首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Fluorescent monitoring of DNA amplification is the basis of real-time PCR, from which target DNA concentration can be determined from the fractional cycle at which a threshold amount of amplicon DNA is produced. Absolute quantification can be achieved using a standard curve constructed by amplifying known amounts of target DNA. In this study, the mathematics of quantitative PCR are examined in detail, from which several fundamental aspects of the threshold method and the application of standard curves are illustrated. The construction of five replicate standard curves for two pairs of nested primers was used to examine the reproducibility and degree of quantitative variation using SYBER® Green I fluorescence. Based upon this analysis the application of a single, well- constructed standard curve could provide an estimated precision of ±6–21%, depending on the number of cycles required to reach threshold. A simplified method for absolute quantification is also proposed, in which quantitative scale is determined by DNA mass at threshold.  相似文献   

2.
Polymerase chain reaction (PCR) is a sensitive and rapid method for the diagnosis of canine Leishmania infection and can be performed on a variety of biological samples, including peripheral blood, lymph node, bone marrow and skin. Standard PCR requires electrophoretic analysis of the amplification products and is usually not suitable for quantification of the template DNA (unless competitor-based or other methods are developed), being of reduced usefulness when accurate monitoring of target DNA is required. Quantitative real-time PCR allows the continuous monitoring of the accumulation of PCR products during the amplification reaction. This allows the identification of the cycle of near-logarithmic PCR product generation (threshold cycle) and, by inference, the relative quantification of the template DNA present at the start of the reaction. Since the amplification product are monitored in "real-time" as they form cycle-by-cycle, no post-amplification handling is required. The absolute quantification is performed according either to an internal standard co-amplified with the sample DNA, or to an external standard curve obtained by parallel amplification of serial known concentrations of a reference DNA sequence. From the quantification of the template DNA, an estimation of the relative load of parasites in the different samples can be obtained. The advantages compared to standard and semi-quantitative PCR techniques are reduction of the assay's time and contamination risks, and improved sensitivity. As for standard PCR, the minimal components of the quantitative PCR reaction mixture are the DNA target of the amplification, an oligonucleotide primer pair flanking the target sequence, a suitable DNA polymerase, deoxynucleotides, buffer and salts. Different technologies have been set up for the monitoring of amplification products, generally based on the use of fluorescent probes. For instance, SYBR Green technology is a non-specific detection system based on a fluorescent dsDNA intercalator and it is applicable to all potential targets. TaqMan technology is more specific since performs the direct assessment of the amount of amplified DNA using a fluorescent probe specific for the target sequence flanked by the primer pair. This probe is an oligonucleotide labelled with a reporter dye (fluorescent) and a quencher (which absorbs the fluorescent signal generated by the reporter). The thermic protocol of amplification allows the binding of the fluorescent probe to the target sequence before the binding of the primers and the starting of the polymerization by Taq polymerase. During polymerization, 5'-3' exonuclease activity of Taq polymerase digests the probe and in this way the reporter dye is released from the probe and a fluorescent signal is detected. The intensity of the signal accumulates at the end of each cycle and is related to the amount of the amplification product. In recent years, quantitative PCR methods based either on SYBR Green or TaqMan technology have been set up for the quantification of Leishmania in mouse liver, mouse skin and human peripheral blood, targeting either single-copy chromosomal or multi-copy minicircle sequences with high sensitivity and reproducibility. In particular, real-time PCR seems to be a reliable, rapid and noninvasive method for the diagnosis and follow up of visceral leishmaniasis in humans. At present, the application of real-time PCR for research and clinical diagnosis of Leishmania infection in dogs is still foreseable. As for standard PCR, the high sensitivity of real-time PCR could allow the use of blood sampling that is less invasive and easily performed for monitoring the status of the dogs. The development of a real-time PCR assay for Leishmania infantum infection in dogs could support the standard and optimized serological and PCR methods currenly in use for the diagnosis and follow-up of canine leishmaniasis, and perhaps prediction of recurrences associated with tissue loads of residual pathogens after treatment. At this regard, a TaqMan Real Time PCR method developed for the quantification of Leishmania infantum minicircle DNA in peripheral blood of naturally infected dogs sampled before and at different time points after the beginning of a standard antileishmanial therapy will be illustrated.  相似文献   

3.
PCR techniques have significantly improved the detection and identification of bacterial pathogens. Countless adaptations and applications have been described, including quantitative PCR and the latest innovation, real-time PCR. In real-time PCR, e.g., the 5′-nuclease chemistry renders the automated and direct detection and quantification of PCR products possible (P. M. Holland et al., Proc. Natl. Acad. Sci. USA 88:7276–7280, 1991). We present an assay for the quantitative detection of Listeria monocytogenes based on the 5′-nuclease PCR using a 113-bp amplicon from the listeriolysin O gene (hlyA) as the target. The assay was positive for all isolates of L. monocytogenes tested (65 isolates including the type strain) and negative for all other Listeria strains (16 isolates from five species tested) and several other bacteria (18 species tested). The application of 5′-nuclease PCR in diagnostics requires a quantitative sample preparation step. Several magnetic bead-based strategies were evaluated, since these systems are simple and relatively easy to automate. The combination of nonspecific binding of bacteria to paramagnetic beads, with subsequent DNA purification by use of the same beads, gave the most satisfactory result. The detection limit was approximately 6 to 60 CFU, quantification was linear over at least 7 log units, and the method could be completed within 3 h. In conclusion, a complete quantitative method for L. monocytogenes in water and in skimmed and raw milk was developed.  相似文献   

4.
Described in the article is a new approach for the sequence-specific detection of nucleic acids in real-time polymerase chain reaction (PCR) using fluorescently labeled oligonucleotide probes. The method is based on the production of PCR amplicons, which fold into dumbbell-like secondary structures carrying a specially designed ‘probe-luring’ sequence at their 5′ ends. Hybridization of this sequence to a complementary ‘anchoring’ tail introduced at the 3′ end of a fluorescent probe enables the probe to bind to its target during PCR, and the subsequent probe cleavage results in the florescence signal. As it has been shown in the study, this amplicon-endorsed and guided formation of the probe-target duplex allows the use of extremely short oligonucleotide probes, up to tetranucleotides in length. In particular, the short length of the fluorescent probes makes possible the development of a ‘universal’ probe inventory that is relatively small in size but represents all possible sequence variations. The unparalleled cost-effectiveness of the inventory approach is discussed. Despite the short length of the probes, this new method, named Angler real-time PCR, remains highly sequence specific, and the results of the study indicate that it can be effectively used for quantitative PCR and the detection of polymorphic variations.  相似文献   

5.
We describe the development of a sensitive high-performance liquid chromatographic (HPLC) method for polymerase chain reaction (PCR) products using bisbenzimide (Hoechst 33258 dye) based fluorimetric detection. The detection limit and specificity for double-strand DNA detection are improved in comparison with HPLC with UV absorbance detection. This HPLC, using a column packed with diethylaminoethyl-bonded non-porous resin particles, was applied to the detection of allele-specific PCR and restriction fragment length polymorphism analysis. We also developed a hybridization method analyzed by HPLC. DNA fragments (149 bp) containing the mutation site (C→A,G,T) in the N-ras gene were amplified by PCR. Fluorescein isothiocyanate (FITC)-labeled DNA probes were also prepared by PCR using FITC-labeled 5′ primer. Analysis of mutation was performed by the separation of a hybrid and non-reactive DNA probe with HPLC with fluorimetric detection after the hybridization of target DNA (149 bp) and a FITC DNA probe. The effects of various factors on hybridization were examined to establish optimal assay conditions. Under the conditions determined, a point mutation in PCR products obtained from the N-ras gene could be detected specifically by this method. The analysis of PCR products by HPLC may potentially be useful for DNA diagnosis.  相似文献   

6.
Succession of ecotypes, physiologically diverse strains with negligible rRNA sequence divergence, may explain the dominance of small, red-pigmented (phycoerythrin-rich) cyanobacteria in the autotrophic picoplankton of deep lakes (C. Postius and A. Ernst, Arch. Microbiol. 172:69–75, 1999). In order to test this hypothesis, it is necessary to determine the abundance of specific ecotypes or genotypes in a mixed background of phylogenetically similar organisms. In this study, we examined the performance of Taq nuclease assays (TNAs), PCR-based assays in which the amount of an amplicon is monitored by hydrolysis of a labeled oligonucleotide (TaqMan probe) when hybridized to the amplicon. High accuracy and a 7-order detection range made the real-time TNA superior to the corresponding end point technique. However, in samples containing mixtures of homologous target sequences, quantification can be biased due to limited specificity of PCR primers and probe oligonucleotides and due to accumulation of amplicons that are not detected by the TaqMan probe. A decrease in reaction efficiency, which can be recognized by direct monitoring of amplification, provides experimental evidence for the presence of such a problem and emphasizes the need for real-time technology in quantitative PCR. Use of specific primers and probes and control of amplification efficiency allow correct quantification of target DNA in the presence of an up to 104-fold excess of phylogenetically similar DNA and of an up to 107-fold excess of dissimilar DNA.  相似文献   

7.
A novel leaky surface acoustic wave (LSAW) bis-peptide nucleic acid (bis-PNA) biosensor with double two-port resonators has been constructed successfully for the quantitative detection of human papilloma virus (HPV). The bis-PNA probe can directly detect HPV genomic DNA without polymerase chain reaction (PCR) amplification, and it can bind to the target DNA sequences more effectively and specifically than a DNA probe. When the concentrations varied from 1 pg/L to 1000 μg/L, with 100 μg/L being the optimal, a typical linearity was found between the quantity of target and the phase shifts. The detection limit was 1.21 pg/L and the clinical specificity was 97.22% of that of real-time PCR. The bis-PNA probe was able to distinguish sequences that differ only in one base. Both the intraassay and interassay coefficients of variance (CVs) were <10%, and the biosensor can be regenerated for ten times without appreciable loss of activity. Therefore, this technical platform of LSAW biosensor can be applied to clinical samples for direct HPV detection.  相似文献   

8.
A novel signal generation principle suitable for real time and end-point detection of specific PCR products in a closed tube is described. Linear DNA probes were labeled at their 5′-ends with a stable, fluorescent terbium chelate. The fluorescence intensity of this chelate is lower when it is coupled to single-stranded DNA than when the chelate is free in solution. The synthesized probes were used in the real time monitoring of PCR using a prototype instrument that consisted of a fluorometer coupled to a thermal cycler. When the probe anneals to a complementary target amplicon, the 5′→3′ exonucleolytic activity of DNA polymerase detaches the label from the probe. This results in an enhanced terbium fluorescence signal. Since terbium has a long excited state lifetime, its fluorescence can be measured in a time-resolved manner, which results in a low background fluorescence and a 1000-fold signal amplification. The detection method is quantitative over an extremely wide linear range (at least 10–107 initial template molecules). The label strategy can easily be combined with existing label technologies, such as TaqMan 5′-exonuclease assays, in order to carry out multiplex assays that do not suffer from overlapping emission peaks of the fluorophores.  相似文献   

9.
To date real-time quantitative PCR and gene expression microarrays are the methods of choice for quantification of nucleic acids. Herein, we described a unique fluorescence resonance energy transfer-based microarray platform for real-time quantification of nucleic acid targets that combines advantages of both and reduces their limitations. A set of 3′ amino-modified TaqMan probes were designed and immobilized on a glass slide composing a regular microarray pattern, and used as probes in the consecutive PCR carried out on the surface. During the extension step of the PCR, 5′ nuclease activity of DNA polymerase will cleave quencher dyes of the immobilized probe in the presence of nucleic acids targets. The increase of fluorescence intensities generated by the change in physical distance between reporter fluorophore and quencher moiety of the probes were collected by a confocal scanner. Using this new approach we successfully monitored five different pathogenic genomic DNAs and analyzed the dynamic characteristics of fluorescence intensity changes on the TaqMan probe array. The results indicate that the TaqMan probe array on a planar glass slide monitors DNA targets with excellent specificity as well as high sensitivity. This set-up offers the great advantage of real-time quantitative detection of DNA targets in a parallel array format.  相似文献   

10.
Use of quantitative real-time PCR (QPCR) with TaqMan probes is increasingly popular in various environmental works to detect and quantify a specific microorganism or a group of target microorganism. Although many aspects of conducting a QPCR assay have become very easy to perform, a proper design of oligonucleotide sequences comprising primers and a probe is still considered as one of the most important aspects of a QPCR application. This work was conducted to design group specific primer and probe sets for the detection of ammonia oxidizing bacteria (AOB) using a real-time PCR with a TaqMan system. The genera Nitrosomonas and Nitrosospira were grouped into five clusters based on similarity of their 16S rRNA gene sequences. Five group-specific AOB primer and probe sets were designed. These sets separately detect four subgroups of Nitrosomonas (Nitrosomonas europaea-, Nitrosococcus mobilis-, Nitrosomonas nitrosa-, and Nitrosomonas cryotolerans-clusters) along with the genus Nitrosospira. Target-group specificity of each primer and probe set was initially investigated by analyzing potential false results in silico, followed by a series of experimental tests for QPCR efficiency and detection limit. In general, each primer and probe set was very specific to the target group and sensitive to detect target DNA as low as two 16S rRNA gene copies per reaction mixture. QPCR efficiency, higher than 93.5%, could be achieved for all primer and probe sets. The primer and probe sets designed in this study can be used to detect and quantify the beta-proteobacterial AOB in biological nitrification processes and various environments.  相似文献   

11.
We describe a fluorescence-based directed termination PCR (fluorescent DT–PCR) that allows accurate determination of actual sequence changes without dideoxy DNA sequencing. This is achieved using near infrared dye-labeled primers and performing two PCR reactions under low and unbalanced dNTP concentrations. Visualization of resulting termination fragments is accomplished with a dual dye Li-cor DNA sequencer. As each DT–PCR reaction generates two sets of terminating fragments, a pair of complementary reactions with limiting dATP and dCTP collectively provide information on the entire sequence of a target DNA, allowing an accurate determination of any base change. Blind analysis of 78 mutants of the supF reporter gene using fluorescent DT–PCR not only correctly determined the nature and position of all types of substitution mutations in the supF gene, but also allowed rapid scanning of the signature sequences among identical mutations. The method provides simplicity in the generation of terminating fragments and 100% accuracy in mutation characterization. Fluorescent DT–PCR was successfully used to generate a UV-induced spectrum of mutations in the supF gene following replication on a single plate of human DNA repair-deficient cells. We anticipate that the automated DT–PCR method will serve as a cost-effective alternative to dideoxy sequencing in studies involving large-scale analysis for nucleotide sequence changes.  相似文献   

12.
For quantitative PCR assay of Salmonella enterica serovar Typhimurium in food samples, a real-time PCR method was developed, based on DNA genome equivalent. Specific primers and probe designed based on the STM4497 gene of S. Typhimurium LT2 showed the specificity to S. Typhimurium. Threshold cycle (Ct) values of real-time PCR were obtained from a quantitative standard curve with genomic DNA of Salmonella Typhimurium. In addition, the recovery of S. Typhimurium inoculated artificially to chicken samples with 4.5x105 to 4.5x100 CFU/ml was evaluated by using real-time PCR and plate-count methods. Result showed that the number of cells calculated from the real-time PCR method had good correlation with that of the plate-count method. This real-time PCR method could be applicable to the detection and quantification of S. Typhimurium in food samples.  相似文献   

13.
14.
Schlosser K  Gu J  Lam JC  Li Y 《Nucleic acids research》2008,36(14):4768-4777
Herein, we sought new or improved endoribonucleases based on catalytic DNA molecules known as deoxyribozymes. The current repertoire of RNA-cleaving deoxyribozymes can cleave nearly all of the 16 possible dinucleotide junctions with rates of at least 0.1/min, with the exception of pyrimidine–pyrimidine (pyr–pyr) junctions, which are cleaved 1–3 orders of magnitude slower. We conducted four separate in vitro selection experiments to target each pyr–pyr dinucleotide combination (i.e. CC, UC, CT and UT) within a chimeric RNA/DNA substrate. We used a library of DNA molecules containing only 20 random-sequence nucleotides, so that all possible sequence permutations could be sampled in each experiment. From a total of 245 clones, we identified 22 different sequence families, of which 21 represented novel deoxyribozyme motifs. The fastest deoxyribozymes exhibited kobs values (single-turnover, intermolecular format) of 0.12/min, 0.04/min, 0.13/min and 0.15/min against CC, UC, CT and UT junctions, respectively. These values represent a 6- to 8-fold improvement for CC and UC junctions, and a 1000- to 1600-fold improvement for CT and UT junctions, compared to the best rates reported previously under identical reaction conditions. The same deoxyribozymes exhibited ~1000-fold lower activity against all RNA substrates, but could potentially be improved through further in vitro evolution and engineering.  相似文献   

15.
Quencher extension (QEXT) is a novel single step closed tube real-time method to quantify SNPs using reporters and quenchers in combination with primer extension. A probe with a 5′-reporter dye is single base extended with a dideoxy nucleotide containing a quencher dye if the target SNP allele is present. The extension is recorded from the quenching (reduced fluorescence) of the reporter dye. This avoids the influence of the unincorporated dye-labeled nucleotides, resulting in high accuracy and a high signal-to-noise ratio. The relative amount of a specific SNP allele is determined from the nucleotide incorporation rate in a thermo-cycling reaction. We tested the QEXT assay using five SNPs in the Listeria monocytogenes inlA gene as a model system. The presence of the target SNP alleles was determined with high statistical confidence (P < 0.0005). The quantitative detection limits were between 0 and 5% for the targeted SNP alleles on a background of other SNP alleles (P < 0.05). The QEXT method is directly adaptable to current real-time PCR equipment and is thus suited for high throughput and a wide application range.  相似文献   

16.
This study evaluated the applicability of droplet digital PCR (ddPCR) as a tool for maize zygosity determination using quantitative real-time PCR (qPCR) as a reference technology. Quantitative real-time PCR is commonly used to determine transgene copy number or GMO zygosity characterization. However, its effectiveness is based on identical reaction efficiencies for the transgene and the endogenous reference gene. Additionally, a calibrator sample should be utilized for accuracy. Droplet digital PCR is a DNA molecule counting technique that directly counts the absolute number of target and reference DNA molecules in a sample, independent of assay efficiency or external calibrators. The zygosity of the transgene can be easily determined using the ratio of the quantity of the target gene to the reference single copy endogenous gene. In this study, both the qPCR and ddPCR methods were used to determine insect-resistant transgenic maize IE034 zygosity. Both methods performed well, but the ddPCR method was more convenient because of its absolute quantification property.  相似文献   

17.
Duplex Scorpion primers in SNP analysis and FRET applications   总被引:12,自引:1,他引:11       下载免费PDF全文
Scorpions are fluorogenic PCR primers with a probe element attached at the 5′-end via a PCR stopper. They are used in real-time amplicon-specific detection of PCR products in homogeneous solution. Two different formats are possible, the ‘stem–loop’ format and the ‘duplex’ format. In both cases the probing mechanism is intramolecular. We have shown that duplex Scorpions are efficient probes in real-time PCR. They give a greater fluorescent signal than stem–loop Scorpions due to the vastly increased separation between fluorophore and quencher in the active form. We have demonstrated their use in allelic discrimination at the W1282X locus of the ABCC7 gene and shown that they can be used in assays where fluorescence resonance energy transfer is required.  相似文献   

18.
Identification of hepatotoxin-producing cyanobacteria by DNA-chip   总被引:1,自引:0,他引:1  
We developed a new tool to detect and identify hepatotoxin-producing cyanobacteria of the genera Anabaena , Microcystis , Planktothrix , Nostoc and Nodularia . Genus-specific probe pairs were designed for the detection of the microcystin ( mcyE ) and nodularin synthetase genes ( ndaF ) of these five genera to be used with a DNA-chip. The method couples a ligation detection reaction, in which the polymerase chain reaction (PCR)-amplified mcyE / ndaF genes are recognized by the probe pairs, with a hybridization on a universal microarray. All the probe pairs specifically detected the corresponding mcyE / ndaF gene sequences when DNA from the microcystin- or nodularin-producing cyanobacterial strains were used as template in the PCR. Furthermore, the strict specificity of detection enabled identification of the potential hepatotoxin producers. Detection of the genes was very sensitive; only 1–5 fmol of the PCR product were needed to produce signal intensities that exceeded the set background threshold level. The genus-specific probe pairs also reliably detected potential microcystin producers in DNA extracted from six lake and four brackish water samples. In lake samples, the same microcystin producers were identified with quantitative real-time PCR analysis. The specificity, sensitivity and ability of the DNA-chip in simultaneously detecting all the main hepatotoxin producers make this method suitable for high-throughput analysis and monitoring of environmental samples.  相似文献   

19.
The synthesis and characterization of isotopomer tandem nucleic acid mass tag–peptide nucleic acid (TNT–PNA) conjugates is described along with their use as electrospray ionisation-cleavable (ESI-Cleavable) hybridization probes for the detection and quantification of target DNA sequences by electrospray ionisation tandem mass spectrometry (ESI-MS/MS). ESI-cleavable peptide TNT isotopomers were introduced into PNA oligonucleotide sequences in a total synthesis approach. These conjugates were evaluated as hybridization probes for the detection and quantification of immobilized synthetic target DNAs using ESI-MS/MS. In these experiments, the PNA portion of the conjugate acts as a hybridization probe, whereas the peptide TNT is released in a collision-based process during the ionization of the probe conjugate in the electrospray ion source. The cleaved TNT acts as a uniquely resolvable marker to identify and quantify a unique target DNA sequence. The method should be applicable to a wide variety of assays requiring highly multiplexed, quantitative DNA/RNA analysis, including gene expression monitoring, genetic profiling and the detection of pathogens.  相似文献   

20.
We describe a new method for relative quantification of 40 different DNA sequences in an easy to perform reaction requiring only 20 ng of human DNA. Applications shown of this multiplex ligation-dependent probe amplification (MLPA) technique include the detection of exon deletions and duplications in the human BRCA1, MSH2 and MLH1 genes, detection of trisomies such as Down’s syndrome, characterisation of chromosomal aberrations in cell lines and tumour samples and SNP/mutation detection. Relative quantification of mRNAs by MLPA will be described elsewhere. In MLPA, not sample nucleic acids but probes added to the samples are amplified and quantified. Amplification of probes by PCR depends on the presence of probe target sequences in the sample. Each probe consists of two oligonucleotides, one synthetic and one M13 derived, that hybridise to adjacent sites of the target sequence. Such hybridised probe oligonucleotides are ligated, permitting subsequent amplification. All ligated probes have identical end sequences, permitting simultaneous PCR amplification using only one primer pair. Each probe gives rise to an amplification product of unique size between 130 and 480 bp. Probe target sequences are small (50–70 nt). The prerequisite of a ligation reaction provides the opportunity to discriminate single nucleotide differences.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号