首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Susceptibility of Legionella pneumophila to chlorine in tap water.   总被引:10,自引:9,他引:1       下载免费PDF全文
A study was conducted to compare the susceptibility of legionellae and coliforms to disinfection by chlorine. The chlorine residuals used were similar to concentrations that might be found in the distribution systems of large public potable water supplies. The effects of various chlorine concentrations, temperatures, and pH levels were considered. A number of different Legionella strains, both environmental and clinical, were tested. The results indicate that legionellae are much more resistant to chlorine than are coliform bacteria. At 21 degrees C, pH 7.6, and 0.1 mg of free chlorine residual per liter, a 99% kill of L. pneumophila was achieved within 40 min, compared with less than 1 min for Escherichia coli. The observed resistance is enhanced as conditions for disinfection become less optimal. The required contact time for the removal of L. pneumophilia was twice as long at 4 degrees C than it was at 21 degrees C. These data suggest that legionellae can survive low levels of chlorine for relatively long periods of time.  相似文献   

2.
Susceptibility of Legionella pneumophila to chlorine in tap water   总被引:7,自引:0,他引:7  
A study was conducted to compare the susceptibility of legionellae and coliforms to disinfection by chlorine. The chlorine residuals used were similar to concentrations that might be found in the distribution systems of large public potable water supplies. The effects of various chlorine concentrations, temperatures, and pH levels were considered. A number of different Legionella strains, both environmental and clinical, were tested. The results indicate that legionellae are much more resistant to chlorine than are coliform bacteria. At 21 degrees C, pH 7.6, and 0.1 mg of free chlorine residual per liter, a 99% kill of L. pneumophila was achieved within 40 min, compared with less than 1 min for Escherichia coli. The observed resistance is enhanced as conditions for disinfection become less optimal. The required contact time for the removal of L. pneumophilia was twice as long at 4 degrees C than it was at 21 degrees C. These data suggest that legionellae can survive low levels of chlorine for relatively long periods of time.  相似文献   

3.
Previous studies have shown that bacteria maintained in a low-nutrient "natural" environment such as swimming pool water are much more resistant to disinfection by various chemical agents than strains maintained on rich media. In the present study a comparison was made of the chlorine (Cl2) susceptibility of hot-water tank isolates of Legionella pneumophila maintained in tap water and strains passaged on either nonselective buffered charcoal-yeast extract or selective differential glycine-vancomycin-polymyxin agar medium. Our earlier work has shown that environmental and clinical isolates of L. pneumophila maintained on agar medium are much more resistant to Cl2 than coliforms are. Under the present experimental conditions (21 degrees C, pH 7.6 to 8.0, and 0.25 mg of free residual Cl2 per liter, we found the tap water-maintained L. pneumophila strains to be even more resistant than the agar-passaged isolates. Under these conditions, 99% kill of tap water-maintained strains of L. pneumophila was usually achieved within 60 to 90 min compared with 10 min for agar-passaged strains. Samples from plumbing fixtures in a hospital yielded legionellae which were "super"-chlorine resistant when assayed under natural conditions. After one agar passage their resistance dropped to levels of comparable strains which had not been previously exposed to additional chlorination. These studies more closely approximate natural conditions than our previous work and show that tap water-maintained L. pneumophila is even more resistant to Cl2 than its already resistant agar medium-passaged counterpart.  相似文献   

4.
Previous studies have shown that bacteria maintained in a low-nutrient "natural" environment such as swimming pool water are much more resistant to disinfection by various chemical agents than strains maintained on rich media. In the present study a comparison was made of the chlorine (Cl2) susceptibility of hot-water tank isolates of Legionella pneumophila maintained in tap water and strains passaged on either nonselective buffered charcoal-yeast extract or selective differential glycine-vancomycin-polymyxin agar medium. Our earlier work has shown that environmental and clinical isolates of L. pneumophila maintained on agar medium are much more resistant to Cl2 than coliforms are. Under the present experimental conditions (21 degrees C, pH 7.6 to 8.0, and 0.25 mg of free residual Cl2 per liter, we found the tap water-maintained L. pneumophila strains to be even more resistant than the agar-passaged isolates. Under these conditions, 99% kill of tap water-maintained strains of L. pneumophila was usually achieved within 60 to 90 min compared with 10 min for agar-passaged strains. Samples from plumbing fixtures in a hospital yielded legionellae which were "super"-chlorine resistant when assayed under natural conditions. After one agar passage their resistance dropped to levels of comparable strains which had not been previously exposed to additional chlorination. These studies more closely approximate natural conditions than our previous work and show that tap water-maintained L. pneumophila is even more resistant to Cl2 than its already resistant agar medium-passaged counterpart.  相似文献   

5.
A model was developed to study the multiplication of various Legionella spp. in tap water containing Hartmannella vermiformis. Tap water cultures prepared with the following components were suitable for the multiplication studies: Legionella spp., 10(3) CFU/ml; H. vermiformis, 10(4.4) cysts per ml; and killed Pseudomonas paucimobilis, 10(9) cells per ml. Cocultures were incubated at 37 degrees C for at least 1 week. The following legionellae multiplied in tap water cocultures in each replicate experiment: L. bozemanii (WIGA strain), L. dumoffii (NY-23 and TX-KL strains), L. micdadei (two environmental strains), and L. pneumophila (six environmental strains and one clinical isolate). Growth yield values for these strains were 0.6 to 3.5 log CFU/ml. Legionellae which did not multiply in replicate cocultures included L. anisa (one strain), L. bozemanii (MI-15 strain), L. micdadei (a clinical isolate), L. longbeachae, (one strain), and L. pneumophila (Philadelphia 1 strain). L. gormanii and an environmental isolate of L. pneumophila multiplied in only one of three experiments. None of the legionellae multiplied in tap water containing only killed P. paucimobilis. The mean growth yield (+/- standard deviation) of H. vermiformis in the cocultures was 1.2 +/- 0.1 log units/ml. H. vermiformis supports multiplication of only particular strains of legionellae, some of which are from diverse origins.  相似文献   

6.
A model was developed to study the multiplication of various Legionella spp. in tap water containing Hartmannella vermiformis. Tap water cultures prepared with the following components were suitable for the multiplication studies: Legionella spp., 10(3) CFU/ml; H. vermiformis, 10(4.4) cysts per ml; and killed Pseudomonas paucimobilis, 10(9) cells per ml. Cocultures were incubated at 37 degrees C for at least 1 week. The following legionellae multiplied in tap water cocultures in each replicate experiment: L. bozemanii (WIGA strain), L. dumoffii (NY-23 and TX-KL strains), L. micdadei (two environmental strains), and L. pneumophila (six environmental strains and one clinical isolate). Growth yield values for these strains were 0.6 to 3.5 log CFU/ml. Legionellae which did not multiply in replicate cocultures included L. anisa (one strain), L. bozemanii (MI-15 strain), L. micdadei (a clinical isolate), L. longbeachae, (one strain), and L. pneumophila (Philadelphia 1 strain). L. gormanii and an environmental isolate of L. pneumophila multiplied in only one of three experiments. None of the legionellae multiplied in tap water containing only killed P. paucimobilis. The mean growth yield (+/- standard deviation) of H. vermiformis in the cocultures was 1.2 +/- 0.1 log units/ml. H. vermiformis supports multiplication of only particular strains of legionellae, some of which are from diverse origins.  相似文献   

7.
Multiplication of Legionella pneumophila in unsterilized tap water.   总被引:22,自引:17,他引:5       下载免费PDF全文
Naturally occurring Legionella pneumophila, an environmental isolate which had not been grown on artificial medium, was tested for the ability to multiply in tap water. A showerhead containing L. pneumophila and non-Legionellaceae bacteria was immersed in nonsterile tap water supplying this fixture. Also L. pneumophila and non-Legionellaceae bacteria were sedimented from tap water from a surgical intensive care unit. This bacterial suspension was inoculated into tap water from our laboratory. The legionellae in both suspensions multiplied in the tap water at 32, 37, and 42 degrees C. The non-Legionellaceae bacteria multiplied at 25, 32, and 37 degrees C. A water sample which was collected from the bottom of a hot water tank was found to contain L. pneumophila and non-Legionellaceae bacteria. These legionellae also multiplied when the water sample was incubated at 37 degrees C. These results indicate that L. pneumophila may multiply in warm water environments such as hot water plumbing fixtures, hot water tanks, and cooling towers.  相似文献   

8.
Aims:  To assess chlorine susceptibility of Legionella pneumophila grown from two amoebic hosts, Acanthamoeba castellanii and Hartmannella vermiformis .
Methods and Results:  After being released from amoebae, Leg. pneumophila were chlorinated at 2 and 5 mg l−1 for 5 min–24 h. Bacterial culturability and cytoplasmic membrane deterioration were quantified by culture assay on BCYEα agar and BacLight stains coupled with a fluorescent microscope, respectively. Chlorination reduced the culturability of Leg. pneumophila by 2·93–4·59 log CFU ml−1 and damaged cellular membrane by 53·8–99·2%. Moreover, cells released from H. vermiformis exhibited significantly lower degrees in culturability reduction ( P  = 0·0008) and membrane deterioration ( P  < 0·0001) when compared with those from A. castellanii . The amoebic genus is the most significant parameter affecting cytoplasmic membrane integrity of chlorinated Legionella ( P  < 0·0001), followed by free chlorine concentration ( P  = 0·042).
Conclusions:  Legionella pneumophila replicated from H. vermiformis possess greater chlorine resistance than the cells from A. castellanii .
Significance and Impact of the Study:  This study shows the heterogeneity of amoebae-grown Leg. pneumophila in chlorine susceptibility, which should be considered in the control of legionellae proliferation, particularly in the systems where H. vermiformis is dominant, e.g. hot water plumbing.  相似文献   

9.
Abstract Legionella pneumophila occurring in drinking water was subjected to environmental stress through holding tests at ambient and elevated temperatures and by chemical disinfection. The bacterium in its native environment was more resistant to adverse conditions, as compared with laboratory-grown organisms. Of the several chemical disinfectants acceptable to drinking water treatment and tested for Legionella inactivation, ozonation was the most efficient method. The C · t ' products indicated that free chlorine was superior to mono- and dichloramines.  相似文献   

10.
The susceptibility of a strain of Legionella pneumophila to disinfection by an organic halamine, free chlorine, and a mixture of the organic halamine and free chlorine was assessed. The organic halamine was found to have superior stability in solution and to exhibit adequate disinfectant potential over a period of 1 month of repeated reinoculations of fresh bacteria. The combined halamine exhibited great potential for use in maintaining closed-cycle cooling water systems free of L. pneumophila.  相似文献   

11.
The susceptibility of a strain of Legionella pneumophila to disinfection by an organic halamine, free chlorine, and a mixture of the organic halamine and free chlorine was assessed. The organic halamine was found to have superior stability in solution and to exhibit adequate disinfectant potential over a period of 1 month of repeated reinoculations of fresh bacteria. The combined halamine exhibited great potential for use in maintaining closed-cycle cooling water systems free of L. pneumophila.  相似文献   

12.
A naturally occurring suspension of Legionella pneumophila and associated microbiota contained three unidentified non-Legionellaceae bacteria which supported satellite growth of a subculture of L. pneumophila on an L-cysteine-deficient medium and another bacterium which did not support growth of the subculture. Washed suspensions containing 10(3), 10(5), 10(7), or 10(8) CFU of a mixture of isolates of these non-Legionellaceae bacteria failed to support the multiplication of an isolate of agar-grown L. pneumophila which had been washed and seeded into the suspensions. The suspensions which contained 10(3), 10(5), or 10(7) CFU of the non-Legionellaceae bacteria per ml appeared to enhance survival or cryptic growth of agar-grown L. pneumophila. A decline of 1.3 log CFU of L. pneumophila per ml occurred within the first week of incubation in the sample which contained 10(8) CFU of the non-Legionellaceae bacteria per ml. In contrast to these results, naturally occurring L. pneumophila multiplied in the presence of associated microbiota. The necessity to subculture L. pneumophila and the non-Legionellaceae bacteria on artificial medium to obtain pure cultures may have affected the multiplication of L. pneumophila in tap water. Alternatively, other microorganisms may be present in the naturally occurring suspension which support the growth of this bacterium.  相似文献   

13.
A naturally occurring suspension of Legionella pneumophila and associated microbiota contained three unidentified non-Legionellaceae bacteria which supported satellite growth of a subculture of L. pneumophila on an L-cysteine-deficient medium and another bacterium which did not support growth of the subculture. Washed suspensions containing 10(3), 10(5), 10(7), or 10(8) CFU of a mixture of isolates of these non-Legionellaceae bacteria failed to support the multiplication of an isolate of agar-grown L. pneumophila which had been washed and seeded into the suspensions. The suspensions which contained 10(3), 10(5), or 10(7) CFU of the non-Legionellaceae bacteria per ml appeared to enhance survival or cryptic growth of agar-grown L. pneumophila. A decline of 1.3 log CFU of L. pneumophila per ml occurred within the first week of incubation in the sample which contained 10(8) CFU of the non-Legionellaceae bacteria per ml. In contrast to these results, naturally occurring L. pneumophila multiplied in the presence of associated microbiota. The necessity to subculture L. pneumophila and the non-Legionellaceae bacteria on artificial medium to obtain pure cultures may have affected the multiplication of L. pneumophila in tap water. Alternatively, other microorganisms may be present in the naturally occurring suspension which support the growth of this bacterium.  相似文献   

14.
The accumulation and fate of model microbial "pathogens" within a drinking-water distribution system was investigated in naturally grown biofilms formed in a novel pilot-scale water distribution system provided with chlorinated and UV-treated water. Biofilms were exposed to 1-mum hydrophilic and hydrophobic microspheres, Salmonella bacteriophages 28B, and Legionella pneumophila bacteria, and their fate was monitored over a 38-day period. The accumulation of model pathogens was generally independent of the biofilm cell density and was shown to be dependent on particle surface properties, where hydrophilic spheres accumulated to a larger extent than hydrophobic ones. A higher accumulation of culturable legionellae was measured in the chlorinated system compared to the UV-treated system with increasing residence time. The fate of spheres and fluorescence in situ hybridization-positive legionellae was similar and independent of the primary disinfectant applied and water residence time. The more rapid loss of culturable legionellae compared to the fluorescence in situ hybridization-positive legionellae was attributed to a loss in culturability rather than physical desorption. Loss of bacteriophage 28B plaque-forming ability together with erosion may have affected their fate within biofilms in the pilot-scale distribution system. The current study has demonstrated that desorption was one of the primary mechanisms affecting the loss of microspheres, legionellae, and bacteriophage from biofilms within a pilot-scale distribution system as well as disinfection and biological grazing. In general, two primary disinfection regimens (chlorination and UV treatment) were not shown to have a measurable impact on the accumulation and fate of model microbial pathogens within a water distribution system.  相似文献   

15.
A protocol for sampling environmental sites was developed and used to identify possible sources of Legionella species in support of epidemiologic investigations at two hospitals. In hospital A, legionellae were isolated from 43 of 106 (40%) different sites. Three separate Legionella pneumophila serotypes and a previously unrecognized species were present in different combinations in the positive samples. Two of five cooling towers contained the same L. pneumophila serogroup 1 monoclonal type (1,2,4,5) as was isolated from patients. The same monoclonal type was also isolated from make-up water for the two cooling towers, a hot water tank, water separators in four main air compressor systems for respiratory therapy, and cold and hot water faucets. In hospital B, 13 of 37 (38%) sample sites contained legionellae, all of which were L. pneumophila serogroup 1. The monoclonal type matching isolates from patients (1,2,4,5) was found at the highest concentration in a hot water tank, but it was also present at four other sample sites. Since legionellae not related to disease may be found in many of the sites sampled, an epidemiologic association with the probable source should be established before intervention methods, such as disinfection, are undertaken.  相似文献   

16.
Protocol for sampling environmental sites for legionellae.   总被引:4,自引:2,他引:2       下载免费PDF全文
A protocol for sampling environmental sites was developed and used to identify possible sources of Legionella species in support of epidemiologic investigations at two hospitals. In hospital A, legionellae were isolated from 43 of 106 (40%) different sites. Three separate Legionella pneumophila serotypes and a previously unrecognized species were present in different combinations in the positive samples. Two of five cooling towers contained the same L. pneumophila serogroup 1 monoclonal type (1,2,4,5) as was isolated from patients. The same monoclonal type was also isolated from make-up water for the two cooling towers, a hot water tank, water separators in four main air compressor systems for respiratory therapy, and cold and hot water faucets. In hospital B, 13 of 37 (38%) sample sites contained legionellae, all of which were L. pneumophila serogroup 1. The monoclonal type matching isolates from patients (1,2,4,5) was found at the highest concentration in a hot water tank, but it was also present at four other sample sites. Since legionellae not related to disease may be found in many of the sites sampled, an epidemiologic association with the probable source should be established before intervention methods, such as disinfection, are undertaken.  相似文献   

17.
Abstract Legionella pneumophila strains isolated from different sources were tested for their host range in the protists Acanthamoeba castellanii, Hartmannella vermiformis and Entamoeba histolytica . It has been shown that A. castellanii and H. vermiformis but not E. histolytica support the intracellular replication of L. pneumophila . Furthermore it could be demonstrated that in vivo virulence in the guinea pig and the intracellular growth in U937 cells coincides with the capability to replicate intracellularly in A. castellanii at 37°C. The infectivity of L. pneumophila that had sustained a 48 hours nutrient deprivation was not significantly different from that of legionellae grown to log-phase on BCYE plates. In contrast the nutrient limitation on A. castellanii increased the amount of intracellular legionellae at the beginning of infection. An initial opsonin independent attachement stage of legionellae to U937 cells was demonstrated by scanning electron microscopy. In contrast, L. pneumophila's capability of stable or long term attachmennt to A. castellanii was shown to be inefficient.  相似文献   

18.
Hartmannella vermiformis, a common amoebal inhabitant of potable-water systems, supports intracellular multiplication of Legionella pneumophila and is probably important in the transportation and amplification of legionellae within these systems. To provide a practical guide for decontamination of potable-water systems, we assessed the chlorine and heat resistance of H. vermiformis. H. vermiformis cysts and trophozoites were treated independently with chlorine at concentrations of 2.0 to 10.0 ppm for 30 min and then cocultured with L. pneumophila. Both cysts and trophozoites were sensitive to concentrations between 2.0 and 4.0 ppm and above (trophozoites somewhat more so than cysts), and 10.0 ppm was lethal to both forms. Hartmannellae treated with chlorine up to a concentration of 4.0 ppm supported the growth of legionellae. To determine whether heat would be an effective addendum to chlorine treatment of amoebae, hartmannellae were subjected to temperatures of 55 and 60°C for 30 min and alternatively to 50°C followed by treatment with chlorine at a concentration of 2 ppm. Fewer than 0.05% of the amoebae survived treatment at 55°C, and there were no survivors at 60°C. Pretreatment at 50°C appeared to make hartmannella cysts more susceptible to chlorine but did not further reduce the concentration of trophozoites.  相似文献   

19.
Contamination of hospital water systems with legionellae is a well-known cause of nosocomial legionellosis. We describe a new real-time LightCycler PCR assay for quantitative determination of legionellae in potable water samples. Primers that amplify both a 386-bp fragment of the 16S rRNA gene from Legionella spp. and a specifically cloned fragment of the phage lambda, added to each sample as an internal inhibitor control, were used. The amplified products were detected by use of a dual-color hybridization probe assay design and quantified with external standards composed of Legionella pneumophila genomic DNA. The PCR assay had a sensitivity of 1 fg of Legionella DNA (i.e., less than one Legionella organism) per assay and detected 44 Legionella species and serogroups. Seventy-seven water samples from three hospitals were investigated by PCR and culture. The rates of detection of legionellae were 98.7% (76 of 77) by the PCR assay and 70.1% (54 of 77) by culture; PCR inhibitors were detected in one sample. The amounts of legionellae calculated from the PCR results were associated with the CFU detected by culture (r = 0.57; P < 0.001), but PCR results were mostly higher than the culture results. Since L. pneumophila is the main cause of legionellosis, we further developed a quantitative L. pneumophila-specific PCR assay targeting the macrophage infectivity potentiator (mip) gene, which codes for an immunophilin of the FK506 binding protein family. All but one of the 16S rRNA gene PCR-positive water samples were also positive in the mip gene PCR, and the results of the two PCR assays were correlated. In conclusion, the newly developed Legionella genus-specific and L. pneumophila species-specific PCR assays proved to be valuable tools for investigation of Legionella contamination in potable water systems.  相似文献   

20.
The mechanisms by which Legionella pneumophila, a facultative intracellular parasite and the agent of Legionnaires' disease, acquires iron are largely unexplained. Several earlier studies indicated that L. pneumophila does not elaborate siderophores. However, we now present evidence that supernatants from L. pneumophila cultures can contain a nonproteinaceous, high-affinity iron chelator. More specifically, when aerobically grown in a low-iron, chemically defined medium (CDM), L. pneumophila secretes a substance that is reactive in the chrome azurol S (CAS) assay. Importantly, the siderophore-like activity was only observed when the CDM cultures were inoculated to relatively high density with bacteria that had been grown overnight to log or early stationary phase in CDM or buffered yeast extract. Inocula derived from late-stationary-phase cultures, despite ultimately growing, consistently failed to result in the elaboration of siderophore-like activity. The Legionella CAS reactivity was detected in the culture supernatants of the serogroup 1 strains 130b and Philadelphia-1, as well as those from representatives of other serogroups and other Legionella species. The CAS-reactive substance was resistant to boiling and protease treatment and was associated with the <1-kDa supernatant fraction. As would also be expected for a siderophore, the addition of 0.5 or 2.0 microM iron to the cultures repressed the expression of the CAS-reactive substance. Interestingly, the supernatants were negative in the Arnow, Csáky, and Rioux assays, indicating that the Legionella siderophore was not a classic catecholate or hydroxamate and, hence, might have a novel structure. We have designated the L. pneumophila siderophore legiobactin.  相似文献   