首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of salidroside, a major active constituent from Rhodiola rosea L., in rat plasma using helicid as an internal standard. The method involves a simple single-step liquid-liquid extraction with n-butanol. The analytes were separated by isocratic gradient elution on a Shim-pack ODS (4.6 microm, 250 mmx2.0 mm i.d.) column and analyzed in selected ion monitoring (SIM) mode with a negative electrospray ionization (ESI) interface using the respective [M+Cl]- ions, m/z 335 for salidroside, m/z 319 for internal standard. The method was validated over the concentration range of 5-2000 ng/mL for salidroside. Within- and between-batch precision (R.S.D.%) were all within 6% and accuracy ranged from 96 to 112%. The lower limits of quantification was 5 ng/mL. The extraction recovery was on average 86.6% for salidroside. The validated method was used to study the pharmacokinetic profile of salidroside in rat plasma after intravenous and oral administration of salidroside. The bioavailability of salidroside in rats is 32.1%.  相似文献   

2.
A rapid, sensitive and specific method for quantifying the aromatase inhibitor (anastrozole) in human plasma using dexchlorpheniramine as the internal standard (I.S.) is described herein. The analyte and the I.S. were extracted from 200 microl of human plasma by liquid-liquid extraction using a mixture of diethyl ether:dichloromethane (70:30, v/v) solution. Extracts were removed and dried in the organic phase then reconstituted with 200 microl of acetonitrile:water (50:50; v/v). The extracts were analyzed by high performance liquid chromatography coupled with photospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed isocratically on a Genesis, C18 4 microm analytical column (100 mm x 2.1mm i.d.). The method had a chromatographic run time of 2.5 min and a linear calibration curve ranging from 0.05-10 ng ml(-1). The limit of quantification (LOQ) was 0.05 ng ml(-1). This HPLC-MS-MS procedure was used to assess pharmacokinetic studies.  相似文献   

3.
MS23 is a vasodilator with unique dual action pharmacological profile to inhibit type 4 PDE and antagonize L-type calcium channels. We validated an analytical protocol for MS23 in rat plasma using high performance liquid chromatography (HPLC). A C18 column and a phosphate/acetonitrite buffer were used for chromatographic separation. UV detection was performed at 307 nm. The calibration curve for MS23 was linear in the range from 50 to 10,000 ng/ml. The limit of quantification (LOQ) was 50 ng/ml. The results demonstrate that the method has linearity (R = 0.9989), specificity, and acceptable precision/accuracy. This method is simple, economic, and sufficient for in vivo pharmacokinetic studies on the compound.  相似文献   

4.
The validation of a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the determination of the selective cyclooxygenase-2 inhibitor etoricoxib in human plasma with phenazone as internal standard is described. The plasma samples were extracted by solid-phase extraction using polymer-based cartridges. Chromatography was carried out on a short, narrow bore RP C(18) column (30x2 mm). Detection was achieved by a Sciex API 3000 triple quadrupole mass spectrometer equipped with a turbo ion spray source working in positive ion mode. The respective mass transitions used for quantification of etoricoxib and phenazone were m/z 359.2-->280.2 and m/z 189.0-->104.1. The analytical method was validated over the concentration range 0.2-200 ng/ml. The limit of quantification was 0.2 ng/ml. The method is applicable to pharmacokinetic studies in humans.  相似文献   

5.
We have established a robust, fully automated analytical method for the determination of indomethacin in rat plasma using a column-switching high-performance chromatographic system. The system consists of a precolumn and an analytical column connected in series via a switching valve. When a 50-microl portion of rat plasma containing a therapeutic level of indomethacin was applied directly to the system, the drug was automatically enriched in the precolumn (TSK BSA-ODS) by on-line solid-phase extraction. After elution of the plasma proteins, the analyte was automatically transferred to the analytical column (Zorbax Eclipse XDBC18) where chromatography was performed using isocratic elution and UV absorption detection at a wavelength of 254 nm. The separation mobile phase consisted of methanol-0.1% phosphoric acid (70:30, v/v) at a flow-rate of 1 ml/min. The calibration line for indomethacin showed good linearity in the range 50-10 000 ng/ml (r>0.999) with the detection quantification of 50 ng/ml (RSD=2.6%). Accuracy ranged from -0.62 to 3.22%, and the within- and between-day precision of the assay was better than 6% across the calibration range. The analytical sensitivity and accuracy of this assay is suitable for characterization of the pharmacokinetics of topical administration of imdomethacin to rats. The method has been successfully used to provide pharmacokinetic data in a large number of diverse pharmaceutical studies.  相似文献   

6.
A sensitive and specific liquid chromatography electrospray ionization-tandem mass spectrometry method for the enantioselective determination of the novel beta-adrenolytic compound, 1-(1-H-indol-4-yloxy)-3-{[2-(2-methoxyphenoxy)ethylo]amino} propan-2-ol, in rat plasma has been developed and validated. Chromatography was performed on a reversed-phase Chiralcel OD-RH analytical column (150x4.6 mm, 5 microm, Daicel Chemical Industries, Tokyo, Japan) with isocratic elution using a mobile phase containing acetonitrile and water with 0.01% formic acid. Detection was achieved by an Applied Biosystems MDS Sciex (Concord, Ontario, Canada) API 2000 triple quadrupole mass spectrometer. Electrospray ionization (ESI) was used for ion production. The limit of detection in the MRM mode was found to be 1.25 ng/ml. The limit of quantification of both enantiomers was 2.5 ng/ml. The precision and accuracy for both intra- and inter-day determination of 2F109 enantiomers ranged from 2.6 to 12% and from 89.1 to 107.1%. This analytical method allowed us to carry out pharmacokinetic studies in rats. Our findings demonstrate that 2F109 shows stereoselective disposition in rat plasma after i.v. administration. The terminal half-lives of (+)-(R)-2F109 and (-)-(S)-2F109 were 33.5 and 42.6 min, respectively. The AUC0-inf of (+)-(R)-2F109 exceeded that of (-)-(S)-2F109.  相似文献   

7.
We have developed a simple, sensitive, specific and reproducible stereoselective high-performance liquid chromatography technique for analytical separation of cisapride enantiomers and measurement of cisapride enantiomers in human plasma. A chiral analytical column (ChiralCel OJ) was used with a mobile phase consisting of ethanol–hexane–diethylamine (35:64.5:0.5, v/v/v). This assay method was linear over a range of concentrations (5–125 ng/ml) of each enantiomer. The limit of quantification was 5 ng/ml in human plasma for both cisapride enantiomers, while the limit of detection was 1 ng/ml. Intra- and inter-day C.V.s did not exceed 15% for all concentrations except at 12.5 ng/ml for EII (+)-cisapride, which was 20 and 19%, respectively. The clinical utility of the method was demonstrated in a pharmacokinetic study of normal volunteers who received a 20 mg single oral dose of racemic cisapride. The preliminary pharmacokinetic data obtained using the method we describe here provide evidence for the first time that cisapride exhibits stereoselective disposition.  相似文献   

8.
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of zolmitriptan in human plasma. After the addition of the internal standard (IS) and 1.0 M sodium hydroxide solution, plasma samples were extracted with methylene chloride:ethyl acetate mixture (20:80, v/v). The organic layer was evaporated under a stream of nitrogen at 40 degrees C. The residue was reconstituted with 100 microl mobile phase. The compounds were separated on a prepacked Lichrospher CN (5 microm, 150 mm x 2.0 mm) column using a mixture of methanol:water (10 mM NH(4)AC, pH 4.0) = 78:22 as mobile phase. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.30-16.0 ng/ml with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. The intra- and inter-day precision (R.S.D.%) were lower than 15% and accuracy ranged from 85 to 115%. The lower limit of quantification was identifiable and reproducible at 0.30 ng/ml. The proposed method enables the unambiguous identification and quantification of zolmitriptan for pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

9.
A method was developed and validated for the quantification of (±)-trans-[2-morpholino-1-(1-naphthaleneethyloxy]cyclohexane monohydrochloride (RSD1070) and its N-dealkyl metabolite in rat plasma and hepatic microsomal incubates. Chromatographic separations were achieved using reversed-phase high-performance liquid chromatography coupled with positive ion electrospray ionization and detection by tandem mass spectrometry. The assay was linear from 2.5 to 100 ng/ml and this range was used for validation. Inter- and intra-assay variability (n=6), extraction recovery, and stability in plasma were assessed. The estimated limit of quantitation was in the range 2.5–3 ng/ml for both analytes in rat plasma. The analytical method was used in a pharmacokinetic study of RSD1070 in rats after a single i.v. bolus of 12 mg/kg.  相似文献   

10.
A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of serial chiral novel anticholinergic compounds of phencynonate in rat plasma. After a simple protein-precipitation using methanol, the post-treatment samples were separated on a CAPCELL UG120 column with a mobile phase of a mixture of methanol and water (35:65) containing 0.1% formic acid. The serial chiral analytes and internal standard (IS) were all detected by the use of selected reaction monitoring mode (SRM). The method of all serial chiral analytes developed was validated in rat plasma with a daily working range of 0.5-100 ng/ml with correlation coefficient, R(2) > or = 0.99 and a sensitivity of 0.5 ng/ml as lower limit of quantification, respectively. This method was fully validated for the accuracy, precision and stability studies for all serial chiral analytes. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of serial chiral novel anticholinergic compounds of phencynonate in rat plasma.  相似文献   

11.
Helicid is a traditional Chinese medicine used to treat headache and insomnia with definite effects. To facilitate pharmacokinetic studies of helicid in man, a sensitive and specific LC-MS/MS method for the quantitative detection of helicid in human plasma was developed and validated. The method involved the addition of bergeninum as the internal standard (IS), protein precipitation, HPLC separation, and quantification by MS/MS system using negative electrospray ionization in the multiple reaction monitoring mode (MRM). The precursor→product ion transitions were monitored at m/z 282.8→120.9 for helicid and m/z 326.9→192.2 for the IS, respectively. The lower limit of quantification (LLOQ) was 0.2 μg/L. The calibration curves for helicid was linear over a concentration range of 0.2-20 μg/L. The intra- and inter-batch analyses of QC samples at 0.4, 2, 20 μg/L indicated good precision (%R.S.D. between 2.69 and 5.47%) and accuracy (between 96.15 and 105.05%). The helicid was stable in human plasma stored at room temperature for at least 24h, 4°C for at least 24h, -20°C for at least 1 month, and for routine three freeze-thaw cycles. This accurate and specific assay provides a useful method for evaluating the pharmacokinetic profile of helicid in humans.  相似文献   

12.
A fully automated column-switching high-performance liquid chromatographic (HPLC) method was developed for the quantification of finasteride [N-(1,1-dimethylethyl)-3-oxo-4-aza-5α-androst-1-ene-17β-carboxamide] in human plasma. Plasma samples were diluted with an equal volume of ethylene glycol-water (40:60, v/v), then the diluted sample (150 μl) was injected into the HPLC system without clean-up. The analyte was retained on a pretreatment column, whereas plasma proteins and other endogenous components were washed out to waste. The analyte was transferred to the analytical column in the heart-cut mode and then detected at 210 nm. A quantification limit of 1 ng/ml was attained. There was a linear relationship between peak height and drug concentration in plasma in the range 1–50 ng/ml. This method was validated and applied to the assay of plasma samples to characterize pharmacokinetic parameters in clinical studies.  相似文献   

13.
In humans, concomitant DL-methylphenidate (DL-MPH) and ethanol results in the carboxylesterase 1 (hCES1) mediated biotransformation of MPH to the transesterification metabolite DL-ethylphenidate (DL-EPH). The separate enantiomers of MPH and EPH are found at low ng/ml to pg/ml plasma concentrations. Substantial pharmacological differences exist between D- and L-isomers of MPH and EPH, both in terms of pharmacological potencies and receptor selectivity, as well as in pharmacokinetic properties. Accordingly, a sensitive, accurate and precise enantiospecific analytical method is required in order to fully explore pharmacokinetic-pharmacodynamic correlations regarding the MPH-ethanol interaction. The present study describes a novel liquid chromatographic-tandem mass spectrometric method for simultaneous analysis of D- and L-MPH as well as D- and L-EPH concentrations from human plasma. This assay provides baseline resolution of the individual MPH and EPH isomers utilizing a vancomycin-based chiral column. The lower limit of quantification was 0.025 ng/ml for each isomer when extracting 0.5 ml plasma aliquots. Calibration curves were linear over the range from 0.025 ng/ml to 25 ng/ml for all analytes (r(2)>0.995). Assay accuracy and precision were excellent and stability studies and assessment of potential matrix effects contributed to the validation of the method. Application of the method to human plasma samples collected after the administration of dl-MPH with or without ethanol is included, and the implications of this pharmacokinetic drug interaction discussed.  相似文献   

14.
A sensitive and specific method using liquid chromatography with electrospray ionization mass spectrometry (LC-ESI-MS) has been developed and validated for the identification and quantification of indapamide in human plasma. A simple liquid-liquid extraction procedure was followed by injection of the extracts on to a C18 column with gradient elution and detection using a single quadrupole mass spectrometer in selected ion monitoring (SIM) mode. The method was tested using six different plasma batches. Linearity was established for the concentration range 0.5-100.0 ng/ml, with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. The intra- and inter-day precision (RSD%) was lower than 10%, and accuracy ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.2 ng/ml with 0.2 ml plasma. The proposed method enables the unambiguous identification and quantification of indapamide for pre-clinical and clinical studies.  相似文献   

15.
A sensitive and specific liquid chromatography-tandem mass spectrometric (LC-MS-MS) method has been developed to determine m-nisoldipine in rat plasma. Sample was pretreated by a single-step protein precipitation with acetonitrile, in contrast to the liquid-liquid procedure frequently used for the extraction of 1,4-dihydropyridines from biologic samples. Separation of analyte and internal standard (I.S.) was performed on a Symmetry RP-C(18) analytic column (50 mm x 4.6 mm, 3.5 microm) with a mobile phase consisting of acetonitrile-water (80:20, v/v) at a flow rate of 0.5 ml/min. The API 4000 triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM) scan mode using TurboIonSpray ionization (ESI) source. The method was sensitive with a lower limit of quantification (LLOQ) of 0.2 ng/mL, with good linearity (r>or=0.9982) over the linear range of 0.2-20 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic and relative bioavailability studies of m-nisoldipine polymorphs in rats.  相似文献   

16.
A quantitative bioanalytical method with excellent specificity using liquid chromatography (LC) atmospheric pressure chemical ionization-tandem mass spectrometry (APCI-MS–MS) combined with a column-switching technique has been developed for the highly sensitive and reliable determination of TS-962 (HL-004), a novel acyl-CoA:cholesterol acyltransferase (ACAT) inhibitor, in rat and rabbit plasma. The method involves protein precipitation of a 25-μl aliquot of plasma sample with eight volumes of methanol containing a deuterium-labeled internal standard, the direct injection of a methanolic supernatant into the analytical instrumentation with no sample evaporation and reconstitution steps, automated on-line clean-up on a C18 short trapping column (10 mm×4.0 mm I.D.) followed by separation on a C18 analytical column (50 mm×4.6 mm I.D.), and detection with APCI-MS–MS using m/z 448 ([M+H]+) as a precursor ion and m/z 178 as a product ion in a selected reaction monitoring mode. The lower limit of quantification was 1 ng/ml, and good linearity of the calibration graph was obtained in the range of 1∼490 ng/ml with excellent reliability. The developed method enabled pharmacokinetic profiles to be determined for rats and rabbits with sequential plasma collection from an individual animal.  相似文献   

17.
Atractylenolide III is a major active component in Atractylodes macrocephala. This paper describes a simple, rapid, specific and sensitive method for the quantification of atractylenolide III in rat plasma using a liquid-liquid extraction procedure followed by liquid chromatography mass spectrometric (LC-MS) analysis. A Kromasil 3.5 microm C(18) column (150 mm x 2.00 mm) was used as the analytical column. Linear detection responses were obtained for atractylenolide III concentration ranging from 5 to 500 ng L(-1). The precision and accuracy data, based on intra-day and inter-day variations over 5 days were within 10.29%. The lower limit of quantitation for atractylenolide III was 5 ng mL(-1), using 0.1 mL plasma for extraction and its recoveries were greater than 85% at the low, medium and high concentrations. The method has been successfully applied to a pharmacokinetic study in rats after an oral administration of atractylenolide III with a dose of 20.0 mg kg(-1). With the lower limits of quantification at 5 ng mL(-1) for atractylenolide III, this method was proved to be sensitive enough for the pharmacokinetics study of atractylenolide III.  相似文献   

18.
A column-switching high-performance liquid chromatography (HPLC) method for the determination of aloesin in rat plasma using column-switching and ultraviolet (UV) absorbance detection is described. Plasma was directly injected onto the HPLC system consisting of a clean-up column, a concentrating column, and an analytical column, which were connected with a six-port switching valve. The determination of aloesin was accurate and repeatable, with a limit of quantitation of 10 ng/ml in plasma. The standard calibration curve for aloesin was linear (r=0.998) over the concentration range of 10–1000 ng/ml in rat plasma. The intra- and inter-day assay variabilities of aloesin ranged from 1.0 to 4.7% and 1.1 to 8.8%, respectively. This highly sensitive and simple method has been successfully applied to a pharmacokinetic study after oral administration of aloesin to rats.  相似文献   

19.
An analytical method based on high-performance liquid chromatography (HPLC) with ultraviolet detection (269 nm) was developed for the determination of pioglitazone in human plasma. Rosiglitazone was used as an internal standard. Chromatographic separation was achieved with a reversed-phase Apollo C18 column and a mobile phase of methanol-acetonitrile-mixed phosphate buffer (pH 2.6; 10mM) (40:12:48, v/v/v) with a flow rate of 1.2 ml/min. The calibration curve was linear over the range of 50-2000 ng/ml (r(2)>0.9987) and the lower limit of quantification was 50 ng/ml. The method was validated with excellent sensitivity, accuracy, precision, recovery and stability. The assay has been applied successfully to a pharmacokinetic study with human volunteers.  相似文献   

20.
A sensitive and specific high-performance liquid chromatographic assay with electrospray ionization mass spectrometry detection (LC-ESI-MS) has been developed and validated for the identification and quantification of the novel anticholinergic drug phencynonate in rat blood and urine. The sample pretreatment involves basification and iterative liquid-liquid extraction with ethyl ether-dichloromethane (2:1, v/v) solution, followed by LC separation and positive electrospray ionization mass spectrometry detection. The chromatography was on BetaBasic-18 column (150 mm x 2.1mm i.d., 3 microm). The mobile phase was composed of methanol-water (85:15, v/v), containing 0.5 per thousand formic acid, which was pumped at a flow-rate of 0.2 ml/min. Thiencynonate was selected as the internal standard (IS). Simultaneous MS detection of phencynonate and IS was performed at m/z 358.4 (phencynonate), m/z 364 (thiencynonate), and the selected reaction ion monitoring (SRM) of the two compounds was at 156. Phencynonate eluted at approximately 5.25 min, thiencynonate eluted at approximately 5.10 min and no endogenous materials interfered with their measurement. Linearity was obtained over the concentration range of 1-100 ng/ml in rat blood and 1-500 ng/ml in rat urine. The lower limit of quantification (LLOQ) was reproducible at 1 ng/ml in both of rat blood and urine. The precision measured was obtained from 2.92 to 9.76% in rat blood and 4.17 to 9.76% in rat urine. Extraction recoveries were in the range of 69.57-79.49% in blood and 56.85-64.86% in urine. This method was successfully applied to the identification and quantification of phencynonate in pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号