds by amperometric detection of the biocatalytically liberated quinone at -0.2V vs. saturated calomel electrode (SCE). The different parameters, including working potential, pH of supporting electrolyte and temperature that governs the analytical performance of the biosensor have been studied in detail and optimized. The biosensor was applied to detect catechol with a linear range of 8.3 x 10(-8) to 7.0 x 10(-5)mol L(-1), and the detection limit of 2.5 x 10(-8)mol L(-1). The tyrosinase biosensor exhibits good repeatability and stability. Such new tyrosinase biosensor shows great promise for rapid, simple, and cost-effective analysis of phenolic contaminants in environmental samples. The proposed strategy can be extended for the development of other enzyme-based biosensors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号