首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method has been developed for the determination of trenbolone in bovine urine and serum. The aim was a control of the misuse of trenbolone in food-producing animals. The procedure involved, in both cases, a preliminary solid-phase clean-up followed by a liquid-liquid extraction for urine samples after a preliminary enzymatic hydrolysis. The extracts have been directly analysed by reversed-phase LC-MS-MS in selected reaction monitoring (SRM), acquiring two diagnostic product ions from the chosen precursor [M+H](+). The procedures were validated across the concentration range of 1-1500 ng/ml. The linearity, the inter- and intra-day accuracy and precision have been determined. The procedure was specific and the accuracy values were better than 20% at the limit of quantitation of spiked samples. The limit of quantification (LOQ) and the limit of detection (LOD) were, respectively, 1 ng/ml and 350 pg/ml for urine and serum. According to the draft, SANCO/1805/2000, we determined the decision limit CCalpha and the detection capability CCbeta. The recovery values for urine ranged from 87 to 128%, and for plasma the recovery was 70+/-4%. The procedure proved to be simple and suitable for routine and confirmatory purposes such as those developed for residue studies.  相似文献   

2.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

3.
A simple method using liquid chromatography-linear ion trap mass spectrometry for simultaneous determination of testosterone glucuronide (TG), testosterone sulfate (TS), epitestosterone glucuronide (EG) and epitestosterone sulfate (ES) in urine samples was developed. For validation purposes, a urine containing no detectable amount of TG, TS and EG was selected and fortified with steroid conjugate standards. Quantification was performed using deuterated testosterone conjugates to correct for ion suppression/enhancement during ESI. Assay validation was performed in terms of lower limit of detection (1-3ng/mL), recovery (89-101%), intraday precision (2.0-6.8%), interday precision (3.4-9.6%) and accuracy (101-103%). Application of the method to short-term stability testing of urine samples at temperature ranging from 4 to 37 degrees C during a time-storage of a week lead to the conclusion that addition of sodium azide (10mg/mL) is required for preservation of the analytes.  相似文献   

4.
The novel compound methyl-1-(3,4-dimethoxyphenyl)-3-(3-ethylvaleryl)-4-hydroxy-6,7,8-trimethoxy-2-naphthoate (S-8921) has hypocholesterolemic activity in animals and is expected to exhibit a similar activity in human. Reversed-phase high-performance liquid chromatography (HPLC) separation followed by radioimmunoassay (RIA) for human plasma samples (HPLC–RIA) and immunoaffinity extraction (IAE) followed by RIA for human urine samples (IAE–RIA) were developed for investigation of S-8921 behavior in clinical studies. For the RIA, antisera from rabbit and a radioiodine-labelled S-8921 were prepared by immunizing a conjugate of S-8921 with bovine serum albumin and by the Bolton and Hunter method, respectively. HPLC–RIA using a semi-micro column was very sensitive, that is a 0.05 ng/ml limit of quantitation in human plasma, and specific for unchanged form of S-8921. IAE–RIA using a centrifugal filtration tube completely eliminated the matrix effect of human urine, and was very feasible. The limit of quantitation was 0.10 ng/ml. RIA detection following HPLC or IAE proved to be very useful for the pharmaceutical analysis of extremely low drug concentrations in body fluids.  相似文献   

5.
Morphine is present in varying amounts as an endogenous product in human urine. Derivatization of morphine contained in urine with dansyl chloride yields a known product, which can be quantified by liquid chromatography mass spectrometry with high selectivity and sensitivity. Urine samples of 51 healthy individuals were spiked with stable-isotope labeled morphine, hydrolyzed and subjected to solid phase extraction followed by derivatization of morphine with dansyl chloride. The dansyl derivatives of naturally occurring morphine and deuterated internal standard were then detected by liquid chromatography-triple quadrupole mass spectrometry. Using the [N-CD(3)]-labeled internal standard and solid-phase extraction, a limit of detection of 35 fmol/ml (10 pg/ml) and a limit of quantification of 87.5 fmol/ml (25 pg/ml) was determined for morphine in human urine. This new LC-MS/MS method allowed the detection of endogenous morphine in human urine of 51 volunteers with an average value of 156.4 fmol/ml (44.7 ng/ml).  相似文献   

6.
A very sensitive enzymeimmunoassay for testosterone was developed using testosterone-penicillinase conjugate and an antibody to testosterone-3-(O-carboxymethyl)oxime-bovine serum albumin. The specificity of the assay was demonstrated by the fact that estradiol-17 beta, estrone, estriol, progesterone, 17 alpha-hydroxy-progesterone, dehydroepiandrosterone, androstenedione, cortisol and cortisone were ineffective in crossreacting with testosterone while dihydrotestosterone was 8 times less crossreactive as compared to testosterone. The minimum detectable amount of testosterone was 10-15 pg per assay tube. Intra-assay and inter-assay coefficients of variation for samples containing 0.3-6ng/ml of testosterone were 6-8% and 8-10%, respectively. A high degree of correlation (r = 0.97) was observed between serum testosterone values obtained by enzymeimmunoassay and radioimmunoassay. The levels of testosterone in the sera of normal men and women and those in hypogonadal males following stimulation with human chorionic gonadotropin determined by this enzymeimmunoassay appear similar to those reported by other investigators.  相似文献   

7.
We have developed a sensitive and selective radioimmunoassay for porcine/human endothelin (ET1). The assay has a detection limit of 0.62 pg/tube and exhibits no cross-reactivity to atrial natriuretic peptide, arginine vasopressin, or angiotensin II. Procedures were developed for extraction of endothelin from human plasma samples and samples of buffer from endothelial cell incubations using C18 Sep-Pak extraction cartridges. The mean recovery following extraction was approximately 80%. Both bovine and porcine aortic endothelial cells were found to produce immunoreactive endothelin (IR-ET) with porcine cells producing 4.7 +/- 1.1 ng of IR-ET/mg cell protein after 6 hours. Human plasma samples were extracted, assayed and found to contain a mean concentration of 2.0 +/- 0.4 pg/ml of IR-ET.  相似文献   

8.
An amperometric immunosensor in the competitive format was developed for the detection of methamphetamine in urine. The electrodes consisted of carbon paste and Ag/AgCl screen printed on heat sealing film, respectively, and of monoclonal anti-methamphetamine antibody as the biorecognition element. Optimum amounts of methamphetamine- N -bovine serum albumin conjugate, monoclonal antibody and alkaline phosphatase-goat anti-mouse immunoglobulin G were 20, 10 ng and 1:10,000 dilution in 10 μl each, respectively. Methamphetamine was detected by the conversion of p -aminophenyl phosphate to electroactive p -aminophenol in the range of 200 ng/ml (lower detection limit) to 1,500 ng/ml methamphetamine in a nearly linear dose response curve. Within amphetamine concentrations of 0-1,500 ng/ml cross-reaction with methamphetamine was not observed. Working with urine samples spiked with methamphetamine, the accuracy and precision of the assay were 91.5-104.4% and 15.8-24.4%, respectively. This is a proof of concept in the clinical perspective for an amperometric immunosensor whose electrodes are amenable to future mass production.  相似文献   

9.
A novel water-compatible macroporous molecularly imprinted film (MIF) has been developed for rapid, sensitive, and label-free detection of small molecule testosterone in urine. The MIF was synthesized by photo copolymerization of monomers (methacrylic acid [MAA] and 2-hydroxyethyl methacrylate [HEMA]), cross-linker (ethylene glycol dimethacrylate, EGDMA), and polystyrene nanoparticles (PS NPs) in combination with template testosterone molecules. The PS NPs and template molecules were subsequently removed to form an MIF with macroporous structures and the specific recognition sites of testosterone. Incubation of artificial urine and human urine on the MIF and the non-imprinted film (NIF), respectively, indicated undetectable nonspecific adsorption. Accordingly, the MIF was applied on a surface plasmon resonance (SPR) sensor for the detection of testosterone in phosphate-buffered saline (PBS) and artificial urine with a limit of detection (LOD) down to 10−15 g/ml. To the best of our knowledge, the LOD is considered as one of the lowest among the SPR sensors for the detection of small molecules. The control experiments performed with analogue molecules such as progesterone and estradiol demonstrated the good selectivity of this MIF for sensing testosterone. Furthermore, this MIF-based SPR sensor shows high stability and reproducibility over 8 months of storage at room temperature, which is more robust than protein-based biosensors.  相似文献   

10.
Because 17β-19-nortestosterone and its esters are frequently used anabolic steroids in cattle in Europe, there is a need for an assay that can also detect certain metabolites. The enzyme immunoassay described here involves the detection and quantitation of the major metabolite 17α-19-nortestosterone in urine. The assay is based on the coating of an antibody raised in a rabbit against 17α-19-nortestosterone-3-carboxy-methyloxime—bovine serum albumin (17α-19-NT-3-CMO-BSA), the competitive incubation of 17α-19-NT and the 17α-19-nortestosterone-3-CMO—horseradish peroxidase label, followed by the detection of the blue colour developed by the action of the enzyme on tetramethylbenzidine. The 3-CMO conjugate of 17α-19-nortestosterone was used to produce an antibody with selective affinity for the 17α-epimer. For the optimization of the assay, different coatings and incubation conditions were tested. The standard curve ranged between 0.98 and 4000 pg per well, with a B/B0 50% of ± 65 pg per well. Colour was measured with a microtitre plate reader. The method was validated by means of certified blank and spiked cattle urine samples.  相似文献   

11.
Polyclonal antibodies were produced for the development of competitive ELISA's and surface plasmon resonance (SPR)-based BIAcore inhibition assays for the detection of morphine-3-glucuronide (M3G, the main metabolite of heroin and morphine). A conjugate consisting of M3G and ovalbumin was produced and used for the generation of antibodies, for the coating of immunoplates and for immobilisation onto BIAcore chips. Competition ELISA's were developed in PBS and urine to characterise the antibodies ability to recognise free M3G. SPR-based inhibition immunoassays on BIAcore were developed. The regeneration of the surface of a chip immobilised with conjugate following antibody binding, essential for the development of inhibition assays was investigated. Regeneration of the conjugate-coated surface was optimised for both polyclonal antibodies resulting in binding-regeneration capacities of approximately 60 cycles for one antibody and 50 cycles for the second antibody. The inhibition assays developed in urine had ranges of detection of 762-24,400 (antibody 1) and 976-62,500 pg ml(-1) (antibody 2). The inter-day coefficients of variation for the assays ranged from 1.48 to 11.24%.  相似文献   

12.
In modern biomedical technology, development of high performance sensing methods for dopamine (DA) is a critical issue because of its vital role in human metabolism. We report here, a new kind of bioaffinity sensor for DA based on surface plasmon resonance (SPR) using a D(3) dopamine receptor (DA-RC) as a recognition element. A conjugate of DA was synthesized using bovine serum albumin (BSA) protein and was characterized by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The biosensor surface was constructed by the immobilization of the DA-BSA conjugate onto an SPR gold surface by physical adsorption. Atomic force microscopy (AFM) investigations revealed that the DA-BSA conjugate was homogeneously distributed over the sensor surface. Specific interaction of the DA-RC with the immobilized DA-BSA conjugate was studied by SPR. Based on the principle of indirect competitive inhibition, the biosensor could detect DA in a linear dynamic range from 85 pg/ml (ppt) to 700 ng/ml (ppb). The biosensor was highly specific for DA and showed no significant interference from potent interferences such as ascorbic acid (AA), uric acid (UA) and other DA analogues viz., 3,4 dihydroxyphenyl acetic acid (DOPAC) and 3-(3,4 dihydroxyphenyl)-alanine (DOPA). The sensor surface displayed a high level of stability during repeated regeneration and affinity reaction cycles. Since this biosensor is simple, effective and is based on utilization of natural receptor, our study presents an encouraging scope for development of portable detection systems for in-vitro and in-vivo measurement of DA in clinical and medical diagnostics.  相似文献   

13.
An amperometric immunosensor in the competitive format was developed for the detection of methamphetamine in urine. The electrodes consisted of carbon paste and Ag/AgCl screen printed on heat sealing film, respectively, and of monoclonal anti-methamphetamine antibody as the biorecognition element. Optimum amounts of methamphetamine- N -bovine serum albumin conjugate, monoclonal antibody and alkaline phosphatase-goat anti-mouse immunoglobulin G were 20, 10 ng and 1:10,000 dilution in 10 &#119 l each, respectively. Methamphetamine was detected by the conversion of p -aminophenyl phosphate to electroactive p -aminophenol in the range of 200 ng/ml (lower detection limit) to 1,500 ng/ml methamphetamine in a nearly linear dose response curve. Within amphetamine concentrations of 0-1,500 ng/ml cross-reaction with methamphetamine was not observed. Working with urine samples spiked with methamphetamine, the accuracy and precision of the assay were 91.5-104.4% and 15.8-24.4%, respectively. This is a proof of concept in the clinical perspective for an amperometric immunosensor whose electrodes are amenable to future mass production.  相似文献   

14.
Aflatoxin is a liver carcinogen, and rapid, inexpensive methods to detect its urinary biomarkers are needed. We used a commercial enzyme-linked immuno-sorbent assay (ELISA) for aflatoxin M1 in urine (Helica Biosystems) to test 52 Haitian samples. Using this ELISA, we detected traces above the limit of detection (0.2?ng/ml urine) but below the limit of quantitation (0.4?ng/ml) in 14 samples. Liquid chromatography of all 52 Haitian urine samples revealed that only 11 had quantifiable AFM1 (mean: 29.5?pg/ml, standard error: 10.8, range: 2.94–96.5?pg/ml). The Helica ELISA may have detected forms of aflatoxin other than AFM1 in the Haitian samples, or matrix enhancement may have affected results at low AFM1 concentrations. This ELISA may serve as an initial, qualitative indicator of aflatoxin exposure for epidemiological purposes. But this method’s utility as a precise and specific indicator of AFM1 concentrations will require additional refinement and validation.  相似文献   

15.
A method for the determination of melatonin in human saliva has been developed using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS). Saliva was collected in plastic tubes. 7-D-Melatonin was added as internal standard and the samples were cleaned and concentrated by solid-phase extraction. The limit of detection was 1.05 pg x ml(-1) and the limit of quantification was 3.0 pg x ml(-1). The accuracy of the method was +/-14% at 5.60 pg x ml(-1) and +/-9% at 19.6 pg x ml(-1). The precision was +/-13% at 6.18 pg x ml(-1) and +/-11% at 31.2 pg x ml(-1), respectively. Our HPLC-MS-MS method shows a high sensitivity and specificity for melatonin and more reliable results compared with a radioimmunoassay. The chromatographic method has been used to determine the circadian rhythm of melatonin among three nurses working the night shift and a patient suffering from an inability to fall asleep at night.  相似文献   

16.
A gas chromatographic–mass spectrometric method was developed for the determination of residues of clenbuterol in bovine urine. The method involves a simple cation-exchange clean-up and concentration of clenbuterol in the acidified urine, followed by ethyl acetate extraction. The analyte is determined as the di-trimethylsilyl derivative and quantitated against an internal standard of penbutolol. Using a 5-ml sample of urine, a detection limit of 0.07 ng/ml can be achieved with recoveries close to 100% for fortification levels of 0.2 and 1 ng/ml. By increasing the sample volume to 50 ml, a detection limit below 0.01 ng/ml was achievable with recovery averaging 70%. The coefficient of variation of the assay ranged from 15% at 0.01 ng/ml (50-ml sample) to 6% at 1 ng/ml (5-ml sample). It was demonstrated that the method can detect the presence of clenbuterol in bovine urine at sub-ppb (ng/ml) levels using low resolution GC–MS with electron impact (EI) ionization.  相似文献   

17.
Antiserum against PGE2 was raised in rabbits following immunization with prostaglandin-hen-gamma-globulin conjugate. The antiserum exhibited 14% cross reactivity with PGE1 and far less cross-reaction with heterologous prostaglandins. A microcolumn of Sephadex LH-20 was used for a partial, but sufficient separation of PGE2 from PGE1 and a complete separation from heterologous prostaglandins to ensure a specific RIA for PGE2. The precision of the method in the rage 10-500 picograms showed a coefficient of variation varying between 4 and 13%. The detection limit was 10 picograms corresponding to 15 pg/ml of PGE2 in serum. In order to demonstrate the validity of the method values obtained for non-diuretic rat renal venous serum were compared with those obtained using the isotope derivative method of Bojesen & Buckhave (1972) on the same samples. The concentrations of PGE2 obtained were 239 +/- 25 pg/ml and 250 +/- 58 pg/ml, respectively.  相似文献   

18.
A Fiber-Optic Localized Surface Plasmon Resonance (FO LSPR) sensor was fabricated using spherical gold nanoparticles (Au NPs) on a flattened end-face of the optical fiber. The Au NPs were easily synthesized by the Turkevich method and were immobilized on the end-face of the optical fiber by using a self-assembled monolayer (SAM). In order to examine the possibility of its application as a biosensor for label-free immunoassays, the fabricated FO LSPR sensor was used for the detection of the antibody-antigen reaction of interferon-gamma (IFN-γ) and the limit of detection (LOD) was approximately 2pg/ml. Herein, The antibodies and bovine serum albumins (BSAs) were immobilized on the Au NPs by physisorption. Also, the FO LSPR sensor was used for the detection of a prostate-specific antigen (PSA) and the LOD was 1pg/ml below. The fabricated FO LSPR sensor can be used for real-time label-free immunoassay having fast detection time, high resolution and sensitivity. In addition, the proposed sensor platform has the advantages of low cost, simple optical setup, remote sensing, simple fabrication, real-time detection, low sample volume, and potential application to in-vivo detection systems.  相似文献   

19.
The present work reports capillary liquid chromatographic column switching methodology tailored for fast, sensitive and selective determination of 1-hydroxypyrene (1-OHP) in human urine using micro-electrospray ionization time-of-flight mass spectrometric detection. Samples (100 microl) of deconjugated, water diluted and filtered urine samples were loaded onto a 150 microm I.D.x 30 mm 10 microm Kromasil C(18) pre-column, providing on-line sample clean-up and analyte enrichment, prior to back flushed elution onto a 150 microm I.D.x 100 mm 3.5 microm Kromasil C(18) analytical column. Loading flow rates up to 100 microl/min in addition to the use of isocratic elution by a mobile phase composition of acetonitrile/water (70/30, v/v) containing 5 mM ammonium acetate provided elution of 1-OHP within 5.5 min and a total analysis time of less than 15 min with manual operation. Ionization was performed in the negative mode and 1-OHP was observed as [M-H](-) at m/z 217.08. The method was validated over the concentration range 0.2-40 ng/ml 1-OHP in pre-treated urine, yielding a coefficient of correlation of 0.997. The within-assay (n=6) and between-assay (n=6) precisions were in the range 6.4-7.3 and 7.0-8.1%, respectively, and the recoveries were in the range 96.2-97.5 within the investigated concentration range. The method mass limit of detection was 2 pg, corresponding to a 1-OHP concentration limit of detection of 20 pg/ml (0.09 nmol/l) diluted urine or 0.3 ng/ml (1.35 nmol/l) urine.  相似文献   

20.
A new competitive immunostrip assay was developed to detect human serum albumin (HSA) in urine sample with use of conjugated monoclonal antibody gold nanoparticles (mAb–AuNPs) and mobile crystalline material (MCM)-41–HSA bioconjugate. To prepare the immunostrip, the colloidal AuNPs with an average particle diameter of 20 nm, was synthesized, labeled with antibody and applied on the conjugate pad as the detection reagent. Then, HSA was attached to the MCM-41 mesoporous nanoparticles and immobilized to a nitrocellulose membrane as the test line. In the optimized investigational conditions, the immunostrip could detect HSA in a high linear range (from 1 to 200 μg/ml) and low detection limit (ng/ml). The reliability of the testing procedure was examined by performing the immunostrip test with 30 urine samples and comparing the results with those obtained via immunoturbidimetry. The immunostrip was adequately sensitive and accurate for a rapid screening of HSA in the urine. This new strategy for competitive immunostrip design can be used and developed for other antigen based immunostrip assay.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号