首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A sensitive method for the separation of phospholipids by a HPLC procedure is described. The separation was carried out on a 30 cm prepacked column with aminopropyl bonded silica under isocratic conditions. The effective separation of major phospholipid classes was carried out for less than 5 min. These chromatographic conditions were used for analysis of natural phospholipid mixtures.  相似文献   

2.
3.
An optimized method for the determination of flecainide in serum is presented. Extraction using a solid-phase C18 column and chromatography on a stabilized fluorocarbon-bonded silica gel column effectively separate flecainide from an internal standard (a positional isomer of flecainide). The HPLC apparatus and conditions were as follows: analytical column, Fluofix 120N; sample solvent, 20 μl; column temperature, 40°C; detector, Shimadzu RF-5000 fluorescence spectrophotometer (excitation wavelength=300 nm, emission wavelength=370 nm); mobile phase, 0.06% phosphoric acid containing 0.1% tetra-n-butyl ammonium bromide–acetonitrile (75:25, v/v); flow-rate, 1.0 ml/min. The standard curves for flecainide were linear in the concentration range examined (10–2000 ng/ml). The regression equation was y=0.08+0.0078x (r=0.9998). The minimum detectable amount of flecainide was approximately 5 ng/ml. In the within-day study, the precision coefficients of variation were 2.66, 2.18, 2.54, 2.72, 2.88, 2.24, and 3.29% for the 10, 50, 100, 200, 500, 1000, and 1500 ng/ml standards, respectively. The absolute recovery rates of flecainide at each concentrations were 94–100%. The method described provides analytical sensitivity, specificity and reproducibility suitable for both biomedical research and therapeutic drug monitoring.  相似文献   

4.
A simple preparative system is described for rapid and efficient purification of protected synthetic peptides on a gram scale by high performance liquid chromatography on prepacked silica gel 60 columns. A variety of protected peptides up to tetradecapeptides have been chromatographed at pressures of 50 to 150 psi and obtained in analytically pure from within 2 to 4 h. With such commonly used protecting groups as N-benzyloxycarbonyl (Z), N-2-(p-biphenylyl)-2-propyloxycarbonyl (Bpoc), N-t-butyloxycarbonyl (Boc), O- and S-t-butyl (But), and S-acetamidomethyl (Acm), compounds were sufficiently soluble in chloroform, alcohols, acetic acid, or mixtures of these solvents for column loading. Dimethylformamide was also used as a solvent for loading. Solvent systems for column elution in isocratic, stepwise, or gradient modes were composed of chloroform, isopropanol, ethanol, or methanol and acetic acid in ratios that differed for each protected peptide depending on Rf values on t.l.c. plates. A simple chromatography is described which was self-assembled using standard instruments commonly in use in most laboratories. A shut-off valve was designed to prevent loss of material between fractions.  相似文献   

5.
Dependence of the peptide retention upon the organic component concentration in eluent has been studied. A parabolic dependence has been found in a wide range of acetonitrile concentrations. The effect observed with ODS- and unmodified silica as stationary phases extends analytical and preparative potentialities of HPLC of peptides.  相似文献   

6.
7.
8.
The affinity chromatography on uracil-coupled cellulose was carried out for the separation of nucleosides, nucleotides and oligonucleotides. Adenine derivatives exhibited a high affinity to uracil-cellulose, and sequencial isomers of oligonucleotides containing adenine residue were resolved. Poly(A) was strongly bound to uracil-cellulose and recovered by the elution with 7M urea. This procedure was extended to the isolation of mRNA containing poly(A) sequences.  相似文献   

9.
Here we investigate the chromatographic behavior, with reversed-phase high performance liquid chromatography (RP-HPLC) of nucleic compounds (nucleobases, nucleosides, and nucleotides) on a C18 column in several different mobile phase additives, including1-butyl-3-methylimidazolium tetrafuloroborate ([BMIm][BF4]), 1-ethyl-3-methylimidazolium methylsulfate ([EMIm][MS]) ionic liquids, ammonium formate, and potassium phosphate. The effect of the alkyl group length, the imidazolium ring, and the ionic liquid's counterions on retention and resolution of the samples were tested. The results show the potential application of a used buffer system, ion pairing system, and ionic liquid as mobile phase additives in liquid chromatography resolution of nucleic compounds.  相似文献   

10.
11.
The analytical chromatography of proto, meso, hemato, deutero, and diacetyldeutero hemins, and of MnIII, CoIII, and FeIII mesoporphyrins by tlc on silica gel is described.  相似文献   

12.
Thin-layer chromatography on silica gel 60 plates in the solvent N,N-dimethylformamide/methanol/ethylene glycol/glacial acetic acid/1-chlorobutane/chloroform (4/35/6/0.4/18/20 by volume) separates porphyrin carboxylic acids by the number of free carboxyl groups. Coproporphyrins I and III and isocoproporphyrin are separated in 30 min, other porphyrins in 15 min. The N,N-dimethylformamide and acetic acid in the solvent strongly increase porphyrin fluorescence on the plates. Fading and diffusion of the fluorescent patterns is prevented by storage of the plates in the cold and dark without oxygen and with desiccant. In a preliminary step, porphyrins are purified in high yields, concentrated, and deacidified rapidly (2 min) by reversephase chromatography on cartridges containing a C18 spacer or on Amberlite XAD-2 columns. The methods are applied to urines of porphyria patients and for following porphyrin ester hydrolysis.  相似文献   

13.
Glycerolpropylsilane bonded phases have been found to adsorb peptides and proteins via ionic interactions. In this paper high-performance liquid chromatography separation of glucagon and related compounds, using a Diol-silica matrix, is described. Crystalline, commercial preparations of glucagon, when analyzed on LiChrosorb Diol columns eluted with low-ionic-strength acidic buffers, contained up to four contaminant peaks, in different numbers and ratios. Three of these contaminants, called A, C, and D, were recovered and characterized. Contaminant A, representing a few percent of the total, was a mixture of mono- and didesamidoglucagon, as shown by treatment with bis(I,I-trifluoroacetoxy)iodobenzene, with which it is possible to differentiate between carboxamide and carboxylic acid residues. Contaminant C, ranging from 0 to about 30% of the total, was N-terminal degraded glucagon. Contaminant D, ranging from a few percent to about 25% of the total, was (Met27 sulfoxide) glucagon.  相似文献   

14.
采用大孔吸附树脂层析结合硅胶柱层析,对环孢菌素A的分离纯化进行研究,确定了最佳层析条件,建立了工业化制备环孢菌素A的工艺。大孔吸附树脂层析选用D101树脂作为吸附介质,提取液丙酮含量控制在50%,最大吸附量为35 mg/g湿树脂,洗脱剂选用丙酮;硅胶柱层析选用42~64μm硅胶作为层析介质,最优层析条件为柱床高径比10∶1,流动相配比V(石油醚)∶V(丙酮)=70∶30,流速80 mL/m in,环孢菌素A上样质量浓度100 g/L,硅胶层析平均收率为84.2%,环孢菌素A纯度可达到97%以上,整个工艺总收率为65%~70%。  相似文献   

15.
J Cadet  L Voituriez  A Grand  F E Hruska  P Vigny  L S Kan 《Biochimie》1985,67(3-4):277-292
This survey focuses on recent developments in the far ultraviolet photochemistry of nucleic acids and related model compounds. The photoproducts discussed are the cyclobutidipyrimidines, the pyrimidine-pyrimidone adducts, the purine-pyrimidine adducts and the addition products of amino acids to pyrimidine bases. The specific aspects of the high-intensity laser photochemistry of nucleic acid components are also briefly reviewed.  相似文献   

16.
17.
18.
The introduction of alkylated, nonporous poly-(styrene-divinylbenzene) microparticles in 1992 enabled the subsequent development of denaturing HPLC that has emerged as the most sensitive screening method for mutations to date. Denaturing HPLC has provided unprecedented insight into human origins and prehistoric migrations, accelerated the cloning of genes involved in mono- and polygenic traits, and facilitated the mutational analysis of more than a hundred candidate genes of human disease. A significant step toward increased sample-throughput and information content was accomplished by the recent introduction of monolithic poly(styrene-divinylbenzene) capillary columns. They have enabled the construction of capillary arrays amenable to multiplex analysis of fluorescent dye-labeled nucleic acids by laser-induced fluorescence detection. Hyphenation of denaturing HPLC with electrospray ionization mass spectrometry, on the other hand, has allowed the direct elucidation of the chemical nature of DNA variation and determination of phase of multiple alleles on a chromosome.  相似文献   

19.
Hydroxyapatite thermal elution chromatography was studied from an empirical standpoint. The dependence of elution temperature on elution buffer concentration was determined for various types of buffer, hydroxyapatite and nucleic acid. The results are analyzed in terms of the proper design and interpretation of thermal elution experiments. The potential for serious artifacts is demonstrated and the means by which they may be avoided is described. Various commercially available hydroxyapatites were tested in conjunction with various aqueous and partially non-aqueous buffer systems. Among the materials tested, potassium phosphate and Bio-Rad HTP were found to constitute the best buffer-hydroxyapatite system for most types of thermal elution study.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号