首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 37 毫秒
1.
Brain-stem trigeminal evoked potentials (BTEPs) were monitored intraoperatively in 17 patients during posterior fossa surgery. Satisfactory BTEP recording was performed in all patients without technical problems or interfering with the activity of the operating team. The BTEP was not altered by anesthetic agents or muscle relaxants. Intraoperative monitoring of the BTEP showed wave form alterations or increasing peak latencies in 10 patients. Among these patients, the BTEP demonstrated a dynamic correlation with the surgical process in 8 instances. Two major causative surgical manipulations were identified: cerebellar retraction in 4 cases and tumor dissection from the brain-stem in 6 cases. Withholding the dissection of the tumor, readjusting a cerebellar retractor or further modifying the surgical attitude resulted in partial or complete return of the wave form in 7 patients. The BTEP at the end of surgery proved to correlate with the immediate surgical outcome in most instances. We concluded that the intraoperative monitoring of the BTEP was feasible and suggested, despite the small number of patients, a potential value in the survey of brain-stem functions during posterior fossa surgery.  相似文献   

2.
When auditory nerve function is lost due to surgical removal of bilateral acoustic tumors, a sense of hearing may be restored by means of an auditory brain-stem implant (ABI), which electrically stimulates the auditory pathway at the level of the cochlear nucleus. Placement of the stimulating electrodes during surgical implantation may be aided by electrically evoked auditory brain-stem responses (EABRs) recorded intra-operatively. To establish preliminary standards for human EABRs evoked by electrical stimulation of the cochlear nucleus, short-latency evoked potentials were recorded from 6 ABI patients who were either already implanted or undergoing implantation surgery. Neural responses were distinguished from stimulus artifact and equipment artifact by their properties during stimulus polarity reversal and amplitude variation. Other properties contributed to further identification of the evoked potentials as auditory responses (EABRs). The response waveforms generally had 2 or 3 waves. The peak latencies of these waves (approximately 0.3, 1.3, and 2.2 msec) and the brain-stem localization of the region from which they could be elicited are consistent with auditory brain-stem origin.  相似文献   

3.
Brain-stem auditory evoked potentials (BAEP) recorded from the seagull were large-amplitude, short-latency, vertex-positive deflections which originate in the eighth nerve and several brain-stem nuclei. BAEP waveforms were similar in latency and configurations to that reported for certain other lower vertebrates and some mammals. BAEP recorded at several pure tone frequencies throughout the seagull's auditory spectrum showed an area of heightened auditory sensitivity between 1 and 3 kHz. This range was also found to be the primary bandwidth of the vocalization output of young seagulls. Masking by white noise and pure tones had remarkable effects on several parameters of the BAEP. In general, the tone- and click-induced BAEP were either reduced or obliterated by both pure tone and white noise maskers of specific signal to noise ratios and high intensity levels. The masking effects observed in this study may be related to the manner in which seagulls respond to intense environmental noise. One possible conclusion is that intense environmental noise, such as aircraft engine noise, may severely alter the seagull's localization apparatus and induce sonogenic stress, both of which could cause collisions with low-flying aircraft.  相似文献   

4.
Recordings from the vicinity of the cochlear nucleus in 9 patients undergoing microvascular decompression operations to relieve hemifacial spasm, trigeminal neuralgia, tinnitus, and disabling positional vertigo were conducted by placing a monopolar electrode in the lateral recess of the fourth ventricle (through the foramen of Luschka), the floor of which is the dorsolateral surface of the dorsal cochlear nucleus. The click-evoked potentials recorded by such an electrode display a slow negative wave with a peak latency of about 6–7 msec on which several sharp peaks are superimposed. None of the peaks in the recordings from the vicinity of the cochlear nucleus coincided with any vertex-positive peaks of the brain-stem auditory evoked potentials. In recordings from the lateral aspect of the floor of the fourth ventricle near the cochlear nucleus 1 patient showed 2 positive peaks, the earliest of which had a latency close to that of peak II and the second of which had a latency close to the negative peak between peaks III and IV of the brain-stem auditory evoked potentials. There is a distinct negative peak in the responses recorded from the midline of the floor of the fourth ventricle, the latency of which is only slightly shorter than that of peak V of the brain-stem auditory evoked potentials, supporting earlier findings that the sharp tip of peak V of the brain-stem auditory evoked potentials is generated by the termination of the lateral lemniscus in the inferior colliculus.  相似文献   

5.
Brain-stem auditory evoked potentials (BAEPs) have been used to gauge effects of brain-stem dysfunction in humans and animal models. The purpose of this study was to evaluate the usefulness of BAEP in monitoring patients undergoing decompressive surgery of the posterior fossa for space occupying cerebellar infarcts.We report on serial BAEP recordings in 11 comatose patients with space occupying cerebellar infarcts undergoing decompressive craniotomy. BAEP studies were performed within 12 h after admission, 24 h following surgery and prior to extubation. BAEP signals were analyzed using latency determination and cross-correlation.Following surgery, 9 patients regained consciousness; 2 patients persisted in a comatose state and died subsequently.BAEP interpeak latency (IPL) I-V assessed prior to surgery exceeded normal values in all patients in whom it could be reliably measured (N = 9). Following decompressive surgery BAEP wave I-V IPL normalized in 5 patients, but remained prolonged despite dramtic clinical improvement in 4 patients. We prospectively computed the coefficient of cross-correlation (MCC) of combined ipsilateral BAEP trials after right and left ear stimulation. In all patients increasing MCC was associated with clinical improvement. Unchanging or decreasing MCC indicated poor outcome.We conclude that serial BAEP studies are an appropriate perioperative monitoring modality in patients with space occupying cerebellar infarcts undergoing decompressive surgery of the posterior fossa.Our study suggests advantages of cross-correlation analysis as an objective signal processing strategy; relevant information can be extracted even if BAEP wave discrimination is impossible due to severe brain-stem dysfunction.  相似文献   

6.
The brain-stem auditory evoked potential (BAEP), a sensitive test of the functional status of the neonatal brain, has not been studied in utero since no practical technique for human fetal recording is available. We have developed a simple recording technique which allows continuous monitoring of the fetal AEP during labor. Waves I, III and V of the fetal brain-stem AEP have been consistently identified. Wave form morphology, interpeak latencies, and latency-intensity relations are similar to postnatal recordings. Middle latency potentials have also been recorded, with wave forms that correspond to the neonatal middle latency AEP.  相似文献   

7.
We studied 54 patients with Behçet's disease, 41 males and 13 females, mean age 28 years. Forty-four patients had auditory brain-stem evoked potential (BAEP) recordings, 39 had pattern reversal visual evoked potentials (VEP), 27 had median nerve somatosensory evoked potential (SEP) recordings, and 25 tibial nerve SEPs. BAEPs were abnormal in 16 patients (52%) with neurological manifestations and in 4 (31%) without, because of decreased amplitude of wave V, prolonged I–III or III–V interpeak latencies, or uncertain/absent waves III and/or V. Eleven patients (40%) with neurological symptoms and 3 patients (25%) without, had abnormal VEPs. Absent potentials, decreased amplitude, with or without prolonged P100 latency, were found in 75% of the cases, the rest had prolonged P100 latency only. Median SEPs were abnormal in 8 patients (38%) with neurological manifestations. Four patients (21%) had abnormal tibial SEPs. Decreased amplitude with or without mild slowing in central conduction was the predominant SEP abnormality. SEPs were normal in all patients without neurological symptoms. In total, 84% of patients with, and 38% of patients without, neurological symptoms had abnormalities of one or more EP modality.When used cautiously, EP studies in Behçet's disease might be helpful to separate neuro-Behçet from other disorders with similar symptomatology, to disclose subclinical CNS involvement, to evaluate and monitor CNS disease activity, and to provide objective measures of treatment response.  相似文献   

8.
The case of a 37-year-old woman with facial myokymia is reported. Magnetic resonance imaging (MRI), electromyography (EMG) and brain-stem auditory evoked potentials (BAEPs) supported the clinical diagnosis of suspected multiple sclerosis (MS). MRI showed a single area of abnormal signal in the pontine region. The authors discuss the possible relationship between the brain-stem lesion and the electrophysiological abnormalities demonstrated by BAEPs and the EMG of facial muscles.  相似文献   

9.
Fourteen adult patients undergoing open heart surgery under induced hypothermia had median nerve, short-latency somatosensory evoked potentials (SSEPs) recorded during cooling (from 36°C to 19°C) and subsequent rewarming. Similar data on another group of patients who had brain-stem auditory evoked potentials (BAEPs) were also analyzed. Hypothermia produced increased latencies of the major SSEP and BAEP components and the latencies returned to normal with subsequent warming. The temperature-latency relationship during the cooling phase was significantly different from that during the warming phase. For SSEP components the temperature-latency relationship was linear during cooling and curvilinear during warming, whereas for BAEP it was curvilinear both during cooling and warming. Furthermore, the regression curves were different during the two phases of temperature manipulation, particularly for temperatures below 30°C both for SSEP and BAEP components. At the onset of warming there was an initial exaggerated warming response on the evoked potential (EP) latencies and amplitude of the EP components. The temperature-latency regression curves were uniformly less steep during the warming phase compared to those during cooling. These findings suggest the existence of hysteresis in the relationship between temperature and EP latencies. The latencies at a given temperature below 30°C depend on whether that temperature is reached during cooling or during warming.  相似文献   

10.
We measured the conduction velocity of the intracranial portion of the auditory nerve in 3 patients undergoing vestibular nerve section to treat Ménière's disease. The conduction velocity varied from patient to patient, with an average value of 15.1 m/sec. The latency of peak III of the brain-stem auditory evoked potentials (BAEPs) increased by an average of 0.5 msec as a result of exposure of the eighth nerve, and if that increase is assumed to affect the entire length of the auditory nerve (2.6 cm) evenly, then the corrected estimate of conduction velocity would be 22.0 m/sec. Estimates of conduction velocity based on the interpeak latencies of peaks I and II of the BAEP, assuming that peak II is generated by the mid-portion of the intracranial segment of the auditory nerve, yielded similar values of conduction velocities (about 20 m/sec).  相似文献   

11.
Neurological function in 159 subjects infected by the human immunodeficiency virus (HIV) who had no neurological symptoms or signs (129 asymptomatic, 30 with ARC/AIDS) was compared to that of 62 controls by means of pattern-reversal evoked potentials (PREPs), brain-stem auditory evoked potentials (BAEPs), median nerve somatosensory evoked potentials (MSEPs), tibial nerve somatosensory evoked potentials (TSEPs) and nerve conduction studies (NCSs). Central nervous system somatosensory conduction from lumbar cord to cortex was prolonged in both asymptomatic seropositive and ARC/AIDS groups, while peripheral somatosensory conduction, NCSs and PREP delays occurred only in the ARC/AIDS group. BAEPs did not show significant differences among groups. TSEPs were abnormal in 8% of asymptomatic carriers and 43% of patients with ARC/AIDS, MSEPs in 7% and 20%, PREPs in 4% and 0%, and BAEPs in 1% and 0% respectively. One or more evoked potentials were abnormal in 18 of 129 (14%) asymptomatic carriers and 13 of 30 (43%) subjects with ARC/AIDS as compared with 1 of 62 (2%) seronegative controls. We conclude that asymptomatic HIV carriers have subclinical neurological impairment of central somatosensory function and that the neurological impairment increases with disease progression to involve peripheral nerves and visual system.  相似文献   

12.
Evoked potential audiometry and brain-stem auditory evoked potentials were evaluated in 15 patients with systemic brucellosis in whom brucella meningitis was suspected clinically. In 8 patients cerebrospinal fluid (CSF) was abnormal with high brucella titre, and evoked potentials were abnormal in all of them. In 7 patients the CSF was normal and evoked potentials were also normal. Brain-stem auditory evoked potential abnormalities were categorised into 4 types: (1) abnormal wave I, (2) abnormal wave V, both irreversible, (3) prolonged I–III interpeak latencies, and (4) prolonged I–V interpeak latencies, both reversible. These findings are of important diagnostic value and correlate well with the clinical features, aetiopathogenesis and final outcome.  相似文献   

13.
Dynamic time warping is a procedure whereby portions of a temporal sequence of values are stretched or shrunk to make it similar to another sequence. This procedure can be used to align the brain-stem auditory evoked potentials recorded from different subjects prior to averaging. The resultant warp-average more closely resembles the wave form of a typical subject than the conventional average. Dynamic time warping can also be used to compare one brain-stem auditory evoked potential to another. This comparison can show the differences that result from changes in a stimulus parameter such as intensity or repetition rate. When a patient's wave form is compared to a normal template, warping can identify the peaks in the patient's wave form that correspond most closely to the peaks in the normal template. Compared to an experienced human interpreter, warping is very accurate in identifying the waves of normal brain-stem auditory evoked potentials (error rate between 0 and 4%) and reasonably accurate in identifying the peaks in abnormal wave forms (error rate between 3 and 18%).  相似文献   

14.
The effects of phenytoin (PHT) on brain-stem auditory evoked potentials (BAEPs) were studied in 65 epileptic patients who received long-term PHT monotherapy at therapeutic and supra-therapeutic levels with no clinical evidence of brain-stem toxicity. Abnormal BAEPs were found in 7.5% and 33.3% of patients with therapeutic and supra-therapeutic PHT levels respectively. Serum PHT levels had a trend towards a positive relationship with the I–V interpeak latency (IPL), and a significant negative relationship with the amplitudes of waves I and V. at supra-therapeutic levels, both I–V and I–III IPLs were significantly prolonged while at therapeutic evels onl I–III IPLs were prolonged. The absolute latency of wave I was prolonged in both the therapeutic and the supra-therapeutic groups. These results suggest that PHT acts both peripherally on either the auditory nerve or the cochlea, and centrally on brain-stem conduction.  相似文献   

15.
Latencies of the brain-stem auditory evoked potentials were observed to increase in subjects whose plasma glucose levels were reduced. These changes appeared to be attributable to reduced body temperature, rather than direct effects of hypoglycemia on the auditory nerve or the brain-stem. The results suggest the need for caution in interpreting evoked potential measurements under hypoglycemia.  相似文献   

16.
Wave VI (8.4 msec) of the brain-stem auditory evoked potential (BAEP) was maximal in a discrete region of primary auditory cortex (AI) of the anesthetized cat. Wave VI underwent rapid amplitude decreas over millimeter distances in the AI region and followed high stimulation rates. Wave VI did not show intracortical polarity inversion nor was it abolished by epicortical or intracortical GABA administration. The data are compatible with a wave VI source in the terminal axons of the thalamo-cortical radiations.Middle latency auditory responses (MAEPs) generated 10–40 msec after auditory stimulation were also recorded in a circumscribed area of AI. In contrast to wave VI, these primary auditory cortex potentials (Pa 18.3 msec; Nb 31.9 msec) underwent transcortical polarity inversion, correlated with intracortical multi-unit activity in the AI region and were reversibly altered or abolished by epicortical or intracortical GABA adminstration to the AI region. The data suggest that the Pa and Nb components of the cat MAEP are intracortically generated by neuronal elements in the AI region.  相似文献   

17.
Short latency evoked potentials following stimulation of the upper lip were recorded intracranially during neurosurgical procedures in 14 patients. In 10 patients, a suboccipital craniectomy provided direct access to the trigeminal root and the pons at the root entry zone. Direct recordings from the trigeminal root were characterized by a large triphasic potential at 2.4–2.7 msec. The latency of this potential increased as a result of moving the recording electrode proximally towards the brain-stem. The same potential could be recorded from the brain-stem surface at a latency suggesting an intra-axial presynaptic origin. A second component, N4.7, was recorded from over the most rostral aspect of the brain-stem in 3 patients and from the tentorium free edge in 4 patients. This potential of smaller amplitude did not show significant difference in latency or polarity at various electrode locations, suggesting a deep diencephalic origin remote from the recording electrode.  相似文献   

18.
The correlations between clinical signs and BAEP latency, amplitude and dispersion variables were investigated in 98 multiple sclerosis patients. A new dispersion variable, the wave IV–V “shape ratio” (SR IV–V), correlated most strongly with brain-stem signs (i.e., nystagmus). Severely reduced wave IV–V amplitude was frequently found in patients with vertical nystagmus or internuclear ophthalmoplegia, and interpeak latency (IPL) III–V correlated most strongly with cerebellar dysfunction (i.e., ataxia). The results may reflect different localizing ability among the various BAEP variables.The association between ataxia and increased IPL III–V was significantly stronger for BAEP to C clicks than to R clicks. Patients with abnormal BAEPs to one polarity (C or R) but not to the other, had significantly more clinical dysfunction than patients with normal BAEPs to both C and R clicks. Hence, C vs. R discordance may be interpreted to indicate possible brain-stem dysfunction.  相似文献   

19.
Three-dimensional brain-stem auditory evoked potentials (3-D BAEPs) were recorded from 12 normal subjects using a new tetrahedral montage, as well as two other bipolar montages previously described for 3-channel Lissajous' trajectories (3-CLTs). Mean responses, as well as between-subject and within-subject variability were described. A mathematical transformation was applied to the recorded trajectories to render them in a common canonical form to test the assumption that the BAEP conforms to a centrally generated dipolar field. Apex, segment, and plane orientations were measured for each trajectory, and discrepancies between montages were evaluated to judge the adequacy of the centered dipole model. For the vector means of apices, segments, and planes, median angles of discrepancy between montages ranged from 10 to 23°. These results support the validity of a centered dipole model for the BAEP and affirm the rationale for employing the 3-channel recording technique. Among the montages studied, the tetrahedron provided maximum economy by using fewer electrodes, avoided certain problematic recording sites, and produced less variable data.  相似文献   

20.
A very short latency trigeminal evoked potential (STEP) to electrical stimulation of the upper lip has been recorded from over the scalp. This potential consists of 5 distinct peaks within the 12 msec range.Normative data were obtained from 25 healthy volunteers. The impact of the stimulus rate and intensity on the response was studied in each subject.These results were compared to those of 19 patients suffering from lesions involving the trigeminal system in its peripheral aspect or the brain-stem. The STEP was consistently abnormal whenever the involved side was stimulated. Changes in peak latencies and in interpeak latency differences (IPLD) correlated well with clinical and radiological findings and improved with the removal of the offending lesion. The STEP proved to be a reliable method for evaluating the trigeminal system in its peripheral and central pathways; it may thus serve as an additional parameter for studying brain-stem functions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号