首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe a new fluorescence imaging methodology in which the image contrast is derived from the fluorescence lifetime at each point in a two-dimensional image and not the local concentration and/or intensity of the fluorophore. In the present apparatus, lifetime images are created from a series of images obtained with a gain-modulated image intensifier. The frequency of gain modulation is at the light-modulation frequency (or a harmonic thereof), resulting in homodyne phase-sensitive images. These stationary phase-sensitive images are collected using a slow-scan CCD camera. A series of such images, obtained with various phase shifts of the gain-modulation signal, is used to determine the phase angle and/or modulation of the emission at each pixel, which is in essence the phase or modulation lifetime image. An advantage of this method is that pixel-to-pixel scanning is not required to obtain the images, as the information from all pixels is obtained at the same time. The method has been experimentally verified by creating lifetime images of standard fluorophores with known lifetimes, ranging from 1 to 10 ns. As an example of biochemical imaging we created life-time images of Yt-base when quenched by acrylamide, as a model for a fluorophore in distinct environments that affect its decay time. Additionally, we describe a faster imaging procedure that allows images in which a specific decay time is suppressed to be calculated, allowing rapid visualization of unique features and/or regions with distinct decay times. The concepts and methodologies of fluorescence lifetime imaging (FLIM) have numerous potential applications in the biosciences. Fluorescence lifetimes are known to be sensitive to numerous chemical and physical factors such as pH, oxygen, temperature, cations, polarity, and binding to macromolecules. Hence the FLIM method allows chemical or physical imaging of macroscopic and microscopic samples.  相似文献   

2.
Several fluorescent probes have been used in the past to monitor and to measure intracellular calcium and calcium fluxes. The most widely used of these probes are those developed by Tsien. We address the markedly different values obtained when comparing Quin-2 (the original probe) with Fura-2 (a second-generation probe). In most cases the values for intracellular calcium have been considered to be interchangeable for the different probes. Using several different hematopoietic cell lines we show that in no case do the two probes yield equivalent values.  相似文献   

3.
C Y Dong  P T So  T French    E Gratton 《Biophysical journal》1995,69(6):2234-2242
We report the development of a scanning lifetime fluorescence microscope using the asynchronous, pump-probe (stimulated emission) approach. There are two significant advantages of this technique. First, the cross-correlation signal produced by overlapping the pump and probe lasers results in i) an axial sectioning effect similar to that in confocal and two-photon excitation microscopy, and ii) improved spatial resolution compared to conventional one-photon fluorescence microscopy. Second, the low-frequency, cross-correlation signal generated allows lifetime-resolved imaging without using fast photodetectors. The data presented here include 1) determination of laser sources' threshold powers for linearity in the pump-probe signal; 2) characterization of the pump-probe intensity profile using 0.28 microns fluorescent latex spheres; 3) high frequency (up to 6.7 GHz) lifetime measurement of rhodamine B in water; and 4) lifetime-resolved images of fluorescent latex spheres, human erythrocytes and a mouse fibroblast cell stained by rhodamine DHPE, and a mouse fibroblast labeled with ethidium bromide and rhodamine DHPE.  相似文献   

4.
We report a highly specific fluorescence lifetime imaging microscopy (FLIM) method for monitoring epidermal growth factor receptor (EGFR) phosphorylation in cells based on fluorescence resonance energy transfer (FRET). EGFR phosphorylation was monitored using a green fluorescent protein (GFP)-tagged EGFR and Cy3-conjugated anti-phosphotyrosine antibodies. In this FRET-based imaging method, the information about phosphorylation is contained only in the (donor) GFP fluorescence lifetime and is independent of the antibody-derived (acceptor) fluorescence signal. A pixel-by-pixel reference lifetime of the donor GFP in the absence of FRET was acquired from the same cell after photobleaching of the acceptor. We show that this calibration, by acceptor photobleaching, works for the GFP-Cy3 donor-acceptor pair and allows the full quantitation of FRET efficiencies, and therefore the degree of exposed phosphotyrosines, at each pixel. The hallmark of EGFR stimulation is receptor dimerisation [1] [2] [3] [4] and concomitant activation of its intracellular tyrosine kinase domain [5] [6] [7]. Trans-autophosphorylation of the receptor [8] [9] on specific tyrosine residues couples the activated dimer to the intracellular signal transduction machinery as these phosphorylated residues serve as docking sites for adaptor and effector molecules containing Src homology 2 (SH2; reviewed in [10]) and phosphotyrosine-binding (PTB) [11] domains. The time-course and extent of EGFR phosphorylation are therefore important determinants of the underlying pathway and resulting cellular response. Our results strongly suggest that secondary proteins are recruited by activated receptors in endosomes, indicating that these are active compartments in signal transduction.  相似文献   

5.
The steady improvement in the imaging of cellular processes in living tissue over the last 10–15 years through the use of various fluorophores including organic dyes, fluorescent proteins and quantum dots, has made observing biological events common practice. Advances in imaging and recording technology have made it possible to exploit a fluorophore's fluorescence lifetime. The fluorescence lifetime is an intrinsic parameter that is unique for each fluorophore, and that is highly sensitive to its immediate environment and/or the photophysical coupling to other fluorophores by the phenomenon Förster resonance energy transfer (FRET). The fluorescence lifetime has become an important tool in the construction of optical bioassays for various cellular activities and reactions. The measurement of the fluorescence lifetime is possible in two formats; time domain or frequency domain, each with their own advantages. Fluorescence lifetime imaging applications have now progressed to a state where, besides their utility in cell biological research, they can be employed as clinical diagnostic tools. This review highlights the multitude of fluorophores, techniques and clinical applications that make use of fluorescence lifetime imaging microscopy (FLIM).  相似文献   

6.
In this article, a fluorescence lifetime imaging system for small animals is presented. Data were collected by scanning a region of interest with a measurement head, a linear fiber array with fixed separations between a single source fiber and several detection fibers. The goal was to localize tumors and monitor their progression using specific fluorescent markers. We chose a near-infrared contrast agent, Alexa Fluor 750 (Invitrogen Corp., Carlsbad, CA). Preliminary results show that the fluorescence lifetime for this dye was sensitive to the immediate environment of the fluorophore (in particular, pH), making it a promising candidate for reporting physiologic changes around a fluorophore. To quantify the intrinsic lifetime of deeply embedded fluorophores, we performed phantom experiments to investigate the contribution of photon migration effects on observed lifetime by calculating the fluorescence intensity decay time. A previously proposed theoretical model of migration, based on random walk theory, is also substantiated by new experimental data. The developed experimental system has been used for in vivo mouse imaging with Alexa Fluor 750 contrast agent conjugated to tumor-specific antibodies (trastuzumab [Herceptin]). Three-dimensional mapping of the fluorescence lifetime indicates lower lifetime values in superficial breast cancer tumors in mice.  相似文献   

7.
8.
Summary Using the fluorescent calcium probe Quin-2, we could demonstrate a tip-to-base gradient of free calcium within growing pollen tubes ofLilium longiflorum. This result shows that it is possible to visualize calcium ions using Quin-2 in plant cells which are surrounded by a cell wall and that the calcium gradients demonstrated by CTC fluorescence (indicating membrane-bound calcium) and PIXE (showing total calcium) is paralleled by a gradient of free calcium in pollen tubes.  相似文献   

9.
Fluorescence lifetime distributions in proteins.   总被引:10,自引:7,他引:3       下载免费PDF全文
The fluorescence lifetime value of tryptophan residues varies by more than a factor of 100 in different proteins and is determined by several factors, which include solvent exposure and interactions with other elements of the protein matrix. Because of the variety of different elements that can alter the lifetime value and the sensitivity to the particular environment of the tryptophan residue, it is likely that non-unique lifetime values result in protein systems. The emission decay of most proteins can be satisfactorily described only using several exponential components. Here it is proposed that continuous lifetime distributions can better represent the observed decay. An approach based on protein dynamics is presented, which provides fluorescence lifetime distribution functions for single tryptophan residue proteins. First, lifetime distributions for proteins interconverting between two conformations, each characterized by a different lifetime value, are derived. The evolution of the lifetime values as a function of the interconversion rate is studied. In this case lifetime distributions can be obtained from a distribution of rates of interconversion between the two conformations. Second, the existence of a continuum of energy substates within a given conformation was considered. The occupation of a particular energy substate at a given temperature is proportional to the Boltzmann factor. The density of energy states of the potential well depends upon the width of the well, which determines the degree of freedom the residue can move in the conformational space. Lifetime distributions can be obtained by association of each energy substate with a different lifetime value and assuming that the average conformation can change as the energy of the substate is increased.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
We investigated the use of fluorescence lifetime imaging microscopy (FLIM) of a fluorescently labeled ATP analog (3'-O-{N-[3-(7-diethylaminocoumarin-3-carboxamido)propyl]carbamoyl}ATP) to probe in permeabilized muscle fibers the changes in the environment of the nucleotide binding pocket caused by interaction with actin. Spatial averaging of FLIM data of muscle sarcomeres reduces photon noise, permitting detailed analysis of the fluorescence decay profiles. FLIM reveals that the lifetime of the nucleotide, in its ADP form because of the low concentration of nucleotide present, changes depending on whether the nucleotide is free in solution or bound to myosin, and on whether the myosin is bound to actin in an actomyosin complex. Characterization of the fluorescence decays by a multiexponential function allowed us to resolve the lifetimes and amplitudes of each of these populations, namely, the fluorophore bound to myosin, bound to actin, in an actomyosin complex, and free in the filament lattice. This novel application of FLIM to muscle fibers shows that with spatial averaging, detailed information about the nature of nucleotide complexes can be derived.  相似文献   

11.
The sodium-potassium ATPase (Na/K-ATPase, NKA) establishes ion gradients that facilitate many physiological functions including action potentials and secondary transport processes. NKA comprises a catalytic subunit (alpha) that interacts closely with an essential subunit (beta) and regulatory transmembrane micropeptides called FXYD proteins. In the heart, a key modulatory partner is the FXYD protein phospholemman (PLM, FXYD1), but the stoichiometry of the alpha–beta–PLM regulatory complex is unknown. Here, we used fluorescence lifetime imaging and spectroscopy to investigate the structure, stoichiometry, and affinity of the NKA-regulatory complex. We observed a concentration-dependent binding of the subunits of NKA–PLM regulatory complex, with avid association of the alpha subunit with the essential beta subunit as well as lower affinity alpha–alpha and alpha–PLM interactions. These data provide the first evidence that, in intact live cells, the regulatory complex is composed of two alpha subunits associated with two beta subunits, decorated with two PLM regulatory subunits. Docking and molecular dynamics (MD) simulations generated a structural model of the complex that is consistent with our experimental observations. We propose that alpha–alpha subunit interactions support conformational coupling of the catalytic subunits, which may enhance NKA turnover rate. These observations provide insight into the pathophysiology of heart failure, wherein low NKA expression may be insufficient to support formation of the complete regulatory complex with the stoichiometry (alpha-beta-PLM)2.  相似文献   

12.
The structures and functions of the cellular acidic compartments are strongly dependent on the pH gradients across vesicular membranes. Measurement and imaging of the vesicular pH require fluorophores with appropriate pK(a) values. In this report, we characterized the pH-dependent lifetime responses of a family of acidotropic probes, LysoSensors, to evaluate their usefulness to low-pH lifetime imaging. LysoSensors are cell-permeable weak bases that selectively accumulate in acidic vesicles after being protonated. They have higher quantum yields at lower pH ranges to allow visualization of the lysosomes. For LysoSensors DND-167, DND-189, and DND-153, raising the buffer pH increased the quenching effects of their basic side chains and substantially reduced their steady-state fluorescence and lifetimes. The apparent pK(a) values determined from their lifetime responses were shifted to near neutral values because of the dominant intensity contribution from their protonated species. One unique property of LysoSensor DND-189 is its nonmonotonic lifetime responses of the maxima occurring between pH 4 and 5. LysoSensor DND-192 did not show significant lifetime changes over a wide pH range. LysoSensor DND-160, which was the only excitation and emission ratiometric probe, showed significant pH-dependent lifetime changes as well as its spectral shifts. Its apparent pK(a) values determined from the lifetime responses were comparable to the lysosomal pH because of its bright basic form. Because of the pH-dependent absorption spectra, the apparent pK(a) values could be manipulated between 3 and 5 by changing the excitation and/or emission wavelengths. These results indicate that LysoSensor DND-160 is a promising probe for lifetime imaging to determine lysosomal pH.  相似文献   

13.
Chlamydia trachomatis is an obligate intracellular bacterium that alternates between two metabolically different developmental forms. We performed fluorescence lifetime imaging (FLIM) of the metabolic coenzymes, reduced nicotinamide adenine dinucleotides [NAD(P)H], by two-photon microscopy for separate analysis of host and pathogen metabolism during intracellular chlamydial infections. NAD(P)H autofluorescence was detected inside the chlamydial inclusion and showed enhanced signal intensity on the inclusion membrane as demonstrated by the co-localization with the 14-3-3β host cell protein. An increase of the fluorescence lifetime of protein-bound NAD(P)H [τ2-NAD(P)H] inside the chlamydial inclusion strongly correlated with enhanced metabolic activity of chlamydial reticulate bodies during the mid-phase of infection. Inhibition of host cell metabolism that resulted in aberrant intracellular chlamydial inclusion morphology completely abrogated the τ2-NAD(P)H increase inside the chlamydial inclusion. τ2-NAD(P)H also decreased inside chlamydial inclusions when the cells were treated with IFNγ reflecting the reduced metabolism of persistent chlamydiae. Furthermore, a significant increase in τ2-NAD(P)H and a decrease in the relative amount of free NAD(P)H inside the host cell nucleus indicated cellular starvation during intracellular chlamydial infection. Using FLIM analysis by two-photon microscopy we could visualize for the first time metabolic pathogen-host interactions during intracellular Chlamydia trachomatis infections with high spatial and temporal resolution in living cells. Our findings suggest that intracellular chlamydial metabolism is directly linked to cellular NAD(P)H signaling pathways that are involved in host cell survival and longevity.  相似文献   

14.
15.
Fluorescence lifetime imaging microscopy (FLIM) is a quantitative microscopy technique for imaging nanosecond decay times of fluorophores. In the case of frequency-domain FLIM, several methods have been described to resolve the relative abundance of two fluorescent species with different fluorescence decay times. Thus far, single-frequency FLIM methods generally have been limited to quantifying two species with monoexponential decay. However, multiexponential decays are the norm rather than the exception, especially for fluorescent proteins and biological samples. Here, we describe a novel method for determining the fractional contribution in each pixel of an image of a sample containing two (multiexponentially) decaying species using single-frequency FLIM. We demonstrate that this technique allows the unmixing of binary mixtures of two spectrally identical cyan or green fluorescent proteins, each with multiexponential decay. Furthermore, because of their spectral identity, quantitative images of the relative molecular abundance of these fluorescent proteins can be generated that are independent of the microscope light path. The method is rigorously tested using samples of known composition and applied to live cell microscopy using cells expressing multiple (multiexponentially decaying) fluorescent proteins.  相似文献   

16.
Murata S  Herman P  Lin HJ  Lakowicz JR 《Cytometry》2000,41(3):178-185
BACKGROUND: DNA fluorescence dyes have been used to study DNA dynamics, chromatin structure, and cell cycle analysis. However, most microscopic fluorescence studies of DNA use only steady-state measurements and do not take advantage of the additional information content of the time-resolved fluorescence. In this paper, we combine fluorescence imaging of DNA with time-resolved measurements to examine the proximity of donors and acceptors bound to chromatin. METHODS: We used frequency-domain fluorescence lifetime imaging microscopy to study the spatial distribution of DNA-bound donors and acceptors in fixed 3T3 nuclei. Over 50 cell nuclei were imaged in the presence of an AT-specific donor, Hoechst 33258 (Ho), and a GC-specific acceptor, 7-aminoactinomycin D (7-AAD). RESULTS: The intensity images of Ho alone showed a spatially irregular distribution due to the various concentrations of DNA or AT-rich DNA throughout the nuclei. The lifetime imaging of the Ho-stained nuclei was typically flat. Addition of 7-AAD decreased the fluorescence intensity and lifetime of the Ho-stained DNA. The spatially dependent phase and modulation values of Ho in the presence of 7-AAD showed that the Ho decay becomes nonexponential, as is expected for a resonance energy transfer (RET) with multiple acceptors located over a range of distances. In approximately 40 nuclei, the intensity and lifetime decrease was spatially homogeneous. In approximately 10 nuclei, addition of 7-AAD resulted in a spatially nonhomogeneous decrease in intensity and lifetime. The RET efficiency was higher in G(2)/M than in G(0/1) phase cells. CONCLUSIONS: Because RET efficiency depends on the average distance between Ho and 7-AAD, data suggest that the heterogeneity of lifetimes and spatial variation of the RET efficiency are caused by the presence of highly condensed regions of DNA in nuclei.  相似文献   

17.
18.
Fluorescence lifetime imaging microscopy (FLIM) is a technique in which the mean fluorescence lifetime of a chromophore is measured at each spatially resolvable element of a microscope image. The nanosecond excited-state lifetime is independent of probe concentration or light path length but dependent upon excited-state reactions such as fluorescence resonance energy transfer (FRET). These properties of fluorescence lifetimes allow exploration of the molecular environment of labelled macromolecules in the interior of cells. Imaging of fluorescence lifetimes enables biochemical reactions to be followed at each microscopically resolvable location within the cell.  相似文献   

19.
Identifying isocitrate dehydrogenase (IDH)-mutation and glioma subtype during surgery instead of days later can aid in modifying tumor resection strategies for better survival outcomes. We report intraoperative identification of IDH-mutant glioma (N = 12 patients) with a clinically compatible fluorescence lifetime imaging (FLIm) device (excitation: 355 nm; emission spectral bands: 390/40 nm, 470/28 nm, 542/50 nm). The fluorescence-derived parameters were analyzed to study the optical contrast between IDH-mutant tumors and surrounding brain tissue. IDH-mutant oligodendrogliomas exhibited shorter lifetimes (3.3 ± 0.1 ns) than IDH-mutant astrocytomas (4.1 ± 0.1 ns). Both IDH-mutant glioma subtypes had shorter lifetimes than white matter (4.6 ± 0.4 ns) but had comparable lifetimes to cortex. Lifetimes also increased with malignancy grade within IDH-mutant oligodendrogliomas (grade 2: 2.96 ± 0.08 ns, grade 3: 3.4 ± 0.3 ns) but not within IDH-mutant astrocytomas. The current results support the feasibility of FLIm as a surgical adjuvant for identifying IDH-mutant glioma tissue.  相似文献   

20.
BACKGROUND: The programmable array microscopes (PAMs) are a family of instruments incorporating arbitrary control of the patterns of illumination and/or detection. The PAM can be used in sectioning and nonsectioning modes, thereby constituting a useful platform for fluorescence lifetime imaging. METHODS AND RESULTS: We used a PAM for acquisition of optically sectioned and widefield fluorescence lifetime images, in which contrast was increased predominantly by suppressing out-of-focus light contributions. We simulate, display, and discuss the effects of blurring and fluorophore heterogeneity on lifetime imaging in widefield and confocal configurations. CONCLUSION: Sectioning improves the quality of lifetime images of samples with multiple fluorophores or spatially varying F?rster resonance energy transfer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号