首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fecal culture for Escherichia coli O157:H7 was compared to rectoanal mucosal swab (RAMS) culture in dairy heifers over a 1-year period. RAMS enrichment culture was as sensitive as fecal culture using immunomagnetic separation (IMS) (P = 0.98, as determined by a chi-square test). RAMS culture is less costly than fecal IMS culture and can yield quantitative data.  相似文献   

2.
We compared fecal samples with samples collected with rectoanal mucosa swabs (RAMS) to determine the prevalence of Escherichia coli O157 in feedlot cattle (n = 747). Escherichia coli O157 was detected in 9.5% of samples collected with RAMS and 4.7% of samples tested by fecal culture. Pulsed-field gel electrophoresis analysis of isolates suggested that the strains colonizing the rectoanal junction were the same as those from the feces. Mucosal swab sampling was more sensitive than fecal sampling for determining the prevalence of E.coli O157 in feedlot cattle.  相似文献   

3.
The distribution of Escherichia coli O157 in bovine feces was examined by testing multiple samples from fecal pats and determining the density of E. coli O157 in immunomagnetic separation (IMS)-positive fecal samples. The density of E. coli O157 in bovine feces was highly variable, differing by as much as 76,800 CFU g−1 between samples from the same fecal pat. The density in most positive samples was <100 CFU g−1, the limit of reliable detection by IMS. Testing only one 1-g sample of feces per pat with IMS may result in a sensitivity of detection as low as 20 to 50%. It is therefore probable that most surveys have greatly underestimated the prevalence of E. coli O157 shedding in cattle and the proportion of farms with shedding cattle. The sensitivity of the detection of E. coli O157 in bovine feces can be as much as doubled by testing two 1-g samples per pat rather than one 1-g sample.  相似文献   

4.
We compared fecal samples with samples collected with rectoanal mucosa swabs (RAMS) to determine the prevalence of Escherichia coli O157 in feedlot cattle (n = 747). Escherichia coli O157 was detected in 9.5% of samples collected with RAMS and 4.7% of samples tested by fecal culture. Pulsed-field gel electrophoresis analysis of isolates suggested that the strains colonizing the rectoanal junction were the same as those from the feces. Mucosal swab sampling was more sensitive than fecal sampling for determining the prevalence of E. coli O157 in feedlot cattle.  相似文献   

5.
The Register of Antarctic Marine Species (RAMS) is a marine species database that manages an authoritative taxonomic list of species occurring in the Southern Ocean. RAMS links with several other initiatives managing biogeographic or genomics information. The current paper aims to briefly present RAMS and provides an updated snapshot of its contents, in the form of a DarwinCore checklist (available through http://ipt.biodiversity.aq/resource.do?r=rams) and illustrative barplots. Moreover, this article presents a ten year appraisal (since the creation of RAMS). This appraisal first focuses on RAMS bibliometrics. We observed that RAMS was cited (Google Scholar) in 50 distinct publications among which 32 were peer-reviewed in 18 different journals. Three journals (Antarctic Science, Polar Biology, ZooKeys) represent almost 40% of these peer-review publications. The second appraisal focuses on the evolution of new RAMS records. We observed an important decrease in data additions since 2011. As a case study, we focused on an original dataset for a specific group (Asteroidea, Echinodermata). It appears that around one hundred species of asteroids are lacking in RAMS despite the relatively high availability of these data. This suggests that the users’ community (or collaborative projects such as AquaRES) could be helpful in order to maintain the RAMS database over the long term.  相似文献   

6.
A direct immunofluorescence assay (DFA) (Merifluor; Meridian Diagnostics, Inc., Cincinnati, Ohio) was compared to an immunomagnetic separation (IMS) assay (Dynabeads; Dynal, Inc., Lake Success, N.Y.) coupled with immunofluorescent microscopy (Waterborne, Inc., New Orleans, La.) for their ability to detect low concentrations of Cryptosporidium parvum oocysts in adult bovine fecal material. IMS-DFA resulted in a 2-log-unit increase in sensitivity (10 oocysts/g) compared to DFA alone (1,000 oocysts/g). The higher sensitivity obtained with IMS-DFA resulted from testing 2 g of fecal material instead of the 13 to 19 mg of fecal material tested in the DFA; the increased sensitivity was not attributable to a higher percent recovery.  相似文献   

7.
A commercial enzyme immunoassay (EIA) (E. coli O157 Visual Immunoassay; Tecra Diagnostics) performed on enrichment cultures in modified Escherichia coli broth (mECn) was compared with immunomagnetic separation (IMS) (Dynabeads anti-E. coli O157; Dynal) performed on enrichment cultures in modified buffered peptone water (BPW-VCC) for the detection of E. coli O157 in bovine fecal samples. Tests on fecal suspensions inoculated with each of 12 different strains of E. coli O157 showed that both the EIA and IMS methods were 10- to 100-fold more sensitive than direct culture or enrichment subculture methods for detection of the organism. EIA and IMS were then compared for detection of E. coli O157 in bovine rectal swabs. For confirmation of positive EIA tests, a commercial system (Immunocapture System [ICS]; Tecra Diagnostics) was compared with IMS; both were performed on mECn enrichment cultures. Of 200 rectal swabs examined, 17 gave positive results in the EIA which were confirmed by both confirmation systems, 2 gave positive results in the EIA which were confirmed by IMS but not by ICS, and 1 gave a positive result in the EIA which was confirmed by ICS but not by IMS. Of these 20, 15 were also positive by the BPW-VCC-IMS culture system; a further 3 samples were positive by this culture system but gave a negative result in the EIA. Eight samples were negative by the BPW-VCC-IMS culture system but gave a positive result in the EIA which could not be confirmed by either confirmation system. Further examination of the eight unconfirmed EIA-positive samples yielded sorbitol-fermenting E. coli O157 from three samples. Of the remaining five cultures, four were positive in an EIA for verocytotoxins (VT) and two were positive in a cell culture assay for VT1. The remaining 170 samples were negative by both EIA and BPW-VCC-IMS. The Tecra EIA and IMS are both technically simple and sensitive methods for detecting E. coli O157 in bovine fecal samples. There was no statistically significant difference between the numbers of positives detected by the different assays (P = 0.29).  相似文献   

8.
The results of this study support the use of fecal Bacteroidales qPCR as a rapid method to complement traditional, culture-dependent, water quality indicators in systems where drinking water is supplied without chlorination or other forms of disinfection. A SYBR-green based, quantitative PCR assay was developed to determine the concentration of fecal Bacteroidales 16S rRNA gene copies. The persistence of a Bacteroides vulgatus pure culture and fecal Bacteroidales from a wastewater inoculum was determined in unchlorinated drinking water at 10 °C. B. vulgatus 16S rRNA gene copies persisted throughout the experimental period (200 days) in sterile drinking water but decayed faster in natural drinking water, indicating that the natural microbiota accelerated decay. In a simulated fecal contamination of unchlorinated drinking water, the decay of fecal Bacteroidales 16S rRNA gene copies was considerably faster than the pure culture but similar to that of Escherichia coli from the same wastewater inoculum.  相似文献   

9.
Immunomagnetic separation (IMS) can selectively isolate and concentrate Mycobacterium bovis cells from lymph node tissue to facilitate subsequent detection by PCR (IMS-PCR) or culture (IMS-MGIT). This study describes application of these novel IMS-based methods to test for M. bovis in a survey of 280 bovine lymph nodes (206 visibly lesioned (VL), 74 non-visibly lesioned (NVL)) collected at slaughter as part of the Northern Ireland bovine TB eradication programme. Their performance was evaluated relative to culture. Overall, 174 (62.1%) lymph node samples tested positive by culture, 162 (57.8%) by IMS-PCR (targeting IS6110), and 191 (68.2%) by IMS-MGIT culture. Twelve (6.9%) of the 174 culture positive lymph node samples were not detected by either of the IMS-based methods. However, an additional 79 M. bovis positive lymph node samples (27 (13.1%) VL and 52 (70.3%) NVL) were detected by the IMS-based methods and not by culture. When low numbers of viable M. bovis are present in lymph nodes (e.g. in NVLs of skin test reactor cattle) decontamination prior to culture may adversely affect viability, leading to false negative culture results. In contrast, IMS specifically captures whole M. bovis cells (live, dead or potentially dormant) which are not subject to any deleterious treatment before detection by PCR or MGIT culture. During this study only 2.7% of NVL lymph nodes tested culture positive, whereas 70.3% of the same samples tested M. bovis positive by the IMS-based tests. Results clearly demonstrate that not only are the IMS-based methods more rapid but they have greater detection sensitivity than the culture approach currently used for the detection of M. bovis infection in cattle. Adoption of the IMS-based methods for lymph node testing would have the potential to improve M. bovis detection in clinical samples.  相似文献   

10.
The distribution of Escherichia coli O157 in bovine feces was examined by testing multiple samples from fecal pats and determining the density of E. coli O157 in immunomagnetic separation (IMS)-positive fecal samples. The density of E. coli O157 in bovine feces was highly variable, differing by as much as 76,800 CFU g(-1) between samples from the same fecal pat. The density in most positive samples was <100 CFU g(-1), the limit of reliable detection by IMS. Testing only one 1-g sample of feces per pat with IMS may result in a sensitivity of detection as low as 20 to 50%. It is therefore probable that most surveys have greatly underestimated the prevalence of E. coli O157 shedding in cattle and the proportion of farms with shedding cattle. The sensitivity of the detection of E. coli O157 in bovine feces can be as much as doubled by testing two 1-g samples per pat rather than one 1-g sample.  相似文献   

11.
Yersinia enterocolitica is considered an important food-borne pathogen impacting the pork production and processing industry in the United States. Since this bacterium is a commensal of swine, the primary goal of this study was to determine the prevalence of pathogenic Y. enterocolitica in pigs in the United Sates using feces as the sample source. A total of 2,793 fecal samples were tested for its presence in swine. Fecal samples were collected from late finisher pigs from 77 production sites in the 15 eastern and midwestern pork-producing states over a period of 27 weeks (6 September 2000 to 20 March 2001). The prevalence of ail-positive Y. enterocolitica was determined in samples using both a fluorogenic 5′ nuclease PCR assay and a culture method. The mean prevalence was 13.10% (366 of 2,793 fecal samples tested) when both PCR- and culture-positive results were combined. Forty-one of 77 premises (53.25%) contained at least one fecal sample positive for the ail sequence. The PCR assay indicated a contamination rate of 12.35% (345/2,793) compared to 4.08% (114/2,793) by the culture method. Of the 345 PCR-positive samples, 252 were culture negative, while of the 114 culture-positive samples, 21 were PCR negative. Among 77 premises, the PCR assay revealed a significantly (P < 0.05) higher percentage (46.75%, n = 36 sites) of samples positive for the pathogen (ail sequence) than the culture method (22.08%, n = 17 sites). Thus, higher sensitivity, with respect to number of samples and sites identified as positive for the PCR method compared with the culture method for detecting pathogenic Y. enterocolitica, was demonstrated in this study. The results support the hypothesis that swine are a reservoir for Y. enterocolitica strains potentially pathogenic for humans.  相似文献   

12.
Aims: Legionella isolation from environmental samples is often difficult because of the presence of heterotrophic‐associated bacteria that frequently overgrow when using standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods. To improve Legionella pneumophila recovery from complex water samples (water from cooling towers, biofilms), we evaluated an immunomagnetic separation (IMS) assay using a monoclonal antibody raised against the lipopolysaccharide of Leg. pneumophila sg1 in combination with culture. Methods and Results: This study was conducted on 51 environmental specimens. The comparison between IMS‐culture and standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods was made using ISO 17994, 2004 criteria for establishing equivalence between microbiological methods based on the upper and lower (XH and XL) values of the relative difference (95% confidence limit) and D as maximum acceptable deviation (value of the confidence limit). Conclusions: We found that the average performance of IMS culture was higher than the reference method. Significance and Impact of the Study: Thus, this IMS‐culture assay is particularly well adapted to the detection of Leg. pneumophila sg1 in environmental samples with high levels of interfering microflora.  相似文献   

13.
Urinary tract infection (UTI) is a common disease with significant morbidity and economic burden, accounting for a significant part of the workload in clinical microbiology laboratories. Current clinical chemisty point-of-care diagnostics rely on imperfect dipstick analysis which only provides indirect and insensitive evidence of urinary bacterial pathogens. An electronic nose (eNose) is a handheld device mimicking mammalian olfaction that potentially offers affordable and rapid analysis of samples without preparation at athmospheric pressure. In this study we demonstrate the applicability of ion mobility spectrometry (IMS) –based eNose to discriminate the most common UTI pathogens from gaseous headspace of culture plates rapidly and without sample preparation. We gathered a total of 101 culture samples containing four most common UTI bacteries: E. coli, S. saprophyticus, E. faecalis, Klebsiella spp and sterile culture plates. The samples were analyzed using ChemPro 100i device, consisting of IMS cell and six semiconductor sensors. Data analysis was conducted by linear discriminant analysis (LDA) and logistic regression (LR). The results were validated by leave-one-out and 5-fold cross validation analysis. In discrimination of sterile and bacterial samples sensitivity of 95% and specificity of 97% were achieved. The bacterial species were identified with sensitivity of 95% and specificity of 96% using eNose as compared to urine bacterial cultures. In conclusion: These findings strongly demonstrate the ability of our eNose to discriminate bacterial cultures and provides a proof of principle to use this method in urinanalysis of UTI.  相似文献   

14.
In a double-blind prospective study including 114 healthy young volunteers, the presence in human feces of the yogurt organisms Lactobacillus delbrueckii and Streptococcus thermophilus after repeated yogurt consumption (15 days) was analyzed by culture, specific PCR, and DNA hybridization of total fecal DNA. Detection of yogurt lactic acid bacteria in total fecal DNA by bacterial culture and PCR assay was consistently negative. DNA compatible with yogurt bacteria was found by hybridization experiments in only 10 (10.52%) of 96 individuals after consumption of fresh yogurt and in 2 (2.10%) of 96 individuals after consumption of pasteurized yogurt (P = 0.01).  相似文献   

15.
Denaturing gradient gel electrophoresis (DGGE) of DNA fragments generated by PCR with 16S ribosomal DNA-targeted group-specific primers was used to detect lactic acid bacteria (LAB) of the genera Lactobacillus, Pediococcus, Leuconostoc, and Weissella in human feces. Analysis of fecal samples of four subjects revealed individual profiles of DNA fragments originating not only from species that have been described as intestinal inhabitants but also from characteristically food-associated bacteria such as Lactobacillus sakei, Lactobacillus curvatus, Leuconostoc mesenteroides, and Pediococcus pentosaceus. Comparison of PCR-DGGE results with those of bacteriological culture showed that the food-associated species could not be cultured from the fecal samples by plating on Rogosa agar. On the other hand, all of the LAB species cultured from feces were detected in the DGGE profile. We also detected changes in the types of LAB present in human feces during consumption of a milk product containing the probiotic strain Lactobacillus rhamnosus DR20. The analysis of fecal samples from two subjects taken before, during, and after administration of the probiotic revealed that L. rhamnosus was detectable by PCR-DGGE during the test period in the feces of both subjects, whereas it was detectable by culture in only one of the subjects.  相似文献   

16.
The Verigene Clostridium difficile Nucleic Acid Test (Verigene CDF Test) (Nanosphere, Northbrook, IL, USA) is a new multiplex qualitative polymerase chain reaction (PCR) test used to detect C. difficile toxin genes in fecal specimens. To evaluate the performance of the new method, we tested 69 fecal samples from patients with suspected C. difficile infection using the Verigene CDF test, an enzyme immunoassay (EIA) and PCR following anaerobic fecal culture. The sensitivity, specificity, and accuracy of the Verigene CDF test were 96.7% (29/30), 97.4% (38/39), and 97.1% (67/69) respectively, using PCR following fecal culture as a reference method. We also analyzed the potential clinical impact of the Verigene CDF test using chart reviews of the 69 patients with suspected C. difficile infection and found that 11 of the 69 patients were incorrectly diagnosed, and the Verigene CDF test would have led to them receiving more appropriate management including practice of treatment and contact precaution, although, of the 69 patients, there are two whose samples were incorrectly identified with the Verigene CDF test. The Verigene CDF test will have a positive impact on patient care.  相似文献   

17.
In 2010, Romaine lettuce grown in southern Arizona was implicated in a multi-state outbreak of Escherichia coli O145:H28 infections. This was the first known Shiga toxin-producing E. coli (STEC) outbreak traced to the southwest desert leafy green vegetable production region along the United States-Mexico border. Limited information exists on sources of STEC and other enteric zoonotic pathogens in domestic and wild animals in this region. According to local vegetable growers, unleashed or stray domestic dogs and free-roaming coyotes are a significant problem due to intrusions into their crop fields. During the 2010–2011 leafy greens growing season, we conducted a prevalence survey of STEC and Salmonella presence in stray dog and coyote feces. Fresh fecal samples from impounded dogs and coyotes from lands near produce fields were collected and cultured using extended enrichment and serogroup-specific immunomagnetic separation (IMS) followed by serotyping, pulsed-field gel electrophoresis (PFGE), and antimicrobial susceptibility testing. A total of 461 fecal samples were analyzed including 358 domestic dog and 103 coyote fecals. STEC was not detected, but atypical enteropathogenic E. coli (aEPEC) strains comprising 14 different serotypes were isolated from 13 (3.6%) dog and 5 (4.9%) coyote samples. Salmonella was cultured from 33 (9.2%) dog and 33 (32%) coyote samples comprising 29 serovars with 58% from dogs belonging to Senftenberg or Typhimurium. PFGE analysis revealed 17 aEPEC and 27 Salmonella distinct pulsotypes. Four (22.2%) of 18 aEPEC and 4 (6.1%) of 66 Salmonella isolates were resistant to two or more antibiotic classes. Our findings suggest that stray dogs and coyotes in the desert southwest may not be significant sources of STEC, but are potential reservoirs of other pathogenic E. coli and Salmonella. These results underscore the importance of good agriculture practices relating to mitigation of microbial risks from animal fecal deposits in the produce production area.  相似文献   

18.
Culture-based methods to detect the six major non-O157 (O26, O45, O103, O111, O121 and O145) Shiga toxin-producing E. coli (STEC) are not well established. Our objectives of this study were to develop a culture-based method to detect the six non-O157 serogroups in cattle feces and compare the detection with a PCR method. Fecal samples (n = 576) were collected in a feedlot from 24 pens during a 12-week period and enriched in E. coli broth at 40° C for 6 h. Enriched samples were subjected to immunomagnetic separation, spread-plated onto a selective chromogenic medium, and initially pooled colonies, and subsequently, single colonies were tested by a multiplex PCR targeting six serogroups and four virulence genes, stx1, stx2, eae, and ehxA (culture method). Fecal suspensions, before and after enrichment, were also tested by a multiplex PCR targeting six serogroups and four virulence genes (PCR method). There was no difference in the proportions of fecal samples that tested positive (74.3 vs. 77.4%) for one or more of the six serogroups by either culture or the PCR method. However, each method detected one or more of the six serogroups in samples that were negative by the other method. Both culture method and PCR indicated that O26, O45, and O103 were the dominant serogroups. Higher proportions (P < 0.05) of fecal samples were positive for O26 (44.4 vs. 22.7%) and O121 (22.9 vs. 2.3%) serogroups by PCR than by the culture method. None of the fecal samples contained more than four serogroups. Only a small proportion of the six serogroups (23/640; 3.6%) isolated carried Shiga toxin genes. The culture method and the PCR method detected all six serogroups in samples negative by the other method, highlighting the importance of subjecting fecal samples to both methods for accurate detection of the six non-O157 STEC in cattle feces.  相似文献   

19.

Background

Intermediate syndrome (IMS) is a major cause of death from respiratory failure following acute organophosphate poisoning. The objective of this study was to determine repetitive nerve stimulation (RNS) predictors of IMS that would assist in patient management and clinical research.

Methods and Findings

Seventy-eight consenting symptomatic patients with organophosphate poisoning were assessed prospectively with daily physical examination and RNS. RNS was done on the right and left median and ulnar nerves at 1, 3, 10, 15, 20, and 30 Hz. The study was conducted as a prospective observational cohort study in the Central Province, Sri Lanka. IMS was diagnosed in ten out of 78 patients using a priori clinical diagnostic criteria, and five of them developed respiratory failure. All ten patients showed progressive RNS changes correlating with the severity of IMS. A decrement-increment was observed at intermediate and high frequencies preceding the onset of clinical signs of IMS. As the patient developed clinical signs of IMS, decrement-increment was progressively noted at low and intermediate frequencies and a combination of decrement-increment and repetitive fade or severe decrement was noted at high frequencies. Severe decrement preceded respiratory failure in four patients. Thirty patients developed forme fruste IMS with less severe weakness not progressing to respiratory failure whose RNS was characterized by decrement-increment or a combination of decrement-increment and repetitive fade but never severe decrements.

Conclusions

Characteristic changes in RNS, preceding the development of IMS, help to identify a subgroup of patients at high risk of developing respiratory failure. The forme fruste IMS with the characteristic early changes on RNS indicates that IMS is a spectrum disorder. RNS changes are objective and precede the diagnosis and complications of IMS. Thus they may be useful in clinical management and research.  相似文献   

20.
An immunomagnetic separation (IMS) technique was developed to facilitate selective isolation of Mycobacterium paratuberculosis cells from milk. Rabbit polyclonal antibodies against radiation-killed intact M. paratuberculosis cells were produced and used to coat sheep anti-rabbit immunoglobulin G (IgG) type M-280 Dynabeads. The rabbit anti-M. paratuberculosis IgG-coated beads (IMB) reacted strongly with laboratory strains of M. paratuberculosis as determined by slide agglutination, and microscopic examination confirmed that M. paratuberculosis cells attached to the IMB. The IMB were found to have a maximum binding capacity of 104 to 105 CFU of M. paratuberculosis. Studies showed that IMS selectively recovered M. paratuberculosis from inoculated milk containing as few as 10 CFU of M. paratuberculosis per ml when 10 μl of IMB (ca. 106 beads) was added to 1 ml of milk and the preparation was incubated for 30 min at room temperature with gentle agitation. Larger volumes of milk (10 and 50 ml) were centrifuged and resuspended in 1 ml of phosphate-buffered saline–0.05% Tween 20 prior to IMS in order to increase the sensitivity of the method. Currently, primary isolation of M. paratuberculosis from a milk sample relies on chemical decontamination, followed by culturing on Herrold’s egg yolk medium, which must be incubated at 37°C for up to 18 weeks. The potential value of our IMS method is as an aid for rapid detection of M. paratuberculosis in milk when it is used in conjunction with end point detection methods, such as IS900 PCR or an enzyme-linked immunosorbent assay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号