首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 16 毫秒
1.
A reversed-phase, C-18 HPLC method for separation, with baseline resolution, of the chitin synthase inhibitors nikkomycin X and Z is described. This permits, for the first time, satisfactory identification of nikkomycin X and Z contained in a mixture. The use of 30 mM ammonium formate (pH 4.7) containing the ion-pair agent heptanesulfonic acid (1 mM) was critical for the successful separation of these fungicides.  相似文献   

2.

Background  

Nikkomycins are a group of peptidyl nucleoside antibiotics and act as potent inhibitors of chitin synthases in fungi and insects. Nikkomycin X and Z are the main components produced by Streptomyces ansochromogenes. Of them, nikkomycin Z is a promising antifungal agent with clinical significance. Since highly structural similarities between nikkomycin Z and X, separation of nikkomycin Z from the culture medium of S. ansochromogenes is difficult. Thus, generating a nikkomycin Z selectively producing strain is vital to scale up the nikkomycin Z yields for clinical trials.  相似文献   

3.
In addition to most chlorophylls and their derivatives, monovinyl and divinyl chlorophyll species were separated by high-performance liquid chromatography, using a polyethylene column and a simple elution with aqueous acetone. Peak retention and resolution of the pigment separation were greatly increased by increasing the polarity of the mobile phase and also by decreasing the column temperature. Polyethylene chromatography showed chlorophyll separation behavior similar to that of the octadecyl silica column, but it showed no adsorption of the pigment species containing free carboxylic acid groups, enabling the complete separation of chlorophylls and their derivatives. Polyethylene is a superior alternative stationary phase to the known reversed-phase materials for chlorophyll separation and analysis.  相似文献   

4.
Methodology, based on reversed-phase high-performance liquid chromatography, is described for monitoring the reactions of cisplatin with DNA, nucleotides, and methionine. Cisplatin was determined in DNA ultrafiltrates on solvent-generated anion exchangers which were prepared by coating the surface of a reversed-phase column with hexadecyltrimethylammonium bromide. These systems were also applicable to studies on the reactions of cisplatin with nucleotides. The retention of the nucleotides studied (5'-AMP, 5'-GMP, 5'-CMP, and 5'-TMP) was described by means of an ion-exchange model and was manipulated by controlling the phosphate concentration in the mobile phase and its pH. The results indicate that cisplatin interacts predominantly with adenosine and guanosine groups on the DNA molecule and that binding is limited by the rate of conversion to an aquated intermediate. Whereas reversed-phase HPLC systems employing cationic pairing ions were applicable to the analysis of mixtures containing cisplatin and anionic solutes, systems employing alkyl sulfonates were required to monitor the reaction of cisplatin with methionine which produces cationic products. Retention, in this latter system, was optimized by the addition of acetonitrile to the mobile phase and by controlling the concentration and chain length of alkylsulfonate in the mobile phase. Although an octadecylsilylsilica, reversed-phase column was preferred for the analytical separation of the methionine-platinum complexes, a polystyrene-divinylbenzene colume was preferred for preparative work.  相似文献   

5.
In former studies, dinucleoside polyphosphates were quantified using ion-pair reversed-phase perfusion chromatography columns, which allows a detection limit in the micromolar range. The aim of this study was both to describe a chromatographic assay with an increased efficiency of the dinucleoside separation, which enables the reduction of analytical run times, and to establish a chromatographic assay using conditions, which allow MALDI-mass spectrometric analysis of the resulting fractions. We compared the performance of conventional silica reversed phase chromatography columns, a perfusion chromatography column and a monolithic reversed-phase C18 chromatography column. The effects of different ion-pair reagents, flow-rates and gradients on the separation of synthetic diadenosine polyphosphates as well as of diadenosine polyphosphates isolated from human platelets were analysed. Sensitivity and resolution of the monolithic reversed-phase chromatography column were both higher than that of the perfusion chromatography and the conventional reversed phase chromatography columns. Using a monolithic reversed-phase C18 chromatography column, diadenosine polyphosphates were separable baseline not only in the presence of tetrabutylammonium hydrogensulfate (TBA) but also in the presence of triethylammonium acetate (TEAA) as ion-pair reagent. The later reagent is useful because, in contrast to TBA, it is compatible with MALDI mass-spectrometric methods. This makes TEAA particularly suitable for identification of unknown nucleoside polyphosphates. Furthermore, because of the lower backpressure of monolithic reversed-phase chromatography columns, we were able to significantly increase the flow rate, decreasing the amount of time for the analysis close to 50%, especially using TBA as ion-pair reagent. In summary, monolithic reversed phase C18 columns markedly increase the sensitivity and resolution of dinucleoside polyphosphate analysis in a time-efficient manner compared to reversed-phase perfusion chromatography columns or conventional reversed-phase columns. Therefore, further dinucleoside polyphosphate analytic assays should be based on monolithic silica C18 columns instead of perfusion chromatography or conventional silica reversed phase chromatography columns. In conclusion, the use of monolithic silica C18 columns will lead to isolation and quantification of up to now unknown dinucleoside polyphosphates. These chromatography columns may facilitate further research on the biological roles of dinucleoside polyphosphates.  相似文献   

6.
目的:用RP-HPLC方法对注射用重组人尿激酶原制剂蛋白含量进行定量分析。方法:用反相C18柱、0.1%TFA水溶液与0.1%乙腈进行梯度洗脱,280nm波长紫外检测器监测;以重组人尿激酶原同质标准品作为对照品,根据进样量和相应的峰面积建立标准曲线方程,将待测定样品的峰面积代入标准曲线方程,可测得蛋白含量。结果:按照方法学验证要求对此方法进行了专属性、检测限、定量限、线形、精密度(重复性、中间精密度)、准确度(回收率)考察,线性范围为9~27μg,回收率在97%以上,RSD2.0%,完全满足对制剂蛋白的定量需求。结论:本方法准确,适用于注射用重组人尿激酶原成品制剂蛋白定量测定。  相似文献   

7.
Pre-column derivatization of amikacin with 1-fluoro-2,4-dinitrobenzene in 25 μl of guinea pig plasma or human serum produced a stable chromophore which was measured by UV detection after rapid separation on normal-phase or reversed-phase high-performance liquid chromatography systems. The reversed-phase system, selected for routine analysis due to instability of the normal-phase column, consisted of an Ultrasphere-ODS C18 column preceded by a guard column, and used acetonitrile—water (68:32) as the mobile phase. A high degree of linearity was found in the range of 2—64 μg/ml with a coefficient of variation averaging less than 5%.  相似文献   

8.
A new postcolumn derivatization system using 1,2-naphthoquinone-4-sulfonate as fluorogenic reagent for the fluorometric determination of guanidino compounds is described. The guanidino compounds were separated by reversed-phase ion-pair high-performance liquid chromatography with an isocratic mobile phase containing the fluorogenic reagent and octane-sulfonate as the counterion. Fluorophors were derived from a condensation of guanidino compounds with the fluorogenic reagent in an alkaline solution. The chromatographic system using the mobile phase containing the fluorogenic reagent was simplified because only two pumps were required to deliver the mobile phase and the alkaline solution. Separation of guanidino compounds was completed within 25 min using a Nucleosil C8 column (5 microns, 15 cm X 4.6 mm i.d.). This method was applied to serum obtained from patients on hemodialysis therapy.  相似文献   

9.
The chiral separation of norgestrel enantiomers using reversed-phase high-performance liquid chromatography (RP-HPLC) was studied with hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral mobile phase additive. The effect of mobile phase composition, concentration of HP-beta-CD and column temperature on enantioselective separation were investigated. The quantification properties of the developed RP-HPLC method were examined. A baseline separation of norgestrel enantiomers was achieved on a Agilent ZORBAX Eclipse XDB-C8 column (150 mm x 4.6 mm i.d., 5 microm). The mobile phase was a mixture of acetonitrile and phosphate buffer (pH 5.0, 20 mM) containing 25 mM HP-beta-CD (30:70, v/v) with a flow rate of 1.0 ml/min. The UV detector was set at 240 nm. Calibration curves were linear (n=8) in the range of 0.2-25 microg/ml, the limit of detection and quantitation were 0.10 and 0.20 microg/ml, respectively, for racemic norgestrel. The values of RSD of repeatability and intermediate precision for spiked sample were less than 4.8%. The method was successfully applied to the enantioselective determination of this drug in stereoselective skin permeation study.  相似文献   

10.
A rapid, sensitive method using liquid chromatography–electrospray mass spectrometry (LC–ES-MS) was developed and evaluated for the simultaneous quantitative determination of caffeine metabolites 1U, 1X and AAMU in human urine. This method involved a simple dilution of urine samples. The chromatographic separation was achieved on a C18 reversed-phase column using a gradient of acetonitrile in 2 mM, pH 3.0 ammonium formate as mobile phase. After ionisation in an electrospray source, mass spectrometric detection was performed in the negative ion, selected ion monitoring mode. This method yielded acceptable accuracy and precision within the range 0.25–50 μg/ml. This analytical method was applied to investigate the N-acetylator phenotype of HIV-infected patients and compared with high-performance liquid chromatography with UV detection. Its specificity was better, which appeared to be absolutely necessary to prevent errors in metabolic ratios and phenotype interpretation.  相似文献   

11.
A sensitive and reproducible high-performance liquid chromatography (HPLC)-UV method for the determination of Z24, a tumorigenesis and angiogenesis inhibitor, has been developed and validated in mouse whole blood. Blood samples were extracted with ether, evaporated, and the residue was reconstituted in mobile phase. An aliquot was separated by isocratic reversed-phase HPLC on a Hypersil ODS-2 column and quantified using UV detection at 390nm. The mobile phase was 50% (v/v) acetonitrile/water with a flow rate of 0.8ml/min. A linear curve over the concentration range of 0.05-6mug/ml (r(2)=0.9976) was obtained. The coefficient of the variation for the intra- and inter-day precision ranged from 3.0 to 10.9% and 5.7 to 10.3%, respectively. The absolute recovery of Z24 was 89.2-108.5%. The method is simple, economical and sufficient for in vivo pharmacokinetic studies on Z24. Nonlinear pharmacokinetics was found in mice at doses from 20 to 80mg/kg.  相似文献   

12.
A genomic library from Streptomyces tendae raised in shuttle cosmid vector pKC505 was screened with a previously isolated 8-kb DNA fragment containing the orfP1 gene, which is involved in nikkomycin biosynthesis. The entire set of structural genes for nikkomycin synthesis was heterologously expressed in S. lividans TK23 by introducing recombinant cosmids p24/32 and p9/43-2, carrying inserts of about 31 and 27 kb, respectively, overlapping by 15 kb. S. lividans transformants synthesized nikkomycins X, Z, I, and J, which were identified by high-pressure liquid chromatography analyses of culture filtrates.  相似文献   

13.
P M Young  T E Wheat 《BioTechniques》1991,10(2):228-235
The standard method for separating peptide mixtures is reversed-phase high-performance liquid chromatography with gradients of increasing concentrations of acetonitrile in the presence of trifluoroacetic acid. With modern instruments and columns, complex peptide mixtures can be separated, and low picomole amounts can be collected in tens of microliters. Difficult separations are addressed by modifying the gradient slope or organic eluant composition. Further improvements in resolution are often needed, requiring fundamental changes in mobile phase composition or selection of complementary chromatographic separation mechanisms. For the present study, tryptic digests of cytochrome c from various species were separated in the presence of dilute hydrochloric acid by reversed phase on a Waters Delta-PakTM C18 high-performance insert column and by strong cation exchange on a Waters Protein-PakTM SP 8HR. Different and enhanced reversed-phase selectivity was obtained by replacing trifluoroacetic acid with dilute hydrochloric acid at the same pH. The increased optical clarity of hydrochloric acid-based mobile phases in the low ultraviolet wavelengths yielded increased sensitivity. Very different selectivity was observed with the cation-exchange chromatography. These data expand the options for peptide mapping by providing additional selectivity combined with increased mass sensitivity and spectral information in the low ultraviolet.  相似文献   

14.
尼可霉素是一种新的抗真菌抗生素,在分离到的20多种活性单组分中,X、Z、I、J为主要生物活性组分。本文介绍了尼可霉素的结构,结构与活性的关系及其生物合成途径中有关基因的研究进展。  相似文献   

15.
A method is described for the determination of urinary hippuric acid by high-performance liquid chromatography. The method used ethyl acetate extraction for partial clean-up of the urine. The separation was carried out on a reversed-phase column using 20% methanol in 0.01 M aqueous potassium phosphate containing 0.5% acetic acid as a mobile phase. The column effluent was monitored with a UV detector at 254 nm. Hippuric acid was separated from other normal urine constituents in less than 10 min. Metabolites of xylene and styrene did not interfere with the assay. Analytical recoveries from urine were excellent and peak height and concentration were linearly related.  相似文献   

16.
The simultaneous determination of trimethoprim, sulphamethoxazole and N4-acetyl-sulphamethoxazole in serum and urine by high-performance liquid chromatography using sulphafurazole as internal standard is described. The separation was achieved on a reversed-phase column employing acetic acid—methanol as the mobile phase with spectrophotometric detection at 230 nm. Precise simultaneous quantitative analysis of the relative components has been achieved at levels of 0.1 μg/ml for trimethoprim and 1.0 μg/ml for both sulphamethoxazole and its N4-acetyl metabolize using 1 ml of serum or urine.  相似文献   

17.
A micro-scale method for separation and measurement of dityrosine in human cerebrospinal fluid (CSF) is described utilizing liquid-liquid extraction and ion-paired, reversed-phase high-performance liquid chromatography with fluorimetric detection. A mobile phase containing 1-heptanesulfonic acid linearly increased in methanol from 0 to 100% over 30 min allows the resolution of dityrosine from other fluorescent compounds with excitation at 285 nm and emission at 410 nm. As little as 0.15 ml CSF sample can be utilized with a detection limit of 60 pg dityrosine on the column. This method facilitates the use of CSF dityrosine as a measure of free radical mediated protein damage in the central nervous system.  相似文献   

18.
建立了反相高效液相色谱法(RP-HPLC)分离肝源性磷脂酰胆碱(PC)分子种的有效方法。考察了流动相中有机溶剂的种类、配比及流速对分离肝源性PC的影响。研究发现,在以甲醇为主的流动相中加入正己烷和醋酸铵有利于肝源性PC分子种的分离;甲醇-乙腈-水梯度洗脱不适于分离肝源性PC分子种。结果表明,采用Kromasil C18色谱柱(4.6 mm×200 mm,5μm),以甲醇-正己烷-0.05 mol/L醋酸铵-甘油(84∶6∶8∶0.6,体积比)为流动相,在流速1.0 mL/min、检测波长206 nm、柱温35℃的条件下,实现了肝源性PC各组分的分离。所建立的方法灵敏,重复性高,为进一步采用液质联用技术研究肝源性PC不同分子种的结构奠定基础。  相似文献   

19.
A high-performance, reversed-phase liquid chromatographic (HPLC) procedure has been developed for the separation of at least three major bilirubin fractions in bile and four fractions in human serum. This procedure was unlike most others, in that serum was not totally deproteinized prior to injection onto the HPLC column; instead, serum was treated with an excess of sodium sulfate solution to precipitate primarily proteins larger than albumin. Injection of the filtered and diluted supernatant onto a reversed-phase column then resulted in the separation of the bilirubin species in a 24-min gradient elution run. Both the initial aqueous acidic mobile phase and the final isopropyl alcohol-based mobile phase contained 5% methoxyethanol (v/v) to facilitate elution of albumin still present in the treated sample. Bilirubin species eluting from the column were detected by absorbance at 450 nm.Results of a number of chromatographic separations of pathological sera indicated a wide variation in the relative proportions of the four bilirubin fractions observed. A correlation of the sum of the areas of the bilirubin peaks observed by HPLC was found with the total bilirubin value obtained by a standard reference procedure.  相似文献   

20.
Xie Z  Niu G  Li R  Liu G  Tan H 《Current microbiology》2007,55(6):537-542
Nikkomycins are highly potent inhibitors of chitin synthase. The nikkomycin biosynthetic gene cluster has been cloned from Streptomyces asochromogenes. Two cytochrome P450 monooxygenase genes (sanQ, sanH) and one ferredoxin gene (sanI) were found in the cluster. It was reported that SanQ is involved in the hydroxylation of l-His, a key step in 4-formyl-4-imidazolin-2-one base biosynthesis. Here, we have studied the function of sanH and sanI. Disruption of sanH abolished the production of nikkomycin X and Z, but it accumulated one dominant component nikkomycin Lx, which is the nikkomycin X analog lacking the hydroxy group at the pyridyl residue. The sanI disruption mutant accumulated predominantly nikkomycin Lx in addition to nikkomycin X and Z. The nikkomycin production profile of the sanH and sanI double disruption mutant was the same as that of the sanH disruption mutant. These results confirmed that SanH is essential for the hydroxylation of pyridyl residue in nikkomycin biosynthesis of S. ansochromogenes and first demonstrated that SanI is an effective electron donor for SanH, but not for SanQ in vivo.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏