1.
The use of spacers to distance an immobilized antibody from the surface of a support matrix introduces flexibility, which can reduce steric interferences between antibodies leading to a higher antigen capture efficiency. In this paper we investigated the use of a spacer molecule, poly-ethylene glycol (PEG), between the matrix surface and antibodies for the capture of Bacillus globigii, E. coli O157:H7, and ovalbumin. The antigen capture efficiency was determined using a surface ELISA method. Antibodies against the antigens were covalently immobilized either directly or via PEG to glass surfaces using a one-step EDC reaction. The amount of antibody immobilized was determined before blocking the nonspecific binding sites with bovine serum albumin. Antibodies immobilized via a PEG spacer showed a higher capture efficiency compared to direct immobilization, which was more pronounced with large antigens. Antibodies immobilized on glass supports were stable at 65 degrees C for at least 80 min, and the capture efficiency increased with heating at 65 degrees C for 20 min.  相似文献   

2.
To determine the intermolecular force on protein-protein interaction (PPI) by atomic force microscopy (AFM), a photograft-polymer spacer for protein molecules on both surfaces of the substrate and AFM probe tip was developed, and its effectiveness was assessed in a PPI model of a pair of human serum albumin (HSA) and its monoclonal antibody (anti-HSA). A carboxylated photoiniferter, N-(dithiocarboxy)sarcosine, was derivatized on both surfaces of the glass substrate and AFM probe tip, and subsequently water-soluble nonionic vinyl monomers, N,N-dimethylacrylamide (DMAAm), were graft-polymerized on them upon ultraviolet light irradiation. DMAAm-photograft-polymerized spacers with carboxyl groups at the growing chain end but with different chain lengths on both surfaces were prepared. The proteins were covalently bound to the carboxyl terminus of the photograft-polymer chain using a water-soluble condensation agent. The effects of the graft-spacer length on the profile of the force-distance curves and on the unbinding characteristics (unbinding force and unbinding distance) were examined in comparison with those in the case of the commercially available poly(ethylene glycol) (PEG) spacer. The frequency of the nonspecific adhesion force profile was markedly decreased with the use of the photograft spacers. Among the force curves detected, a high frequency of single-peak curves indicating the unbinding process of a single pair of proteins and a very low frequency of multiple-peak profiles were observed for the photograft spacers, regardless of the graft chain length, whereas a high frequency of no-force peaks was noted. These observations were in marked contrast with those for the PEG spacer. The force peak values determined ranged from 88 to 94 pN, irrespective of the type of spacer, while the standard deviation of force distribution observed for the photograft spacer was lower than that for the PEG spacer, indicating that the photograft spacers provide a higher accuracy of force determination.  相似文献   

3.
Development of immunobiosensor detector surfaces involves the immobilization of active antibodies on the capture surface without any significant loss of antigen binding activity. An atomic force microscope (AFM) was used to directly evaluate specific interactions between pesticides and antibodies on a biosensor surface. Oriented immobilization of antibodies against two herbicide molecules 2,4-dichlorophenoxyacetic acid (2,4-D) and atrazine, on gold, was carried out to create the active immunobiosensor surfaces. The adhesive forces between immobilized antibodies and their respective antigens were measured by force spectroscopy using hapten-carrier protein functionalized AFM cantilevers. Relative functional affinity (avidity) measurements of the antibodies carried out prior to immobilization, well correlated with subsequent AFM force measurement observations. Analysis showed that immobilization had not compromised the reactivity of the surface immobilized antibody molecules for antigen nor was there any change in their relative quality with respect to each other. The utility of the immunoreactive surface was further confirmed using a Surface Plasmon Resonance (SPR) based detection system. Our study indicates that AFM can be utilized as a convenient immunobiosensing tool for confirming the presence and also assessing the strength of antibody-hapten interactions on biosensor surfaces under development.  相似文献   

4.
The microscopic surface molecular structures and macroscopic electrochemical impedance properties of the epoxysilane monolayer and anti-Escherichia coli antibody layer on an indium-tin oxide (ITO) electrode surface were studied in this paper. Characterization of stepwise changes in microscopic features of the surfaces and electrochemical properties upon the formation of each layer were carried out using both atomic force microscopy (AFM) and electrochemical impedance spectroscopy in the presence of [Fe(CN)6](3-/4-) as a redox couple. AFM images of the self-assembled monolayer (SAM) evidenced the dense, complete, and homogeneous morphology of the epoxysilane monolayer on the ITO surface. The uniformity of the epoxysilane SAM allowed antibodies to attach to the epoxy surface groups of the silanes in a similarly uniform fashion. The effects of epoxysilane monolayer and the antibody layer on the electrochemical properties of the electrode were quantitatively analyzed in terms of double layer capacitance, electron transfer resistance, Warburg impedance and solution resistance using Randles model as the equivalent circuit. It was demonstrated that the epoxysilane monolayer and the antibody layer act as barriers for the electron transfer between the electrode surface and the redox species in the solution, resulting in most significant increases in the electron transfer resistance compared to all the electric elements. Immunoreaction with E. coli O157:H7 cells demonstrated specific recognition of the immobilized anti-E. coli antibodies as evidenced by AFM imaging and impedance spectroscopy. It was found that the binding of E. coli cells mainly affected the electron transfer resistance and Warburg impedance.  相似文献   

5.
Factors affecting the specific activity of immobilized antibodies and their biologically active fragments were studied with goat anti-mouse and goat anti-human immunoglobulin G. Antibodies were immobilized on HW 65 polymeric support matrix activated with carbonyldiimidazole, hydrazide and iodoacetic acid. The most significant factors influencing the specific activity of stochastic coupling of antibodies are multisite attachment, multiple orientations and steric hindrance imposed by crowding of antibody and the size of the antigen. In oriented immobilization the specific activity is affected only by steric hindrance. The specific activity of immunosorbents prepared by immobilization of F(ab′) fragments can be improved to almost 100% by limiting the amount of protein immobilization and the size of the antigen. The present study shows the protocols for optimizing immobilized antibody performance.  相似文献   

6.
One critical aspect for the development of label-free immunosensors is the employment of highly uniform and repeatable antibody immobilization techniques. In this study, we investigated the use of two different silane molecules (3-glycidyloxypropyl)trimethoxysilane (GPS), and (3-mercaptopropyl)trimethoxysilane (MTS) for the immobilization of fluorescently labeled IgG antibodies on planar ZnO surfaces. The chemical modification of the surfaces was investigated using water contact angle measurements, AFM, and fluorescence microscopy. The results of the water contact angle measurements indicate increased surface hydrophobicity after treatment with GPS and MTS as compared to the control. Surface modification was further verified through AFM measurements which demonstrate an increased surface roughness and particle height after treatment with antibodies. The results of the fluorescence studies indicate that the immobilization protocol employing MTS produced 21% higher fluorescence on average with greater uniformity than the GPS-based protocol, which indicates a higher overall density in antibody coverage on the surface of the ZnO. Acoustic sensor tests were employed to confirm the functionality of sensors treated with the MTS protocol. The results indicate that the immobilization protocol imparts sensitivity and specificity to the ZnO-based devices.  相似文献   

7.
Impedance spectroscopy approaches combined with the immunosensor technology have been used for the determination of trace amounts of ciprofloxacin antibiotic belonging to the fluoroquinolone family. The sensor electrode was based on the immobilization of anti-ciprofloxacin antibodies by chemical binding onto a poly(pyrrole-NHS) film electrogenerated on a solid gold substrate. The electrode surface was modified by electropolymerization of pyrrole-NHS, antibody grafting and ciprofloxacin immunoreaction. The sensitive steps of surface modification, cyclic voltammetry (CV) and atomic force microscopy (AFM) imaging have been used for electrode surface characterization. The immunoreaction of ciprofloxacin on the grafted anti-ciprofloxacin antibody directly triggers a signal via impedance spectroscopy measurements which allows the detection of extremely low concentration of 10 pg/ml ciprofloxacin.  相似文献   

8.
Poly(styrene-acrylic acid) magnetic microspheres with an average diameter of 2 μm were successfully prepared and used as carriers to immobilize lipase. Lipase immobilized on microspheres with no spacer arm exhibited low activities, which were attributed to steric hindrance on the lipase conformation. To avoid steric effects, ethylenediamine and poly(ethylene glycol) (PEG) 400/800/4000 were utilized as spacer arms to bind the lipase to the microspheres. The immobilized lipase activities were improved using PEG 800/4000 as a spacer arm. Furthermore, the influence of enzyme loading on lipase activity was investigated, and the results indicated that enzyme overloading could exert steric effect on lipase activity. The degree of PEG modification was demonstrated to affect lipase activity because excess PEG on the surface of microspheres could interact with lipase due to its mobility, consequently reducing lipase activity.  相似文献   

9.
A biosensor chip utilizing surface plasmon resonance (SPR) was fabricated for detecting anti-glutamic acid decarboxylase (GAD) antibody, which is an indicator of the presence of type I diabetes mellitus. The sensor surfaces were constructed from various thiol mixtures of different molar ratios of 3-mercaptopropionic acid (3-MPA) to 11-mercaptoundecanoic acid (11-MUA). To determine the surface characteristics of the different alkanethiol monolayers, several quantitative and kinetic measurements were carried out. The extent of immobilization of streptavidin (SA) and biotin-GAD (the anti-GAD receptor) and the immune response of anti-GAD antibody against GAD were measured using the SPR biosensor. The terminal functional group of a thiol has different effects on the adsorption and covalent binding of protein depending on the steric hindrance. The protein chip described herein permits simple, rapid detection of anti-GAD antibody.  相似文献   

10.
To enhance the feasibility of surface plasmon resonance (SPR) immunosensor as a tool for diagnosing type I diabetes, we enhanced the sensitivity of immunoresponse for detecting the monoclonal anti-glutamic acid decarboxylase (GAD) antibody by modification of mixed self-assembled monolayers (SAMs). The effects of the different mixed SAMs were evaluated with respect to the degree of streptavidin immobilization, the degree of biotin-GAD immobilization, and the immunoresponse sensitivity. Consequently, the sensitivity of the immunoresponse for the detection of anti-GAD antibody was enhanced as a result of the reduction in steric hindrance brought about by using SAMs of heterogeneous lengths. The immunoresponse for detecting the monoclonal anti-GAD antibody was also enhanced with the reduction of the excess immobilization of biotin-GAD and the minimization of non-specific binding that resulted from the simple substitution of the spacer from a carboxylic-terminated SAM for the hydroxyl-terminated SAM.  相似文献   

11.
Immunosensors, based on the immobilization of a model rabbit antibody on mixed self-assembled monolayers and Protein A as a linking agent on gold transducers, were elaborated and characterized at each step by modulated polarization-infrared spectroscopy (PM-IRRAS) and occasionally by atomic force microscopy (AFM) and quartz crystal microbalance (QCM). By testing two different mixed SAMs comprising 11-mercaptoundecanoic acid (MUA), together with either decanethiol (C9CH3) or mercaptohexanol (C6OH), the role of the chemical composition and structure of the antibody attachment layer upon the sensor performance was demonstrated.  相似文献   

12.
Spin-coated thin films of poly(N-hydroxysuccinimidyl methacrylate) (PNHSMA) on oxidized silicon and gold surfaces were investigated as reactive layers for obtaining platforms for biomolecule immobilization with high molecular loading. The surface reactivity of PNHSMA films in coupling reactions with various primary amines, including amine-terminated poly(ethylene glycol) (PEG-NH2) and fluoresceinamine, was determined by Fourier transform infrared (FTIR) spectroscopy, X-ray photoelectron spectroscopy (XPS), fluorescence microscopy, and ellipsometry measurements, respectively. The rate constants of PEG-NH2 attachment on the PNHSMA films were found to be significantly increased compared to the coupling on self-assembled monolayers (SAMs) of 11,11'-dithiobis(N-hydroxysuccinimidylundecanoate) (NHS-C10) on gold under the same conditions. More significantly, the PEG loading observed was about 3 times higher for the polymer thin films. These data indicate that the coupling reactions are not limited to the very surface of the polymer films, but proceed into the near-surface regions of the films. PNHSMA films were shown to be stable in contact with aqueous buffer; the swelling analysis, as performed by atomic force microscopy (AFM), indicated a film thickness independent swelling of approximately 2 nm. An increased loading was also observed by surface plasmon resonance for the covalent immobilization of amino-functionalized probe DNA. Hybridization of fluorescently labeled target DNA was successfully detected by fluorescence microscopy and surface plasmon resonance enhanced fluorescence spectroscopy (SPFS), thereby demonstrating that thin films of PNHSMA comprise an attractive and simple platform for the immobilization of biomolecules with high densities.  相似文献   

13.
To utilize aptamers as molecular recognition agents in biosensors and biodiagnostics, it is important to develop strategies for reliable immobilization of aptamers so that they retain their biophysical characteristics and binding abilities. Here we report on quartz crystal microbalance (QCM) measurements and atomic force microscope (AFM)-based force spectroscopy studies to evaluate aptasensors fabricated by different modification strategies. Gold surfaces were modified with mixed self assembled monolayers (SAMs) of aptamer and oligoethylene glycol (OEG) thiols (HS-C(11)-(EG)(n)OH, n=3 or 6) to impart resistance to nonspecific protein adsorption. By affinity analysis, we show that short OEG thiols have less impact on aptamer accessibility than longer chain thiols. Backfilling with OEG as a step subsequent to aptamer immobilization provides greater surface coverage than using aptamer and OEG thiol to form a mixed SAM in one-step. Immunoglobulin E and vascular endothelial growth factor (VEGF) were studied as target proteins in these experiments. Binding forces obtained by these strategies are similar, demonstrating that the biophysical properties of the aptamer on the sensors are independent from the immobilization strategy. The results present mixed SAMs with aptamers and co-adsorbents as a versatile strategy for aptamer sensor platforms including ultrasensitive biosensor design.  相似文献   

14.
A functionalized microwire sensor based on dielectrophoresis (DEP) and antigen-antibody reaction was initially developed for sensitive and selective detection of E. coli O157:H7. The dynamics of gold-tungsten microwires were manipulated using an automated X-Y-Z stage and the sensing process included antibody immobilization and bacterial detection, and cell quantification. Antibodies were first immobilized on surface of the microwire to improve sensing specificity, and then coupled with DEP for capture of E. coli cells in a mixture of E. coli cells and non-conductive polystyrene beads. Afterward, fluorescein-conjugated secondary antibodies were applied to the wire for quantification of captured bacteria. Field Emission Scanning Electron Microscope (FESEM) figures and fluorescence intensities of bacteria on the wire validated the sensing mechanism. The entire immobilization and detection procedure could be completed within 30 min with simple operations. Performance of the microwire sensor was not significantly affected when conducted in orange juice. In addition, the detection limit of this sensor was about 5 bacterial cells per microwire in 1000 CFU/mL bacterial suspensions when the electric field generated at 3 MHz and 20 peak to peak voltage (V(pp)), and only targeted E. coli cells were concentrated and captured.  相似文献   

15.
The immobilization of biomolecules on surfaces in defined micropatterns has become increasingly important for the development of new diagnostic devices and high-throughput genetic and drug screening protocols. We describe the synthesis and testing of thiol-reactive, photoactivatable linkers that will permit laser micropatterning or photolithographic patterning of surfaces. In these linkers, a benzophenone photophore is tethered through a variable-length poly(ethylene glycol) hydrophilic spacer to a maleimide group. Spacers containing one to five ethylene glycol units were examined. Antibodies were photoimmobilized on polystyrene waveguides and the resulting biosensors were used for fluorescence immunoassays. The spacer with five ethylene glycol units optimally decreased the steric interactions among large molecules (antibodies and antigens) and increased binding capacity and response rate of the biosensor. Two different sandwich assay protocols were examined. In the first, the antigen and fluorescently labeled second antibody were added sequentially to the biosensor ("stepwise"). In the second, the antigen and antibody were premixed before injection into the biosensor ("premixed"). The stepwise protocol gave a significantly higher response than that of the premixed protocol. Although the premixed protocol is more convenient, the stepwise protocol provides enhanced sensitivity.  相似文献   

16.
This paper describes a simple strategy for covalent immobilization of the NHS-PEG-RGD peptide with the three different PEG lengths (8, 13, and 22) onto the amine-terminated monolayers with the subsequent investigation of fibroblast cellular response to the three derivatives of pegylated RGD peptides-modified substrates. First, acetamide-terminated monolayers were prepared on the hydride terminated silicon surface to protect NH2-terminated monolayers. This was followed by the removal of the protective groups, and the reaction of NHS-PEG8-RGD, NHS-PEG13-RGD and NHS-PEG22-RGD peptides with the NH2-terminated monolayers while reducing nonspecific protein adsorption. Analysis of X-ray photoelectron spectroscopy (XPS), Fourier Transform Infrared (ATR-FTIR) spectroscopy, and Ellipsometry measurements demonstrated that PEG13-RGD peptide forms relatively a more homogenous, thicker and stable structure compared with those of PEG8-RGD and PEG22-RGD peptide. The quantitative and qualitative assessment of cell adhesion, spreading, and proliferation indicated that relatively further elongated fibroblast cells attached on the PEG13-RGD peptide relative to those on the PEG8-RGD and PEG22-RGD peptide. The results presented here may offer a developed strategy based on the length of the spacer to regulate cellular behavior on the surface substrates.  相似文献   

17.
We report the investigation of biotin-streptavidin binding interactions using microcantilever sensors. A symmetric cantilever construction is employed to minimize the effects of thermal drift and the control of surface chemistry on the backside of the cantilever is demonstrated to reduce the effects of non-specific binding interactions on the cantilever. Three structurally different biotin modified cantilever surfaces are used as a model system to study the binding interaction with streptavidin. The cantilever response to the binding of streptavidin on these biotin sensing monolayers is compared. The lowest detection limit of streptavidin using biotin-HPDP is found to be between 1 and 10nM limited by the optical measurement setup. Surface characterization using quartz crystal microbalance (QCM) and high-resolution atomic force microscope (AFM) is used to benchmark the cantilever sensor response. In addition, the QCM and AFM studies reveal that the surface density of bound streptavidin on biotin modified surfaces was low, thereby implying that effects other than steric hindrance are responsible for defining cantilever response.  相似文献   

18.
An anchor-chain molecular system was constructed for controlled orientation and high activity in enzyme immobilization. A streptavidin recognition peptide (streptag) coding sequence was fused to the 3' end of the phoA gene, which codes for E. coli alkaline phosphatase (EAP). Both the wild-type (WT) and the Asp-101 --> Ser (D1O1S) mutant were modified with the streptag sequence with or without the insertion of a flexible linker peptide [-(Gly-Ser)(5)-] coding sequence. The fused genes were cloned into the vector pASK75 and expressed in the periplasm of the host cell Escherichia coli SM547. The proteins were released by osmotic shock and purified by ion-exchange chromatography. Enzyme activities of all proteins were measured spectrophotometrically with rho-nitrophenyl phosphate as the substrate. Specific activities of D101S-streptag and D101S-linker-streptag enzymes were increased 25- or 34-fold over the WT, respectively. These fusion proteins were then immobilized on microtiter plates through streptag-streptavidin binding reaction. After immobilization, the D101S-linker-streptag enzyme displayed the highest residual activity and the ratio of enzyme activities of the linker to nonlinker enzymes was 8.4. These results show that the addition of a linker peptide provides a spacer so as to minimize steric hindrance between the enzyme and streptavidin. The method provides a solution for controlled enzyme immobilization with high recover activity, which is especially important in construction of biosensors, biochips, or other biodevices.  相似文献   

19.
The atomic force microscopy (AFM) has been used as a force sensor to measure unbinding forces of single bound complexes in the nanonewton and piconewton range. Force spectroscopy measurements can be applied to study both intermolecular and intramolecular interactions of complex biological and synthetic macromolecules. Although the AFM has been extensively used as a nano force sensor, the commercially available cantilever is limited to silicon and silicon nitride. Those materials reduce the adhesion sensitivity with specific surface and/or molecule. Here, we functionalized the AFM tip with carboxylic groups by applying acrylic acid (AA) vapor at radio frequency plasma treatment at 100 W for 5 min. This method provides a remarkable sensitivity enhancement on the functional group interaction specificity. The functionalized tip was characterized by scanning electron microscopy. The electron beam high resolution images have not shown significant tip sharpness modification. Silicon wafers (1 0 0)-no treated and functionalized by AA plasma treatment-were characterized by Auger electron spectroscopy to elucidate the silicon surface sputtering and demonstrate functionalization. The Fourier transform-infrared spectroscopy spectrum shows a high absorbance of avidin protein over the silicon surface functionalized by AA plasma treatment.We carried out force spectroscopy assay to measure the unbinding force between the well-established pair biotin-avidin. At pulling speed of 2 μm/s, we measured the unbinding force of 106?±?23 pN, which is in good agreement with the literature, demonstrating the effectiveness of the tip functionalization by AA plasma treatment in biological studies.  相似文献   

20.
Antibody immobilization on a solid surface is inevitable in the preparation of immunochips/sensors. Antibody-binding proteins such as proteins A and G have been extensively employed to capture antibodies on sensor surfaces with right orientations, maintaining their full functionality. Because of their synthetic versatility and stability, in general, small molecules have more advantages than proteins. Nevertheless, no small molecule has been used for oriented and specific antibody immobilization. Here is described a novel strategy to immobilize an antibody on various sensor surfaces by using a small antibody-binding peptide. The peptide binds specifically to the Fc domain of immunoglobulin G (IgG) and, therefore, affords a properly oriented antibody surface. Surface plasmon resonance analysis indicated that a peptide linked to a gold chip surface through a hydrophilic linker efficiently captured human and rabbit IgGs. Moreover, antibodies captured by the peptide exhibited higher antigen binding capacity compared with randomly immobilized antibodies. Peptide-mediated antibody immobilization was successfully applied on the surfaces of biosensor substrates such as magnetic particles and glass slides. The antibody-binding peptide conjugate introduced in this work is the first small molecule linker that offers a highly stable and specific surface platform for antibody immobilization in immunoassays.  相似文献   