首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents methods for calculating, for a segment of artery in vivo, (1) viscous and viscoelastic energy dissipation as a function of time, and (2) the viscous and viscoelastic components of the frequency-dependent attenuation coefficient. The calculations require measurement of arterial diameter and of intra-arterial pressure and flow-rate at two sites along the vessel. Viscous energy dissipation is calculated from the radius-dependent velocity shear in the lumen given by linear theory from the pressure measurements. The attenuation coefficient for a given harmonic of heart rate is calculated as half the sum of the viscous and viscoelastic components at that frequency of the energy dissipated per unit length by forwardtravelling waves, divided by the forward-wave flow work input to the segment at that frequency. Measurements in canine carotid arteries indicate that wall viscoelasticity contributes relatively little to energy dissipation per cardiac cycle and pulse wave attenuation.  相似文献   

2.
The pulsatile flow in an anatomically realistic compliant human carotid bifurcation was simulated numerically. Pressure and mass flow waveforms in the carotid arteries were obtained from an individual subject using non-invasive techniques. The geometry of the computational model was reconstructed from magnetic resonance angiograms. Maps of time-average wall shear stress, contours of velocity in the flow field as well as wall movement and tensile stress on the arterial wall are all presented. Inconsistent with previous findings from idealised geometry models, flow in the carotid sinus is dominated by a strong helical flow accompanied by a single secondary vortex motion. This type of flow is induced primarily by the asymmetry and curvature of the in vivo geometry. Flow simulations have been carried out under the rigid wall assumption and for the compliant wall, respectively. Comparison of the results demonstrates the quantitative influence of the vessel wall motion. Generally there is a reduction in the magnitude of wall shear stress, with its degree depending on location and phase of the cardiac cycle. The region of slow or reversed flow was greater, in both spatial and temporal terms in the compliant model, but the global characteristics of the flow and stress patterns remain unchanged. The analysis of mechanical stresses on the vessel surface shows a complicated stress field. Stress concentration occurs at both the anterior and posterior aspects of the proximal internal bulb. These are also regions of low wall shear stress. The comparison of computed and measured wall movement generally shows good agreement.  相似文献   

3.
The presence of atherosclerotic plaques has been shown to be closely related to the vessel geometry. Studies on postmortem human arteries and on the experimental animal show positive correlation between the presence of plaque thickness and low shear stress, departure of unidirectional flow and regions of flow separation and recirculation. Numerical simulations of arterial blood flow and direct blood flow velocity measurements by magnetic resonance imaging (MRI) are two approaches for the assessment of arterial blood flow patterns. In order to verify that both approaches give equivalent results magnetic resonance velocity data measured in a compliant anatomical carotid bifurcation model were compared to the results of numerical simulations performed for a corresponding computational vessel model. Cross sectional axial velocity profiles were calculated and measured for the midsinus and endsinus internal carotid artery. At both locations a skewed velocity profile with slow velocities at the outer vessel wall, medium velocities at the side walls and high velocities at the flow divider (inner) wall were observed. Qualitative comparison of the axial velocity patterns revealed no significant differences between simulations and in vitro measurements. Even quantitative differences such as for axial peak flow velocities were less than 10%. Secondary flow patterns revealed some minor differences concerning the form of the vortices but maximum circumferential velocities were in the same range for both methods.  相似文献   

4.
The aim of this study is to develop and validate a patient-specific distributed model of the systemic arterial tree. This model is built using geometric and hemodynamic data measured on a specific person and validated with noninvasive measurements of flow and pressure on the same person, providing thus a patient-specific model and validation. The systemic arterial tree geometry was obtained from MR angiographic measurements. A nonlinear viscoelastic constitutive law for the arterial wall is considered. Arterial wall distensibility is based on literature data and adapted to match the wave propagation velocity of the main arteries of the specific subject, which were estimated by pressure waves traveling time. The intimal shear stress is modeled using the Witzig-Womersley theory. Blood pressure is measured using applanation tonometry and flow rate using transcranial ultrasound and phase-contrast-MRI. The model predicts pressure and flow waveforms in good qualitative and quantitative agreement with the in vivo measurements, in terms of wave shape and specific wave features. Comparison with a generic one-dimensional model shows that the patient-specific model better predicts pressure and flow at specific arterial sites. These results obtained let us conclude that a patient-specific one-dimensional model of the arterial tree is able to predict well pressure and flow waveforms in the main systemic circulation, whereas this is not always the case for a generic one-dimensional model.  相似文献   

5.
The mechanical behavior of blood vessels is known to be viscoelastic rather than elastic. The functional role of viscoelasticity, however, has remained largely unclear. The hypothesis of this study is that viscoelasticity reduces the stresses and strains in the vessel wall, which may have a significant impact on the fatigue life of the blood vessel wall. To verify the hypothesis, the pulsatile stress in rabbit thoracic artery at physiological loading condition was investigated with a quasi-linear viscoelastic model, where the normalized stress relaxation function is assumed to be isotropic, while the stress-strain relationship is anisotropic and nonlinear. The artery was subjected to the same boundary condition, and the mechanical equilibrium equation was solved for both the viscoelastic and an elastic (which has a constant relaxation function) model. Numerical results show that, compared with purely elastic response, the viscoelastic property of arteries reduces the magnitudes and temporal variations of circumferential stress and strain. The radial wall movement is also reduced due to viscoelasticity. These findings imply that viscoelasticity may be beneficial for the fatigue life of blood vessels, which undergo millions of cyclic mechanical loadings each year of life.  相似文献   

6.
The influence of blood flow on the depositions and development of atherosclerotic lesions have been observed and described since the 19th century. Observations have shown that depositions correlate with regions of low wall shear stress. However, the exact correlations between depositions, vessel geometry and flow parameters are not yet known. The purpose of this study was the quantification of atherosclerosis risk factors in carotid bifurcation. This artery has attracted particular interest because lesions are often found in this bifurcation. Post mortem, the arteries are excised and vessel casts are produced. Afterwards, the arteries are analyzed morphometrically. The vessel casts are used for the assessment of some geometrical parameters. 31 carotid bifurcations were analyzed in this study. Eight vessel casts were digitized and rendered three-dimensional mathematical models of the arteries. These data were imported by the computational fluid dynamics program FLUENT. Further, the blood flow was reconstructed in a computer model based on the individual vessel geometry. The flow parameters, such as velocity, pressure and wall shear stress were computed. At the same time the geometrical parameters and wall alterations are known. This permits the comparison of the anatomical shape and its flow with the distribution and level of the wall alterations.  相似文献   

7.
Arterial blood flow is analyzed on the basis of a realistic model consisting of a viscous liquid contained in a thick-walled viscoelastic tube. Approximate forms of the Navier-Stokes and continuity equations are derived for this model and solved in conjunction with the equations of motion of an elastic solid. Expressions are found for the displacement of the tube wall, velocity distribution, volume flow rate and phase velocity of the pressure wave. Changes in the shape of the pressure wave caused by damping and dispersion are determined, and the effect of viscoelasticity is assessed. Numerical results are presented which correspond to observed parameters of the circulatory systems of living animals.  相似文献   

8.
D N Ku  D Liepsch 《Biorheology》1986,23(4):359-370
To study the fundamentals of hemodynamics in arteries, the flow parameters: pulsatility, elasticity and non-Newtonian viscoelasticity were considered in detail in a 90 degrees-T-bifurcation of a rigid and elastic model. The velocity distribution 2.5 mm behind the bifurcation in the straight tube was measured with a laser-Doppler-anemometer. The fluid used was an aqueous glycerine solution and a viscoelastic Separan mixture. Flow visualization studies were done with a sheet of laser light in the plane of the bifurcation. The velocity distribution was measured for both steady and pulsatile flows with a laser-Doppler-anemometer in a backward scattered way. From the velocity measurements the shear gradients were calculated. Substantial differences were found in the flow behavior of Newtonian and non-Newtonian fluids, especially behind the bifurcation in the main tube, where secondary flows and flow separation started. Also, differences due to the elastic and rigid wall could be seen. Very high shear gradients were found in the flow between main flow and the separation zone which can lead to a damage of the blood cells.  相似文献   

9.
The lymphatic system is an extensive vascular network featuring valves and contractile walls that pump interstitial fluid and plasma proteins back to the main circulation. Immune function also relies on the lymphatic system's ability to transport white blood cells. Failure to drain and pump this excess fluid results in edema characterized by fluid retention and swelling of limbs. It is, therefore, important to understand the mechanisms of fluid transport and pumping of lymphatic vessels. Unfortunately, there are very few studies in this area, most of which assume Poiseuille flow conditions. In vivo observations reveal that these vessels contract strongly, with diameter changes of the order of magnitude of the diameter itself over a cycle that lasts typically 2-3s. The radial velocity of the contracting vessel is on the order of the axial fluid velocity, suggesting that modeling flow in these vessels with a Poiseuille model is inappropriate. In this paper, we describe a model of a radially expanding and contracting lymphatic vessel and investigate the validity of assuming Poiseuille flow to estimate wall shear stress, which is presumably important for lymphatic endothelial cell mechanotransduction. Three different wall motions, periodic sinusoidal, skewed sinusoidal and physiologic wall motions, were investigated with steady and unsteady parabolic inlet velocities. Despite high radial velocities resulting from the wall motion, wall shear stress values were within 4% of quasi-static Poiseuille values. Therefore, Poiseuille flow is valid for the estimation of wall shear stress for the majority of the lymphangion contractile cycle.  相似文献   

10.
The inverse Womersley problem for pulsatile flow in straight rigid tubes   总被引:2,自引:0,他引:2  
In this study a numerical solution for the problem of pulsating flow in rigid tubes is described. The method applies to the case of known flow rate waveform, as opposed to Womersley solution where the pressure gradient was the known quantity. The solution provides the pressure gradient and wall shear stress waveforms as well as the instantaneous velocity profiles. Results show that the method can be used to study the blood flow characteristics in large arteries.  相似文献   

11.
The theoretical predictions described in part I of this study are compared with in vivo data from anesthetized dogs. It is shown that the observed attenuation of the pressure and axial waves cannot be accounted for by fluid viscosity alone. For large values of the frequency parameter α = √ρωR20/μ, the analysis of part I is extended to include the effects of viscoelasticity of the vessel wall. The results indicate that the speeds of both types of waves are essentially not affected by a realistic viscoelasticity model while the attenuation per wavelength is significantly increased and becomes frequency independent. The application of this analysis to in vivo data from the carotid arteries of anesthetized dogs demonstrates partial agreement between theory and experiment and suggests that the carotid arteries are anisotropically viscoelastic.  相似文献   

12.
A theoretical analysis for the problem of wave propagation in arteries is presented. Blood is treated as a Newtonian, viscous incompressible fluid. On the basis of information derived from experimental investigations on the mechanical properties of wall tissues, the arterial wall is considered to be nonlinearly viscoelastic and orthotropic. The analysis is carried out for a cylindrical artery, under the purview of membrane theory, by taking account the effect of initial stresses. The motion of the wall and that of the fluid are assumed to be axisymmetric. Particular emphasis has been paid to the propagation of small amplitude harmonic waves whose wavelength is large compared to the radius of the vessel. By employing the equations of motion of the fluid and those for the wall, together with the equations of continuity, a frequency equation is derived by exploiting the conditions of continuity of the velocity of the arterial wall and that of blood on the endosteal surface of the wall. In order to illustrate the validity of the derived analytical expressions a quantitative analysis is made for the variations of the phase velocities as well as the transmission coefficient with frequency corresponding to different transmural pressures which relate to different initial stresses. Computational results indicate that phase velocities increase with the increase of transmural pressures.  相似文献   

13.
Porcine blood was used to examine the relationship between hematocrit levels and wall shear rate patterns in straight and curved artery models under fixed oscillatory flow conditions characteristic of larger arteries. It is demonstrated that porcine blood models both the viscous and elastic components of the 2 Hz complex viscosity of human blood quite accurately over a broad range of shear rates (1-1000 s-1) and hematocrits (20%-80%). For a fixed oscillatory flow waveform (Poiseuille peak shear rate = 168 s-1; mean shear rate 84 s-1), increases in hematocrit produced a decrease in the peak wall shear rate in both the straight and curved artery models and a corresponding decrease in wall shear rate reversal on the inside wall of the curved artery model. The same trends were also observed for oscillatory flows of aqueous glycerin solutions of increasing viscosity in the range of viscosity of the blood samples tested. Aqueous glycerin solutions produced wall shear rate waveforms of the same magnitude and shape as the porcine blood. This indicates that variations in the shear rate, and therefore the shear stress, were caused primarily by changes in the viscous and not the elastic properties of blood. The results suggest that simple Newtonian fluids may be sufficient for in vitro determination of the first order effects to be expected of human blood flow in large vessels having complex geometries and shear rates in or above the range of the present study.  相似文献   

14.
The propagation of harmonic pressure waves through a Newtonian fluid contained within a thick-walled, viscoelastic tube is considered as a model of arterial blood flow. The fluid is assumed to be homogeneous and Newtonian, and its motion to be laminar and axisymmetric. The wall is assumed to be isotropic, incompressible, linear, and viscoelastic. It is also assumed that the motion is such that the convective acceleration is negligible. The motion of the fluid is described by the linearized form of the Navier-Stokes equations and the motion of the wall by classical elasticity theory. The frequency dependence of the wall mechanical properties are represented by a three parameter, relaxation-type model. Using boundary conditions describing the continuity of stress and velocity components in the fluid and the wall, explicit solutions for the system of equations of the model have been obtained. The longitudinal fluid impedance has been expressed in terms of frequency and the system parameters. The frequency equation has been solved and the propagation constant also expressed in terms of frequency and system parameters. The results indicate that the fluid impedance is smaller than predicted by the rigid tube model or by Womersley''s constrained elastic tube model. Also, the velocity of propagation is generally slower and the transmission per wavelength less than predicted by Womersley''s elastic tube model. The propagation constant is very sensitive to changes in the degree of wall viscoelasticity.  相似文献   

15.
16.
The infrarenal abdominal aorta is a common site for clinically significant atherosclerosis. As has been shown in other susceptible locations, vessel geometry, flow division rates, and pulsatility may result in hemodynamic conditions which influence the preferential localization of disease in the abdominal aorta segment. Pulsatile flow visualization was performed in a glass model of the aorta constructed from measurements of angiograms and cadaver aortas. Flow rates and pulsatile waveforms were varied to reflect typical physiological conditions. Under normal resting conditions, the flow patterns in the infrarenal aorta were more complex than those in the suprarenal location. Time varying vortex patterns appeared at the level of the renal arteries and propagated through the infrarenal aorta into the common iliac arteries. A region of oscillating velocity direction extended from the renal arteries to the aortic bifurcation along the posterior wall. Dye became trapped along the posterior wall, requiring several cardiac cycles for clearance. In contrast, there was rapid clearance of the dye in the anterior aorta. Under postprandial conditions, the flow patterns in the aorta were basically unchanged. Simulated exercise conditions created laminar hemodynamic features very different from the resting conditions, including a decrease in dye residence time. This study reveals significant time-dependent variations in the hemodynamics of the abdominal aorta under differing physiologic conditions. Hemodynamic factors such as low wall shear stress, oscillating shear direction, and high particle residence time may be related to the clinically seen preferential plaque localization in the infrarenal aorta.  相似文献   

17.
To give a realistic representation of the pulse propagation in arteries a theoretical analysis of the wave propagation through a viscous incompressible fluid contained in an initially stressed elastic tube is considered. The tube is assumed to be orthotropic and its longitudinal motion is constrained by a uniformly distributed additional mass, a dashpot and a spring. The fluid is assumed to be Newtonian. The analysis is restricted to propagation of small amplitude harmonic waves whose wavelength is large compared to the radius of the vessel. Elimination of arbitrary constants from the general solutions of the equations of motion of the fluid and the wall gives a frequency equation to determine the velocity of propagation. Two roots of this equation give the velocity of propagation of two distinct outgoing waves. One of the waves propagates slower than the other. The propagation properties of s lower waves are very slightly affected by the degree of anisotropy of the wall. The velocity of propagation of faster waves decreases as the ratio of the longitudinal modulus of elasticity to the circumferential modulus decreases; transmission of these waves is very little affected. The influence of the tethering on the propagation velocity of slower waves is negligibly small; transmission of these waves is seriously affected. In tethered tubes faster waves are completely attenuated.  相似文献   

18.
Tortuous aneurysmal arteries are often associated with a higher risk of rupture but the mechanism remains unclear. The goal of this study was to analyze the buckling and post-buckling behaviors of aneurysmal arteries under pulsatile flow. To accomplish this goal, we analyzed the buckling behavior of model carotid and abdominal aorta with aneurysms by utilizing fluid-structure interaction (FSI) method with realistic waveforms boundary conditions. FSI simulations were done under steady-state and pulsatile flow for normal (1.5) and reduced (1.3) axial stretch ratios to investigate the influence of aneurysm, pulsatile lumen pressure and axial tension on stability. Our results indicated that aneurysmal artery buckled at the critical buckling pressure and its deflection nonlinearly increased with increasing lumen pressure. Buckling elevates the peak stress (up to 118%). The maximum aneurysm wall stress at pulsatile FSI flow was (29%) higher than under static pressure at the peak lumen pressure of 130 mmHg. Buckling results show an increase in lumen shear stress at the inner side of the maximum deflection. Vortex flow was dramatically enlarged with increasing lumen pressure and artery diameter. Aneurysmal arteries are more susceptible than normal arteries to mechanical instability which causes high stresses in the aneurysm wall that could lead to aneurysm rupture.  相似文献   

19.
Theoretical and experimental evidence suggests that the dissipation of high frequency pressure waves in blood vessels is caused primarily by the viscoelastic behavior of the vessel wall. In this theoretical analysis the vessels are considered as fluid-filled circular cylindrical shells whose walls have isotropic and homogeneous viscoelastic properties and are subjected to an initial axial stretch and a transmural pressure. If the wall material is incompressible and behaves as a Voigt solid in shear, the results predict a decrease in wave amplitude per wavelength which is essentially independent of frequency over a wide range. This finding is in qualitative agreement with recent experiments on anesthetized dogs. A parametric study also shows a great sensitivity of the dissipation to changes in transmural pressure and axial stretch. Axisymmetric waves are only mildly dispersive, while all nonaxisymmetric waves are highly dispersive and exhibit much stronger damping per wavelength at low frequencies than do axisymmetric waves.  相似文献   

20.
Arterial blood flow is analyzed on the basis of a realistic model consisting of a viscous liquid contained in a thick-walled viscoelastic tube. Approximate forms of the Navier-Stokes and continuity equations are derived for this model and solved in conjunction with the equations of motion of an elastic solid. Expressions are found for the displacement of the tube wall, velocity distribution, volume flow rate and phase velocity of the pressure wave. Changes in the shape of the pressure wave caused by damping and dispersion are determined, and the effect of viscoelasticity is assessed. Numerical results are presented which correspond to observed parameters of the circulatory systems of living animals. This research was partially supported by the National Science Foundation; it was done in part by D. K. Whirlow in partial fulfillment of the requirements for the degree of Doctor of Philosophy at the Carnegie Institute of Technology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号