首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A thermal comfort field study has been carried out in five cities in the humid subtropical climate zone in China. The survey was performed in naturally ventilated and air-conditioned buildings during the summer season in 2006. There were 229 occupants from 111 buildings who participated in this study and 229 questionnaire responses were collected. Thermal acceptability assessment reveals that the indoor environment in naturally ventilated buildings could not meet the 80% acceptability criteria prescribed by ASHRAE Standard 55, and people tended to feel more comfortable in air-conditioned buildings with the air-conditioned occupants voting with higher acceptability (89%) than the naturally ventilated occupants (58%). The neutral temperatures in naturally ventilated and air-conditioned buildings were 28.3°C and 27.7°C, respectively. The range of accepted temperature in naturally ventilated buildings (25.0∼31.6°C) was wider than that in air-conditioned buildings (25.1∼30.3°C), which suggests that occupants in naturally ventilated buildings seemed to be more tolerant of higher temperatures. Preferred temperatures were 27.9°C and 27.3°C in naturally ventilated and air-conditioned buildings, respectively, both of which were 0.4°C cooler than neutral temperatures. This result suggests that people of hot climates may use words like “slightly cool” to describe their preferred thermal state. The relationship between draught sensation and indoor air velocity at different temperature ranges indicates that indoor air velocity had a significant influence over the occupants’ comfort sensation, and air velocities required by occupants increased with the increasing of operative temperatures. Thus, an effective way of natural ventilation which can create the preferred higher air movement is called for. Finally, the indoor set-point temperature of 26°C or even higher in air-conditioned buildings was confirmed as making people comfortable, which supports the regulation in China that in public and office buildings the set-point temperature of air-conditioning system should not be lower than 26°C.  相似文献   

2.
Buildings are complex ecosystems that house trillions of microorganisms interacting with each other, with humans and with their environment. Understanding the ecological and evolutionary processes that determine the diversity and composition of the built environment microbiome—the community of microorganisms that live indoors—is important for understanding the relationship between building design, biodiversity and human health. In this study, we used high-throughput sequencing of the bacterial 16S rRNA gene to quantify relationships between building attributes and airborne bacterial communities at a health-care facility. We quantified airborne bacterial community structure and environmental conditions in patient rooms exposed to mechanical or window ventilation and in outdoor air. The phylogenetic diversity of airborne bacterial communities was lower indoors than outdoors, and mechanically ventilated rooms contained less diverse microbial communities than did window-ventilated rooms. Bacterial communities in indoor environments contained many taxa that are absent or rare outdoors, including taxa closely related to potential human pathogens. Building attributes, specifically the source of ventilation air, airflow rates, relative humidity and temperature, were correlated with the diversity and composition of indoor bacterial communities. The relative abundance of bacteria closely related to human pathogens was higher indoors than outdoors, and higher in rooms with lower airflow rates and lower relative humidity. The observed relationship between building design and airborne bacterial diversity suggests that we can manage indoor environments, altering through building design and operation the community of microbial species that potentially colonize the human microbiome during our time indoors.  相似文献   

3.
Jagjit Singh 《Aerobiologia》1996,12(2):121-127
In this special report, the possible causes of indoor air pollution and its impact on the health, comfort and productivity of the building occupant are discussed. The causes and symptoms of sick building syndrome, allergy and environmental illnesses and building related illnesses are discussed in the context of building environments. The remediation and prevention measures examine the solution to the problems caused by indoor air pollution in buildings.  相似文献   

4.
Jagjit Singh 《Aerobiologia》1996,12(1):121-127
In this special report, the possible causes of indoor air pollution and its impact on the health, comfort and productivity of the building occupant are discussed. The causes and symptoms of sick building syndrome, allergy and environmental-illnesses and building related illnesses are discussed in the context of building environments. The remediation and prevention measures examine the solution to the problems caused by indoor air pollution in buildings  相似文献   

5.
Indoor climate and air quality   总被引:2,自引:0,他引:2  
 In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants’ clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of ”sick building syndrome”. Received: 27 October 1997 / Accepted 26 November 1997  相似文献   

6.
Twelve fungi were isolated and identified from air-conditioned rooms. Of the 12, 7 were species of Aspergillus, viz. A. niger, A. oryzae, A. fumigatus, A. terreus, A. nidulans, A. versicolor and A. parasiticus. Other fungi were Penicillium citrinum, Fusarium oxysporum, Trichoderma viride, Neurospora crassa and Alternaria alternata. A. niger was present in 80% of the locations. Some of the fungi isolated in this study could be opportunistic fungal pathogens, like A. fumigatus, A. niger and Penicillium citrinum, and were found to be allergenic. Results of this study indicate that air-conditioned rooms could be reservoirs of fungi and may cause allergic problems or infections in healthy or immunocompromised individuals living in these environments.  相似文献   

7.
Problems caused by indoor microbial, especially fungal growth, have been further exaggerated by the increased incidence of water intrusions, condensation from air-conditioning system, and other factors. While fungal contamination in a building can be one of the indicators of indoor air quality (IAQ), air quality assessment and remediation should be considered as important and should be carried out systematically. This study reports the incidence and remediation of an excessive fungal growth in a building in Universiti Sains Malaysia (USM), Pulau Pinang, Malaysia. Acting on an official report by the building owner and occupants, an immediate walk-through investigation was carried out between June and December 2009. A thorough sampling comprising swab and spore impactor techniques showed that the colony-forming unit per cubic meter of air (CFU/m3) levels were far above those in the guidelines of most developed countries. Thus, the building was declared a ‘sick building’ and closed to the publics. However, through immediate action with recommended methods to overcome the problem, the premise has been pronounced safe. This is a good example of successful teamwork that involved a continuous investigation by a team of experts along with comprehensive action taken by the occupants and other authorities responsible for the building.  相似文献   

8.

Objective

To assess health risks associated with inhalation exposure to formaldehyde and benzene mainly emitted from building and decoration materials in newly remodeled indoor spaces in Beijing.

Methods

We tested the formaldehyde and benzene concentrations in indoor air of 410 dwellings and 451 offices remodeled within the past year, in which the occupants had health concerns about indoor air quality. To assess non-carcinogenic health risks, we compared the data to the health guidelines in China and USA, respectively. To assess carcinogenic health risks, we first modeled indoor personal exposure to formaldehyde and benzene using the concentration data, and then estimated the associated cancer risks by multiplying the indoor personal exposure by the Inhalation Unit Risk values (IURs) provided by the U.S. EPA Integrated Risk Information System (U.S. EPA IRIS) and the California Office of Environmental Health Hazard Assessment (OEHHA), respectively.

Results

(1) The indoor formaldehyde concentrations of 85% dwellings and 67% offices were above the acute Reference Exposure Level (REL) recommended by the OEHHA and the concentrations of all tested buildings were above the chronic REL recommended by the OEHHA; (2) The indoor benzene concentrations of 12% dwellings and 32% offices exceeded the reference concentration (RfC) recommended by the U.S. EPA IRIS; (3) The median cancer risks from indoor exposure to formaldehyde and benzene were 1,150 and 106 per million (based on U.S. EPA IRIS IURs), 531 and 394 per million (based on OEHHA IURs).

Conclusions

In the tested buildings, formaldehyde exposure may pose acute and chronic non-carcinogenic health risks to the occupants, whereas benzene exposure may pose chronic non-carcinogenic risks to the occupants. Exposure to both compounds is associated with significant carcinogenic risks. Improvement in ventilation, establishment of volatile organic compounds (VOCs) emission labeling systems for decorating and refurbishing materials are recommended to reduce indoor VOCs exposure.  相似文献   

9.
Summary Permanence within a building is frequently associated with health complaints identified as several clinical syndromes. Contamination by bacterial products may play a predominant role in some of these clinical syndromes, like building-related asthma, humidifier fever or the sick building syndrome (SBS). Indeed, on one side, in air-conditioned systems, the physical conditions are optimal for microbial development and for endotoxin production (from the membrane of gram negative bacteria) and on the other side, inhalation of endotoxin has demonstrated the onset of a bronchial obstruction and an increase in airway reactivity leading to non specific chest complaints. Nevertheless, this hypothesis on aetiopathogenesis of SBS remains to be demonstrated by environmental and lung functional studies on the building site.  相似文献   

10.
The concentration of airborne fungal spores and bacteria as related to room temperature, humidity and occupancy levels within a library building in Singapore was determined. Measurement of indoor air quality with respect to microorganisms is of particular importance in tropical environments due to the extensive use of air‐conditioning systems and the potential implications for human health. This study has revealed a number of interesting relationships between the concentrations of fungal spores and bacteria in relation to both environmental and human factors. The levels of fungal spores measured in the indoor environment were approximately fifty times lower than those measured outside, probably because of the lowered humidity caused by air‐conditioning in the indoor environment. The variation in fungal spore concentration in the outdoor environment is likely to be due to the diurnal periodicity of spore release and the response to environmental factors such as light temperature and humidity. The indoor concentration of fungal spores in air was not clearly correlated to concentrations measured in air outside of the library building and remained relatively constant, unaffected by the difference in the numbers of occupants in the library. In contrast, the indoor concentrations of bacteria in air were approximately ten times higher than those measured outdoors, indicating a signficant internal source of bacteria. The elevated levels of indoor bacteria were primarily attributed to the number of library occupants. Increased human shedding of skin cells, ejection of microorganisms and particulates from the respiratory tract, and the transport of bacteria on suspended dust particles from floor surfaces probably accounts for the strong positive correlation between occupancy levels and the concentration of bacteria in internal air.  相似文献   

11.

1. 1. A comprehensive study was made to establish evaluation methods for better office environments.

2. 2. In our study, measurements of thermal, acoustic, lighting, airflow and air quality conditions in indoor environments were made as well as questionnaire to the occupants on the evaluations of indoor environments and the feeling of fatigue.

3. 3. We also made an attempt to rate the evaluation value based on concepts and standards to evaluate totally office environments in a view point of “the office environments where people can work healthy and vigorously”. The evaluation values were called IAQ-index.

Author Keywords: Office environments; measurements; questionnaire survey; comprehensive evaluation method  相似文献   


12.
Zhou R  Li S  Zhou Y  Haug A 《Mutation research》2000,465(1-2):191-200
Environmental tobacco smoke (ETS) is a major source for indoor air pollution. Although ETS-caused indoor air pollution has been well studied in the developed countries, few studies have examined ETS indoor air pollution in China, which currently has the largest population of tobacco smokers. In this study, respirable-particulate (RP) from ETS-contaminated (RP-ETS) indoor air was collected and measured in 5 different indoor environments during the winter in the northwestern Liaoning Province, China. The extractable portion of RP-ETS (ERP-ETS) was obtained by dichloromethane extraction and used in the Salmonella mutagenicity assay in the presence of S9 using strains TA98, TA100, and TA1538. The percentage of RP-ETS attributable to ETS (ETS-RP) and the percentage of ERP-ETS attributable to ETS (ETS-ERP) were estimated by measuring the concentration of solanesol, an ETS marker. Comparative results in 5 different indoor environments were: (1) the concentration of RP-ETS ranged from 197.3 to 1227.6 microg/m(3) and approximately 64.7 to 92. 0% of the RP-ETS originated from ETS; (2) the concentration of ERP-ETS ranged 88.8 to 601.5 microg/m(3) and approximately 83.1 to 95.4% of the ERP-ETS originated from ETS; (3) the mutagenic potency (revertants/m(3)) of ERP-ETS ranged from 60.4 to 595.5 for TA98, from 33.7 to 312.8 for TA100, and from 49.7 to 475.2 for TA1538. The data indicate that the extent of ETS pollution and the potential health hazards of ETS to humans in the five indoor environments are in the following increasing order: rural bedrooms, urban living rooms, office rooms, restaurants, and passenger cars in that area.  相似文献   

13.
Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health.  相似文献   

14.
Significant media and regulatory attention has been given to hazardous waste sites and to the remediation of such sites to protect nearby building occupants. Soil vapor intrusion (SVI) can be a major factor contributing to increased occupant expo sure to chemicals. However, there are many possible sources of indoor air pollution, thus complicating routine assessments. The intent of this paper is to provide an overview of the state of understanding related to chemical fate in the indoor environment. A generalized model is presented in the form of an ordinary differential equation that includes several terms that are not commonly accounted for in models involving the effects of SVI in indoor air. In addition to soil vapor intrusion several other sources of indoor contamination are described. Typical air exchange rates for residential dwellings are presented. Finally, recent findings related to the sorptive interactions between indoor air pollutants and indoor materials, as well as homogeneous and heterogeneous chemical reactions that can affect indoor air pollutants are described.  相似文献   

15.
Stachybotrys occurring in mouldy indoor environments is associated with the so called “sick building syndrome” in humans or cases of idiopathic pulmonary hemorrhages. Samples of mouldy materials from indoor environments (n=15) were analysed for the occurrence of this fungus and its secondary metabolites by a sensitive LC-MS/MS method. In four samples,Stachybotrys and macrocyclic trichothecenes have been detected. Maximum values for Satratoxin G and H in wallpaper were determined with 9.7 μg/cm2 and 12.0 μg/cm2, respectively.  相似文献   

16.
Samples of building materials visibly contaminated with moisture-related fungi (drywall, fiberglass, wallpaper, wood) were tested with indirect (FFL) and direct (MTT) cytotoxicity screening tests that are particularly sensitive toStachybotrys chartarum toxins. In addition, microscopic, chemical, immunochemical (Roridin A enzyme immunoassay) and mycological culture analyses were performed. In all cases in which building occupants had reported verifiable skin, mucous membrane, respiratory, central nervous system or neuropsychological abnormalities, cytotoxicity was identified. Results of a cytotoxicity screening test of field samples, such as the direct MTT test method, will give investigators of health problems related to indoor air quality problems important toxicity information.  相似文献   

17.
Human occupants are an important source of microbes in indoor environments. In this study, we used DNA sequencing of filter samples to assess the fungal and bacterial composition of air in an environmental chamber under different levels of occupancy, activity, and exposed or covered carpeting. In this office-like, mechanically ventilated environment, results showed a strong influence of outdoor-derived particles, with the indoor microbial composition tracking that of outdoor air for the 2-hour sampling periods. The number of occupants and their activity played a significant but smaller role influencing the composition of indoor bioaerosols. Human-associated taxa were observed but were not particularly abundant, except in the case of one fungus that appeared to be transported into the chamber on the clothing of a study participant. Overall, this study revealed a smaller signature of human body-associated taxa than had been expected based on recent studies of indoor microbiomes, suggesting that occupants may not exert a strong influence on bioaerosol microbial composition in a space that, like many offices, is well ventilated with air that is moderately filtered and moderately occupied.  相似文献   

18.
- Part 1: Characterisation factors (DOI: http://dx.doi.org/10.1065/lca2004.12.194.1) Part 2: Damage scores (DOI: http://dx.doi.org/10.1065/lca2004.12.194.2) - Preamble. In this series of two papers, a methodology to calculate damages to human health caused by indoor emissions from building materials is presented and applied. Part 1 presents the theoretical foundation of the indoor emission methodology developed, as well as characterisation factors calculated for 36 organic compounds, radon and gamma radiation. Part 2 calculates damage scores of building materials with the characterisation factors presented in part 1. The relevancy of including indoor air emission in the full damage scores at a material level and a dwelling level is also quantified and discussed. Goal, Scope and Background In industrialized countries such as the Netherlands, the concentration of pollutants originating from building materials in the indoor environment has shown an increasing trend during the last decades due to improved isolation and decreased ventilation of dwellings. These pollutants may give rise to negative impacts on human health, ranging from irritation to tumours. However, such negative impacts on health are not included in current life cycle assessments of dwellings. In this study, damages to the health of occupants caused by a number of organic compounds and by radioactivity emitted by building materials, including those due to indoor exposure, have been calculated for a number of categories of common building materials. The total damage to human health due to emissions occurring in the use phase of the Dutch reference dwelling is compared with the total damage to human health associated with the rest of the life cycle of the same dwelling. Methods Human health damage scores per kilogram of building material for compartments of the Dutch reference dwelling have been calculated using the methodology described in part I of this research. This methodology includes the calculation of the fate, effect and damage factors, based on disability adjusted life years (DALYs), and has been applied assuming average concentrations of pollutants in building materials. Damage scores for health impacts of exposure to pollutants emitted during the production and the disposal phase of the same building materials were calculated using standard LCIA methodology. Results and Discussion Human health damage scores due to emissions of pollutants occurring in the use phase of building materials applied at the first or second floor are up to 20 times lower or higher than the corresponding damage scores associated with the rest of the life cycle of the same building materials. The damage scores due to emissions occurring in the use phase of building materials applied in the crawlspace are up to 105 times lower than those of building materials applied in the other compartments. The total damage to human health due to emissions occurring in the use phase of the Dutch reference dwelling has the same order of magnitude as the total damage to human health associated with the rest of the life cycle of the same dwelling. At a dwelling level, radon and gamma radiation are dominant in the human health damage score among the pollutants studied. Conclusion Health damages due to indoor exposure to contaminants emitted by building materials cannot be neglected for several materials when compared with damage scores associated with the rest of the life cycle of the same building materials. Indoor exposure to pollutants emitted by building materials should be included in the life cycle assessment of dwellings in order to make the assessment better reflect full impact of the life cycle.  相似文献   

19.
The occurrence of Stachybotrys chartarum in indoor environments has been linked to adverse health effects as well as few cases of pulmonary haemorrhages in humans. Although the highly toxic secondary metabolites of this fungus, like satratoxin G and H, were frequently claimed with outbreaks of such diseases, these toxins have hardly been identified in the air of naturally contaminated indoor environments. Herein, a case of a LC-MS/MS-confirmed occurrence of airborne S. chartarum-toxins in a water-damaged dwelling is reported. Satratoxin G (0.25 ng/m(3)) and satratoxin H (0.43 ng/m(3)) were detected. This provides further evidence that Stachybotrys-toxins can be transferred from mouldy indoor materials into air, which could be a factor in the aetiology of health symptoms related to the sick building syndrome.  相似文献   

20.
Summary Microbiologic air contamination plays, among other factors, a role in building associated illnesses i.e., hypersensitivity diseases, bacterial and fungal infections, sick building syndrome. Airborne microorganisms are separated into obligate parasites, such as the viruses and a few bacteria, that must find a suitable host within a brief period, and facultative saprophytes that are usually found in living hosts an/or in the environment (primary and opportunistic pathogens). The etiology of hypersensitivity diseases is biological allergens such as those from fungi (moulds), bacteria,Amoebae and other protozoa. Humidifiers, cold air coils and porous material belonging to mechanical ventilation system can all be reservoirs/amplifiers/disseminators for living organisms, allergens or other microbial products. Legionella is an ubiquitous bacterium in the environment. Bioaerosols from potable water and air conditioning components appear to be the source of most human infections with this organism (Legionnaire's disease and Pontiac fever).Aspergillus fumigatus has a risk of penetration indoor but affects only people with seriously impaired immunity. Responsibility of airborne moulds, bacterial endotoxins or mycotoxins in sick building syndrome complaints is unclear. Design, operation and maintenance of ventilation systems are fundamental to assure well-being to building occupants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号