首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cysteine (Cys) and cystine residues in proteins are unstable under conditions used for acid hydrolysis of peptide bonds. To overcome this problem, we proposed the use of the S-pyridylethylation reaction to stabilize Cys residues as pyridylethyl-cysteine (PEC) protein derivatives. This suggestion was based on our observation that two synthetic derivatives formed by pyridylethylation of the SH group of Cys with either 2-vinylpyridine (2-VP) or 4-vinylpyridine (4-VP), designated as S--(2-pyridylethyl)-L-cysteine (2-PEC) and S--(4-pyridylethyl)-L-cysteine (4-PEC), were stable under acid conditions used to hydrolyze proteins. This was also the case for protein-bound PEC groups. Since their discovery over 30 years ago, pyridylethylation reactions have been widely modified and automated for the analysis of many structurally different proteins at levels as low as 20 picomoles, to determine the primary structures of proteins and to define the influence of SH groups and disulfide bonds on the structures and functional, enzymatic, medical, nutritional, pharmacological, and toxic properties of proteins isolated from plant, microbial, marine, animal, and human sources. Pyridylethylation has been accepted as the best method for the modification of Cys residues in proteins for subsequent analysis and sequence determination. The reaction has also been proposed to measure D-Cys, homocysteine, glutathione, tryptophan, dehydroalanine, and furanthiol food flavors. This integrated overview of the diverse literature on these reactions emphasizes general concepts. It is intended to serve as a resource and guide for further progress based on the reported application of pyridylethylation reactions to more than 150 proteins.  相似文献   

2.
The reagent 2-nitro-5-thiocyanatobenzoic acid (NTCB) is commonly used to cyanylate and cleave proteins at cysteine residues, but this two-step reaction requires lengthy incubations and produces highly incomplete cleavages. In previous reports, incomplete cleavage was attributed to a competing beta-elimination reaction that converts cyanylated cysteine to dehydroalanine. In this study, previously unidentified side reactions of the NTCB cleavage were discovered and beta-elimination was not the major reaction competing with peptide bond cleavage. A major side reaction was identified as carbamylation of lysine residues. Carbamylation could be minimized by desalting the cyanylation reaction before cleavage or by reducing the reactant concentrations, but both methods suffered from further reductions in cleavage efficiency. Based on model peptide studies, poor cleavage was primarily caused by a mass neutral rearrangement of the cyanylated cysteine which produced a cleavage-resistant, nonreducible product. The formation of this product could be minimized by using stronger nucleophiles for the cleavage reaction. We discovered that base-catalyzed nucleophilic cleavage could be achieved with many amino-containing compounds. Most notably, glycine is capable of promoting efficient cleavage. In addition, efficient NTCB cleavage can be performed in a simple one-step method without a prior cyanylation step, rather than the previously described two-step reaction.  相似文献   

3.
We report upon a novel procedure to specifically isolate cysteine-containing peptides from a complex peptide mixture. Cysteines are converted to hydrophobic residues by mixed disulfide formation with Ellman's reagent. Proteins are subsequently digested with trypsin and the generated peptide mixture is a first time fractionated by reverse-phase high-performance liquid chromatography. Cysteinyl-peptides are isolated out of each primary fraction by a reduction step followed by a secondary peptide separation on the same column, performed under identical conditions as for the primary separation. The reducing agent removes the covalently attached group from the cysteine side chain, making cysteine-peptides more hydrophilic and, thereby, such peptides can be specifically collected during the secondary separation and are finally used to identify their precursor proteins using automated liquid chromatography tandem mass spectrometry. We show that this procedure efficiently isolates cysteine-peptides, making the sample mixture less complex for further analysis. This method was applied for the analysis of the proteomes of human platelets and enriched human plasma. In both proteomes, a significant number of low abundance proteins were identified next to extremely abundant ones. A dynamic range for protein identification spanning 4-5 orders of magnitude is demonstrated.  相似文献   

4.
Hollemeyer K  Heinzle E  Tholey A 《Proteomics》2002,2(11):1524-1531
Oxidation of methionine residues in peptides and proteins occurs in vivo or may be an artifact resulting from purification steps. We present a three step method for the localization of methionine sulfoxides in peptides with two methionine residues. In the first step, the N-terminus as well as other reactive side chain functions are blocked by acetylation. The resulting protected peptides are cleaved by cyanogen bromide. The cleavage does not occur at methionine sulfoxide but only at reduced methionine residues forming new amino termini. The newly formed amino group is then derivatized with a bromine containing compound in the last step of the procedure. The resulting peptide can easily be identified by matrix-assisted laser desorption/ionization-time of flight mass spectrometry using both the characteristic isotope pattern of the halogen and the metastable loss of methanesulfenic acid from oxidized residues. This procedure allows the unequivocal localization of oxidized methionines even in complex peptide mixtures.  相似文献   

5.
Analysis of oligosaccharides in complex biological matrices is hampered by the fact that oligosaccharides, closely related in structure, are difficult to separate from each other and that conventional detection procedures (refraction index and uv detection) are not specific enough for carbohydrates. Prepurification of samples by procedures like desalting or gel filtration is often used but can lead to the loss of specific oligosaccharides. We have used pellicular anion chromatography in combination with a postcolumn reaction for reducing carbohydrates based on 4-aminobenzoylhydrazide. This procedure not only detected normal mono- and oligosaccharides but N-acetylhexosamines and reducing N-acetylhexosamine containing oligosaccharides as well. A sensitivity of about 20-25 pmol for non-GlcNAc containing mono- or oligosaccharides and between 30-50 pmol for GlcNAc or oligosaccharides with GlcNAc at the reducing side was reached. The postcolumn detection was compared with pulsed amperometric detection and appeared to be more specific for mono- and oligosaccharides. Except for deproteination to protect the column, no further sample preparation was needed with this system for our application (urines). In this way pellicular anion chromatography in combination with this postcolumn reaction reaction to be a sensitive and specific HPLC procedure for analysis of monosaccharides and oligosaccharides in complex biological matrices.  相似文献   

6.
Purple membranes were prepared in which bacteriorhodopsin was labeled at lysine 41 with phenylisothiocyanate (PITC) and with perdeuterated PITC. The in-plane position of this small label containing only five deuterons was determined from the differences between the neutron diffraction intensities of the two samples. At 8.7-Å resolution the Fourier difference map revealed a well-defined site between helices 3 and 4. This position was confirmed by a refinement procedure in reciprocal space. Model calculations showed that the observed difference density had the right amplitude for the label. Thus it is possible to locate a small group in a large protein structure by replacing as few as five hydrogens by deuterium. The observed location of PITC restricts the number of possibilities for the assignment of helix B in the sequence (to which lysine 41 is attached) to one of the seven helices of the structure. Taking into account the size of the label and the length of the lysine side chain our result excludes helices 1, 2, and 7 as candidates for B.  相似文献   

7.
Garaguso I  Borlak J 《Proteomics》2008,8(13):2583-2595
The analytical performance of MALDI-MS is highly influenced by sample preparation and the choice of matrix. Here we present an improved MALDI-MS sample preparation method for peptide mass mapping and peptide analysis, based on the use of the 2,5-dihydroxybenzoic acid matrix and prestructured sample supports, termed: matrix layer (ML). This sample preparation is easy to use and results in a rapid automated MALDI-MS and MS/MS with high quality spectra acquisition. The between-spot variation was investigated using standard peptides and statistical treatment of data confirmed the improvement gained with the ML method. Furthermore, the sample preparation method proved to be highly sensitive, in the lower-attomole range for peptides, and we improved the performance of MALDI-MS/MS for characterization of phosphopeptides as well. The method is versatile for the routine analysis of in-gel tryptic digests thereby allowing for an improved protein sequence coverage. Furthermore, reliable protein identification can be achieved without the need of desalting sample preparation. We demonstrate the performance and the robustness of our method using commercially available reference proteins and automated MS and MS/MS analyses of in-gel digests from lung tissue lysate proteins separated by 2-DE.  相似文献   

8.
We have recently improved the automation of an in-gel digestion system, DigestPro 96, using in situ alkylation of proteins with acrylamide, conducted during one-dimensional (1D) SDS-PAGE. The improved method included the processes of destaining, dehydration, trypsin digestion, and extraction but excluded the reduction and alkylation steps following staining of proteins with CBB. The extracted peptide mixtures were directly loaded onto a micro C18 LC column of the mass spectrometer. The resultant spectra were processed with “Mascot” search engine to estimate the sequence coverage of the bovine serum albumin (BSA). The original method, designed for Laemmli 1D SDS gel applications, consisted of reduction and post-alkylation with iodoacetamide, which produced carboxyamidemethyl (CAM; –S–CH2CONH2) derivatives. The original method also included a desalting step essential for mass spectrometry, especially matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. We compared the original and improved methods using BSA (3 pmol loaded to the gel, one third of digested peptide mixture injected into LC-MS). The original method yielded both CAM and propionicamide (PAM; –S–CH2CH2CONH2) derivatives. The source of PAM derivatives is the unpolymerized acrylamide formed during electrophoresis. The sequence coverage of CAM derivatives of BSA by the original method was 10% with desalting and 19% without desalting. The sequence coverage of PAM derivative by the improved method was 32%. Our results clearly show the advantage of our improved automated in-gel digestion method for in situ PAM alkylated protein with respect to peptide recovery, compared with the original method with CAM post-alkylation.  相似文献   

9.
We present an optimized procedure for the synthesis of (S)-vinylglycine from (S)-methionine. The key step is a solvent free pyrolysis of an intermediate sulfoxide at high temperature. Using our optimized reaction conditions, Cbz-protected vinylglycine was obtained in high yield and with almost no side products. The protocol is scalable, fast and avoids the use of poisonous reagents.  相似文献   

10.
A procedure for reduction and alkylation of cysteine residues in proteins was developed using the volatile reagents triethylphosphine and iodoethanol. These reagents may be used to modify proteins in solution, as well as proteins in gel slices, prior to proteolytic digestion and mass spectral analysis. The procedure eliminates several steps with both types of samples. Samples in solution do not need to be desalted following reduction and alkylation, with excess reagent being removed under vacuum. For gel slices, the procedure combines washing, destaining, reduction and alkylation into a single step. The procedure was applied successfully to samples as complex as serum, and we demonstrated alkylation of cysteines to be quantitative in purified proteins. We also were able to reduce and alkylate proteins with these reagents during the gas phase. Elimination of the need for desalting of samples after reaction raised the possibility of automation of the procedure for liquid samples, which is difficult with conventional reduction and alkylation chemistries.  相似文献   

11.
Conjugation of haptens through ether linkages avoids leakage problems in immunoassays, but this procedure is not easily applied to most steroids that bear low reacting hydroxyls. A new technique allowing the ether coupling of biologically active steroids with conjugating arms in mild conditions compatible with thermosensitive protecting groups is presented. In the first step, the solvent (an aromatic hydrocarbon) was dehydrated by azeotropic distillation in a soxhlet apparatus using a cartridge filled with 0.3 nm and 0.4 nm molecular sieves. In this protected medium, a thallium steroid alkoxide was completely formed by reaction of the steroid with thallium ethoxide and by the continuous elimination of ethanol. The halogenated chain was then introduced into the same medium and reacted in the absence of moisture to give the ether. 17beta-Hydroxy and 11alpha-hydroxy derivatives were involved in this reaction. The coupling was effective for all of the compounds tested after 2-36 h of reaction time and at temperatures between 80 and 140 degrees C. The conjugates were at least 95% pure, and yields ranged from 15 to 95%.  相似文献   

12.
Hydrophilic peptides in shotgun proteomics have been shown to be problematic in conventional chromatography. Typically, C18 solid phase extraction or peptide traps are used for desalting the sample prior to mass spectrometry analysis, but the capacity to retain hydrophilic peptides is not very high, causing a bias toward more hydrophobic peptides. This is particularly problematic in phosphoproteomic studies. We tested the compatibility of commercially available boron nitride as a novel material for peptide desalting. Boron nitride can be used to recover a wide range of peptides with different physicochemical properties comparable to combined C18 and graphite carbon material.  相似文献   

13.
A completely automated peptide mapping liquid chromatography/mass spectrometry (LC/MS) system for characterization of therapeutic proteins in which a common high-performance liquid chromatography (HPLC) autosampler is used for automated sample preparation, including protein denaturation, reduction, alkylation, and enzymatic digestion, is described. The digested protein samples are then automatically subjected to LC/MS analysis using the same HPLC system. The system was used for peptide mapping of monoclonal antibodies (mAbs), known as a challenging group of therapeutic proteins for achieving complete coverage and quantitative representation of all peptides. Detailed sample preparation protocols, using an Agilent HPLC system, are described for Lys-C digestion of mAbs with intact disulfide bonds and tryptic digestion of mAbs after reduction and alkylation. The automated procedure of Lys-C digestion of nonreduced antibody, followed by postdigestion disulfide reduction, produces both the nonreduced and reduced digests that facilitate disulfide linkage analysis. The automated peptide mapping LC/MS system has great utility in preparing and analyzing multiple samples for protein characterization, identification, and quantification of posttranslational modifications during process and formulation development as well as for protein identity and quality control.  相似文献   

14.
Summary A simple yet highly effective application of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for the rapid monitoring of Fmoc solid-phase peptide synthesis is described. A few beads of the resin are removed at any desired step during synthesis, the fully protected peptide is cleaved from the resin and an MS spectrum of the analytes present is produced. Some standard side-chain protecting groups may be cleaved off during sample preparation for MS analysis; however, these cleavages are readily identified. Using this approach, incomplete amino acid acylations are readily detected in approximately the same time as by traditional tests such as ninhydrin. The semi-on-line method also lends itself to ready optimization of synthesis protocols and to the examination of resin-bound peptide side reactions which may not be detectable by chemical means.  相似文献   

15.
Background generated during the cleavage step of the Edman degradation is a major obstacle to extended automated amino acid sequencing. It was demonstrated recently by A. S. Bhown, J. C. Bennett, P. H. Morgan, and J. E. Mole (1981, Anal. Biochem. 112, 158-162) that introduction of fluorescamine into the spinning cup reduced background by blocking primary amino groups at cycles where a proline residue is at the exposed amino terminus. A convenient blocking reaction program using o-phthalaldehyde which can be intercalated into the sequencing format of an automated Beckman liquid-phase sequencer is presented. The advantages of o-phthalaldehyde in blocking of primary amines when proline is amino terminal arise from its stability in aqueous solution and the ease of programmed metering of delivery to the sequencer spinning cup. The blocking reaction proved successful not only in extending sequence analyses but also in the elimination of unwanted sequences in selected peptide mixtures without the necessity of purification of the target peptide.  相似文献   

16.
The phenylthiohydantoin (PTH) derivatives of 3- and 4-hydroxyproline (Hyp) were separated using micellar electrokinetic capillary electrophoresis (MEKC). The separation protocol was also used to determine Hyp content of bovine skeletal perimysial collagen preparations and whole muscle samples. Amino acids from hydrolyzed tissues were labeled using a two step procedure that involved initial reaction with o-phthalaldehyde (OPA) to modify primary amines followed by their precipitation under acidic conditions. In the second step, imino acids were reacted with phenyl isothiocyanate (PITC). This labeling method was rapid and the Hyp values determined in these biological samples were found to be in close agreement with conventional methods and other published reports.  相似文献   

17.
Immobilized metal affinity chromatography (IMAC) and metal oxide type affinity chromatography (MOAC) techniques have been widely used for mass spectrometry-based phosphorylation analysis. Unlike MOAC techniques, IMAC requires rather complete removals of buffering reagents, salts and high concentrations of denaturant prior to sample loading in order for the successful enrichment of phosphopeptides. In this study, a simple off-line capillary column-based IMAC phosphopeptide enrichment method can shorten sample preparation time by eliminating the speed-vac step from the desalting process. Tryptic digest peptide samples containing 2M urea can be directly processed and the entire IMAC procedure can be completed within 6 h. When tryptic digest peptide samples prepared from mouse whole brain tissues were analyzed using our method, an average of 249 phosphoproteins and 463 unique phosphopeptides were identified from single 2-h RPLC-MS/MS analysis (~88% specificity). An additional advantage of this method is the significantly improved reproducibility of the phosphopeptide enrichment results. When four independent phosphopeptide enrichment experiments were carried out, the peak areas of phosphopeptides identified among four enrichment experiments were relatively similar (less than 16.2% relative standard dev.). Because of this increased reproducibility, relative phosphorylation quantification analysis of major phosphoproteins appears to be feasible without the need for stable isotope labeling techniques.  相似文献   

18.
We report the amino acid sequence of a basic protein isolated from the snake venom of Naja naja atra. An automated Edman sequencer was used to determine the 65-residue sequence, aided by electrospray ionization/mass spectrometry. Online reduction and pyridylethylation of the peptide was performed to identify the cysteine residues. Trypsin, chymotrypsin and aspartic digestions were carried out to derive peptide fragments for further sequencing. Fragmented peptides were overlapped to obtain the complete sequence. Molecular mass measurements of the whole protein and its fragments were used as a countercheck for sequence assignment. Further confirmation of the sequence was indicated by sequence homology to other snake venom neurotoxins. A molecular model of the tertiary structure was constructed based on sequence homology, and was refined by global minimization and extensive quality control algorithms. Electrostatic and hydrophobic surface calculations and molecular dynamics simulations were carried out to determine the functional properties of the molecule.  相似文献   

19.
The strategy of this study involves automated synthesis of oligonucleotides on a CPG support using standard cyanoethyl phosphoramidite chemistry followed by covalent linkage to peptide fragments bearing a free terminal alpha-amino group and residues with protected side chains. Conjugation was formed through an alkyldiisocyanate linker. Conjugates were isolated by cleavage from the solid support and deprotection in one step.  相似文献   

20.
A simple cryogenic holder for tensile testing of soft biological tissues   总被引:2,自引:0,他引:2  
To overcome the difficulty of gripping soft biological materials for tensile test, a simple inexpensive cryogenic holder was developed which allows rapid (3 min) preparation of samples. It is made of 6 parts, built in a bakelite cloth, which is an excellent thermal isolant, and is used with rectangular (8x10(-2)x10(-2)x10(-2)m) samples. The holder with the sample inside is completely immersed in liquid nitrogen for 50 s. This duration allows the freezing of the sample ends on a 10(-2)m length and gives a very flat freezing surface throughout the sample cross section. The 6x10(-2)m central part of the sample remained at ambient temperature. Two parts of the holder help maintain the sample until its ends are vertically gripped in the tensile machine thus avoiding any sample deformation during this step. No pressure was applied on the frozen part of the sample by grips of the tensile machine and this avoids breaks in this region. The sample is fixed by adhesion forces (>1 kN) between its frozen parts and 2 pieces of the holder. The procedure has been successfully tested with bovine and salmon muscle samples and results show tensile breaks randomly distributed in the unfrozen region of the samples. Particular attention has been paid to obtain a very flat freezing surface so that the axial strain is equal throughout the sample and therefore any strain-related mechanical parameters can be accurately determined. The dimensions of the holder can be easily modified to fit other sample geometries and can be used with other biological materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号