1.
This study was conducted to determine whether blood pressures and pulse rate could be determined accurately by indirect measurements from the front and hind legs of 15- to 40-kg dogs anesthetized with isoflurane. Indirect measurements from each animal were compared to direct measurements obtained from a catheter placed into the abdominal aorta via the femoral artery at four ranges of systolic pressure. When systolic pressure was above 80 mm Hg, indirect measurements were either the same as direct measurements or slightly lower. However, when systolic pressures were below 80 mm Hg, indirect systolic pressure measurements were 6 to 15% higher than direct measurements. Larger differences in diastolic pressures were found, which resulted in differences in mean pressure. The most accurate measurements were found when the cuff width-to-limb circumference ratio was between 0.4 and 0.6 and when systolic pressure was between 80 and 100 mm Hg.  相似文献   

2.
Indirect measurements of arterial blood pressure were made in African green monkeys (Cercopithecus aethiops) employing a Doppler ultrasound stethoscope and standard cuff and an Infrasonde automatic blood pressure recorder. Measurements were obtained from anesthetized (10 mg/kg ketamine (HCI) and unanesthetized (1.5 mg/kg ketamine HCI) animals. Ketamine had no significant effect on blood pressure. Indirect measurements from the brachial artery were compared with direct femoral artery measurements and with each other. Systolic blood pressures measured by the Doppler (r = .948) and Infrasonde (r = .920) methods correlated closely with direct measurements but were significantly lower than systolic blood pressures measured by the direct method. Diastolic blood pressures measured by the Infrasonde method agreed closely with direct measurements (r = .947). Systolic blood pressures measured by the indirect methods correlated closely in both anesthetized (r = .973) and unanesthetized (r = .834) animals and were not significantly different. Mean blood pressures calculated from direct and Infrasonde measurements also correlated closely (r = .963), with direct measurements being 4 mmHg higher on the average. Mean blood pressures are less influenced by methodology and are more reproducible than other pressures. These noninvasive methods can be used to obtain simple and accurate measurements of blood pressure from anesthetized and unanesthetized monkeys and are of value in long-term studies in monkeys.  相似文献   

3.
Auscultatory indirect measurement of blood pressure in dogs   总被引:1,自引:0,他引:1  
An indirect method of measuring blood pressure (cuff plus stethoscope) was evaluated in 70 dogs weighing 15 to 30 kg (17.5 +/- 8.8 kg; mean +/- standard deviation). A cuff 12 cm wide was used. The measurements were most audible with the cuff on the upper foreleg of the dog and with the stethoscope placed in the medial epicondylar region just distal to the cuff. The cuff was inflated to greater than systolic pressure and allowed to deflate slowly. In 70 lightly sedated dogs, systolic blood pressures averaged 145 +/- 25 mmHg (mean +/- standard deviation) and diastolic blood pressures averaged 84 +/- 14 mmHg. Indirect measurements were compared to direct measurements (femoral arterial catheter). Systolic pressures obtained by this direct method averaged 138 +/- 29 mmHg (mean +/- standard deviation) and diastolic pressures averaged 84 +/- 17 mmHg. The correlation coefficient for systolic pressure was 0.96 and for diastolic pressure 0.97.  相似文献   

4.
Self-recording of the blood pressure by patients away from hospital or office ("home blood pressure") has been advocated as providing a better estimate of "true" blood pressure. The reliability of home blood-pressure recording has been assessed only by standard indirect methods which themselves are subject to considerable error and variability. The accuracy of self-recorded blood pressures was therefore assessed in 57 patients with essential hypertension by comparison with simultaneous measurements of clinic blood pressures and with intra-arterial blood pressures recorded at home and at hospital. Home systolic blood pressures showed good agreement with clinic and intra-arterial pressures, but home diastolic blood pressures overestimated intra-arterial pressures, as did clinic diastolic pressures. The clinic and home diastolic pressures showed good agreement. There was considerable variability in individual differences comparing the indirect and intra-arterial methods, though the two indirect methods showed much closer agreement. This study suggests that home blood pressures are as accurate as clinic readings but may be recorded more frequently and thus provide more useful information. Neither is likely to approximate the intra-arterial blood pressure.  相似文献   

5.
Direct determinations and indirect calculations of phloem turgor pressure were compared in white ash (Fraxinus americana L.). Direct measurements of trunk phloem turgor were made using a modified Hammel-type phloem needle connected to a pressure transducer. Turgor at the site of the direct measurements was calculated from the osmotic potential of the phloem sap and from the water potential of the xylem. It was assumed that the water potentials of the phloem and xylem were close to equilibrium at any one trunk location, at least under certain conditions. The water potential of the xylem was determined from the osmotic potential of xylem sap and from the xylem tension of previously bagged leaves, measured with a pressure chamber. The xylem tension of bagged leaves on a branch adjacent to the site of the direct measurements was considered equivalent to the xylem tension of the trunk at that point. While both the direct and indirect measurements of phloem turgor showed clear diurnal changes, the directly measured pressures were consistently lower than the calculated values. It is not clear at present whether the discrepancy between the two values lies primarily in the calculated or in the measured pressures, and thus, the results from both methods as described here must be regarded as estimates of true phloem turgor.  相似文献   

6.
This study investigated the role of sympathetic withdrawal on blood flow responses in cutaneous arteriovenous anastomoses (AVAs) and capillaries to direct and indirect heat stress. This was achieved by clamping sympathetic activity (SC) to the tail of anesthetized rats so that constrictor tone remained invariant during exposure of either the animal's tail (direct heating) or body (indirect heating) to a 35 degrees C environment. Flow through the AVAs in the tail was evaluated by laser-Doppler flowmetry (LDF), while capillary flow was investigated by videodensitometry measurements of blood cell velocity (CBV) in single capillaries within the subepidermal vascular plexus. Both direct and indirect heating significantly increased LDF and CBV. In comparison to blood flow responses in sham-operated control rats, the SC procedure resulted in significantly lower LDF responses to both direct and indirect heat stress. By contrast, the response of CBV was not significantly affected by SC during either mode of heating. These results indicate that the withdrawal of sympathetic constrictor tone plays a role in the response of cutaneous AVAs, but not precapillary arterioles, to direct as well as indirect heat stress. Additional studies on unanesthetized animals showed that superimposing body heating on a base of local heating elicited a further increase in LDF, suggesting that local heating does not deplete neural mediated dilatory reserve.  相似文献   

7.
We evaluated a recently developed tail-cuff apparatus for the indirect blood pressure measurement in rats with special reference to the effects of ambient temperature. For this purpose, we designed two preparations 1) an intact preparation to determine the effect of ambient temperature on blood pressure measurements and 2) an anesthetized and catheterized preparation for comparison of the values of blood pressure obtained by the indirect and by the direct method. This apparatus also required enough pulse volume oscillations to measure the accurate value of blood pressure. Sufficient pulse volume oscillations were obtained within 20 min at 30 and 40 degrees C. At 40 degrees C, the values of blood pressure, pulse rate and rectal temperature were significantly higher than those at 30 degrees C. Correlation between blood pressure and rectal temperature was significant, and blood pressure increased with rectal temperature dependently. The values of the indirect measurement were close to the values measured directly, and these correlations were highly significant. Thus, we showed the effects of temperature for indirect blood pressure measurement. This tail-cuff apparatus could measure the accurate value of indirect blood pressure without thermal stress at 30 degrees C.  相似文献   

8.
Using in vivo microscopy, we made direct measurements of pulmonary capillary transit time by determining the time required for fluorescent dye to pass from an arteriole to a venule on the dependent surface of the dog lung. Concurrently, in the same animals, pulmonary capillary transit time was measured indirectly in the entire lung using the diffusing capacity method (capillary blood volume divided by cardiac output). Transit times by each method were the same in a group of five dogs [direct: 1.75 +/- 0.27 (SE) s; indirect: 1.85 +/- 0.33 s; P = 0.7]. The similarity of these transit times is important, because the widely used indirect determinations based on diffusing capacity are now shown to coincide with direct measurements and also because it demonstrates that measurements of capillary transit times on the surface of the dependent lung bear a useful relationship to measurements on the capillaries in the rest of the lung.  相似文献   

9.
Radiotelemetry of mouse blood pressure accurately monitors systolic pressure, diastolic pressure, heart rate, and locomotor activity but requires surgical implantation. Noninvasive measurements of indirect systolic blood pressure have long been available for larger rodents and now are being reported more frequently for mice. This study compared mouse systolic arterial blood pressure measurements using implanted radiotelemetry pressure transducer with simultaneous tail-cuff measurements in the same unanesthetized mice. The pressure range for comparison was extended by inducing experimental hypertension or by observations of circadian elevations between 3 AM and 6 AM. Both trained and untrained tail-cuff operators used both instruments. Every effort was made to follow recommended manufacturer's instructions. With the initial flow-based tail-cuff instrument, we made 671 comparisons (89 sessions) and found the slope of the linear regression to be 0.118, suggesting poor agreement. In an independent assessment, 277 comparisons (35 sessions) of radiotelemetry measurements with the pulse based tail-cuff instrument were made. The slope of the linear regression of the simultaneous measurements of systolic pressures was 0.98, suggesting agreement. Bland-Altman analysis also supported our interpretation of the linear regression. Thus although reliable systolic pressure measurements are possible with either tail-cuff or radiotelemetry techniques, in our hands some tail-cuff instruments fail to accurately detect elevated blood pressures. These data, however, do not distinguish whether this instrument-specific tail-cuff failure was due to operator or instrument inadequacies. We strongly advise investigators to obtain an independent and simultaneous validation of tail-cuff determinations of mouse blood pressure before making critical genotyping determinations.  相似文献   

10.
OBJECTIVE--To compare the interobserver and intraobserver variability of blood pressure measurements in geriatric patients in atrial fibrillation and in sinus rhythm. DESIGN--Prospective assessment of blood pressure measurements carried out in random order in two groups of elderly patients by five doctors unaware of the aims of the study. SETTING--Acute assessment wards for geriatric medicine, Cardiff Royal Infirmary. PATIENTS--50 Elderly patients in sinus rhythm and 50 in atrial fibrillation. MAIN OUTCOME MEASURES--Interobserver and intraobserver variability of blood pressure measurements in the two groups expressed as the coefficient of variability and compared by the Mann-Whitney U test. RESULTS--Interobserver variability was significantly greater in the patients with atrial fibrillation for both systolic and diastolic pressures. Intraobserver variability was significantly greater in the atrial fibrillation group for diastolic pressures but the difference was not significant for systolic pressures. These differences were not related to pulse rate, age, or level of blood pressure. CONCLUSIONS--The findings suggest that in the presence of atrial fibrillation physicians'' interpretations of Korotkoff sounds are less uniform, which may have important clinical implications. Possibly a standardised methodology may overcome this problem.  相似文献   

11.
A comparison of the direct agglutination test and the indirect hemagglutination test for the detection of blood serum antibodies to Escherichia coli organisms indicated that these serological tests were comparable. In some instances the indirect hemagglutination test provided higher endpoint readings. Preparation of the antigens for the indirect hemagglutination test was more time consuming than for the direct agglutination test. Crude extract and purified polysaccharides were comparable as red blood cell sensitizing agents.  相似文献   

12.
A relatively new non-invasive method using a photo-electric flow sensor in non-heated animals, was evaluated for its accuracy in measuring systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean arterial pressure (MAP) in 40-90 Kg normotensive and hypertensive Yucatan miniature swine. Directly measured SBP, DBP and electronically averaged MAP were recorded from chronic arterial catheters simultaneously with indirect pressures, cuff pressure and tail blood flow under various conditions. In all of the tests tail cuff SBP estimation averaged within 5% of directly measured SBP. The correlation of the two methods was significant (r = .95, P less than 0.01). Over a 60 to 202 mmHg range of blood pressure induced pharmacologically or due to DOCA hypertension, the tail cuff SBP was within 4-10% of directly measured SBP. The tail cuff method was also used to determine DBP and MAP. DBP determined from the tail cuff record was found consistently to underestimate the direct measured DBP by approximately 17%. The two methods were correlated (r = .87 P less than 0.01). The measured tail cuff MAP generally underestimated the direct MAP by approximately 5%. The correlation of directly measured MAP and tail cuff methods was significant (r = .72, P less than 0.01). These results indicated that this system may be used to accurately assess blood pressure in miniature swine.  相似文献   

13.
The objective of the present study was to evaluate the precision and accuracy of facial anthropometric measurements obtained through digital 3-D surface photogrammetry with the DSP 400 system in comparison to traditional 2-D photogrammetry. Fifty plaster casts of cleft infants were imaged and 21 standard anthropometric measurements were obtained. For precision assessment the measurements were performed twice in a subsample. Accuracy was determined by comparison of direct measurements and indirect 2-D and 3-D image measurements. Precision of digital surface photogrammetry was almost as good as direct anthropometry and clearly better than 2-D photogrammetry. Measurements derived from 3-D images showed better congruence to direct measurements than from 2-D photos. Digital surface photogrammetry with the DSP 400 system is sufficiently precise and accurate for craniofacial anthropometric examinations.  相似文献   

14.
Abstract

Traditional peoples contacting modern cultures frequently experience increased levels of blood pressure. The aim of this investigation was to identify some acculturation‐related psychosocial factors which might contribute to those elevations. Young Samoans living in a traditional village, in modernizing American Samoa, and as migrants in Hawaii were studied. Casual blood pressure, anthropometric measurements, and extensive interview data were collected. The most important factor predicting variation in blood pressure was body mass (BMI). This finding was particularly evident among the acculturated and migrant Samoans. In those locations women's abandonment of breast feeding may contribute to their higher BMI. Among acculturated and migrant women, measures of social support favored lower blood pressures. Among men in all locations a greater number of close social ties was linked to higher blood pressures with the exception of ties with parents. Parental ties were linked to substantially lower blood pressures. A knowledge of Samoan traditions favored lower blood pressure among migrant men, while knowledge of American culture favored higher pressures. Coping strategies and complaint behavior were also significant contributors in all locations.  相似文献   

15.
Recent studies with Nile tilapia have shown divergent results regarding the possibility of selecting on morphometric measurements to promote indirect genetic gains in fillet yield (FY). The use of indirect selection for fillet traits is important as these traits are only measurable after harvesting. Random regression models are a powerful tool in association studies to identify the best time point to measure and select animals. Random regression models can also be applied in a multiple trait approach to analyze indirect response to selection, which would avoid the need to sacrifice candidate fish. Therefore, the aim of this study was to investigate the genetic relationships between several body measurements, weight and fillet traits throughout the growth period and to evaluate the possibility of indirect selection for fillet traits in Nile tilapia. Data were collected from 2042 fish and was divided into two subsets. The first subset was used to estimate genetic parameters, including the permanent environmental effect for BW and body measurements (8758 records for each body measurement, as each fish was individually weighed and measured a maximum of six times). The second subset (2042 records for each trait) was used to estimate genetic correlations and heritabilities, which enabled the calculation of correlated response efficiencies between body measurements and the fillet traits. Heritability estimates across ages ranged from 0.05 to 0.5 for height, 0.02 to 0.48 for corrected length (CL), 0.05 to 0.68 for width, 0.08 to 0.57 for fillet weight (FW) and 0.12 to 0.42 for FY. All genetic correlation estimates between body measurements and FW were positive and strong (0.64 to 0.98). The estimates of genetic correlation between body measurements and FY were positive (except for CL at some ages), but weak to moderate (−0.08 to 0.68). These estimates resulted in strong and favorable correlated response efficiencies for FW and positive, but moderate for FY. These results indicate the possibility of achieving indirect genetic gains for FW and by selecting for morphometric traits, but low efficiency for FY when compared with direct selection.  相似文献   

16.
The pharmacokinetics and efficacy of gentamicin after its direct and indirect endolymphatic administration were comparatively studied. It was shown that the time course of the blood pharmacokinetics of the antibiotic was almost the same as under the both conditions. Therefore, in many cases the less complicated and more available indirect endolymphatic therapy may replace the direct labor-consuming and traumatic endolymphatic administration of drugs.  相似文献   

17.
The vapor pressures of dog''s blood and blood plasma were determined at 37.5° by the dynamic method and the osmotic pressures calculated from the experimental data. The vapor pressures calculated from experimentally determined freezing point data agreed, within the experimental error, with the values obtained from direct measurement. The vapor pressure lowering produced by the colloid constituents of the blood was also determined and found to be minimal compared to that of the other constituents.  相似文献   

18.
A new tail cuff method for determining systolic and mean blood pressure in rats was developed based on photoelectric detection of tail arterial blood flow and pulsatile volume oscillation. Indirect systolic and mean blood pressure measured by this method correlated well with direct systolic and mean blood pressures recorded by a transducer and polygraph after carotid artery cannulation in stroke-resistant spontaneously hypertensive rats (SHR), stroke-prone SHR and normotensive Wistar Kyoto rats. Blood pressures were sharply, and transiently raised for about 1 min when rats were picked up by an investigator to be placed in a hot box or immobilized in a restrainer for measuring blood pressure. Therefore, blood pressures should be measured at least 1 min after the rats are put in a restrainer. This new tail cuff method for measuring blood pressure provides reliable mean blood pressure readings in conscious rats.  相似文献   

19.
The results of direct pressure measurements are described which demonstrate that pressures in a certain fraction of mesenteric capillaries remain remarkably constant during large changes in systemic pressure. The results of isogravimetric studies, reported in the literature, are also described which indicate that this phenomenon may also occur in the intestine. The question is raised whether capillary pressures may therefore be regulated. Pressures recorded from mesenteric arterioles and capillaries are shown which indicate that maintenance of a constant capillary pressure is primarily the consequence of the vascular architecture peculiar to this tissue, and is merely a secondary reflection of mechanisms associated with flow regulation. The results of direct pressure measurements recorded in the microcirculation of intestinal muscle are also shown. These data indicate that capillary pressures in innervated, denervated, and xylocaine-treated intestinal muscle change in direct proportion to variations in arterial pressure. It is concluded that capillary pressures in the intestinal muscle layers are therefore not regulated, so that the observation that capillary pressures may be maintained is probably a phenomenon unique to the mesentery. Pressures recorded from capillaries in the mucosal villi are also shown and compared to capillary pressures measured in the microvasculature of mesentery and intestinal muscle. When systemic pressure was normal (107 +/- 10 mm Hg), capillary pressure in the mesentery averaged 30 to 33 mm Hg; capillary pressures in the intestinal muscle averaged 22 to 24 mm Hg; and capillary pressures in the mucosal villi averaged 13 to 15 mm Hg. These data suggest that mesenteric capillaries are primarily a filtering network; intestinal muscle capillaries are normally in fluid balance; whereas at rest mucosal capillaries are primarily absorptive. These pressures, recorded from the three major regions of the rat intestine, were used to calculate a weighted average for the whole organ. The calculated value, based on assumed values for relative capillary densities, was 17 mm Hg. This result compares favorably with data from whole organ, isogravimetric studies, and may clarify some of the apparent discrepancies between previous isogravimetric and servopressure studies.  相似文献   

20.
Intrahepatic blood volume-pressure relationships were studied using plethysmography to measure hepatic blood volume and a hepatic venous long-circuit to control intrahepatic pressure. In cats anesthetized with pentobarbital or with ketamine-chloralose, hemorrhage (to reduce hepatic blood flow to 60% of control) caused marked reductions in hepatic blood volume and intrahepatic pressure but did not significantly change hepatic blood volume-pressure relationships. We were unable to demonstrate an active reflex venous response to hemorrhage in these preparations, although a large passive response occurred. The volume-pressure relationships in innervated livers were different from those in denervated livers: apparent venous compliance was much greater and apparent unstressed volume was zero or negative. Hepatic nerve stimulation in denervated livers caused a marked decrease in hepatic blood volume at low intrahepatic pressures but failed to alter hepatic blood volumes at high intrahepatic pressures (15 mmHg) (1 mmHg = 133.3 Pa). This resulted in large apparent compliances and apparently negative unstressed volumes, as seen in the innervated livers. Thus blood volume-pressure relationships in innervated livers may not give valid measurements of compliance and unstressed volume. A remarkable feature in all these experiments was the linearity of the relationship between hepatic blood volume and intrahepatic pressure. Exudation of fluid begins at higher intrahepatic pressures in innervated compared with denervated livers.  相似文献   