共查询到20条相似文献,搜索用时 15 毫秒
1.
Robert J. Nims Alexander D. Cigan Michael B. Albro Clark T. Hung Gerard A. Ateshian 《Journal of biomechanics》2014
Large-sized cartilage constructs suffer from inhomogeneous extracellular matrix deposition due to insufficient nutrient availability. Computational models of nutrient consumption and tissue growth can be utilized as an efficient alternative to experimental trials to optimize the culture of large constructs; models require system-specific growth and consumption parameters. To inform models of the [bovine chondrocyte]−[agarose gel] system, total synthesis rate (matrix accumulation rate+matrix release rate) and matrix retention fractions of glycosaminoglycans (GAG), collagen, and cartilage oligomeric matrix protein (COMP) were measured either in the presence (continuous or transient) or absence of TGF-β3 supplementation. TGF-β3's influences on pyridinoline content and mechanical properties were also measured. Reversible binding kinetic parameters were characterized using computational models. Based on our recent nutrient supplementation work, we measured glucose consumption and critical glucose concentration for tissue growth to computationally simulate the culture of a human patella-sized tissue construct, reproducing the experiment of Hung et al. (2003). Transient TGF-β3 produced the highest GAG synthesis rate, highest GAG retention ratio, and the highest binding affinity; collagen synthesis was elevated in TGF-β3 supplementation groups over control, with the highest binding affinity observed in the transient supplementation group; both COMP synthesis and retention were lower than those for GAG and collagen. These results informed the modeling of GAG deposition within a large patella construct; this computational example was similar to the previous experimental results without further adjustments to modeling parameters. These results suggest that these nutrient consumption and matrix synthesis models are an attractive alternative for optimizing the culture of large-sized constructs. 相似文献
2.
Azhar A. Ali Luca Cristofolini Enrico Schileo Haixiang Hu Fulvia Taddei Raymond H. Kim Paul J. Rullkoetter Peter J. Laz 《Journal of biomechanics》2014
Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50% due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59%:41% to 89%:11%, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants. 相似文献
3.
丝纤维特别是丝素蛋白和蜘蛛丝蛋白作为具有良好生物相容性的高分了生物材料在组织工程和生物医学领域里有着广泛的应用。本文阐述了近年来在组织工程研究中所涉及的利用丝纤维进行支架材料制备、细胞培养和体内植入检测手段等方面的研究概况。 相似文献
4.
《Journal of biological dynamics》2013,7(2):406-439
This article introduces a two-strain spatially explicit SIS epidemic model with space-dependent transmission parameters. We define reproduction numbers of the two strains, and show that the disease-free equilibrium will be globally stable if both reproduction numbers are below one. We also introduce the invasion numbers of the two strains which determine the ability of each strain to invade the single-strain equilibrium of the other strain. The main question that we address is whether the presence of spatial structure would allow the two strains to coexist, as the corresponding spatially homogeneous model leads to competitive exclusion. We show analytically that if both invasion numbers are larger than one, then there is a coexistence equilibrium. We devise a finite element numerical method to numerically confirm the stability of the coexistence equilibrium and investigate various competition scenarios between the strains. Finally, we show that the numerical scheme preserves the positive cone and converges of first order in the time variable and second order in the space variables. 相似文献
5.
J. Pierre 《Computer methods in biomechanics and biomedical engineering》2013,16(6):429-438
Successful bone cell culture in large implants still is a challenge to biologists and requires a strict control of the physicochemical and mechanical environments. This study analyses from the transport phenomena viewpoint the limiting factors of a perfusion bioreactor for bone cell culture within fibrous and porous large implants (2.5 cm in length, a few cubic centimetres in volume, 250 μm in fibre diameter with approximately 60% porosity). A two-dimensional mathematical model, based upon stationary mass and momentum transport in these implants is proposed and numerically solved. Cell oxygen consumption, in accordance theoretically with the Michaelis–Menten law, generates non linearity in the boundary conditions of the convection diffusion equation. Numerical solutions are obtained with a commercial code (Femlab® 3.1; Comsol AB, Stockholm, Sweden). Moreover, based on the simplification of transport equations, a simple formula is given for estimating the length of the oxygen penetration within the implant. Results show that within a few hours of culture process and for a perfusion velocity of the order of 10? 4 m s? 1, the local oxygen concentration is everywhere sufficiently high to ensure a suitable cell metabolism. But shear stresses induced by the fluid flow with such a perfusion velocity are found to be locally too large (higher than 10? 3 Pa). Suitable shear stresses are obtained by decreasing the velocity at the inlet to around 2 × 10? 5 m s? 1. But consequently hypoxic regions (low oxygen concentrations) appear at the downstream part of the implant. Thus, it is suggested here that in the determination of the perfusion flow rate within a large implant, a compromise between oxygen supply and shear stress effects must be found in order to obtain a successful cell culture. 相似文献
6.
Excitability and isometric contractile properties of mammalian skeletal muscle constructs engineered in vitro 总被引:6,自引:2,他引:6
Summary Our purpose was to engineer three-dimensional skeletal muscle tissue constructs from primary cultures of adult rat myogenic
precursor cells, and to measure their excitability and isometric contractile properties. The constructs, termed myooids, were
muscle-like in appearance, excitability, and contractile function. The myooids were 12 mm long and ranged in diameter from
0.1 to 1 mm. The myooids were engineered with synthetic tendons at each end to permit the measurement of isometric contractile
properties. Within each myooid the myotubes and fibroblasts were supported by an extracellular matrix generated by the cells
themselves, and did not require a preexisting scaffold to define the size, shape, and general mechanical properties of the
resulting structure. Once formed, the myooids contracted spontaneously at approximately 1 Hz, with peak-to-peak force amplitudes
ranging from 3 to 30 μN. When stimulated electrically the myooids contracted to produce force. The myooids (n=14) had the following mean values:
diameter of 0.49 mm, rheobase of 1.0 V/mm, chronaxie of 0.45 ms, twitch force of 215 μN, maximum isometric force of 440 μN, resting baseline force of 181 μN, and specific force of 2.9kN/m2. The mean specific force was approximately 1% of the specific force generated by control adult rat muscle. Based on the functional
data, the myotubes in the myooids appear to remain arrested in an early developmental state due to the absence of signals
to promote expression of adult myosin isoforms. 相似文献
7.
Marco Piccinini Joel Cugnoni John Botsis Patrick Ammann Anselm Wiskott 《Journal of biomechanics》2014
Implanted rat bones play a key role in studies involving fracture healing, bone diseases or drugs delivery among other themes. In most of these studies the implants integration also depends on the animal daily activity and musculoskeletal loads, which affect the implants mechanical environment. However, the tissue adaption to the physiological loads is often filtered through control groups or not inspected. This work aims to investigate experimentally and numerically the effects of the daily activity on the integration of implants inserted in the rat tibia, and to establish a physiological loading condition to analyse the peri-implant bone stresses during gait. Two titanium implants, single and double cortex crossing, are inserted in the rat tibia. The animals are caged under standard conditions and divided in three groups undergoing progressive integration periods. The results highlight a time-dependent increase of bone samples with significant cortical bone loss. The phenomenon is analysed through specimen-specific Finite Element models involving purpose-built musculoskeletal loads. Different boundary conditions replicating the post-surgery bone–implant interaction are adopted. The effects of the gait loads on the implants integration are quantified and agree with the results of the experiments. The observed cortical bone loss can be considered as a transient state of integration due to bone disuse atrophy, initially triggered by a loss of bone–implant adhesion and subsequently by a cyclic opening of the interface. 相似文献
8.
G. Fortuny J. Rodríguez-Navarro A. Susín M. Lpez-Cano 《Journal of biomechanics》2009,42(14):2263-2267
Simulating the muscular system has many applications in biomechanics, biomedicine and the study of movement in general. We are interested in studying the genesis of a very common pathology: human inguinal hernia. We study the effects that some biomechanical parameters have on the dynamic simulation of the region, and their involvement in the genesis of inguinal hernias. We use the finite element method (FEM) and current models for the muscular contraction to determine the deformed fascia transversalis for the estimation of the maximum strain. We analysed the effect of muscular tissue density, Young's modulus, Poisson's coefficient and calcium concentration in the genesis of human inguinal hernia. The results are the estimated maximum strain in our simulations, has a close correlation with experimental data and the accepted commonly models by the medical community. Our model is the first study of the effect of various biological parameters with repercussions on the genesis of the inguinal hernias. 相似文献
9.
The physical environment of myocardium, featuring excitation-contraction coupling, constant and efficient provision of nutrient/oxygen and delicate integration of cardiomyocytes and supporting cell population (fibroblasts, endothelial cells), is one of the most complex systems in human body. Numerous studies have demonstrated the significance of physical stimulation in cardiac cell physiology, including the maintenance of contractile function in cardiomyocytes,1 cell alignment and extracellular matrix secretion in fibroblasts and endothelial cells.2,3 In effort to reconstruct the physical environment found in the cardiac niche for routine cell culture use, we have devised a bioreactor system to account for three major forms of physical stimuli, namely, cyclic stretch, electrical stimulation and fluid perfusion.4 相似文献
10.
Non-linear and anisotropic heart valve leaflet tissue mechanics manifest principally from the stratification, orientation, and inhomogeneity of their collagenous microstructures. Disturbance of the native collagen fiber network has clear consequences for valve and leaflet tissue mechanics and presumably, by virtue of their intimate embedment, on the valvular interstitial cell stress–strain state and concomitant phenotype. In the current study, a set of virtual biaxial stretch experiments were conducted on porcine pulmonary valve leaflet tissue photomicrographs via an image-based finite element approach. Stress distribution evolution during diastolic valve closure was predicted at both the tissue and cellular levels. Orthotropic material properties consistent with distinct stages of diastolic loading were applied. Virtual experiments predicted tissue- and cellular-level stress fields, providing insight into how matrix-to-cell stress transfer may be influenced by the inhomogeneous collagen fiber architecture, tissue anisotropic material properties, and the cellular distribution within the leaflet tissue. To the best of the authors’ knowledge, this is the first study reporting on the evolution of stress fields at both the tissue and cellular levels in valvular tissue and thus contributes toward refining our collective understanding of valvular tissue micromechanics while providing a computational tool enabling the further study of valvular cell–matrix interactions. 相似文献
11.
Ali Vahdati 《Computer methods in biomechanics and biomedical engineering》2013,16(11):1211-1221
Most tissue-engineered cartilage constructs are more compliant than native articular cartilage (AC) and are poorly integrated to the surrounding tissue. To investigate the effect of an implanted tissue-engineered construct (TEC) with these inferior properties on the mechanical environment of both the engineered and adjacent native tissues, a finite element study was conducted. Biphasic swelling was used to model tibial cartilage and an implanted TEC with the material properties of either native tissue or a decreased elastic modulus and fixed charged density. Creep loading was applied with a rigid impermeable indenter that represented the femur. In comparison with an intact joint, compressive strains in the transplant, surface contact stress in the adjacent native AC and load partitioning between different phases of cartilage were affected by inferior properties of TEC. Results of this study may lead to a better understanding of the complex mechanical environment of an implanted TEC. 相似文献
12.
Lee C. M., Harris L. M. and Aboko-Cole G. F. 1978. Trypanosoma lewisi: comparative activity of a feral isolate in two strains of rats assessed by measurement of cell population, reproductive development and respiratory activity. International Journal for Parasitclogy8: 187–192. Comparative respiratory behaviour, population growth and host antibody formation were examined for a feral isolate of Trypanosoma lewisi grown in albino and black rats. Oxygen uptake was measured for endogenous, glucose or normal homologous rat serum substrates. Trypanosomes from albino rats respired 72% faster endogenously, 70% faster with glucose, and 60% faster with rat serum than parasites from black rats. Greater oxygen consumption of T. lewisi from albino rat hosts correlated well with the fact that the trypanosome developed greater parasitemias in albino than in black rats. Parasitemias were patent longer in albino rats and peak populations were found 2 days later in these hosts than in black rats. On the average, higher coefficients of variability in cell length continued five days longer in albino rats than in black animals. Delay in reproductive development was indicated by continued low variability in trypanosome cell sizes in albino and black rats. 相似文献
13.
S. Mehrdad Hosseini Kalajahi S. Majid Nazemi 《Computer methods in biomechanics and biomedical engineering》2013,16(16):1258-1268
AbstractQuantitative computed tomography-based finite element (QCT-FE) modeling has potential to clarify the role of altered subchondral bone stiffness in osteoarthritis. The objective of this research was to evaluate different QCT-FE modeling and thresholding approaches to identify the method which best predicted experimentally measured local subchondral structural stiffness with highest explained variance and least error. Our results showed that separate modeling of proximal tibial cortical and trabecular bone offered little improvement in QCT-FE-predicted stiffness (0% to +3% improvement in explained variance) when compared to modeling the proximal tibia as a single structure. Based on the results of this study, we do not recommend separate modeling of cortical bone and trabecular bone when developing QCT-FE models of the proximal tibia for predicting subchondral bone stiffness. 相似文献
14.
15.
Elastic properties of materials can be measured by observing shear wave propagation following localized, impulsive excitations and relating the propagation velocity to a model of the material. However, characterization of anisotropic materials is difficult because of the number of elasticity constants in the material model and the complex dependence of propagation velocity relative to the excitation axis, material symmetries, and propagation directions. In this study, we develop a model of wave propagation following impulsive excitation in an incompressible, transversely isotropic (TI) material such as muscle. Wave motion is described in terms of three propagation modes identified by their polarization relative to the material symmetry axis and propagation direction. Phase velocities for these propagation modes are expressed in terms of five elasticity constants needed to describe a general TI material, and also in terms of three constants after the application of two constraints that hold in the limit of an incompressible material. Group propagation velocities are derived from the phase velocities to describe the propagation of wave packets away from the excitation region following localized excitation. The theoretical model is compared to the results of finite element (FE) simulations performed using a nearly incompressible material model with the five elasticity constants chosen to preserve the essential properties of the material in the incompressible limit. Propagation velocities calculated from the FE displacement data show complex structure that agrees quantitatively with the theoretical model and demonstrates the possibility of measuring all three elasticity constants needed to characterize an incompressible, TI material. 相似文献
16.
Online measurement of the respiratory activity in shake flasks enables the identification of cultivation phases and patterns indicating recombinant protein production in various Escherichia coli host strains
下载免费PDF全文

Nina Ihling Natalie Bittner Sylvia Diederichs Maximilian Schelden Anna Korona Georg Theo Höfler Alexander Fulton Karl‐Erich Jaeger Kohsuke Honda Hisao Ohtake Jochen Büchs 《Biotechnology progress》2018,34(2):315-327
Escherichia coli is commonly used for recombinant protein production with many available host strains. Screening experiments are often performed in batch mode using shake flasks and evaluating only the final product concentration. This conventional approach carries the risk of missing the best strain due to limited monitoring capabilities. Thus, this study focuses on investigating the general suitability of online respiration measurement for selecting expression hosts for heterologous protein production. The oxygen transfer rate (OTR) for different T7‐RNA polymerase‐dependent Escherichia coli expression strains was compared under inducing and noninducing conditions. As model enzymes, a lipase A from Bacillus subtilis (BSLA) and a 3‐hydroxybutyryl‐CoA dehydrogenase from Thermus thermophilus (HBD) were chosen. Four strains were compared during expression of both enzymes in autoinduction medium. Additionally, four strains were compared during expression of the BSLA with IPTG induction. It was found that the metabolic burden during recombinant protein production induces a phase of constant OTR, while undisturbed cell growth with no or little product formation is indicated by an exponential increase. This pattern is independent of the host strain, expressed enzyme, and induction method. Furthermore, the OTR gives information about carbon source consumption, biomass formation, and the transition from production to noninduced second growth phase, thereby ensuring a fair comparison of different strains. In conclusion, online monitoring of the respiration activity is suited to qualitatively identify, if a recombinant protein is produced by a strain or not. Furthermore, laborious offline sampling is avoided. Thus, the technique is easier and faster compared to conventional approaches. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 34:315–327, 2018 相似文献
17.
M. El-Rich 《Computer methods in biomechanics and biomedical engineering》2013,16(6):359-368
A novel kinematics-based approach coupled with a non-linear finite element model was used to investigate the effect of changes in the load position and posture on muscle activity, internal loads and stability margin of the human spine in upright standing postures. In addition to 397 N gravity, external loads of 195 and 380 N were considered at different lever arms and heights. Muscle forces, internal loads and stability margin substantially increased as loads displaced anteriorly away from the body. Under same load magnitude and location, adopting a kyphotic posture as compared with a lordotic one increased muscle forces, internal loads and stability margin. An increase in the height of a load held at a fixed lever arm substantially diminished system stability thus requiring additional muscle activations to maintain the same margin of stability. Results suggest the importance of the load position and lumbar posture in spinal biomechanics during various manual material handling operations. 相似文献
18.
Zheng-Cheng Zhong Chinghua Hung Hung-Ming Lin Ying-Hui Wang Chang-Hung Huang 《Computer methods in biomechanics and biomedical engineering》2013,16(9):943-953
In a finite element (FE) analysis of the lumbar spine, different preload application methods that are used in biomechanical studies may yield diverging results. To investigate how the biomechanical behaviour of a spinal implant is affected by the method of applying the preload, hybrid-controlled FE analysis was used to evaluate the biomechanical behaviour of the lumbar spine under different preload application methods. The FE models of anterior lumbar interbody fusion (ALIF) and artificial disc replacement (ADR) were tested under three different loading conditions: a 150 N pressure preload (PP) and 150 and 400 N follower loads (FLs). This study analysed the resulting range of motion (ROM), facet contact force (FCF), inlay contact pressure (ICP) and stress distribution of adjacent discs. The FE results indicated that the ROM of both surgical constructs was related to the preload application method and magnitude; differences in the ROM were within 7% for the ALIF model and 32% for the ADR model. Following the application of the FL and after increasing the FL magnitude, the FCF of the ADR model gradually increased, reaching 45% at the implanted level in torsion. The maximum ICP gradually decreased by 34.1% in torsion and 28.4% in lateral bending. This study concluded that the preload magnitude and application method affect the biomechanical behaviour of the lumbar spine. For the ADR, remarkable alteration was observed while increasing the FL magnitude, particularly in the ROM, FCF and ICP. However, for the ALIF, PP and FL methods had no remarkable alteration in terms of ROM and adjacent disc stress. 相似文献
19.
G. WAYNE BRODLAND JIM H. VELDHUIS 《Computer methods in biomechanics and biomedical engineering》2013,16(2):89-98
Although cell reshaping is fundamental to the mechanics of epithelia, technical barriers have prevented the methods of mechanics from being used to investigate it. These barriers have recently been overcome by the cell-based finite element formulation of Chen and Brodland. Here, parameters to describe the fabric of an epithelium in terms of cell shape and orientation and cell edge density are defined. Then, rectangular "patches" of model epithelia having various initial fabric parameters are generated and are either allowed to anneal or are subjected to one of several patterns of in-plane deformation. The simulations show that cell reshaping lags the deformation history, that it is allayed by cell rearrangement and that it causes the epithelium as a whole to exhibit viscoelastic mechanical properties. Equations to describe changes in cell shape due to annealing and in-plane deformation are presented. 相似文献
20.
Medial knee osteoarthritis is a debilitating disease. Surgical and conservative interventions are performed to manage its progression via reduction of load on the medial compartment or equivalently its surrogate measure, the external adduction moment. However, some studies have questioned a correlation between the medial load and adduction moment. Using a musculoskeletal model of the lower extremity driven by kinematics–kinetics of asymptomatic subjects at gait midstance, we aim here to quantify the relative effects of changes in the knee adduction angle versus changes in the adduction moment on the joint response and medial/lateral load partitioning. The reference adduction rotation of 1.6° is altered by ±1.5° to 3.1° and 0.1° or the knee reference adduction moment of 17 N m is varied by ±50% to 25.5 N m and 8.5 N m. Quadriceps, hamstrings and tibiofemoral contact forces substantially increased as adduction angle dropped and diminished as it increased. The medial/lateral ratio of contact forces slightly altered by changes in the adduction moment but a larger adduction rotation hugely increased this ratio from 8.8 to a 90 while in contrast a smaller adduction rotation yielded a more uniform distribution. If the aim in an intervention is to diminish the medial contact force and medial/lateral load ratio, a drop of 1.5° in adduction angle is much more effective (causing respectively 12% and 80% decreases) than a reduction of 50% in the adduction moment (causing respectively 4% and 13% decreases). Substantial role of changes in adduction angle is due to the associated alterations in joint nonlinear passive resistance. These findings explain the poor correlation between knee adduction moment and tibiofemoral compartment loading during gait suggesting that the internal load partitioning is dictated by the joint adduction angle. 相似文献