Aims

To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA)

Methods

MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in this study.

Results

17 patients fulfilled the inclusion criterion. In all 17 patients IOP measurements were performed with RT (34 eyes) and ORA (33 eyes), while PAT measurement was possible in only 12 (24 eyes) patients. The RT, corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) differed relevantly from IOP assessed with PAT. Corneal clouding in MPS patients correlated positively with PAT, RT and IOPg (r = 0.3, 0.5, and 0.5 respectively), but not with IOPcc (r = 0.07). The MPS-related corneal clouding correlated positively with biomechanical corneal parameters assessed with ORA: corneal hysteresis (r = 0.77) and corneal resistance factor (r = 0.77) either.

Conclusions

RT and ORA measurements were tolerated better than applanation tonometry in MPS patients. IOP measurements assessed with RT and ORA differed relevantly from PAT. Corneal-compensated IOP assessed with ORA seems to be less affected by the MPS-related corneal clouding than applanation or rebound tonometry. RT and ORA measurements should be preferred for IOP assessment in patients with MPS.  相似文献   

2.

Purpose

To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups.

Methods

Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes.

Results

The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05).

Conclusions

CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.  相似文献   

3.

Purpose

In eyes with a preoperative plano refractive cylinder, it would appear that there is no rationale for astigmatic treatment. The aim of this retrospective, cross-sectional data analysis was to determine the amount of topographic astigmatism in refractive plano eyes that results in reduced efficacy after myopic laser in situ keratomileusis (LASIK).

Methods

This study included 267 eyes from 267 consecutive myopic patients with a refractive plano cylinder. Receiver operating characteristic analysis was used to find the cut-off values of preoperative ocular residual astigmatism (= topographic astigmatism) that can best discriminate between groups of efficacy and safety indices in preoperative plano refractive cylinder eyes.

Results

Preoperative ocular residual astigmatism (ORA) (or topographic astigmatism) of ≤0.9 diopters (D) resulted in an efficacy index of at least 0.8 statistically significantly more frequently than eyes with a preoperative ORA of >0.9 D. Eyes with a high ORA preoperatively also had a high ORA postoperatively. Regression analysis showed that each diopter of preoperative ORA reduced efficacy by 0.07.

Conclusion

A preoperative corneal astigmatism of ≥0.9 D could (partially) be taken into account in the LASIK design, even if the subjective refractive astigmatism is neutral.  相似文献   

4.

Purpose

To investigate the effects of lenticule creation and subsequent corneal lenticule extraction on corneal deformation parameters during small incision lenticule extraction (SMILE) procedure.

Materials and Methods

In this prospective study, 18 eyes of 10 patients (27.90±7.11 years, −5.64±2.45 diopters) scheduled for SMILE procedure were enrolled. Changes in the corneal deformation parameters, including deformation amplitude (DA), applanation time(AT1 and AT2), applanation length(AL1 and AL2), corneal velocity(CV1 and CV2), peak distance(P.Dist.), radius and intraocular pressure values were measured preoperatively, immediately after lenticule creation and subsequent to corneal lenticule extraction in all eyes with the Corvis Scheimpflug Technology (Corvis ST, OCULUS, Wetzlar, Germany). Repeated measures analysis of variance (ANOVA) with bonferroni-adjusted post hoc comparisons was performed to investigate changes following each step of the procedure.

Results

All surgical procedures were uneventful. A significant difference was detected among the three time points (pre-operation, post-lenticule creation and post lenticule extraction) for AT1 (P<0.001), AT2 (P = 0.001), DA(P<0.001), and IOP(P = 0.002). Bonferroni-adjusted post hoc comparisons indicated that there was no significant change in AT1, AT2, DA, or IOP after lenticule creation (post hoc P>0.05), but there was a significant change in these parameters following subsequent corneal lenticule extraction (post hoc P<0.01), when compared to values obtained pre-operatively. The scheimpflug camera of the Corvis ST demonstrated the intralamellar small gas bubbles formed from the vaporisation of tissue after lenticule creation and a gray zone was observed between the cap and the residual stromal bed after lenticule extraction.

Conclusions

There is a significant change in corneal deformation parameters following SMILE procedure. The changes may be caused predominantly by stromal lenticule extraction, while lenticule creation with femtosecond laser may not have an obvious effect on corneal deformation properties.  相似文献   

5.

Purpose

To evaluate intraocular lens (IOL) tilt and decentration by anterior segment optical coherence tomography (AS-OCT) using 3-dimensional (3D) reconstruction method.

Design

Prospective observational case series.

Participants

Thirty-nine patients (39 eyes) were included.

Methods

The IOL positions of all eyes were examined by AS-OCT. Images were obtained in 4 axes (0–180 degrees, 45–225 degrees, 90–270 degrees, and 135–315 degrees) using the quadrant-scan model. The cross-sectional images were analyzed with MATLAB software.

Main Outcome Measures

The angle (θ) between the reference pupillary plane and the IOL plane, the distances between the center points of the pupil circle and the IOL on the x-axis (dx) and y-axis (dy) and the spatial distance (ds) were calculated after 3D-reconstruction.

Results

The mean angle (θ) between the pupillary plane and the IOL plane was 2.94±0.99 degrees. The mean IOL decentration of dx and dy was 0.32±0.26 mm and 0.40±0.27 mm, respectively. The ds of the IOL decentration was 0.56±0.31 mm. There was no significant correlation between the ocular residual astigmatism (ORA) and the tilted angle or the decentration distance. There was a significant correlation between the ORA and total astigmatism (r = 0.742, P<0.001). There was no significant correlation between the postoperative best corrected visual acuity (BCVA) and the ORA (r = 0.156; P = 0.344), total astigmatism (r = 0.012; P = 0.942), tilted angle (θ; r = 0.172; P = 0.295) or decentration distance (dx: r = 0.191, P = 0.244; dy: r = 0.253, P = 0.121; ds: r = 0.298, P = 0.065).

Conclusions

AS-OCT can be used as an alternative for the analysis of IOL tilt and decentration using 3D-reconstruction.  相似文献   

6.

Purpose

A lack of fatigue-related muscle contractile property changes at time of perceived physical exhaustion and greater central than peripheral fatigue detected by twitch interpolation technique have recently been reported in cancer survivors with fatigue symptoms. Based on these observations, it was hypothesized that compared to healthy people, myoelectrical manifestation of fatigue in the performing muscles would be less significant in these individuals while sustaining a prolonged motor task to self-perceived exhaustion (SPE) since their central fatigue was more prominent. The purpose of this study was to test this hypothesis by examining electromyographic (EMG) signal changes during fatiguing muscle performance.

Methods

Twelve individuals who had advanced solid cancer and cancer-related fatigue (CRF), and 12 age- and gender-matched healthy controls performed a sustained elbow flexion at 30% maximal voluntary contraction till SPE. Amplitude and mean power frequency (MPF) of EMG signals of the biceps brachii, brachioradialis, and triceps brachii muscles were evaluated when the individuals experienced minimal, moderate, and severe fatigue.

Results

CRF patients perceived physical “exhaustion” significantly sooner than the controls. The myoelectrical manifestation of muscular fatigue assessed by EMG amplitude and MPF was less significant in CRF than controls. The lower MPF even at minimal fatigue stage in CRF may indicate pathophysiologic condition of the muscle.

Conclusions

CRF patients experience less myoelectrical manifestation of muscle fatigue than healthy individuals near the time of SPE. The data suggest that central nervous system fatigue plays a more important role in limiting endurance-type of motor performance in patients with CRF.  相似文献   

7.

Objective

To investigate whether fatigue induced by an intermittent motor task in patients with cancer-related fatigue (CRF) is more central or peripheral.

Methods

Ten patients with CRF who were off chemo and radiation therapies and 14 age-matched healthy controls were enrolled. Participants completed a Brief Fatigue Inventory (BFI) and performed a fatigue task consisting of intermittent elbow-flexion contractions at submaximal (40% maximal voluntary contraction) intensity till self-perceived exhaustion. Twitch force was elicited by an electrical stimulation applied to the biceps brachii muscle. The relative degree of peripheral (muscle) vs. central contribution to fatigue induced by the intermittent motor task (IMT) was assessed using twitch force ratio (TFratio) defined as post IMT twitch force to pre IMT twitch force. The total number of trials (intermittent contractions) and total duration of all trials performed by each subject were also quantified.

Results

BFI scores were higher (p<0.001) in CRF than controls, indicating greater feeling of fatigue in CRF patients than controls. A significantly smaller number of trials and shorter total duration of the trials (p<0.05) were observed in CRF than control participants. The TFratio (0.81±0.05) in CRF was higher (p<0.05) compared with that of controls (0.62±0.05), suggesting CRF patients experienced a significantly lower degree of muscle (peripheral) fatigue at the time of perceived exhaustion.

Conclusion

Consistent with prior findings for fatigue under submaximal sustained contraction, our results indicate that motor fatigue in CRF is more of central than peripheral origin during IMT. Significant central fatigue in CRF patients limits their ability to prolong motor performance.  相似文献   

8.

Introduction

The design of a globally effective vaccine rests on the identification of epitopes capable of eliciting effective cytotoxic T lymphocyte (CTL) responses across multiple HIV clades in different populations. This study aims to discern the effect of HLA polymorphisms and the cross-clade reactivity or clade-specificity of epitopes in Thailand where HIV-1 CRF01_AE is circulating.

Materials and Methods

14 peptides based on consensus HIV-1 CRF01_AE amino acid sequences were designed for use in IFN-γ ELISpot assays and 51Cr release assays among 66 HIV-1 CRF01_AE-infected Thai patients. For ELISpot responders carrying HLA alleles currently unknown to restrict CRF01_AE epitopes, in silico epitope-HLA prediction was performed.

Results

29/66 (43.9%) patients recognized at least one peptide. In total 79 responses were seen against all 14 peptides. 28/79 (35.4%) of the responses were in patients with HLA alleles previously reported to restrict CRF01_AE epitopes, 24/79 (30.4%) responses were in individuals with HLA alleles previously reported to restrict epitopes of HIV clades other than CRF01_AE, and the remaining 27/79 (34.2%) responses were not associated with HLA alleles previously known to restrict HIV epitopes. In silico epitope prediction detected 19 novel, epitope-HLA combinations, and 11/19 (57.9%) were associated with HLA-C alleles. We further confirmed a novel HLA restriction of a previously identified HIV-1 Gag epitope [p24122–130: PPIPVGDIY (PY9)] by HLA-B*40:01 with a standard 51Cr release assay.

Discussion

CTL recognition sites in HIV-1 Gag were similar among different clades but the HLA restriction differed in Thai patients. This disparity in HLA restriction along different populations illustrated the importance of clade- and population-specific HLA analysis prior to CTL vaccine design.  相似文献   

9.

Background

Precise measurement of the QT interval is often hampered by difficulty determining the end of the low amplitude T wave. Root mean square electrocardiography (RMS ECG) provides a novel alternative measure of ventricular repolarization. Experimental data have shown that the interval between the RMS ECG QRS and T wave peaks (RTPK) closely reflects the mean ventricular action potential duration while the RMS T wave width (TW) tracks the dispersion of repolarization timing. Here, we tested the precision of RMS ECG to assess ventricular repolarization in humans in the setting of drug-induced and congenital Long QT Syndrome (LQTS).

Methods

RMS ECG signals were derived from high-resolution 24 hour Holter monitor recordings from 68 subjects after receiving placebo and moxifloxacin and from standard 12 lead ECGs obtained in 97 subjects with LQTS and 97 age- and sex-matched controls. RTPK, QTRMS and RMS TW intervals were automatically measured using custom software and compared to traditional QT measures using lead II.

Results

All measures of repolarization were prolonged during moxifloxacin administration and in LQTS subjects, but the variance of RMS intervals was significantly smaller than traditional lead II measurements. TW was prolonged during moxifloxacin and in subjects with LQT-2, but not LQT-1 or LQT-3.

Conclusion

These data validate the application of RMS ECG for the detection of drug-induced and congenital LQTS. RMS ECG measurements are more precise than the current standard of care lead II measurements.  相似文献   

10.
11.

Purpose

To evaluate one-step topography-guided transepithelial ablation in the treatment of low to moderate myopic astigmatism using a 1KHz excimer laser.

Methods

Retrospective study of 117 consecutive eyes available for evaluation 12 months after surgery. Pre- and post-operative visual and refractive data as well as post-operative pain and haze were analyzed. A novel technique integrating custom refractive- and epithelial- ablation in a single uninterrupted procedure was used.

Results

The mean pre-operative spherical equivalent (SE) and the mean cylinder were: –3.22 diopters (D) ±1.54 (SD) (range –0.63 to –7.25 D) and –0.77 D ±0.65 (range 0 to –4.50 D), respectively. At 12 months after surgery: no eyes lost ≥2 lines of corrected distant visual acuity (CDVA). Safety and efficacy indexes were 1.27 and 1.09, respectively. Uncorrected distant visual acuity (UDVA) was ≥20/20 in 96.6% of the eyes. Manifest refraction spherical equivalent was within ±0.5 D of the desired refraction in 93.2% of the eyes. Average root mean square (RMS) wavefront error measured at central 6 mm, increased from 0.38 pre-operatively to 0.47 µm post-operatively. Refractive stability was achieved and sustained 1 month after surgery. No visually significant haze was registered during the observation period. Post-operative pain was reported in 4.5% of patients.

Conclusions

One-step transepithelial topography-guided treatment for low to moderate myopia and astigmatism performed with a 1 KHz laser, provided safe, effective, predictable and stable results with low pain and no visually significant haze.  相似文献   

12.
Wang PG  Gong J  Wang SQ  Talbott EO  Zhang B  He QQ 《PloS one》2011,6(11):e27896

Backgrounds/Objectives

Cardiorespiratory fitness (CRF) and body fat play an important role in elevated risk for cardiovascular disease (CVD). However, the combined effects of CRF and obesity on metabolic health in Chinese children are unclear. The purpose of this study was to investigate the independent and combined associations between body fat, CRF, and CVD risk in Chinese schoolchildren.

Methods

The study subjects comprised 676 schoolchildren (392 boys and 284 girls, aged 9.6±0.7 yrs old) in Wuhan, China. Their body mass index (BMI), waist circumference (WC), CRF, blood pressure (BP), lipids, glucose, and pubertal status were assessed. Children were categorized into different groups based on their BMI, WC, and CRF using Chinese obesity cut-off points and CRF sex-specific median points. Metabolic Risk Score (MRS) was computed based on the standardized scores of BP, lipids, and glucose.

Results

Multiple linear regression models showed that, in the separate models, body fat was positively associated with MRS while CRF was inversely associated with MRS (p<0.001). However, when assessed simultaneously, only body fat had a significant association with MRS (p<0.001). In general, low-fit children had a lower MRS compared to their counterparts, and a significant difference between the two extreme groups was observed (low CRF and high fat vs. high CRF and low fat, p<0.001).

Conclusions

These findings suggest that both body fat and CRF should be considered when interpreting CVD risk in Chinese children, while body fat may be correlated with CVD risk more than CRF.  相似文献   

13.

Purpose

To explore ocular changes in healthy people after exercise.

Methods

Twenty five volunteers underwent exercise for 15 minutes on a treadmill. Measurements of choroidal thickness, intraocular pressure (IOP), ocular biometry, and blood pressure were taken before and after exercise. Enhanced Depth Imaging optical coherence tomography (EDI-OCT) was used to measure choroidal thickness at the fovea. Intraocular pressure (IOP) was measured by Goldmann applanation tonometry. Ocular biometric measures were collected using A scan ultrasound. Blood pressure was measured concurrently with the acquisition of the scans.

Results

Twenty five volunteers (25 eyes) with a mean age of 25.44±3.25 years were measured. There was a significant increase in systolic and diastolic pressure after exercise (P<0.05). The IOP showed a significant decrease after exercise (P<0.05). However there was no significant difference in the mean choroidal thickness, ocular axial length, anterior chamber depth, lens thickness, or vitreous length before and after exercise measurements (P>0.05).

Conclusion

There was a significant decrease in IOP from exercise without a change in choroidal thickness and ocular biometric measures. IOP and choroidal thickness were not correlated, suggesting that the IOP decrease from exercise is not due to changes in choridal thickness.  相似文献   

14.

Purpose

To compare the results of combined and consecutive surgeries to treat proliferative diabetic retinopathy and cataract.

Methods

Retrospective comparative study. Forty-one patients with proliferative diabetic retinopathy (PDR) were enrolled. Twenty-nine eyes for the combined surgery group and twelve eyes for the sequential group were included. All surgeries were performed by one surgeon. Phacoemulsification was performed using a clear cornea incision. The vitrectomy was performed using a 20-gauge vitreous cutter.

Results

The best corrected visual acuity (BCVA) and intra- and post-operative complications were the main outcome measures. In the combined surgery group, the BCVA increased in 18 (62.1%) eyes, while eight (27.6%) eyes remained stable and three (10.3%) eyes decreased. Postoperative complications included fibrinous exudation in nine eyes, macular edema in three eyes and vitreous hemorrhage in three eyes. In the sequential surgery group, the BCVA increased in seven (58.3%) eyes, remained the same in four (33.3%) eyes and was reduced in one (8.3%) eye. Postoperative complications included macular edema in two eyes, neovascular glaucoma in two eyes and vitreous hemorrhage in one eye.

Conclusions

Both combined and sequential surgeries are safe and effective for treating PDR and cataracts. The combined surgery had a higher incidence of fibrinous exudation.  相似文献   

15.

Objective

To investigate the HIV-1 molecular epidemiology among newly diagnosed HIV-1 infected persons living in the Jilin province of northeastern China.

Methods

Plasma samples from 189 newly diagnosed HIV-1 infected patients were collected between June 2010 and August 2011 from all nine cities of Jilin province. HIV-1 nucleotide sequences of gag P17–P24 and env C2–C4 gene regions were amplified using a multiplex RT-PCR method and sequenced. Phylogenetic and recombination analyses were used to determine the HIV-1 genotypes.

Results

Based on all sequences generated, the subtype/CFR distribution was as follows: CRF01_AE (58.1%), CRF07_BC (13.2%), subtype B’ (13.2%), recombinant viruses (8.1%), subtype B (3.7%), CRF02_AG (2.9%), subtype C (0.7%). In addition to finding CRF01_AE strains from previously reported transmission clusters 1, 4 and 5, a new transmission cluster was described within the CRF07_BC radiation. Among 11 different recombinants identified, 10 contained portions of gene regions from the CRF01_AE lineage. CRF02_AG was found to form a transmission cluster of 4 in local Jilin residents.

Conclusions

Our study presents a molecular epidemiologic investigation describing the complex structure of HIV-1 strains co-circulating in Jilin province. The results highlight the critical importance of continuous monitoring of HIV-infections, along with detailed socio-demographic data, in order to design appropriate prevention measures to limit the spread of new HIV infections.  相似文献   

16.

Background

Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens.

Methods

We generated a panel of 43 recombinantly expressed virus-like particles (VLPs), containing the structural Gag proteins of HIV-1 subtypes A-H and circulating recombinant forms (CRF) CRF01_AE, CRF02_AG, CRF12_BF, CRF20_BG and group O. Eleven 4th generation antigen/antibody tests and five antigen-only tests were evaluated for their ability to detect VLPs diluted in human plasma to p24 concentrations equivalent to 50, 10 and 2 IU/ml of the WHO p24 standard. Three tests were also evaluated for their ability to detect p24 after heat-denaturation for immune-complex disruption, a pre-requisite for ultrasensitive p24 detection.

Results

Our VLP panel exhibited an average intra-clade p24 diversity of 6.7%. Among the 4th generation tests, the Abbott Architect and Siemens Enzygnost Integral 4 had the highest sensitivity of 97.7% and 93%, respectively. Alere Determine Combo and BioRad Access were least sensitive with 10.1% and 40.3%, respectively. Antigen-only tests were slightly more sensitive than combination tests. Almost all tests detected the WHO HIV-1 p24 standard at a concentration of 2 IU/ml, but their ability to detect this input for different subtypes varied greatly. Heat-treatment lowered overall detectability of HIV-1 p24 in two of the three tests, but only few VLPs had a more than 3-fold loss in p24 detection.

Conclusions

The HIV-1 Gag subtype panel has a broad diversity and proved useful for a standardised evaluation of the detection limit and breadth of subtype detection of p24 antigen-detecting tests. Several tests exhibited problems, particularly with non-B subtypes.  相似文献   

17.

Background

Obeche wood dust is a known cause of occupational asthma where an IgE-mediated mechanism has been demonstrated.

Objective

To characterize the allergenic profile of obeche wood dust and evaluate the reactivity of the proteins by in vitro, ex vivo and in vivo assays in carpenters with confirmed rhinitis and/or asthma

Materials and methods

An in-house obeche extract was obtained, and two IgE binding bands were purified (24 and 12 kDa) and sequenced by N-terminal identity. Specific IgE and IgG, basophil activation tests and skin prick tests (SPTs) were performed with whole extract and purified proteins. CCD binding was analyzed by ELISA inhibition studies.

Results

Sixty-two subjects participated: 12 with confirmed occupational asthma/rhinitis (ORA+), 40 asymptomatic exposed (ORA−), and 10 controls. Of the confirmed subjects, 83% had a positive SPT to obeche. There was a 100% recognition by ELISA in symptomatic subjects vs. 30% and 10% in asymptomatic exposed subjects and controls respectively (p<0.05). Two new proteins were purified, a 24 kDa protein identified as a putative thaumatin-like protein and a 12 kDa gamma-expansin. Both showed allergenic activity in vitro, with the putative thaumatin being the most active, with 92% recognition by ELISA and 100% by basophil activation test in ORA+ subjects. Cross-reactivity due to CCD was ruled out in 82% of cases.

Conclusions

Two proteins of obeche wood were identified and were recognized by a high percentage of symptomatic subjects and by a small proportion of asymptomatic exposed subjects. Further studies are required to evaluate cross reactivity with other plant allergens.  相似文献   

18.

Background and aims

Loss of the endotoxin tolerance of intestinal epithelium contributes to a number of intestinal diseases. The etiology is not clear. Psychological stress is proposed to compromise the intestinal barrier function. The present study aims to elucidate the role of the stress-derived corticotropin releasing factor (CRF) in breaching the established intestinal epithelial endotoxin tolerance.

Methods

Epithelial cells of HT-29, T84 and MDCK were exposed to lipopolysaccharide to induce the endotoxin tolerance; the cells were then stimulated with CRF. The epithelial barrier function was determined using as indicators of the endotoxin tolerant status. A water-avoid stress mouse model was employed to test the role of CRF in breaching the established endotoxin tolerance in the intestine.

Results

The established endotoxin tolerance in the epithelial cell monolayers was broken down by a sequent exposure to CRF and LPS manifesting a marked drop of the transepithelial resistance (TER) and an increase in the permeability to a macromolecular tracer, horseradish peroxidase (HRP). The exposure to CRF also increased the expression of Cldn2 in the epithelial cells, which could be mimicked by over expression of TLR4 in epithelial cells. Over expression of Cldn2 resulted in low TER in epithelial monolayers and high permeability to HRP. After treating mice with the 10-day chronic stress, the intestinal epithelial barrier function was markedly compromised, which could be prevented by blocking either CRF, or TLR4, or Cldn2.

Conclusions

Psychological stress-derived CRF can breach the established endotoxin tolerance in the intestinal mucosa.  相似文献   

19.

Objective

To quantitatively evaluate the anterior segment using anterior segment optical coherence tomography (AS-OCT) following Boston keratoprosthesis type 1.

Methods

A retrospective study consisted of AS-OCT imaging at a single time point postoperatively in 52 eyes. Main outcomes measures include anatomical and functional anterior chamber depth (ACD), angle (ACA) and peripheral and proximal synechiae.

Results

The mean time point of imaging was 19.3 months postoperatively. Average anatomical and functional ACD was 2.0 and 0.21 mm respectively, and mean ACA ranged from 2.5° to 6.14° in representative meridians. An average of 8.7 clock hours of angle closure was observed in the 25 eyes in which all meridians were imaged. The majority of eyes showed peripheral (86.5%) and proximal (67.3%) synechiae.

Conclusions

AS-OCT is a useful tool for quantitative evaluation of anterior segment and angle after keratoprosthesis, which is otherwise poorly visible. The majority of eyes showed shallow ACD, extensive angle closure and synechiae formation.  相似文献   

20.