首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
5-Azacytidine (5AC), a nucleoside analogue and hypomethylating agent, has anticancer properties and has been utilized in the treatment of various malignancies. 5AC is unstable and rapidly hydrolyzed to several by-products, including 5-azacytosine and 5-azauracil. A sensitive, reliable method was developed to quantitate 5AC using LC/MS/MS to perform pharmacokinetic and pharmacodynamic studies on 5AC combination therapy trials. Blood samples were collected in a heparinized tube and immediately processed for storage. To increase the stability of 5AC in plasma, 25 ng/mL tetrahydrouridine was added to the plasma and snap frozen. Plasma samples were extracted using acetonitrile then cleaned up by Oasis MCX ion exchange solid-phase extraction cartridges. 5AC was separated on an YMC Jsphr M80 C(18) column with gradient elution of ammonium acetate (2 mM) with 0.1% formic acid and methanol mobile phase. 5AC elutes at 5.0 +/- 0.2 min with a total run time of 30 min. Identification was through positive-ion mode and multiple reaction monitoring mode at m/z+ 244.9-->113.0 for 5AC and m/z+ 242.0-->126.0 for 5-methyl-2'-deoxycytidine, the internal standard. The lower limit of quantitation of 5AC was 5 ng/mL in human plasma, and linearity was observed from 5 to 500 ng/mL fitted by linear regression with 1/x weight. This method is 50 times more sensitive than previously published assays and successfully allows studies to characterize the pharmacokinetics and pharmacodynamics of 5AC.  相似文献   

2.
Astragaloside IV (AGS-IV) is an active constituent of Radix Astragali used in many Traditional Chinese Medicines. This paper describes a sensitive and specific assay for the quantitation of AGS-IV in rat plasma. After solid phase extraction (SPE), samples were analyzed by liquid chromatography electrospray ionization mass spectrometry using a reversed-phase C18 column. The assay was linear in the range 1-500 ng/ml with a limit of detection of 0.5 ng/ml. The recovery was 92.5% and within-day and between-day precision were 3.7-6.0 and 2.8-9.8%, respectively. The assay was applied to a pharmacokinetic study in rat after a single oral dose. The drug was rapidly absorbed and subsequently eliminated according to a biphasic concentration-time curve.  相似文献   

3.
Atractylenolide III is a major active component in Atractylodes macrocephala. This paper describes a simple, rapid, specific and sensitive method for the quantification of atractylenolide III in rat plasma using a liquid-liquid extraction procedure followed by liquid chromatography mass spectrometric (LC-MS) analysis. A Kromasil 3.5 microm C(18) column (150 mm x 2.00 mm) was used as the analytical column. Linear detection responses were obtained for atractylenolide III concentration ranging from 5 to 500 ng L(-1). The precision and accuracy data, based on intra-day and inter-day variations over 5 days were within 10.29%. The lower limit of quantitation for atractylenolide III was 5 ng mL(-1), using 0.1 mL plasma for extraction and its recoveries were greater than 85% at the low, medium and high concentrations. The method has been successfully applied to a pharmacokinetic study in rats after an oral administration of atractylenolide III with a dose of 20.0 mg kg(-1). With the lower limits of quantification at 5 ng mL(-1) for atractylenolide III, this method was proved to be sensitive enough for the pharmacokinetics study of atractylenolide III.  相似文献   

4.
An electrospray mass spectrometric method for the quantification of the depolarizing neuromuscular blocking agent succinylcholine (SUX) is described. An extraction method compatible with direct infusion inlet was developed and leads to an analysis cycle time of 7--8 min instead of 25 min that would be required for HPLC inlet. SUX was extracted from human plasma on C1 solid-phase cartridges and was analyzed using positive ion electrospray tandem mass spectrometry (ESI-MS/MS). SUX plasma concentrations were determined by a stable isotope dilution assay using hexadeuterosuccinylcholine diiodide (SUXd6) as the internal standard. The calibration curve was prepared using the ratio of intensities of the major product ions in the collision-induced dissociation spectrum for known concentration ratios of SUX and SUXd6 in plasma. Calibration curves for the quantification were linear from 25 to 4000 ng/ml. For intraday precision, CV were < or =6% and accuracy ranged from 98 to 103%. For the interday precision, CV were < or =10% and accuracy ranged from 90 to 102%. This method is specific, sensitive, reproducible, and practical in a clinical setting.  相似文献   

5.
A sensitive and specific method using a one-step liquid-liquid extraction (LLE) with ethyl acetate followed by high-performance liquid chromatography (HPLC) coupled with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed and validated for the determination of roxatidine in human plasma using famotidine as an internal standard (IS). Data acquisition was carried out in multiple reaction monitoring (MRM) mode, by monitoring the transitions m/z 307.3-->107.1 for roxatidine and m/z 338.4-->189.1 for famotidine. Chromatographic separation was performed on a reverse phase Hydrosphere C(18) column at 0.2 mL min(-1) using a mixture of methanol-ammonium formate buffer as mobile phase (20:80, v/v; adjusted to pH 3.9 with formic acid). The achieved lower limit of quantification (LLOQ) was 1.0 ng mL(-1) and the standard calibration curve for roxatidine was linear (r(2)=0.998) over the studied range (1-1000 ng mL(-1)) with acceptable accuracy and precision. Roxatidine was found to be stable in human plasma samples under short-, long-term storage and processing conditions. The developed method was validated and successfully applied to the bioequivalence study of roxatidine administrated as a single oral dose (75 mg as roxatidine acetate hydrochloride) to healthy female Korean volunteers.  相似文献   

6.
We present an optimized and validated liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method for the simultaneous measurement of concentrations of different ceramide species in biological samples. The method of analysis of tissue samples is based on Bligh and Dyer extraction, reverse-phase high-performance liquid chromatography separation, and multiple reaction monitoring of ceramides. Preparation of plasma samples also requires isolation of sphingolipids by silica gel column chromatography prior to LC-ESI-MS/MS analysis. The limits of quantification were in a range of 0.01-0.50 ng/ml for distinct ceramides. The method was reliable for inter- and intraassay precision, accuracy, and linearity. Recoveries of ceramide subspecies from human plasma, rat liver, and muscle tissue were 78 to 91%, 70 to 99%, and 71 to 95%, respectively. The separation and quantification of several endogenous long-chain and very-long-chain ceramides using two nonphysiological odd chain ceramide (C17 and C25) internal standards was achieved within a single 21-min chromatographic run. The technique was applied to quantify distinct ceramide species in different rat tissues (muscle, liver, and heart) and in human plasma. Using this analytical technique, we demonstrated that a clinical exercise training intervention reduces the levels of ceramides in plasma of obese adults. This technique could be extended for quantification of other ceramides and sphingolipids with no significant modification.  相似文献   

7.
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of zolmitriptan in human plasma. After the addition of the internal standard (IS) and 1.0 M sodium hydroxide solution, plasma samples were extracted with methylene chloride:ethyl acetate mixture (20:80, v/v). The organic layer was evaporated under a stream of nitrogen at 40 degrees C. The residue was reconstituted with 100 microl mobile phase. The compounds were separated on a prepacked Lichrospher CN (5 microm, 150 mm x 2.0 mm) column using a mixture of methanol:water (10 mM NH(4)AC, pH 4.0) = 78:22 as mobile phase. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.30-16.0 ng/ml with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. The intra- and inter-day precision (R.S.D.%) were lower than 15% and accuracy ranged from 85 to 115%. The lower limit of quantification was identifiable and reproducible at 0.30 ng/ml. The proposed method enables the unambiguous identification and quantification of zolmitriptan for pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

8.
A rapid, sensitive and specific method was developed and validated using LC/MS/MS for determination of sunitinib in human plasma. Sample preparation involved a liquid-liquid extraction by the addition of 0.2mL of plasma with 4.0mL tert-butyl-methyl-ether extraction solution containing 25ng/mL of the internal standard clozapine. Separation of compounds was achieved on a C18 (50mmx2.1mm i.d., 3.5microm) analytical column using a mobile phase consisting of acetonitrile/H20 (65:35, v/v) containing 0.1% formic acid and isocratic flow at 0.150mL/min for 3min. The analytes were monitored by tandem-mass spectrometry with electrospray positive ionization. Linear calibration curves in human plasma were generated over the range of 0.2-500ng/mL with values for the coefficient of determination of >0.9950. Within- and between day precision and accuracy were < or =10%. The method was applied to the quantitation of sunitinib in plasma samples from a patient receiving daily oral therapy with sunitinib.  相似文献   

9.
A rapid, sensitive and specific method to quantify carvedilol in human plasma using metoprolol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using a diethyl-ether solvent. After removed and dried the organic phase, the extracts were reconstituted with a fixed volume of acetonitrile-water (50/50; v/v). The extracts were analyzed by a high performance liquid chromatography coupled to electrospray tandem mass spectrometry (HPLC-MS/MS). Chromatography was performed isocratically on Alltech Prevail C18 5 microm analytical column, (150 mm x 4.6 mm i.d.). The method had a chromatographic run time of 3.5 min and a linear calibration curve over the range 0.1-200 ng ml(-1) (r2>0.997992). The limit of quantification was 0.1 ng ml(-1). This HPLC-MS/MS procedure was used to assess the bioequivalence of two carvedilol 25 mg tablet formulations (carvedilol test formulation from Laboratórios Biosintética Ltda and Coreg from Roche Químicos e Farmacêuticos S.A standard reference formulation). A single 25 mg dose of each formulation was administered to healthy volunteers. The study was conducted using an open, randomized, two-period crossover design with a 2-week wash-out interval. Since the 90% CI for C(max) and AUCs ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration Agency, it was concluded that carvedilol formulation elaborated by Laboratórios Biosintética Ltda is bioequivalent to Coreg formulation for both the rate and the extent of absorption.  相似文献   

10.
The endocannabinoids anandamide, palmitoylethanolamide and oleoylethanolamide have been detected in human seminal plasma and are bioactive lipids implicated in regulation of sperm motility, capacitation and acrosome reaction. Several methods exist for endocannabinoid quantification but none have been validated for measurement in human seminal plasma. We describe sensitive, robust, reproducible solid phase and isotope-dilution UHPLC-ESI-MS/MS methods for the extraction and quantification of anandamide, palmitoylethanolamide and oleoylethanolamide in human seminal plasma. Precision and accuracy were evaluated using pooled seminal plasma over a 4 day period. For all analytes, the inter- and intraday precision (CV%) was between 6.6-17.7% and 6.3-12.5%, respectively. Analyses were linear over the range 0.237-19nM for anandamide and oleoylethanolamide and 0.9-76nM for PEA. Limits of detection (signal-to-noise >3) were 50, 100 and 100fmol/mL and limits of quantification (signal-to-noise >10) were 100, 200 and 200fmol/mL, respectively for anandamide, palmitoylethanolamide and oleoylethanolamide. Anandamide and oleoylethanolamide were stable at -80°C for up to 4 weeks, but palmitoylethanolamide declined significantly. We assessed seminal plasma from 40 human donors with normozoospermia and found mean (inter-quartile range) concentrations of 0.21nM (0.09-0.27), 1.785nM (0.48-2.32) and 15.54nM (7.05-16.31) for anandamide, oleoylethanolamide and palmitoylethanolamide, respectively. Consequently, this UHPLC-ESI-MS/MS method represents a rapid, reliable and reproducible technique for the analysis of these endocannabinoids in fresh seminal plasma.  相似文献   

11.
Globoid cell leukodystrophy (Krabbe disease) is an autosomal recessive inherited neurodegenerative disorder caused by the deficiency of the lysosomal enzyme beta-galactosylceramidase. The pathogenesis of the disorder has been proposed to arise from the accumulation of the cytotoxic metabolite galactosylsphingosine (psychosine). The twitcher mouse is a naturally occurring murine model of globoid cell leukodystrophy. We have developed a rapid, sensitive, and specific mass spectrometric method for determining the galactosylsphingosine concentration in the tissues of twitcher mice. Galactosylsphingosine is extracted from the tissues in methanol, isolated using strong cation-exchange and C18 solid-phase extraction chromatography, and then directly analyzed using electrospray ionization-tandem mass spectrometry. A lactosylsphingosine internal standard has been employed for quantification. The assay demonstrated significant accumulation of galactosylsphingosine in the brain, spinal cord, and kidney of twitcher mice. It is anticipated that this method may be of use in the monitoring of experimental therapies for globoid cell leukodystrophy.  相似文献   

12.
A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of lipoic acid (LA) in human plasma. LA and the internal standard, naproxen, were extracted from a 500 microl plasma sample by one-step deproteination using acetonitrile. Chromatographic separation was performed on a Zorbax SB-C(18) Column (100 mmx3.0mm i.d. with 3.5 microm particle size) with the mobile phase consisting of acetonitrile and 0.1% acetic acid (pH 4, adjusted with ammonia solution) (65:35, v/v), and the flow rate was set at 0.3 ml/min. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was linear over the concentration range of 5-10,000 ng/ml for LA. The intra- and inter-day precisions were less than 7% and accuracy ranged from -7.87 to 9.74% at the LA concentrations tested. The present method provides a relatively simple and sensitive assay with short turn-around time. The method has been successfully applied to a clinical pharmacokinetic study of LA in 10 healthy subjects.  相似文献   

13.
A method of accurate mass determination of phosphoramidites is described. The commonly used methanol/water/acid system was replaced by LiCl-containing acetonitrile and the concentrations of LiCl, poly(ethylene glycol), and phosphoramidite samples were optimized.  相似文献   

14.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantitation of tadalafil (I) in human plasma, a new selective, reversible phosphodiesterase 5 inhibitor. The analyte and internal standard (sildenafil, II) were extracted by liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on reverse phase Xterra MS C18 column with a mobile phase of 10mM ammonium formate/acetonitrile (10/90, v/v, pH adjusted to 3.0 with formic acid). The protonate of analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 390.4 --> 268.0 and m/z 475.5 --> 58.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-1000 ng/mL for tadalafil in human plasma. The lower limit of quantitation was 10 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 1.2 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

15.
The report describes for the first time the enantioselective analysis of fluvastatin in plasma using LC-MS-MS. The enantiomers of fluvastatin (FV) were extracted from plasma with diisopropyl ether at pH 5.0. The enantiomers were separated on a ChiralCel OD-R column with a mobile phase consisting of a mixture of acetonitrile, methanol and water (24:36:40) containing 0.1% formic acid. The protonated ions and their respective product ions were monitored in two functions, 410.6>348.2 for FV enantiomers and 307.1>161.6 for the internal standard (warfarin). Recoveries were higher than 90% and the quantitation limit was 1.5 ng mL(-1) plasma for both enantiomers. The coefficients of variation and the relative errors obtained for the validation of the intra- and interassay precision and accuracy were less than 10%. The method was applied to the investigation of the enantioselective pharmacokinetics of FV administered in a single dose of 40 mg (Lescol, Novartis, S?o Paulo, SP, Brazil) to a patient with primary hypertension and hypercholesterolemia and genotyped as CYP2C9*1/*1. The data showed higher plasma concentrations of the (-)-3S,5R-fluvastatin enantiomer, with an AUC (-)/(+) of 1.84. Oral clearance values (CL/F) were 29.27 and 49.58 L/h, respectively, for the (-)-3S,5R- and (+)-3R,5S-fluvastatin enantiomers.  相似文献   

16.
Procarbazine is a cytotoxic chemotherapeutic agent used in the treatment of lymphomas and brain tumors. Its pharmacokinetic behavior remains poorly understood even though more than 30 years have elapsed since the drug was approved for clinical use. To characterize the pharmacokinetics of procarbazine in brain cancer patients during a phase I trial, a method for determining the drug in human plasma by reversed-phase high-performance liquid chromatography (HPLC) with electrospray ionization mass spectrometry (ESI-MS) was developed and thoroughly validated. Plasma samples were prepared for analysis by precipitating proteins with trichloroacetic acid and washing the protein-free supernatant with methyl tert-butyl ether to remove excess acid. The solution was separated on a Luna C-18 analytical column using methanol-25 mM ammonium acetate buffer, pH 5.1 (22:78, v/v) as the mobile phase at 1.0 ml/min. A single-quadrupole mass spectrometer with an electrospray interface was operated in the selected-ion monitoring mode to detect the [M+H](+) ions at m/z 222.2 for procarbazine and at m/z 192.1 for the internal standard (3-dimethylamino-2-methylpropiophenone). Procarbazine and the internal standard eluted as sharp, symmetrical peaks with retention times (mean+/-S.D.) of 6.3+/-0.1 and 9.9+/-0.3 min, respectively. Calibration curves of procarbazine hydrochloride in human plasma at concentrations ranging from 0.5 to 50 ng/ml exhibited excellent linearity. The mean absolute recovery of the drug from plasma was 102.9+/-1.0%. Using a sample volume of 150 microl, procarbazine was determined at the 0.5 ng/ml (1.9 nM) lower limit of quantitation with a mean accuracy of 105.2% and an interday precision of 3.60% R.S.D. on 11 different days over 5 weeks. During this same time interval, the between-day accuracy for determining quality control solutions of the drug in plasma at concentrations of 2.0, 15 and 40 ng/ml ranged from 97.5 to 98.2% (mean+/-S.D., 97.9+/-0.4%) and the precision was 3.8-6.2% (mean+/-S.D., 5.1+/-1.2%). Stability characteristics of the drug were thoroughly evaluated to establish appropriate conditions to process, store and prepare clinical specimens for chromatographic analysis without inducing significant chemical degradation. The sensitivity achieved with this assay permitted the plasma concentration-time profile of the parent drug to be accurately defined following oral administration of standard doses to brain cancer patients.  相似文献   

17.
The validation of a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the determination of the selective cyclooxygenase-2 inhibitor etoricoxib in human plasma with phenazone as internal standard is described. The plasma samples were extracted by solid-phase extraction using polymer-based cartridges. Chromatography was carried out on a short, narrow bore RP C(18) column (30x2 mm). Detection was achieved by a Sciex API 3000 triple quadrupole mass spectrometer equipped with a turbo ion spray source working in positive ion mode. The respective mass transitions used for quantification of etoricoxib and phenazone were m/z 359.2-->280.2 and m/z 189.0-->104.1. The analytical method was validated over the concentration range 0.2-200 ng/ml. The limit of quantification was 0.2 ng/ml. The method is applicable to pharmacokinetic studies in humans.  相似文献   

18.
A rapid and sensitive liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of rimantadine in rat plasma. Rimantadine was extracted by protein precipitation with methanol, and the chromatographic separation was performed on a C(18) column. The total analytical run time was relatively short (4.6 min), and the limit of assay quantification (LLOQ) was 2 ng/mL using 50 microL of rat plasma. Rimantadine and the internal standard (amantadine) were monitored in selected ion monitoring (SIM) mode at m/z 180.2 and 152.1, respectively. The standard curve was linear over a concentration range from 2 to 750 ng/mL, and the correlation coefficients were greater than 0.999. The mean intra- and inter-day assay accuracy ranged from 100.1-105.0% to 100.3-104.0%, respectively, and the mean intra- and inter-day precision was between 1.3-2.3% and 1.8-3.0%, respectively. The developed assay method was successfully applied to a pharmacokinetic study in rats after oral administration of rimantadine hydrochloride at the dose of 20 mg/kg.  相似文献   

19.
The anthracycline Doxorubicin (DXR) is used widely for the treatment of human malignancies, and drug delivery technologies are under investigation to enhance antitumor selectivity and effectiveness. A liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method was developed to identify and quantify DXR and key metabolites in small-volume biological samples. The assay was linear over the therapeutically relevant concentration range (0.125-10,000 nM); in brain tissue, the lower limit of quantification was 0.247 nM and the sensitivity was 1.4 pg. The ability to quantify DXR and detect metabolite formation may provide insight into the toxicity and bioavailability of drug incorporated into carriers such as liposomes.  相似文献   

20.
The apolipoprotein A-I mimetic peptide D-4F is a potential therapeutical agent effective in maintaining cardiovascular health. A bioanalytical assay based on high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC/MS/MS) to quantitate the D-4F amount in rabbit plasma was developed and validated. A compound with a close structure similarity to the D-4F (only one amino acid A–V altered) was used as an internal standard. Both D-4F and the internal standard were extracted by protein precipitation using acetonitrile/0.2% Triton XL 80N. The correlation coefficient of the calibration curve was 0.9991 in the range 20–40,000 ng/mL. This assay can be used for pharmacokinetic studies of the drug. Also, it may be adjusted for the quantification of other members of apolipoprotein A-I mimetic peptide family.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号