首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Qi  Yong  Shang  Jun-yi  Ma  Li-jun  Sun  Bei-bei  Hu  Xin-gang  Liu  Bao  Zhang  Guo-jun 《Respiratory research》2014,15(1):1-9

Background

Analysis of exhaled breath condensates (EBC) is a non-invasive technique to evaluate biomarkers such as antioxidants in the pediatric population, but limited data exists of its use in intubated patients, particularly newborns. Currently, tracheal aspirate (TA) serves as the gold standard collection modality in critically ill newborns, but this method remains invasive. We tested the hypothesis that glutathione status would positively correlate between EBC and TA collections in intubated newborns in the Newborn Intensive Care Unit (NICU). We also hypothesized that these measurements would be associated with alveolar macrophage (AM) glutathione status in the newborn lung.

Methods

Reduced glutathione (rGSH), glutathione disulfide (GSSG), and total GSH (rGSH + (2 X GSSG)) were measured in sequential EBC and TA samples from 26 intubated newborns via high performance liquid chromatography (HPLC). Additionally, AM glutathione was evaluated via immunofluorescence. Pearson’s correlation coefficient and associated 95% confidence intervals were used to quantify the associations between raw and urea-corrected concentrations in EBC and TA samples and AM staining. Statistical significance was defined as p ≤ 0.05 using two-tailed tests. The sample size was projected to allow for a correlation coefficient of 0.5, with 0.8 power and alpha of 0.05.

Results

EBC was obtainable from intubated newborns without adverse clinical events. EBC samples demonstrated moderate to strong positive correlations with TA samples in terms of rGSH, GSSG and total GSH. Positive correlations between the two sampling sites were observed in both raw and urea-corrected concentrations of rGSH, GSSG and total GSH. AM glutathione staining moderately correlated with GSSG and total GSH status in both the TA and EBC.

Conclusions

GSH status in EBC samples of intubated newborns significantly correlated with the GSH status of the TA sample and was reflective of cellular GSH status in this cohort of neonatal patients. Non-invasive EBC sampling of intubated newborns holds promise for monitoring antioxidant status such as GSH in the premature lung. Further studies are necessary to evaluate the potential relationships between EBC biomarkers in the intubated premature newborn and respiratory morbidities.  相似文献   

2.
The exhaled breath condensate (EBC) method represents a new, noninvasive way to detect inflammatory and metabolic markers in the fluid that covers the airways [epithelial lining fluid (ELF)]. However, respiratory droplets represent only a very small and variable fraction of the EBC, most (approximately 99.99%) of which is water vapor. Our objective was to show that ELF concentrations could be calculated from EBC values by using any of three dilutional indicators (urea, total cations, and conductivity) in nine normal and nine chronic obstructive lung disease (COPD) subjects. EBC concentrations of Na(+), K(+), Ca(2+), Mg(2+), total cations, urea, and conductivity varied over a 10-fold range among individuals, but concentrations of these constituents (except Ca(2+)) remained well correlated (r(2) = 0.44-0.83, P < 0.001). Dilution (D) of respiratory droplets in water vapor was calculated by dividing plasma concentrations of the dilutional indicators by EBC concentrations. Estimates of D were not significantly different among these indicators, and urea D averaged 10,800 +/- 2,100 (SE) in normal and 12,600 +/- 3,300 in COPD subjects. Although calculated Na(+) concentrations in the ELF were less than one-half those in plasma, and concentrations of K(+), Ca(2+), and Mg(2+) exceeded those in plasma, total cation concentrations in ELF were not significantly different from those in plasma, indicating that ELF is isotonic in both normal and COPD subjects. EBC amylase concentrations (measured with an ultrasensitive procedure) indicated that saliva represented <10% of the respiratory (ELF) droplets in all but three samples. Dilutional and salivary markers are essential for interpretation of EBC studies.  相似文献   

3.
Endotoxin, a component of the cell walls of gram-negative bacteria, is a contaminant in organic dusts (house dust) and aerosols. In humans, small amounts of endotoxin may cause a local inflammatory response. Exhaled nitric oxide (eNO) levels, an inflammation indicator, are associated with the pH values of exhaled breath condensate (EBC). This study evaluated seasonal changes on indoor endotoxin concentrations in homes and the relationships between endotoxin exposure and eNO/EBC pH levels for healthy children and children with allergy-related respiratory diseases. In total, 34 children with allergy-related respiratory diseases and 24 healthy children were enrolled. Indoor air quality measurements and dust sample analysis for endotoxin were conducted once each season inside 58 surveyed homes. The eNO, EBC pH levels, and pulmonary function of the children were also determined. The highest endotoxin concentrations were on kitchen floors of homes of children with allergy-related respiratory diseases and healthy children, and on bedroom floors of homes of asthmatic children and healthy children. Seasonal changes existed in endotoxin concentrations in dust samples from homes of children with allergic rhinitis, with or without asthma, and in EBC pH values among healthy children and those with allergy-related respiratory diseases. Strong relationships existed between endotoxin exposure and EBC pH values in children with allergic rhinitis.  相似文献   

4.

Background

Endothelin-1 (ET-1) and Nitric Oxide (NO) are crucial mediators for establishing pulmonary artery hypertension (PAH). We tested the hypothesis that their imbalance might also occur in COPD patients with PAH.

Methods

The aims of the study were to measure exhaled breath condensate (EBC) and circulating levels of ET-1, as well as exhaled NO (FENO) levels by, respectively, a specific enzyme immunoassay kit, and by chemiluminescence analysis in 3 groups of subjects: COPD with PAH (12), COPD only (36), and healthy individuals (15). In order to evaluate pulmonary-artery systolic pressure (PaPs), all COPD patients underwent Echo-Doppler assessment.

Results

Significantly increased exhaled and circulating levels of ET-1 were found in COPD with PAH compared to both COPD (p < 0.0001) only, and healthy controls (p < 0.0001). In COPD with PAH, linear regression analysis showed good correlation between ET-1 in EBC and PaPs (r = 0.621; p = 0.031), and between arterial levels of ET-1 and PaPs (r = 0.648; p = 0.022), while arterial levels of ET-1 inversely correlated with FEV1%, (r = -0.59, p = 0.043), and PaPs negatively correlated to PaO2 (r = -0.618; p = 0.032). Significantly reduced levels of FENO were found in COPD associated with PAH, compared to COPD only (22.92 ± 11.38 vs.35.07 ± 17.53 ppb; p = 0.03). Thus, we observed an imbalanced output in the breath between ET-1 and NO, as expression of pulmonary endothelium and epithelium impairment, in COPD with PAH compared to COPD only. Whether this imbalance is an early cause or result of PAH due to COPD is still unknown and deserves further investigations.  相似文献   

5.
As a noninvasive method, exhaled breath condensate (EBC) has gained importance to improve monitoring of lung diseases and to detect biomarkers. The aim of the study was to investigate, whether erythropoietin (EPO) is detectable in EBC. EBC was collected from 22 consecutive patients as well as from healthy individuals. Using a multiplex fluorescent bead immunoassay, we detected EPO in EBC, as well as tumour necrosis factor-alpha (TNF-alpha) in 13 out of 22 patients simultaneously (EPO 0.21 +/- 0.03 in U/mL and TNF-alpha 34.6 +/- 4.2 in pg/mL, mean +/- SEM). No significant differences for EPO levels or correlation between EPO and TNF-alpha were found but TNF-alpha was significantly higher in patients with chronic obstructive pulmonary disease (COPD) than in non-COPD (obstructive sleep apnoea, OSA, and lung healthy patients). This is the first report of detection of EPO in EBC. Due to the small study size more data is needed to clarify the role of EPO in EBC.  相似文献   

6.
《Biomarkers》2013,18(6):481-487
Abstract

Rhinitis and asthma are the most common respiratory diseases in children. We assessed whether airway inflammation markers were associated with nasal allergies and self-reported symptoms of wheeze and rhinitis in 130 children 6–12 year old in an epidemiological context. Independent of sex and age, the fraction of exhaled nitric oxide (FeNO) and nasal mast cell (MC) activation (tryptase ≥?5?ng/mL) were positively associated with wheeze, rhinitis and with nasal allergy. Nasal eosinophil cationic protein (ECP) and exhaled breath condensate (EBC) markers (pH, 8-isoprostane, interleukin-1β) were not associated with symptoms or with nasal allergy. In conclusion, FeNO and nasal tryptase reflect allergic inflammation in the respiratory system.  相似文献   

7.
Oxidative stress is the hallmark of various chronic inflammatory lung diseases. Increased concentrations of reactive oxygen species (ROS) in the lungs of such patients are reflected by elevated concentrations of oxidative stress markers in the breath, airways, lung tissue and blood. Traditionally, the measurement of these biomarkers has involved invasive procedures to procure the samples or to examine the affected compartments, to the patient's discomfort. As a consequence, there is a need for less or non-invasive approaches to measure oxidative stress. The collection of exhaled breath condensate (EBC) has recently emerged as a non-invasive sampling method for real-time analysis and evaluation of oxidative stress biomarkers in the lower respiratory tract airways. The biomarkers of oxidative stress such as H2O2, F2-isoprostanes, malondialdehyde, 4-hydroxy-2-nonenal, antioxidants, glutathione and nitrosative stress such as nitrate/nitrite and nitrosated species have been successfully measured in EBC. The reproducibility, sensitivity and specificity of the methodologies used in the measurements of EBC oxidative stress biomarkers are discussed. Oxidative stress biomarkers also have been measured for various antioxidants in disease prognosis. EBC is currently used as a research and diagnostic tool in free radical research, yielding information on redox disturbance and the degree and type of inflammation in the lung. It is expected that EBC can be exploited to detect specific levels of biomarkers and monitor disease severity in response to appropriate prescribed therapy/treatment.  相似文献   

8.

Background

Asthma is a chronic inflammatory disease of the airways but recent studies have shown that alveoli are also subject to pathophysiological changes. This study was undertaken to compare hydrogen peroxide (H2O2) concentrations in different parts of the lung using a new technique of fractioned breath condensate sampling.

Methods

In 52 children (9-17 years, 32 asthmatic patients, 20 controls) measurements of exhaled nitric oxide (FENO), lung function, H2O2 in exhaled breath condensate (EBC) and the asthma control test (ACT) were performed. Exhaled breath condensate was collected in two different fractions, representing mainly either the airways or the alveoli. H2O2 was analysed in the airway and alveolar fractions and compared to clinical parameters.

Results

The exhaled H2O2 concentration was significantly higher in the airway fraction than in the alveolar fraction comparing each single pair (p = 0.003, 0.032 and 0.040 for the whole study group, the asthmatic group and the control group, respectively). Asthma control, measured by the asthma control test (ACT), correlated significantly with the H2O2 concentrations in the alveolar fraction (r = 0.606, p = 0.004) but not with those in the airway fraction in the group of children above 12 years. FENO values and lung function parameters did not correlate to the H2O2 concentrations of each fraction.

Conclusion

The new technique of fractionated H2O2 measurement may differentiate H2O2 concentrations in different parts of the lung in asthmatic and control children. H2O2 concentrations of the alveolar fraction may be related to the asthma control test in children.  相似文献   

9.
Abstract

Oxidative stress is the hallmark of various chronic inflammatory lung diseases. Increased concentrations of reactive oxygen species (ROS) in the lungs of such patients are reflected by elevated concentrations of oxidative stress markers in the breath, airways, lung tissue and blood. Traditionally, the measurement of these biomarkers has involved invasive procedures to procure the samples or to examine the affected compartments, to the patient's discomfort. As a consequence, there is a need for less or non-invasive approaches to measure oxidative stress. The collection of exhaled breath condensate (EBC) has recently emerged as a non-invasive sampling method for real-time analysis and evaluation of oxidative stress biomarkers in the lower respiratory tract airways. The biomarkers of oxidative stress such as H2O2, F2-isoprostanes, malondialdehyde, 4-hydroxy-2-nonenal, antioxidants, glutathione and nitrosative stress such as nitrate/nitrite and nitrosated species have been successfully measured in EBC. The reproducibility, sensitivity and specificity of the methodologies used in the measurements of EBC oxidative stress biomarkers are discussed. Oxidative stress biomarkers also have been measured for various antioxidants in disease prognosis. EBC is currently used as a research and diagnostic tool in free radical research, yielding information on redox disturbance and the degree and type of inflammation in the lung. It is expected that EBC can be exploited to detect specific levels of biomarkers and monitor disease severity in response to appropriate prescribed therapy/treatment.  相似文献   

10.
Biomarkers of some pulmonary diseases in exhaled breath   总被引:16,自引:0,他引:16  
Analysis of various biomarkers in exhaled breath allows completely non-invasive monitoring of inflammation and oxidative stress in the respiratory tract in inflammatory lung diseases, including asthma, chronic obstructive pulmonary disease (COPD), cystic fibrosis (CF), bronchiectasis and interstitial lung diseases. The technique is simple to perform, may be repeated frequently, and can be applied to children, including neonates, and patients with severe disease in whom more invasive procedures are not possible. Several volatile chemicals can be measured in the breath (nitric oxide, carbon monoxide, ammonia), and many non-volatile molecules (mediators, oxidation and nitration products, proteins) may be measured in exhaled breath condensate. Exhaled breath analysis may be used to quantify inflammation and oxidative stress in the respiratory tract, in differential diagnosis of airway disease and in the monitoring of therapy. Most progress has been made with exhaled nitric oxide (NO), which is increased in atopic asthma, is correlated with other inflammatory indices and is reduced by treatment with corticosteroids and antileukotrienes, but not (β2-agonists. In contrast, exhaled NO is normal in COPD, reduced in CF and diagnostically low in primary ciliary dyskinesia. Exhaled carbon monoxide (CO) is increased in asthma, COPD and CF. Increased concentrations of 8-isoprostane, hydrogen peroxide, nitrite and 3-nitrotyrosine are found in exhaled breath condensate in inflammatory lung diseases. Furthermore, increased levels of lipid mediators are found in these diseases, with a differential pattern depending on the nature of the disease process. In the future it is likely that smaller and more sensitive analysers will extend the discriminatory value of exhaled breath analysis and that these techniques may be available to diagnose and monitor respiratory diseases in the general practice and home setting.  相似文献   

11.
Biomarkers in exhaled breath are useful for respiratory disease diagnosis in human volunteers. Conventional methods that collect non-volatile biomarkers, however, necessitate an extensive dilution and sanitation processes that lowers collection efficiencies and convenience of use. Electret filter emerged in recent decade to collect virus biomarkers in exhaled breath given its simplicity and effectiveness. To investigate the capability of electret filters to collect protein biomarkers, a model that consists of an atomizer that produces protein aerosol and an electret filter that collects albumin and carcinoembryonic antigen-a typical biomarker in lung cancer development- from the atomizer is developed. A device using electret filter as the collecting medium is designed to collect human albumin from exhaled breath of 6 volunteers. Comparison of the collecting ability between the electret filter method and other 2 reported methods is finally performed based on the amounts of albumin collected from human exhaled breath. In conclusion, a decreasing collection efficiency ranging from 17.6% to 2.3% for atomized albumin aerosol and 42% to 12.5% for atomized carcinoembryonic antigen particles is found; moreover, an optimum volume of sampling human exhaled breath ranging from 100 L to 200 L is also observed; finally, the self-designed collecting device shows a significantly better performance in collecting albumin from human exhaled breath than the exhaled breath condensate method (p<0.05) but is not significantly more effective than reported 3-stage impactor method (p>0.05). In summary, electret filters are potential in collecting non-volatile biomarkers in human exhaled breath not only because it was simpler, cheaper and easier to use than traditional methods but also for its better collecting performance.  相似文献   

12.
Flashover phenomenon occurs when surfaces exposed to thermal radiation reach the ignition temperature, and the fire rapidly spreads in enclosed area. Flashover training (FOT) performed by firefighters is a simulation of flashover phenomenon under controlled conditions. The study aimed to test thermal and physical strain in male firefighters and instructors attending FOT and its influence on DNA damage, exhaled breath condensate (EBC) pH, and fraction of exhaled nitric oxide (FeNO). DNA damage markers were analyzed in 51 attendees and 7 instructors, and EBC pH and FeNO in 40 respiratory healthy non-smoking subjects (34 attendees and 6 instructors).The average body temperature and pulse increase was 1.1 °C and 30 beats per minute, respectively. A prominent increase in the alkali-labile sites' level has been observed in instructors' peripheral leukocytes compared to first-time attendees (tail length p=0.050, % of DNA in tail p=0.005). FOT was related only to physiological FVC and FEV1 increase (by 4% and 2.7% on average), and FeNO dropped after the exercise by 2 ppb in comparison with basal values (P=0.034). EBC pH did not change during FOT, but FeNO was inversely correlated to EBC pH after the exercise (Spearman's rho=−0.66, P=0.013). With respect to the thermal and physical strain, FOT is considered to be a safe training procedure for healthy firefighters. The increase rate in primary DNA damage found in the instructors' peripheral leukocytes requires further examination in a larger sample size.  相似文献   

13.
BackgroundCystic Fibrosis (CF) is characterized by chronically inflamed airways, and inflammation even increases during pulmonary exacerbations. These adverse events have an important influence on the well-being, quality of life, and lung function of patients with CF. Prediction of exacerbations by inflammatory markers in exhaled breath condensate (EBC) combined with early treatment may prevent these pulmonary exacerbations and may improve the prognosis.AimTo investigate the diagnostic accuracy of a set of inflammatory markers in EBC to predict pulmonary exacerbations in children with CF.MethodsIn this one-year prospective observational study, 49 children with CF were included. During study visits with an interval of 2 months, a symptom questionnaire was completed, EBC was collected, and lung function measurements were performed. The acidity of EBC was measured directly after collection. Inflammatory markers interleukin (IL)-6, IL-8, tumor necrosis factor α (TNF-α), and macrophage migration inhibitory factor (MIF) were measured using high sensitivity bead based flow immunoassays. Pulmonary exacerbations were recorded during the study and were defined in two ways. The predictive power of inflammatory markers and the other covariates was assessed using conditionally specified models and a receiver operating characteristic curve (SAS version 9.2). In addition, k-nearest neighbors (KNN) algorithm was applied (SAS version 9.2).ResultsSixty-five percent of the children had one or more exacerbations during the study. The conditionally specified models showed an overall correct prediction rate of 55%. The area under the curve (AUC) was equal to 0.62. The results obtained with the KNN algorithm were very similar.ConclusionAlthough there is some evidence indicating that the predictors outperform random guessing, the general diagnostic accuracy of EBC acidity and the EBC inflammatory markers IL-6, IL-8, TNF-α and MIF is low. At present it is not possible to predict pulmonary exacerbations in children with CF with the chosen biomarkers and the method of EBC analysis. The biochemical measurements of EBC markers should be improved and other techniques should be considered.  相似文献   

14.
This veterinary study is aimed at further standardization of H2O2 and pH measurements in exhaled breath condensate (EBC). Data obtained in the study provide valuable information for many mammalian species including humans, and may help to avoid general pitfalls in interpretation of EBC data. EBC was sampled via the 'ECoScreen' in healthy calves (body weight 63-98 kg). Serum samples and condensates of ambient (indoor) air were collected in parallel. In the study on H2O2, concentrations of H2O2 in EBC, blood and ambient air were determined with the biosensor system 'ECoCheck'. In EBC, the concentration of H2O2 was found to be dependent on food intake and increased significantly in the course of the day. Physiologically, lowest H2O2 concentrations at 06:00 varied within the range 138-624 nmol l-1 EBC or 0.10-0.94 nmol per 100 l exhaled breath and individual concentrations were significantly different indicating a remarkable intersubject variability. Highly reproducible results were seen within each subject (three different days within 4 weeks). No correlation existed between H2O2 concentrations in EBC and blood, and EBC-H2O2 was not influenced by variables of spontaneous breathing. Further results confirmed that standardization of H2O2 measurements in EBC requires (1) the re-calculation of the concentration exhaled per 100 l exhaled breath (because the analyzed concentration in the liquid condensate underlies multiple methodological sources of variability given by the collection process), and (2) subtracting the concentration of inspired indoor H2O2. In the study on pH use of the ISFET electrode (Sentron, the Netherlands) and a blood gas analyzer ABL 550 (Radiometer, Denmark) led to comparable results for EBC-pH (r=0.89, R2=79.3%, p≤0.001). Physiological pH data in non-degassed EBC samples varied between 5.3 and 6.5, and were not significantly different between subjects, but were significantly higher in the evening compared with the morning. EBC-pH was not dependent on variables of spontaneous breathing pattern or ambient conditions, and no significant correlation was found between serum and EBC for pH.  相似文献   

15.
Abstract

This veterinary study is aimed at further standardization of H2O2 and pH measurements in exhaled breath condensate (EBC). Data obtained in the study provide valuable information for many mammalian species including humans, and may help to avoid general pitfalls in interpretation of EBC data. EBC was sampled via the ‘ECoScreen’ in healthy calves (body weight 63–98 kg). Serum samples and condensates of ambient (indoor) air were collected in parallel. In the study on H2O2, concentrations of H2O2 in EBC, blood and ambient air were determined with the biosensor system ‘ECoCheck’. In EBC, the concentration of H2O2 was found to be dependent on food intake and increased significantly in the course of the day. Physiologically, lowest H2O2 concentrations at 06:00 varied within the range 138–624 nmol l?1 EBC or 0.10–0.94 nmol per 100 l exhaled breath and individual concentrations were significantly different indicating a remarkable intersubject variability. Highly reproducible results were seen within each subject (three different days within 4 weeks). No correlation existed between H2O2 concentrations in EBC and blood, and EBC–H2O2 was not influenced by variables of spontaneous breathing. Further results confirmed that standardization of H2O2 measurements in EBC requires (1) the re-calculation of the concentration exhaled per 100 l exhaled breath (because the analyzed concentration in the liquid condensate underlies multiple methodological sources of variability given by the collection process), and (2) subtracting the concentration of inspired indoor H2O2. In the study on pH use of the ISFET electrode (Sentron, the Netherlands) and a blood gas analyzer ABL 550 (Radiometer, Denmark) led to comparable results for EBC–pH (r=0.89, R2=79.3%, p≤0.001). Physiological pH data in non-degassed EBC samples varied between 5.3 and 6.5, and were not significantly different between subjects, but were significantly higher in the evening compared with the morning. EBC–pH was not dependent on variables of spontaneous breathing pattern or ambient conditions, and no significant correlation was found between serum and EBC for pH.  相似文献   

16.
Rahman I  Kelly F 《Free radical research》2003,37(12):1253-1266
Oxidative stress is associated with a range of inflammatory lung diseases including asthma, adult respiratory distress syndrome, idiopathic pulmonary fibrosis, pneumonia, lung transplantation, chronic obstructive pulmonary disease, cystic fibrosis, bronchiectasis and lung cancer. Increased concentrations of reactive oxygen species (ROS) in the airways of such patients are reflected by elevated concentrations of oxidative stress markers in the breath, airways, lung tissue and blood. Traditionally, the measurement of these biomarkers has involved invasive procedures to procure the samples, or examine the compartments. As a consequence, there is a need for less invasive approaches to measure oxidative stress. Analysis of breath hydrocarbons has partly fulfilled this need, however only gas phase volatile constituents can be assessed by this approach. The collection of exhaled breath condensate (EBC) is a simple, non-invasive approach, which comprehensively samples the lower respiratory tract. It is currently used as a research and diagnostic tool in the free radical field, yielding information on redox disturbance and the degree and type of inflammation in the lung. With further technical developments, such an approach may ultimately have a role in the clinic, in helping to diagnose specific lung diseases. EBC can be exploited to assess a spectrum of potential biomarkers, thus generating a “finger print” characteristic of the disease. By assessing the nature of oxidative stress in this manner, the most appropriate therapy can be selected and the response to treatment monitored.  相似文献   

17.
Oxidative stress is associated with a range of inflammatory lung diseases including asthma, adult respiratory distress syndrome, idiopathic pulmonary fibrosis, pneumonia, lung transplantation, chronic obstructive pulmonary disease, cystic fibrosis, bronchiectasis and lung cancer. Increased concentrations of reactive oxygen species (ROS) in the airways of such patients are reflected by elevated concentrations of oxidative stress markers in the breath, airways, lung tissue and blood. Traditionally, the measurement of these biomarkers has involved invasive procedures to procure the samples, or examine the compartments. As a consequence, there is a need for less invasive approaches to measure oxidative stress. Analysis of breath hydrocarbons has partly fulfilled this need, however only gas phase volatile constituents can be assessed by this approach. The collection of exhaled breath condensate (EBC) is a simple, non-invasive approach, which comprehensively samples the lower respiratory tract. It is currently used as a research and diagnostic tool in the free radical field, yielding information on redox disturbance and the degree and type of inflammation in the lung. With further technical developments, such an approach may ultimately have a role in the clinic, in helping to diagnose specific lung diseases. EBC can be exploited to assess a spectrum of potential biomarkers, thus generating a “finger print” characteristic of the disease. By assessing the nature of oxidative stress in this manner, the most appropriate therapy can be selected and the response to treatment monitored.  相似文献   

18.
Exercise-caused metabolic changes can be followed by monitoring exhaled volatiles; however it has not been previously reported if a spectrum of exhaled gases is modified after physical challenge. We have hypothesized that changes in volatile molecules assessed by an electronic nose may be the reason for the alkalization of the exhaled breath condensate (EBC) fluid following physical exercise.Ten healthy young subjects performed a 6-minute running test. Exhaled breath samples pre-exercise and post-exercise (0 min, 15 min, 30 min and 60 min) were collected for volatile pattern ("smellprint") determination and pH measurements (at 5.33 kPa CO2), respectively. Exhaled breath smellprints were analyzed using principal component analysis and were related to EBC pH.Smellprints (p=0.04) and EBC pH (p=0.01) were altered during exercise challenge. Compared to pre-exercise values, smellprints and pH differed at 15 min, 30 min and 60 min following exercise (p<0.05), while no difference was found at 0 min post-exercise. In addition, a significant correlation was found between volatile pattern of exhaled breath and EBC pH (p=0.01, r=-0.34).Physical exercise changes the pattern of exhaled volatiles together with an increase in pH of breath. Changes in volatiles may be responsible for increase in EBC pH.  相似文献   

19.
The non-invasive character of exhaled breath (EBC) collection makes this fluid attractive for monitoring the respiratory tract by the measurement of various compounds. Because EBC is likely to reflect the composition of the airway-lining fluid, it can provide valuable information on possible disease states. Aim of our study was to apply proteomic technology to the study of EBC samples collected from single patients with pulmonary emphysema associated to alpha(1)-antitrypsin deficiency. The protein profiles from EBC of twenty patients and of twenty-five healthy individuals, used as controls, have been analyzed in parallel by a combination of 1-DE, 2-DE, micro-HPLC and MS. These sensitive techniques allowed to identify a number of cytokines and cytokeratins. Their level was found to be higher in patients than in controls.  相似文献   

20.
3-Nitrotyrosine (3-NT) is considered as a marker of oxidative stress, which occurs during inflammation. Since 3-NT levels in exhaled breath condensate (EBC) are very low, we applied a specific and sensitive gas chromatography-negative ion chemical ionization-mass spectrometry (GC-NICI-MS) method and high performance liquid chromatography (HPLC) with electrochemical detection for the analysis of free 3-NT in EBC. A total of 42 children (aged 5-17 years) were enrolled in this study, including children with asthma (n=12), cystic fibrosis (n=12), and healthy controls (n=18). Additionally, 14 healthy non-smoking adults (aged 18-59 years) were included. An EcoScreen system was used for the collection of EBC samples. Free 3-NT levels in EBC ranged from 0.54-6.8 nM. Median (interquartile range) concentrations (nM) were similar in all groups: 1.46 (0.97-2.49) in healthy adults, 2.51 (1.22-3.51) in healthy children, 1.46 (0.88-2.02) in children with asthma, and 1.97 (1.37-2.35) in CF children, respectively (p=0.24, Kruskall-Walis test). No difference was found between the children with airway disease and age-matched healthy controls. In healthy subjects, there was no effect of age on 3-NT concentrations. HPLC analyses provided similar concentration ranges for EBC 3-NT when compared with GC-NICI-MS. Our study has clearly demonstrated that free 3-NT in EBC fails as a marker for oxidative stress in children with stable CF and asthma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号