首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
IntroductionThe Dutch general population is aging rapidly. Many of these patient are fit and eligible for TAVR. However, studies on outcome in older versus younger patients are scant.Material and methodsA single-centre retrospective study comparing patients older and younger than age 85 on outcome.Results190 patients underwent TAVR: 136 were aged 85 or younger (U85), 54 were older than 85 (O85). The U85 group had more men (U85: 71 [52.2%] vs O85: 19 [35.2%]; p = 0.034), a higher incidence of diabetes (U85: 36 [26.5%] vs O85: 3 [5.6%]; p = 0.001) and atrial fibrillation (U85: 35 [25.7%] vs O85: 5 [9.3%]; p = 0.03) and a higher body mass index (U85: 27.5 [± 5.24] vs O85: 26 [± 3.78]; p = 0.027). In the O85 group there was a lower estimated glomerular filtration rate (O85: 50.28 [± 15.32] ml/min vs U85: 65.25 [± 29.97] ml/min; p = 0.012). There was no difference in 30-day mortality (U85: 6 [4.4%] vs O85: 3 [5.6%]) and 1‑year mortality (U85 9 [6.6%] vs O85 3 [5.6%]) (p = 0.521). There was an equal amount of new onset permanent left bundle branch block (U85: 38 [27.9%] vs O85: 14 [25.9%]; p = 0.896) and permanent pacemaker implantation (U85: 28 [20.6%] vs O85: 28 [20.6%]; p = 0.748). There was no difference in bleeding events (p = 0.469), vascular complications (p = 0.195) or moderate/severe regurgitation (p = 0.972). The U85 group had a slightly longer admission duration (U85 6.29 [± 5.289] days vs O85 5.98 [± 3.328] days (p = 0.037)).ConclusionTAVR in patients over 85 years of age has excellent outcome, comparable to those aged 85 and younger.  相似文献   

2.
IntroductionTranscatheter aortic valve implantation (TAVI) has matured to the treatment of choice for most patients with aortic stenosis (AS). We sought to identify trends in patient and procedural characteristics, and clinical outcomes in all patients who underwent TAVI between 2005 and 2020.MethodsA single-centre analysis was performed on 1500 consecutive patients who underwent TAVI, divided into three tertiles (T) of 500 patients treated between November 2005 and December 2014 (T1), January 2015 and May 2018 (T2) and June 2018 and April 2020 (T3).ResultsOver time, mean age and gender did not change (T1 to T3: 80, 80 and 79 years and 53%, 55% and 52% men, respectively), while the Society of Thoracic Surgeons risk score declined (T1: 4.5% to T3: 2.7%, p < 0.001). Use of general anaesthesia also declined over time (100%, 24% and 1% from T1 to T3) and transfemoral TAVI remained the default approach (87%, 94% and 92%). Median procedure time and contrast volume decreased significantly (186, 114 and 56 min and 120, 100 and 80 ml, respectively). Thirty-day mortality (7%, 4% and 2%), stroke (7%, 3% and 3%), need for a pacemaker (19%, 22% and 8%) and delirium (17%, 12% and 8%) improved significantly, while major bleeding/vascular complications did not change (both approximately 9%, 6% and 6%). One-year survival was 80%, 88% and 92%, respectively.ConclusionOver our 15 years’ experience, patient age remained unchanged but the patient risk profile became more favourable. Simplification of the TAVI procedure occurred in parallel with major improvement in outcomes and survival. Bleeding/vascular complications and the need for pacemaker implantation remain the Achilles’ heel of TAVI.Supplementary InformationThe online version of this article (10.1007/s12471-022-01662-2) contains supplementary material, which is available to authorized users.  相似文献   

3.
IntroductionNew-onset left bundle branch block (LBBB) following transcatheter or surgical aortic valve replacement (LBBBAVI) implies a proximal pathogenesis of LBBB. This study compares electrocardiographic characteristics and concordance with LBBB definitions between LBBBAVI and non-procedure-induced LBBB controls (LBBBcontrol).MethodsAll LBBBAVI patients at Ghent University Hospital between 2013 and 2019 were enrolled in the study. LBBBAVI patients were matched for age, sex, ischaemic heart disease and ejection fraction to LBBBcontrol patients in a 1:2 ratio. For inclusion, a non-strict LBBB definition was used (QRS duration ≥ 120 ms, QS or rS in V1, absence of Q waves in V5-6). Electrocardiograms were digitally analysed and classified according to three LBBB definitions: European Society of Cardiology (ESC), Strauss and American Heart Association (AHA).ResultsA total of 177 patients (59 LBBBAVI and 118 LBBBcontrol) were enrolled in the study. LBBBAVI patients had more lateral QRS notching/slurring (100% vs 85%, p = 0.001), included a higher percentage with a QRS duration ≥ 130 ms (98% vs 86%, p = 0.007) and had a less leftward oriented QRS axis (−15° vs −30°, p = 0.013) compared to the LBBBcontrol group. ESC and Strauss criteria were fulfilled in 100% and 95% of LBBBAVI patients, respectively, but only 18% met the AHA criteria. In LBBBcontrol patients, concordance with LBBB definitions was lower than in the LBBBAVI group: ESC 85% (p = 0.001), Strauss 68% (p < 0.001) and AHA 7% (p = 0.035). No differences in electrocardiographic characterisation or concordance with LBBB definitions were observed between LBBBAVI and LBBBcontrol patients with lateral QRS notching/slurring.ConclusionNon-uniformity exists among current LBBB definitions concerning the detection of proximal LBBB. LBBBAVI may provide a framework for more consensus on defining proximal LBBB.Supplementary InformationThe online version of this article (10.1007/s12471-021-01565-8) contains supplementary material, which is available to authorized users.  相似文献   

4.
IntroductionThe coronavirus disease 2019 (COVID-19) pandemic has put tremendous pressure on healthcare systems. Most transcatheter aortic valve implantation (TAVI) centres have adopted different triage systems and procedural strategies to serve highest-risk patients first and to minimise the burden on hospital logistics and personnel. We therefore assessed the impact of the COVID-19 pandemic on patient selection, type of anaesthesia and outcomes after TAVI.MethodsWe used data from the Netherlands Heart Registration to examine all patients who underwent TAVI between March 2020 and July 2020 (COVID cohort), and between March 2019 and July 2019 (pre-COVID cohort). We compared patient characteristics, procedural characteristics and clinical outcomes.ResultsWe examined 2131 patients who underwent TAVI (1020 patients in COVID cohort, 1111 patients in pre-COVID cohort). EuroSCORE II was comparable between cohorts (COVID 4.5 ± 4.0 vs pre-COVID 4.6 ± 4.2, p = 0.356). The number of TAVI procedures under general anaesthesia was lower in the COVID cohort (35.2% vs 46.5%, p < 0.001). Incidences of stroke (COVID 2.7% vs pre-COVID 1.7%, p = 0.134), major vascular complications (2.3% vs 3.4%, p = 0.170) and permanent pacemaker implantation (10.0% vs 9.4%, p = 0.634) did not differ between cohorts. Thirty-day and 150-day mortality were comparable (2.8% vs 2.2%, p = 0.359 and 5.2% vs 5.2%, p = 0.993, respectively).ConclusionsDuring the COVID-19 pandemic, patient characteristics and outcomes after TAVI were not different than before the pandemic. This highlights the fact that TAVI procedures can be safely performed during the COVID-19 pandemic, without an increased risk of complications or mortality.Supplementary InformationThe online version of this article (10.1007/s12471-022-01704-9) contains supplementary material, which is available to authorized users.  相似文献   

5.
Coronary obstruction is a life threatening complication during and post-transcatheter aortic valve replacement (TAVR). The objective of this preliminary work is to investigate the mechanisms underlying coronary obstruction in a patient after TAVR, in whom coronary obstruction was confirmed in addition to highlighting the importance of pre-procedural planning. The aortic root of an 80-year old male patient with coronary obstruction during TAVR–where a 29 mm SAPIEN 3 was deployed-was segmented from Computed Tomography scans and 3D-printed with compliant material. Flow and pressure data were acquired in this 3D-printed model in-vitro using a pulse duplicator under physiological conditions for the cases: a 29 mm SAPIEN 3, a 26 mm SAPIEN 3 expanded with a 29 mm balloon, and a 31 mm Medtronic-CoreValve deployed annularly, supra and sub-annularly respectively. Only the CoreValve in sub-annular axial position and the 29 mm SAPIEN 3 yielded pressure gradients (PG) lower than 10 mmHg (6.76 ± 0.52 and 5.72 ± 0.13 mmHg respectively) while the 26 mm SAPIEN 3, CoreValve in normal and supra-annular positions yielded higher PGs (15.5 ± 0.48, 12.2 ± 0.15 and 10.8 ± 0.24 mmHg respectively). 29 mm SAPIEN 3 implantation yielded an FFR value of 45.7 ± 0.6%. However, 31 mm CoreValve in any of the three different annular positions yielded FFR values going from 89.6 ± 1.1% in supra-annular position to 98.3 ± 1.1% in sub-annular position. Implantation with a 26 mm SAPIEN 3 expanded with a 29 mm balloon also yielded an FFR of 92.1 ± 1.2%. Coronary obstruction in this patient could have been prevented through usage of different valve types and/or through usage of a different combination of valve size-balloon sizes.  相似文献   

6.
BackgroundThe COVID-19 pandemic has led to a national lockdown in the Netherlands, which also affected transcatheter aortic valve implantation (TAVI) patients. The objective of the study was to describe physical activity, dietary intake and quality of life (QoL) in patients on the waiting list for TAVI pre-lockdown and during lockdown.MethodsConsecutive patients awaiting TAVI at the Amsterdam University Medical Centers, the Netherlands were included. Measurements were self-reported effect of lockdown, physical activity, dietary intake and QoL.ResultsIn total, 58 patients (median age 80, interquartile range (IQR) 76–84, 45% female) were observed pre-lockdown and 16 patients (median age 78, IQR 76–82, 25% female) during lockdown. Ten of the 16 patients during lockdown reported a decline in physical activity. However, we observed a median number of 5861 steps a day (IQR 4579–7074) pre-lockdown and 8404 steps a day (IQR 7653–10,829) during lockdown. Median daily protein intake was 69 g (IQR 59–82) pre-lockdown and 90 g (IQR 68–107) during lockdown. Self-rated health on a visual analogue scale was 63 points (IQR 51–74) pre-lockdown and 73 points (IQR 65–86) during lockdown.ConclusionsMore than half of the patients during lockdown reported less physical activity, while we observed a higher number of steps a day, a similar dietary intake and a higher QoL. Therefore, patients on the TAVI waiting list appeared to be able to cope with the lockdown measures.  相似文献   

7.
Patient-specific computational models are an established tool to support device development and test under clinically relevant boundary conditions. Potentially, such models could be used to aid the clinical decision-making process for percutaneous valve selection; however, their adoption in clinical practice is still limited to individual cases. To be fully informative, they should include patient-specific data on both anatomy and mechanics of the implantation site. In this work, fourteen patient-specific computational models for transcatheter aortic valve replacement (TAVR) with balloon-expandable Sapien XT devices were retrospectively developed to tune the material parameters of the implantation site mechanical model for the average TAVR population.Pre-procedural computed tomography (CT) images were post-processed to create the 3D patient-specific anatomy of the implantation site. Balloon valvuloplasty and device deployment were simulated with finite element (FE) analysis. Valve leaflets and aortic root were modelled as linear elastic materials, while calcification as elastoplastic. Material properties were initially selected from literature; then, a statistical analysis was designed to investigate the effect of each implantation site material parameter on the implanted stent diameter and thus identify the combination of material parameters for TAVR patients.These numerical models were validated against clinical data. The comparison between stent diameters measured from post-procedural fluoroscopy images and final computational results showed a mean difference of 2.5 ± 3.9%. Moreover, the numerical model detected the presence of paravalvular leakage (PVL) in 79% of cases, as assessed by post-TAVR echocardiographic examination.The final aim was to increase accuracy and reliability of such computational tools for prospective clinical applications.  相似文献   

8.
Halim  J.  Missault  L.  Lycke  M.  Van der Heyden  J. 《Netherlands heart journal》2020,28(12):639-644
Objectives

The present study aims to evaluate the efficacy and safety of the MANTA vascular closure device (VCD) (Teleflex, Morrisville, NC, USA) in transfemoral transcatheter aortic valve replacement (TF-TAVR).

Background

To close the femoral artery in TF-TAVR a VCD is the treatment of choice. Data involving suture-based VCDs have been extensive. Although scarce, results on the MANTA device are promising. There is no consensus yet as to whether the MANTA device is associated with fewer access-site-related vascular/bleeding complications when compared to suture-based VCDs.

Methods

In this prospective single-arm study, performed at a single centre, a total of 73 patients eligible for TF-TAVR were included and consecutively treated with the MANTA device.

Results

Access-site-related vascular complications were seen in 13.7% of patients treated with the MANTA device. In this group of patients only minor vascular complications were observed. Access-site-related bleeding complications were rare (6.8%), and device failure was seen in 13.7% of the patients.

Conclusions

This single-centre study confirms that use of the MANTA device in TF-TAVR is feasible with an acceptable rate of access-site-related complications and no major vascular complications.

  相似文献   

9.
Purpose: Elevated carbohydrate antigen 125 (CA125) predicts adverse outcome after transcatheter aortic valve implantation (TAVI). While known underlying pathophysiological mechanisms of elevated CA125 include serosal effusions and inflammatory stimuli, clinical determinants associated with elevated CA125 in patients referred for TAVI remain unknown. Therefore, we investigated clinical, laboratory and echocardiographic determinants of elevated CA125 in patients with severe aortic valve stenosis referred for TAVI.

Methods: This study includes 650 patients with severe aortic stenosis referred for TAVI. Baseline CA125 was determined by an immunoassay and dichotomized (elevated versus normal) based on the manufacturer cutoff value (>35?U/mL).

Results: CA125 elevation was present in 28% (181/650). Patients with elevated CA125 had an overall worse clinical profile and were more symptomatic with a higher rate of NYHA class III/IV (80% versus 58%; p?Conclusion: Elevated CA125 levels in patients referred for TAVI summarize a subset of patients with an overall worse clinical profile who are more symptomatic.  相似文献   

10.

Background

Although CT-studies as well as intraoperative analyses have described broad anatomic variations of the aortic annulus, which is predominantly found non-circular, commercially available transcatheter aortic heart valve prostheses are circular. In this study, we hypothesize that the in vitro hydrodynamic function of a self-expanding transcatheter heart valve (Medtronic CoreValve®) assessed in an oval compartment representing the aortic annulus will differ from the conventionally used circular compartment.

Methods

Medtronic CoreValve® prostheses were tested in specifically designed and fabricated silicone compartments with three degrees of defined ovalities. The measurements were performed in a left heart simulator at three different flow rates. In this setting, regurgitation flow, effective orifice area, and systolic pressure gradient across the valve were determined. In addition, high speed video recordings were taken to investigate leaflet kinematics.

Results

The pressure difference across the prosthesis increased with rising ovality. The effective orifice areas were only slightly impacted. The analyses of the regurgitation showed minor changes and partially lower regurgitation when switching from round to slightly oval settings, followed by strong increases for further ovalization. The high speed videos show minor central leakage and impaired leaflet apposition for strong ovalities, but no leaflet/stentframe contact in any setting.

Conclusion

This study quantifies the influence of oval expansion of transcatheter heart valve prostheses on their hydrodynamic performance. While slight ovalities were well tolerated by a self-expanding prosthesis, more significant ovality led to worsening of prosthesis function and regurgitation.  相似文献   

11.
Until recently, heart valve failure has been treated adopting open-heart surgical techniques and cardiopulmonary bypass. However, over the last decade, minimally invasive procedures have been developed to avoid high risks associated with conventional open-chest valve replacement techniques. Such a recent and innovative procedure represents an optimal field for conducting investigations through virtual computer-based simulations: in fact, nowadays, computational engineering is widely used to unravel many problems in the biomedical field of cardiovascular mechanics and specifically, minimally invasive procedures. In this study, we investigate a balloon-expandable valve and we propose a novel simulation strategy to reproduce its implantation using computational tools. Focusing on the Edwards SAPIEN valve in particular, we simulate both stent crimping and deployment through balloon inflation. The developed procedure enabled us to obtain the entire prosthetic device virtually implanted in a patient-specific aortic root created by processing medical images; hence, it allows evaluation of postoperative prosthesis performance depending on different factors (e.g. device size and prosthesis placement site). Notably, prosthesis positioning in two different cases (distal and proximal) has been examined in terms of coaptation area, average stress on valve leaflets as well as impact on the aortic root wall. The coaptation area is significantly affected by the positioning strategy ( ? 24%, moving from the proximal to distal) as well as the stress distribution on both the leaflets (+13.5%, from proximal to distal) and the aortic wall ( ? 22%, from proximal to distal). No remarkable variations of the stress state on the stent struts have been obtained in the two investigated cases.  相似文献   

12.
Abstract

Background: In this study we sought to examine whether transcatheter aortic valve implantation (TAVI) is followed by a change in the plasma levels of novel cardiovascular biomarkers.

Methods: We collected blood samples of 79 patients with severe aortic valve stenosis undergoing TAVI before and at 7 days, 1 month, 3 months and 6 months post TAVI and analyzed the plasma concentrations of GDF-15, H-FABP, fetuin-A, galectin 3, sST2 and suPAR by means of ELISA.

Results: There was a significant increase in the concentration of fetuin-A (median: 52.44 mg/ml to 113.2 mg/ml, p?<?0.001) and a significant decrease of H–FABP after TAVI (median: 4.835 ng/ml to 2.534 ng/ml, p?<?0.001). The concentrations of suPAR and sST2 showed an initial increase (suPAR median: 2755 pg/ml 3489 pg/ml, p?<?0.001; sST2 median: 5832 pg/ml to 7137 pq/ml, p?<?0.001) and subsequently decreased significantly.

Conclusion: We hypothesize that the decrease of H-FABP and the increase of fetuin-A could be due to a hemodynamic improvement after valve replacement. The initial increase of suPAR could indicate an inflammatory stimulus and the significant increase in sST2 could be due to the mechanical strain caused by implantation of the valve.  相似文献   

13.
AimTo provide insight into the basic characteristics of decision making in the treatment of symptomatic severe aortic stenosis (SSAS) in Dutch heart centres with specific emphasis on the evaluation of frailty, cognition, nutritional status and physical functioning/functionality in (instrumental) activities of daily living [(I)ADL].MethodsA questionnaire was used that is based on the European and American guidelines for SSAS treatment. The survey was administered to physicians and non-physicians in Dutch heart centres involved in the decision-making pathway for SSAS treatment.ResultsAll 16 Dutch heart centres participated. Before a patient case is discussed by the heart team, heart centres rarely request data from the referring hospital regarding patients’ functionality (n = 5), frailty scores (n = 0) and geriatric consultation (n = 1) as a standard procedure. Most heart centres ‘often to always’ do their own screening for frailty (n = 10), cognition/mood (n = 9), nutritional status (n = 10) and physical functioning/functionality in (I)ADL (n = 10). During heart team meetings data are ‘sometimes to regularly’ available regarding frailty (n = 5), cognition/mood (n = 11), nutritional status (n = 8) and physical functioning/functionality in (I)ADL (n = 10). After assessment in the outpatient clinic patient cases are re-discussed ‘sometimes to regularly’ in heart team meetings (n = 10).ConclusionsDutch heart centres make an effort to evaluate frailty, cognition, nutritional status and physical functioning/functionality in (I)ADL for decision making regarding SSAS treatment. However, these patient data are not routinely requested from the referring hospital and are not always available for heart team meetings. Incorporation of these important data in a structured manner early in the decision-making process may provide additional useful information for decision making in the heart team meeting.Supplementary InformationThe online version of this article (10.1007/s12471-022-01676-w) contains supplementary material, which is available to authorized users.  相似文献   

14.

Background

Although symptomatic patients with severe aortic stenosis have a high disease burden and guidelines recommend aortic valve replacement, many are treated conservatively. This study describes to what extent quality of life is changed by aortic valve replacement relative to conservative treatment.

Methods

This observational study followed 132 symptomatic patients with severe aortic stenosis who were subjected to an SF-36v2TM Health Survey.

Results

At baseline 84 patients were treated conservatively, 48 were referred for aortic valve replacement. In the conservatively treated group 15 patients died during a mean follow-up of 18 months (Kaplan-Meier survival was 85 % and 72 % at one and 2 years respectively) and 22 patients crossed over to the surgical group. Of the resulting 70 patients in the surgical group 3 patients died during a mean follow-up of 11 months (survival 95 % at 1 year). Physical functioning, vitality and general health improved significantly 1 year after aortic valve replacement. In conservatively treated patients physical quality of life deteriorated over time while general health, vitality and social functioning showed a declining trend. Mental health remained stable in both groups.

Conclusions

Aortic valve replacement improves physical quality of life, general health and vitality in patients with symptomatic severe aortic stenosis. Besides having a low life expectancy, conservatively treated patients experience deterioration of physical quality of life. Health surveys such as the SF-36v2TM can be valuable tools in monitoring the burden of disease for an individual patient and offer additional help in treatment decisions.  相似文献   

15.
IntroductionHeart failure (HF) poses a burden on specialist care, making referral of clinically stable HF patients to primary care a desirable goal. However, a structured approach to guide patient referral is lacking.MethodsThe Maastricht Instability Score—Heart Failure (MIS-HF) questionnaire was developed to objectively stratify the clinical status of HF patients: patients with a low MIS-HF (0–2 points, indicating a stable clinical condition) were considered for treatment in primary care, whereas high scores (> 2 points) indicated the need for specialised care. The MIS-HF was evaluated in 637 consecutive HF patients presenting between 2015 and 2018 at Maastricht University Medical Centre.ResultsOf the 637 patients, 329 (52%) had a low score and 205 of these 329 (62%) patients were referred to primary care. The remaining 124 (38%) patients remained in secondary care. Of the 308 (48%) patients with a high score (> 2 points), 265 (86%) remained in secondary care and 41 (14%) were referred to primary care. The primary composite endpoint (mortality, cardiac hospital admissions) occurred more frequently in patients with a high compared to those with a low MIS-HF after 1 year of follow-up (29.2% vs 10.9%; odds ratio (OR) 3.36, 95% confidence interval (CI) 2.20–5.14). No significant difference in the composite endpoint (9.8% vs 12.9%; OR 0.73, 95% CI 0.36–1.47) was found between patients with a low MIS-HF treated in primary versus secondary care.ConclusionThe MIS-HF questionnaire may improve referral policies, as it helps to identify HF patients that can safely be referred to primary care.Supplementary InformationThe online version of this article (10.1007/s12471-021-01654-8) contains supplementary material, which is available to authorized users.  相似文献   

16.
ObjectivesThe aim of this study is to evaluate device size selection in patients within the borderline annulus size range undergoing transcatheter aortic valve replacement (TAVR) and to assess if pre-procedural patient-specific computer simulation will lead to the selection of a different device size than standard of care.BackgroundIn TAVR, appropriate device sizing is imperative. In borderline annulus size cases no standardised technique for tailored device size selection is currently available. Pre-procedural patient-specific computer simulation can be used, predicting the risk for paravalvular leakage (PVL) and need for permanent pacemaker implantation (PPI).MethodsIn this multicentre retrospective study, 140 patients in the borderline annulus size range were included. Hereafter, device size selection was left to the discretion of the operator. After TAVR, in 24 of the 140 patients, patient-specific computer simulation calculated the most appropriate device size expected to give the lowest risk for PVL and need for PPI. In these 24 patients, device size selection based on patient-specific computer simulation was compared with standard-of-care device size selection relying on a standardised matrix (Medtronic).ResultsIn a significant proportion of the 140 patients (26.4%) a different device size than recommended by the matrix was implanted. In 10 of the 24 patients (41.7%) in whom a computer simulation was performed, a different device size was recommended than by means of the matrix.ConclusionsDevice size selection in patients within the borderline annulus size range is still ambiguous. In these patients, patient-specific computer simulation is feasible and can contribute to a more tailored device size selection.  相似文献   

17.
Objective. To report the feasibility, safety and efficacy of percutaneous aortic valve implantation (PAVI) with the CoreValve self-expanding aortic valve bioprosthesis in elderly patients with aortic valve stenosis who are rejected for surgery or have a high surgical risk.Methods. PAVI using the CoreValve ReValving System was performed under general anaesthesia in 30 high-risk (surgical) patients with a symptomatic severe aortic valve stenosis.Results. The patients had a mean age of 80.5±7.7 years, a mean aortic valve area of 0.71±0.19 cm2, a peak transvalvular aortic gradient of 79±25 mmHg, as measured with echo Doppler, a logistic EuroSCORE of 15±10% and a Society of Thoracic Surgeons (STS) score of 5.2±2.9%. Device success was achieved in all patients and acute procedural success in 27 patients (90%). In the surviving patients, there was in a reduction of the peak aortic pressure gradient from 76±24 mmHg to 22±7 mmHg (n=24, p<0.00001) 30 days after successful device implantation. At 30 days, major adverse cardiovascular and cerebral events had occurred in seven patients (23%). This included mortality in six patients (20%), of which one death was cardiovascular. The other five non-cardiovascular deaths involved two patients who died of an exacerbation of severe pre-existent pulmonary disease and three of infectious complications.Conclusions. Percutaneous aortic valve implantation was successfully performed in our centre in highrisk patients, with a 30-day mortality of 20%. When successful, marked haemodynamic improvement and relief of symptoms was achieved. (Neth Heart J 2010;18:18-24.)  相似文献   

18.
Wen  Jun  Gao  Qi  Chen  Jingnan  Li  Xinya  Zhang  Kaiyue  He  Gang  Dai  Min  Song  Pan 《Biomechanics and modeling in mechanobiology》2023,22(4):1379-1394
Biomechanics and Modeling in Mechanobiology - Transcatheter aortic valve implantation (TAVI) is a micro-invasive surgery used to treat patients with aortic stenosis (AS) efficiently. However, the...  相似文献   

19.
The analysis is based on a finite element procedure to extract the contact forces between an implanted Nitinol stent and the surrounding host tissue using postoperative CT images. The methodology was applied for patients (N=46) which have undergone a TAVI procedure with the Medtronic CoreValve Revalving System (MCRS) to obtain corresponding deformation and force maps. The postoperative CT data were recorded for each patient in both systolic and diastolic phase of the heart cycle. Scalar parameters were defined, which map deformed geometry and contact force field to mechanically relevant quantities: radial dilatation, radial shape distortion, non-convex points, mean force, a force deviation measure and a pressure equivalent. The latter demonstrates that in the area of the aortic root, the added circumferential loading is of the same order as the baseline average blood pressure, thus leading to a doubling of the local mechanical load. Generally the force distribution along the stent is non-homogeneous. A comparison of systolic and diastolic data revealed slightly higher contact forces during the diastole, indicating that the stent has to carry more load in this phase. The geometrical and mechanical parameters were compared for two types of clinical complication: para-valvular leakage (PVL) and permanent pacemaker requirement (PPM). It was found that an increase in mean force can be associated with both complications; significantly for PVL and as a trend for PPM.  相似文献   

20.
BackgroundAs coronavirus disease 2019 (COVID-19) has reached pandemic status, authors from the most severely affected countries have reported reduced rates of hospital admissions for patients with acute coronary syndrome (ACS).AimThe aim of the present study was to investigate the influence of the COVID-19 outbreak on hospital admissions and outcomes in ACS patients in a single high-volume centre in southeastern Europe.MethodsThis retrospective observational study aimed to investigate the number of hospital admissions for ACS, clinical findings at admission, length of hospitalisation, major complications and in-hospital mortality during the COVID-19 outbreak and to compare the data with the same parameters during an equivalent time frame in 2019. For the ST-elevated myocardial infarction (STEMI) subgroup of patients, changes in ischaemic times were analysed as well.ResultsThere was a significant reduction of 44.3% in the number of patients admitted for ACS during the COVID-19 outbreak when compared with the same period in 2019 (151 vs 271; 95% confidence interval 38.4–50.2, p < 0.01) with a higher mortality rate (13.2% vs 7.2%, p = 0.03). In 2020, patients with non-ST-elevated myocardial infarction presented more often with acute heart failure (3.3% vs 0.7%, p = 0.04). During the COVID-19 outbreak, we observed increases in the total ischaemic time (303 ± 163.4 vs 200.8 ± 156.8 min, p < 0.05) and door-to-balloon time (69.2 ± 58.4 vs 50.5 ± 31.3 min, p < 0.01) in STEMI patients.ConclusionsThese findings should increase the awareness of morbidity and mortality related to missed or delayed treatment of ACS among the public and the healthcare services.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号