首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A compact biosensor platform with giant magneto-resistive (GMR) sensors suited for the detection of superparamagnetic nanoparticle labels is presented. The platform consist of disposable biosensor cartridges and an electronic reader, which enables quantitative detection with high analytical performance, combined with robustness, ease of use and at low cost. In order to optimise the signal-to-noise ratio (SNR), magnetic labels are excited at high frequency. Wires, integrated in the silicon of the sensor chip are used to generate a well-defined magnetic field on the sensor surface, thus removing the need for mechanical alignment with external apparatus. A signal modulation scheme is applied to obtain optimal detection accuracy. The platform is scalable and can be adapted according to application-specific requirements. Experimental results indicate that three beads of 300 nm diameter can be detected on a sensor surface of 1500 microm2 for a measurement time of 1s.  相似文献   

2.
A staphylococcal enterotoxin B magnetoelastic immunosensor   总被引:3,自引:0,他引:3  
A magnetoelastic immunosensor for detection of staphylococcal enterotoxin B (SEB) is described. The magnetoelastic sensor is a newly developed mass/elasticity-based transducer of high sensitivity having a material cost of approximately $0.001/sensor. Affinity-purified rabbit anti-SEB antibody was covalently immobilized on magnetoelastic sensors, of dimensions 6 mm x 2 mm x 28 microm. The affinity reaction of biotin-avidin and biocatalytic precipitation are used to amplify antigen-antibody binding events on the sensor surface. Horseradish peroxidase (HRP) and alkaline phosphatase were examined as the labeled enzymes to induce biocatalytic precipitation. The alkaline phosphatase substrate, 5-bromo-4-chloro-3-indolyl phosphate (BCIP) produces a dimer, which binds tightly to the sensor surface, inducing a change in sensor resonance frequency. The biosensor demonstrates a linear shift in resonance frequency with staphylococcal enterotoxin B concentration between 0.5 and 5 ng/ml, with a detection limit of 0.5 ng/ml.  相似文献   

3.
This paper reports on the development of a fully integrated 32-channel integrated circuit (IC) for recording neuronal signals in neurophysiological experiments using microelectrode arrays. The IC consists of 32 channels of low-noise preamplifiers and bandpass filters, and an output analog multiplexer. The continuous-time RC active filters have a typical passband of 20-2000 Hz; the low and the high cut-off frequencies can be separately controlled by external reference currents. This chip provides a satisfactory signal-to-noise ratio for neuronal signals with amplitudes greater than 50 microV. For the nominal passband setting, an equivalent input noise of 3 microV rms has been achieved. A single channel occupies 0.35 mm(2) of silicon area and dissipates 1.7 mW of power. The chip was fabricated in a 0.7 microm CMOS process.  相似文献   

4.
We demonstrate the real-time on-chip detection and manipulation of single 1 microm superparamagnetic particles in solution, with the aim to develop a biosensor that can give information on biological function. Our chip-based sensor consists of micro-fabricated current wires and giant magneto resistance (GMR) sensors. The current wires serve to apply force on the particles as well as to magnetize the particles for on-chip detection. The sensitivity profile of the sensor was reconstructed by simultaneously measuring the sensor signal and the position of an individual particle crossing the sensor. A single-dipole model reproduces the measured sensitivity curve for a 1 microm bead. For a 2.8 microm bead the model shows deviations, which we attribute to the fact that the particle size becomes comparable to the sensor width. In the range between 1 and 10 particles, we observed a linear relationship between the number of beads and the sensor signal. The real-time detection and manipulation of individual particles opens the possibility to perform on-chip high-parallel single-particle assays.  相似文献   

5.
A small array of subwavelength apertures patterned in a gold film on glass was characterized for use as a biosensor. It is widely believed that such arrays allow the resonance of photons with surface plasmons in the metallic film. Surface plasmon methods (and other evanescent wave methods) are extremely well suited for the measure of real time biospecific interactions. An extremely high sensitivity of 88,000%/refractive index unit was measured on an array with theoretical active area of .09 microm2. The formation of a biological monolayer was monitored. Both sensitivity and resolution were determined through measurement. The measured resolution, for a sensor with an active area of less than 1.5 microm2, is 9.4 x 10(-8) refractive index units which leads to a calculated sensitivity of 3.45E6%/refractive index unit. These values far exceed theoretical and calculated values of other grating coupled surface plasmon resonance (SPR) detectors and prism based SPR detectors. Because the active sensing area can be quite small (.025 microm2) single molecule studies are possible as well as massive multiplexing on a single chip format.  相似文献   

6.
Rapid and sensitive biosensor for Salmonella   总被引:2,自引:0,他引:2  
The rapid and sensitive detection of Salmonella typhymurium based on the use of a polyclonal antibody immobilized by the Langmuir-Blodgett method on the surface of a quartz crystal acoustic wave device was demonstrated. The binding of bacteria to the surface changed the crystal resonance parameters; these were quantified by the output voltage of the sensor instrumentation. The sensor had a lower detection limit of a few hundred cells/ml, and a response time of < 100 s over the range of 10(2)-10(10) cells/ml. The sensor response was linear between bacterial concentrations of 10(2)-10(7) cells/ml, with a sensitivity of 18 mV/decade. The binding of bacteria was specific with two binding sites needed to bind a single cell. The sensors preserve approximately 75% of their sensitivity over a period of 32 days.  相似文献   

7.
Mass-sensitive, magnetoelastic resonance sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted by the sensor in response to an applied, time varying, magnetic field. This magnetostrictive platform has a unique advantage over conventional sensor platforms in that measurement is wireless and remote. A biosensor for the detection of Salmonella typhimurium was constructed by immobilizing a polyclonal antibody (the bio-molecular recognition element) onto the surface of a magnetostrictive platform. The biosensor was then exposed to solutions containing S. typhimurium bacteria. Binding between the antibody and antigen (bacteria) occurred and the additional mass of the bound bacteria caused a shift in the sensor's resonant frequency. Sensors with different physical dimensions were exposed to different concentrations of S. typhimurium ranging from 10(2) to 10(9)CFU/ml. Detection limits of 5x10(3) CFU/ml, 10(5) CFU/ml and 10(7) CFU/ml were obtained for sensors with the size of 2 mmx0.4 mmx15 microm, 5 mmx1 mmx15 microm and 25 mmx5 mmx15 microm, respectively. Good agreement between the measured number of bound bacterial cells (as measured by scanning electron microscopy (SEM)) and frequency shifts was obtained.  相似文献   

8.
Two different impedance-sensor geometries have been compared for the detection of Rev peptides with a molecular weight of 2.4 kDa. Planar, two-dimensional interdigitated capacitor (IDC) sensors with electrode separations of 1.1 microm as well as three-dimensional nanogap-sensors with an electrode separation of 75 nm have been used. Both sensors have been operated at a fixed frequency of 980 MHz. We discuss the specific interaction of the Rev peptide to an immobilized RNA anti-Rev aptamer (9.2 kDa) for peptide concentrations in the range of 100 nM-2 microM. For the IDC sensor, only peptide concentrations above 500 nM gave detectable signals. For the nanogap sensor, the binding process was clearly visible for all concentrations applied. The higher sensitivity of the nanogap compared to the IDC is ascribed to the improved surface-to-volume ratio.  相似文献   

9.
We demonstrate the feasibility of using Drop-on-Demand microjet printing technology for fabricating imaging sensors by reproducibly printing an array of photo-polymerizable sensing elements, containing a pH sensitive indicator, on the surface of an optical fiber image guide. The reproducibility of the microjet printing process is excellent for microdot (i.e. micrometer-sized polymer) sensor diameter (92.2+/-2.2 microm), height (35.0+/-1.0 microm), and roundness (0.00072+/-0.00023). pH sensors were evaluated in terms of pH sensing ability (< or =2% sensor variation), response time, and hysteresis using a custom fluorescence imaging system. In addition, the microjet technique has distinct advantages over other fabrication methods, which are discussed in detail.  相似文献   

10.
Comparison of a potentiometric and a micromechanical triglyceride biosensor   总被引:1,自引:0,他引:1  
Sensitive biosensors for detection of triglyceride concentration are important. In this paper we report on two types of silicon based triglyceride sensors: an electrolyte-insulator-semiconductor capacitor (EISCAP) which is a potentiometric device and a polysilicon microcantilever. The detection principle for both sensors is based on the enzymatic hydrolysis of triglyceride though the sensing mechanisms are different: electronic for the EISCAP and mechanical for the microcantilever. The characteristics and performances of the two sensors are critically compared. The EISCAP sensor necessitates the presence of a buffer for stable measurements which limits the sensitivity of the sensor at low concentrations of the bioanalyte to 1mM. The cantilever sensor works without a buffer which improves the lower level of sensitivity to 10 microm. Both sensors are found to give reproducible and reliable results.  相似文献   

11.
Optical modes of dielectric micro-cavities have received significant attention in recent years for their potential in a broad range of applications. The optical modes are frequently referred to as "whispering gallery modes" (WGM) or "morphology dependent resonances" (MDR) and exhibit high optical quality factors. Some proposed applications of micro-cavity optical resonators are in spectroscopy1, micro-cavity laser technology2, optical communications3-6 as well as sensor technology. The WGM-based sensor applications include those in biology7, trace gas detection8, and impurity detection in liquids9. Mechanical sensors based on microsphere resonators have also been proposed, including those for force10,11, pressure12, acceleration13 and wall shear stress14. In the present, we demonstrate a WGM-based electric field sensor, which builds on our previous studies15,16. A candidate application of this sensor is in the detection of neuronal action potential.The electric field sensor is based on polymeric multi-layered dielectric microspheres. The external electric field induces surface and body forces on the spheres (electrostriction effect) leading to elastic deformation. This change in the morphology of the spheres, leads to shifts in the WGM. The electric field-induced WGM shifts are interrogated by exciting the optical modes of the spheres by laser light. Light from a distributed feedback (DFB) laser (nominal wavelength of ~ 1.3 μm) is side-coupled into the microspheres using a tapered section of a single mode optical fiber. The base material of the spheres is polydimethylsiloxane (PDMS). Three microsphere geometries are used: (1) PDMS sphere with a 60:1 volumetric ratio of base-to-curing agent mixture, (2) multi layer sphere with 60:1 PDMS core, in order to increase the dielectric constant of the sphere, a middle layer of 60:1 PDMS that is mixed with varying amounts (2% to 10% by volume) of barium titanate and an outer layer of 60:1 PDMS and (3) solid silica sphere coated with a thin layer of uncured PDMS base. In each type of sensor, laser light from the tapered fiber is coupled into the outermost layer that provides high optical quality factor WGM (Q ~ 106). The microspheres are poled for several hours at electric fields of ~ 1 MV/m to increase their sensitivity to electric field.  相似文献   

12.
In this article, a phage-based magnetoelastic sensor for the detection of Salmonella typhimurium is reported. Filamentous bacteriophage specific to S. typhimurium was used as a biorecognition element in order to ensure specific and selective binding of bacteria onto the sensor surface. Phage was immobilized onto the surface of the sensors by physical adsorption. The phage immobilized magnetoelastic sensors were exposed to S. typhimurium cultures with different concentrations ranging from 5x10(1) to 5x10(8) cfu/ml, and the corresponding changes in resonance frequency response of the sensor were studied. It was experimentally established that the sensitivity of the magnetoelastic sensors was higher for sensors with smaller physical dimensions. An increase in sensitivity from 159 Hz/decade for a 2 mm sensor to 770 Hz/decade for a 1 mm sensor was observed. Scanning electron microscopy (SEM) analysis of previously assayed biosensors provided visual verification of frequency changes that were caused by S. typhimurium binding to phage immobilized on the sensor surface. The detection limit on the order of 10(3) cfu/ml was obtained for a sensor with dimensions 1x0.2x0.015 mm.  相似文献   

13.
The BARC biosensor applied to the detection of biological warfare agents   总被引:10,自引:0,他引:10  
The Bead ARray Counter (BARC) is a multi-analyte biosensor that uses DNA hybridization, magnetic microbeads, and giant magnetoresistive (GMR) sensors to detect and identify biological warfare agents. The current prototype is a table-top instrument consisting of a microfabricated chip (solid substrate) with an array of GMR sensors, a chip carrier board with electronics for lock-in detection, a fluidics cell and cartridge, and an electromagnet. DNA probes are patterned onto the solid substrate chip directly above the GMR sensors, and sample analyte containing complementary DNA hybridizes with the probes on the surface. Labeled, micron-sized magnetic beads are then injected that specifically bind to the sample DNA. A magnetic field is applied, removing any beads that are not specifically bound to the surface. The beads remaining on the surface are detected by the GMR sensors, and the intensity and location of the signal indicate the concentration and identity of pathogens present in the sample. The current BARC chip contains a 64-element sensor array, however, with recent advances in magnetoresistive technology, chips with millions of these GMR sensors will soon be commercially available, allowing simultaneous detection of thousands of analytes. Because each GMR sensor is capable of detecting a single magnetic bead, in theory, the BARC biosensor should be able to detect the presence of a single analyte molecule.  相似文献   

14.
Qiu GM  Xu YY  Zhu BK  Qiu GL 《Biomacromolecules》2005,6(2):1041-1047
A fluorescent, magnetic composite poly(styrene-maleic anhydride) microsphere, suitable for conjugation with polysaccharide, was synthesized using magnetite/europium phthalate particles as seeds by copolymerization of styrene and maleic anhydride. The magnetite/europium phthalate particles were wrapped up by poly(ethylene glycol), which improved the affinity between the seed particles and the monomers. The composite microspheres obtained, with a diameter of 0.15-0.7 microm, contain 586-1013 microg of magnetite/g of microsphere and 0.5-16 mmol surface anhydride groups/g of microsphere. Heparin was conjugated with the reactive surface anhydride groups on the surface of the microspheres by covalent binding to obtain a fluorescent, magnetic, polysaccharide-based microsphere. The microspheres not only retain their bioactivities but also provide magnetic susceptibility and fluorescence. They can be used as a carrier with magnetic orientation and fluorescence tracer for potent drug targeting. The orientation, tracer, and anticoagulation of the fluorescence, magnetic, polysaccharide-based microspheres were studied. The anticoagulant activity of the microspheres and heparin binding capacity reached 54,212.8 U and 607.1 mg/g of dry microspheres. The activity recovery was 50.2%. The anticoagulant activity of the microspheres increases with the increase of the conjugated heparin on the surface of the microspheres and the decrease of the microsphere size. Furthermore, The fluorescent, magnetic, polysaccharide-based microspheres can be easily transported to a given position in a magnetic field and traced via their fluorescence.  相似文献   

15.
Neutron activation is an accurate analytic method in which trace quantities of isotopes of interest in a sample are activated and the emitted radiation is measured with high-resolution detection equipment. This study demonstrates the application of neutron activation for the measurement of myocardial perfusion using stable isotopically labeled microspheres. Stable labeled and standard radiolabeled microspheres (15 microm) were coinjected in an in vivo rabbit model of myocardial ischemia and reperfusion. Radiolabeled microspheres were detected with a standard gamma-well counter, and stable labeled microspheres were detected with a high-resolution Ge detection after neutron activation of the myocardial and reference blood samples. Regional myocardial blood flow was calculated from the deposition of radiolabeled and stable labeled microspheres. Both sets of microspheres gave similar measurements of regional myocardial blood flow over a wide range of flow with a high linear correlation (r = 0.95-0.99). Neutron activation is capable of detecting a single microsphere in an intact myocardial sample while providing simultaneous quantitative measurements of multiple isotope labels. This high sensitivity and capability for measuring perfusion in intact tissue are advantages over other techniques, such as optical detection of microspheres. Neutron activation also can provide an effective method for reducing the production of low-level radioactive waste generated from biomedical research. Further applications of neutron activation offer the potential for measuring other stable labeled compounds, such as fatty acids and growth factors, in conjunction with microsphere measured flow, providing the capability for simultaneous measurement of regional metabolism and perfusion.  相似文献   

16.
A localized surface plasmon resonance (LSPR) sensor surface was fabricated by the deposition of gold nanorods on a glass substrate and subsequent immobilization of the DNA aptamer, which specifically bind to thrombin. This LSPR aptamer sensor showed a response of 6‐nm λmax shift for protein binding with the detection limit of at least 10 pM, indicating one of the highest sensitivities achieved for thrombin detection by optical extinction LSPR. We also tested the LSPR sensor fabricated using gold bipyramid, which showed higher refractive index sensitivity than the gold nanorods, but the overall response of gold bipyramid sensor appears to be 25% less than that of the gold nanorod substrate, despite the approximately twofold higher refractive index sensitivity. XPS analysis showed that this is due to the low surface density of aptamers on the gold bipyramid compared with gold nanorods. The low surface density of the aptamers on the gold bipyramid surface may be due to the effect of shape of the nanostructure on the kinetics of aptamer monolayer formation. The small size of aptamers relative to other bioreceptors is the key to achieving high sensitivity by biosensors on the basis of LSPR, demonstrated here for protein binding. The generality of aptamer sensors for protein detection using gold nanorod and gold nanobipyramid substrates is anticipated to have a large impact in the important development of sensors toward biomarkers, environmental toxins, and warfare agents. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
A methodology for incorporating solubilized CdSe/ZnS core/shell nanocrystals (NCs) into functionalized carboxylated polystyrene latexes 0.3-1 microm in diameter via a swelling procedure was developed and used for the production of homogeneous, highly fluorescent polymeric beads (HFPBs), which were found to be comparable in brightness to standard polymeric microspheres doped with organic fluorophores and more photostable than the latter by more than 50 times (Fluoresbrite yellow-orange microspheres were used as an example). The three-dimensional (3D) confocal analysis of individual 1-microm HFPB demonstrated that the beads were doped with the NCs almost homogeneously. HFPBs 0.3 microm in diameter were conjugated with anti-mouse polyvalent immunoglobulins and used for immunofluorescent detection of p-glycoprotein, a mediator of the multidrug resistance phenotype, overexpressed in the membrane of MCF7r breast adenocarcinoma cells. The photostability of NCs-tagged HFPBs offers obvious advantages for the reconstruction of 3D confocal fluorescence images of antigen distribution, and their exceptionally high brightness combined with photostability permits the detection of a single antigen molecule using a standard epifluorescence microscope.  相似文献   

18.
We report a novel technique for assessing cell proliferation that employs integrated capacitance sensors for monitoring the growth of anchorage-dependent living cells. The sensors measure substrate coupling capacitances of cells cultured on-chip in a standard in vitro environment. The biophysical phenomenon underlying the capacitive behavior of cells is the counterionic polarization around the insulating cell bodies when exposed to weak, low frequency electric fields. The sensors employ charge sharing for mapping sensed capacitance values in the fF range to output voltage signals. The sensor chip has been fabricated in a commercially available 0.5microm, 2-poly 3-metal CMOS technology. We report experimental results demonstrating sensor response to the adhesion of MDA-MB-231 breast cancer cells followed by their proliferation on the chip surface. On-chip capacitance sensing offers a non-invasive, label-free, easy-to-use, miniaturized technique with real-time monitoring capability for tracking cell proliferation in vitro.  相似文献   

19.
Luminescent microspheres encapsulating glucose oxidase have recently been developed as implantable glucose sensors. Previous work has shown that the response range and sensitivity can be tuned by varying the thickness and composition of transport-controlling nanofilm coatings. Nevertheless, the linear response range of these sensors falls significantly below the desired clinical range for in vivo monitoring. We report here an alternative means of tuning the response range by adjusting microsphere porosity. A reaction-diffusion model was first used to evaluate whether increased porosity would be expected to extend the response range by decreasing the flux of glucose relative to oxygen. Sensors exhibiting linear response (R(2)>0.90) up to 600 mg/dL were then experimentally demonstrated by using amine-functionalized mesoporous silica microspheres and polyelectrolyte nanofilm coatings. The model was then used for sensor design, which led to the prediction that sensors constructed from ~12 μm microspheres having an effective porosity between 0.005 and 0.01 and ~65 nm transport-limiting coatings would respond over the entire physiological glucose range (up to 600 mg/dL) with maximized sensitivity.  相似文献   

20.
Yuk JS  Jung SH  Jung JW  Hong DG  Han JA  Kim YM  Ha KS 《Proteomics》2004,4(11):3468-3476
We have investigated whether surface plasmon resonance (SPR) sensors based on the wavelength interrogation are able to analyze protein interactions on protein arrays. The spectral SPR sensor was self-constructed and its detection limit, expressed as the minimal refractive index variation, was calculated to be 6.6x10(-5) with the signal fluctuation of 1.0x10(-5). The protein array surface was modified by a mixed thiol monolayer to immobilize proteins. Protein arrays were analyzed by the line-scanning mode of the SPR sensor, which scanned every 100 microm along the central line of array spots and the scanned results were presented by color spectra from blue to red. Glutathione S-transferase (GST)-rac1 caused a concentration-dependent increase of SPR wavelength shift on protein arrays. The surface structure of the protein arrays was analyzed by atomic force microscopy. Specific interactions of antigens with antibodies were analyzed on the protein arrays by using three antibodies and eight proteins. These results suggest that the wavelength interrogation-based SPR sensor can be used as the biosensor for the high-throughput analysis of protein interactions on protein arrays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号