首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
p56(lck) is a lymphocyte-specific tyrosine kinase that plays an important role in both T-cell maturation and activation. We have developed a homogeneous assay in which p56(lck) catalyzes the transfer of the gamma-phosphate group from [gamma-(33)P]ATP to a biotinylated peptide substrate. The labeled peptide is then captured on a streptavidin-coated scintillation proximity assay (SPA) bead or imaging proximity bead. The SPA is counted in a microplate scintillation counter and the imaging proximity assay is counted in a charge-coupled device-based imaging system called LEADseekertrade mark, recently launched as a homogeneous imaging system by Amersham Pharmacia Biotech. We show, via time-dependence assays and inhibitor studies, that this assay can be performed in 1536-well microplate format using imaging proximity as the method of detection. The results compare favorably with the same assay performed in 384-well microplate format using both SPA and imaging proximity as the detection methods. From this study, we conclude that a kinase assay can be performed in 384- and 1536-well format using imaging as the detection method, with significant time savings over standard scintillation counting. In addition, we show cost saving advantages of 1536- over 384-well format in terms of reagent usage, higher throughput, and waste disposal.  相似文献   

2.
Two homogeneous proximity assays for tyrosine kinases, scintillation proximity assay (SPA) and homogeneous time-resolved fluorescence (HTRF), have been developed and compared. In both formats, the kinase assay was performed using biotinylated peptide substrate, ATP ([33P]ATP in the case of SPA), and tyrosine kinase in a 96-well assay format. After the kinase reaction was stopped, streptavidin-coated SPA beads or europium cryptate-labeled anti-phosphotyrosine antibody and streptavidin-labeled allophycocyanin were added as detection reagents for SPA or HTRF assays, respectively. Since the assay signal was detected only when the energy donor (radioactivity for SPA, Eu for HTRF) and the energy acceptor molecules (SPA beads for SPA, allophycocyanin for HTRF) were in close proximity, both assays required no wash or liquid transfer steps. This homogeneous ("mix-and-measure") nature allows these assays to be much simpler, more robust, and easier to automate than traditional protein kinase assays, such as a filter binding assay or ELISA. Both assays have been miniaturized to a 384-well format to reduce the assay volume, thereby saving the valuable screening samples as well as assay reagents, and automated using automated pipetting stations to increase the assay throughput. Several advantages and disadvantages for each assay are described.  相似文献   

3.
4.
A competitive fluorescence polarization (FP) assay has been developed for the serine/threonine kinase, AKT. The FP assay has been formatted in a 384-well microtiter plate and automated using a pipeting workstation with performance suitable for high-throughput screening. The assay design utilizes a fluorescent phosphorylated peptide complexed to a product-specific anti-phospho-serine antibody. When unlabeled substrate is phosphorylated, by the kinase, the product competes with the fluorescent phosphorylated peptide for the antibody. The fluorescent phosphorylated peptide is then released from the antibody into solution resulting in a loss in polarization signal. Seven fluorescent phosphorylated peptides and 19 antibodies were evaluated for this assay. RARTSpSFAEPGK-Fl peptide and anti-phospho-GSK-3alpha Ser21 antibody gave the best affinity and change in polarization signal. The apparent kinetic constants were calculated for the FP assay and were consistent with reported values. The FP assay was validated with known inhibitors and the results compared to a radioactive Flashplate transfer assay, utilizing [(33)P]ATP and a biotinylated substrate, also developed in our laboratory. The IC(50) values generated were comparable between the two methods suggesting the competitive FP assay and Flashplate assay have similar sensitivities and abilities to identify inhibitors during screening.  相似文献   

5.
Reducing costs while maintaining the highest readout quality is a precept of modern high-throughput screening. Given the trend toward nonradiometric screening platforms, this has been a big challenge for some kinase target classes. Common issues include low sensitivity, susceptibility to nonspecific interference, or the need for costly reagents. In this study, the authors describe the feasibility of miniaturization of a serine kinase assay using generic reagents in the AlphaScreen format. They have validated the robustness of this assay in the course of miniaturization from a 35-to 4.375-microL final assay volume in 384-and 1536-well formats. Within this volume range, they consistently obtained Z' values above 0.5 and have investigated the suitability of these assay formats for measuring compound effects by testing a set of 25 previously identified active compounds. These active compounds were also reliably identified in the miniaturized assay formats. The results presented here show that the AlphaScreen technology permits robust and cost-efficient miniaturization of serine/threonine kinase assays.  相似文献   

6.
The herpes virus entry mediator (HVEM) receptor and its ligand, HVEM-L, are involved in both herpes simplex virus type-1 (HSV-1) herpes simplex virus type-2 (HSV-2) infection, and in T-cell activation such that antagonists of this interaction are expected to have utility in viral and inflammatory diseases. In this report we describe the configuration of a homogeneous 384-well assay based on time-resolved energy transfer from a europium chelate on the HVEM receptor to an allophycocyanin (APC) acceptor on the ligand. Specific time resolved emission from the acceptor is observed on receptor:ligand complex formation. The results of various direct and indirect labeling strategies are described. Several assay optimization experiments were necessary to obtain an assay that was robust to automation and file compound interference while sensitive to the effect of potential inhibitors. The signal was stable for more than 24 h at room temperature using the Eu(3+) chelates, suggesting no dissociation of the lanthanide ion. The 384-well assay was readily automated and was able to identify more than 99.5% of known positive controls in the validation studies successfully. Screening identified both a series of known potent inhibitors and several structural classes of hits that readily deconvoluted to yield single compound inhibitors with the desired functional activity in secondary biological assays. The equivalence of the data in 384- and 1536-well formats indicates that routine implementation of 1536-well chelate-based energy transfer screening appears to be primarily limited by liquid handling rather than detection issues.  相似文献   

7.
The demand to increase throughput in HTS programs, without a concomitant addition to costs, has grown significantly during the past few years. One approach to handle this demand is assay miniaturization, which can provide greater throughput, as well as significant cost savings through reduced reagent costs. Currently, one of the major challenges facing assay miniaturization is the ability to detect the assay signal accurately and rapidly in miniaturized formats. Digital imaging is a detection method that can measure fluorescent or luminescent signals in these miniaturized formats. In this study, an imaging system capable of detecting the signal from a fluorescent protease assay in multiple plate formats was used to evaluate this detection method in an HTS environment. A direct comparison was made between the results obtained from the imaging system and a fluorescent plate reader by screening 8,800 compounds in a 96-well plate format. The imaging system generated similar changes in relative signal for each well in the screen, identified the same active compounds, and yielded similar IC(50) values as compared to the plate reader. When a standard protease inhibitor was evaluated in 96-, 384-, 864-, and 1536-well plates using imaging detection, similar IC(50) values were obtained. Furthermore, similar dose-response curves were generated for the compound in 96- and 384-well assay plates read in a plate reader. These results provide support for digital imaging as an accurate and rapid detection method for high-density microtiter plates.  相似文献   

8.
Fluorescence polarization (FP) is an established technique for the study of biological interactions and is frequently used in the high-throughput screening (HTS) of potential new drug targets. This work describes the miniaturization of FP receptor assays to 1536-well formats for use in HTS. The FP assays were initially developed in 384-well microplates using CyDye-labeled nonpeptide and peptide ligands. Receptor expression levels varied from approximately 1 to 10 pmols receptor per mg protein, and ligand concentrations were in the 0.5- to 1.0-nM range. The FP assays were successfully miniaturized to 1536-well formats using Cy3B-labeled ligands, significantly reducing reagent consumption, particularly the receptor source, without compromising assay reliability. Z' factor values determined for the FP receptor assays in both 384- and 1536-well formats were found to be > 0.5, indicating the assays to be robust, reliable, and suitable for HTS purposes.  相似文献   

9.
Highly miniaturized P450 screening assays designed to enable facile analysis of P450 drug interactions in a 1536-well plate format with the principal human cytochrome P450 enzymes (CYP3A4, 2D6, 2C9, 2C19, and 1A2) and Vivid fluorogenic substrates were developed. The detailed characterization of the assays included stability, homogeneity, and reproducibility of the recombinant P450 enzymes and the kinetic parameters of their reactions with Vivid fluorogenic substrates, with a focus on the specific characteristics of each component that enable screening in a low-volume 1536-well plate assay format. The screening assays were applied for the assessment of individual cytochrome P450 inhibition profiles with a panel of selected assay modifiers, including isozyme-specific substrates and inhibitors. IC(50) values obtained for the modifiers in 96- and 1536-well plate formats were similar and comparable with values obtained in assays with conventional substrates. An overall examination of the 1536-well assay statistics, such as signal-to-background ratio and Z' factor, demonstrated that these assays are a robust, successful, and reliable tool to screen for cytochrome P450 metabolism and inhibition in an ultra-high-throughput screening format.  相似文献   

10.
11.
A novel competitive binding assay for protein kinase inhibitors has been developed for high-throughput screening (HTS). Unlike functional kinase assays, which are based on detection of substrate phosphorylation by the enzyme, this novel method directly measures the binding potency of compounds to the kinase ATP binding site through competition with a conjugated binding probe. The binding interaction is coupled to a signal amplification system based on complementation of beta-galactosidase enzyme fragments, a homogeneous, nonisotopic assay technology platform developed by DiscoveRx Corp. In the present study, staurosporine, a potent, nonselective kinase inhibitor, was chemically conjugated to a small fragment of beta-galactosidase (termed ED-SS). This was used as the binding probe to the kinase ATP binding pocket. The binding potencies of several inhibitors with diverse structures were assessed by displacement of ED-SS from the kinase. The assay format was specifically evaluated with GSK3alpha, an enzyme previously screened in a radioactive kinase assay (i.e., measurement of [(33)P]-gamma-ATP incorporation into the kinase peptide substrate). Under optimized assay conditions, nonconjugated staurosporine inhibited ED-SS binding in a concentration-dependent manner with an apparent potency (IC(50)) of 11 nM, which was similar to the IC(50) value determined in a radioactive assay. Furthermore, 9 kinase inhibitors with diverse structures, previously identified from chemical compound library screening, were screened using the competitive binding assay. The potencies in the binding assay were in very good agreement with those obtained previously in the isotopic functional activity assay. The binding assay was adapted for automated HTS using selected compound libraries in a 384-well microtiter plate format. The HTS assay was observed to be highly robust and reproducible (Z' factors > 0.7) with high interassay precision (R(2) > 0.96). Interference of compounds with the beta-galactosidase signal readout was negligible. In conclusion, the DiscoveRx competitive kinase binding assay, termed ED-NSIP trade mark, provides a novel method for screening kinase inhibitors. The format is homogeneous, robust, and amenable to automation. Because there is no requirement for substrate-specific antibodies, the assay is particularly applicable to Ser/Thr kinase assay, in which difficulties in identifying a suitable substrate and antibody preclude development of nonisotopic assays. Although the nonselective kinase inhibitor, staurosporine, was used here, chemically conjugating the ED fragment to other small molecule enzyme inhibitors is also feasible, suggesting that the format is generally applicable to other enzyme systems.  相似文献   

12.
The measurement of intracellular calcium response transients in living mammalian cells is a popular functional assay for identification of agonists and antagonists to receptors or channels of pharmacological interest. In recent years, advances in fluorescence-based detection techniques and automation technologies have facilitated the adaptation of this assay to 384-well microplate format high-throughput screening (HTS) assays. However, the cost and time required performing the intracellular calcium HTS assays in the 384-well format can be prohibitive for HTS campaigns of greater than 1 x 10(6) wells. For these reasons, it is attractive to miniaturize intracellular calcium functional assays to the 1536-well microplate format, where assay volumes and plate throughput can be decreased by several fold. The focus of the research described in this article is the miniaturization of an intracellular calcium assay to 1536-well plate format. This was accomplished by modifying the hardware and software of a fluorometric imaging plate reader (FLIPR) to enable transfer of nanoliters of test compound directly to a 1536-well assay plate, and measure the resulting calcium response from all 1536 wells simultaneously. An intracellular calcium functional assay against the rat muscarinic acetylcholine receptor subtype 1 (rmAchR1) G-protein coupled receptor (GPCR) was miniaturized and executed on this modified instrument. In experiments measuring the activity of known muscarinic receptor agonists and antagonists, the miniaturized FLIPR assay gave EC(50) and IC(50) values and rank order potency comparable to the 384-well format assays. Calculated Z' factors for the miniaturized agonist and antagonist assays were, respectively, 0.56 +/- 0.21 and 0.53 +/- 0.22, which were slightly higher (Z'(agonist) = 0.55 +/- 0.33) and lower (Z'(antagonist) = 0.70 +/- 0.18) than the corresponding values in the 384-well assays. A mock agonist HTS campaign against the muscarinic receptor in miniaturized format was able to identify all wells spiked with the rmAchR1 agonist carbachol.  相似文献   

13.
The family of phosphoinositide 3-kinases (PI3K) regulates fundamental cellular responses such as proliferation, apoptosis, motility, and adhesion. In particular, the PI3K gamma isoform plays a critical role in the control of cell migration. Despite the attractiveness of PI3-kinases as drug targets, drug discovery efforts have been hampered by the lack of appropriate lipid kinase assay formats suitable for high-throughput screening. The authors report the development of a simple and robust 384-well plate assay that is based on(33) P-phosphate transfer from radiolabeled [gamma(33) P]ATP to phosphatidylinositol immobilized on Maxisorp plates. The established assay format for PI3K gamma was easily adapted to the automated screening platform and was successfully employed for high-throughput screening. Enzymatic and inhibition characteristics of recombinant human PI3K gamma determined with the plate assay are in very good agreement with previously reported values determined in other assay formats. Maximal catalytic activity of PI3K gamma was observed at pH 7.0. The apparent K(m) value for ATP using a 1:1 mixture of phosphatidylinositol and phosphatidylserine was determined to be 7.3 microM (6.0-8.6 microM, 95% confidence interval [CI]). IC(50) values for known PI3-kinase inhibitors were determined to be 1.45 nM (1.17-1.80 nM, 95% CI) for wortmannin and estimated from partial inhibition data to be 1400, 2830, and 21,400 nM for quercetin, LY294002, and staurosporine, respectively. This novel assay approach allows for screening of inhibitors of lipid kinases in high-throughput mode and thereby may facilitate the identification of novel inhibitory structures for drug development.  相似文献   

14.
A microplate-based electrophoretic assay has been developed for the serine/threonine kinase protein kinase A (PKA). The ElectroCapture PKA assay developed uses a positively charged, lissamine-rhodamine-labeled kemptide peptide substrate for the kinase reaction and Nanogen's ElectroCapture HTS Workstation and 384-well laminated membrane plates to electrophoretically separate the negatively charged phosphorylated peptide product from the kinase reaction mix. After the electrophoretic separation, the amount of rhodamine-labeled phosphopeptide product was quantified using a Tecan Ultra384 fluorescence reader. The ElectroCapture PKA assay was validated with both known PKA inhibitors and library compounds. The pK(iapp) results obtained in the ElectroCapture PKA assay were comparable to those generated with current radioactive filter-binding assay and antibody-based competitive fluorescence polarization PKA assay formats.  相似文献   

15.
In response to the need for inexpensive high throughput assays for anti-cancer drug screening, a 1536-well microtiter plate based assay utilizing the Alamar Blue fluorescent dye as a measure of cellular growth was validated in 10 μL assay volume. Its robustness was assessed in a screen against a library of 2000 known bioactives; with an overall Z′ value of 0.89 for assay robustness, several known cytotoxic agents were identified including and not limited to anthracyclines, cardiac glycosides, gamboges, and quinones. To further test the sensitivity of the assay, IC50 determinations were performed in both 384-well and 1536-well formats and the obtained results show a very good correlation between the two density formats. These findings demonstrate that this newly developed assay is simple to set up, robust, highly sensitive and inexpensive. It could potentially provide a rapid way to screen established and primary tumor cell lines against large chemical libraries.  相似文献   

16.
In response to the need for inexpensive high throughput assays for anti-cancer drug screening, a 1536-well microtiter plate based assay utilizing the Alamar Blue fluorescent dye as a measure of cellular growth was validated in 10 microL assay volume. Its robustness was assessed in a screen against a library of 2000 known bioactives; with an overall Z' value of 0.89 for assay robustness, several known cytotoxic agents were identified including and not limited to anthracyclines, cardiac glycosides, gamboges, and quinones. To further test the sensitivity of the assay, IC50 determinations were performed in both 384-well and 1536-well formats and the obtained results show a very good correlation between the two density formats. These findings demonstrate that this newly developed assay is simple to set up, robust, highly sensitive and inexpensive. It could potentially provide a rapid way to screen established and primary tumor cell lines against large chemical libraries.  相似文献   

17.
Kinases are important drug discovery targets for a wide variety of therapeutic indications; consequently, the measurement of kinase activity remains a common high-throughput screening (HTS) application. Recently, enzyme-coupled luciferase-kinase (LK) format assays have been introduced. This format measures luminescence resulting from metabolism of adenosine triphosphate (ATP) via a luciferin/luciferase-coupled reaction. In the research presented here, 1536-well format time-resolved fluorescence resonance energy transfer (TR-FRET) and LK assays were created to identify novel Rho-associated kinase II (ROCK-II) inhibitors. HTS campaigns for both assays were conducted in this miniaturized format. It was found that both assays were able to consistently reproduce the expected pharmacology of inhibitors known to be specific to ROCK-II (fasudil IC50: 283 +/- 27 nM and 336 +/- 54 nM for TR-FRET and LK assays, respectively; Y-27632 IC50: 133 +/- 7.8 nM and 150 +/- 22 nM for TR-FRET and LK assays, respectively). In addition, both assays proved robust for HTS efforts, demonstrating excellent plate Z' values during the HTS campaign (0.84 +/- 0.03; 0.72 +/- 0.05 for LK and TR-FRET campaigns, respectively). Both formats identified scaffolds of known and novel ROCK-II inhibitors with similar sensitivity. A comparison of the performance of these 2 assay formats in an HTS campaign was enabled by the existence of a subset of 25,000 compounds found in both our institutional and the Molecular Library Screening Center Network screening files. Analysis of the HTS campaign results based on this subset of common compounds showed that both formats had comparable total hit rates, hit distributions, amount of hit clusters, and format-specific artifact. It can be concluded that both assay formats are suitable for the discovery of ROCK-II inhibitors, and the choice of assay format depends on reagents and/or screening technology available.  相似文献   

18.
19.
The miniaturization of gene transfer assays to either 384- or 1536-well plates greatly economizes the expense and allows much higher throughput when transfecting immortalized and primary cells compared with more conventional 96-well assays. To validate the approach, luciferase and green fluorescent protein (GFP) reporter gene transfer assays were developed to determine the influence of cell seeding number, transfection reagent to DNA ratios, transfection time, DNA dose, and luciferin dose on linearity and sensitivity. HepG2, CHO, and NIH 3T3 cells were transfected with polyethylenimine (PEI)–DNA in both 384- and 1536-well plates. The results established optimal transfection parameters in 384-well plates in a total assay volume of 35 μl and in 1536-well plates in a total assay volume of 8 μl. A luciferase assay performed in 384-well plates produced a Z′ score of 0.53, making it acceptable for high-throughput screening. Primary hepatocytes were harvested from mouse liver and transfected with PEI DNA and calcium phosphate DNA nanoparticles in 384-well plates. Optimal transfection of primary hepatocytes was achieved on as few as 250 cells per well in 384-well plates, with CaPO4 proving to be 10-fold more potent than PEI.  相似文献   

20.
G protein-coupled receptors (GPCRs) are involved in various physiological processes, such as behavior changes, mood alteration, and regulation of immune-system activity. Thus, GPCRs are popular targets in drug screening, and a well-designed assay can speed up the discovery of novel drug candidates. The Promega cAMP-Glo Assay is a homogenous bioluminescent assay to monitor changes in intracellular cyclic adenosine monophosphate (cAMP) concentrations in response to the effect of an agonist, antagonist, or test compound on GPCRs. Together with the Labcyte Echo 555 acoustic liquid handler and the Deerac Fluidics Equator HTS reagent dispenser, this setup can screen compounds in 96-, 384-, and 1536-well formats for their effects on GPCRs. Here, we describe our optimization of the cAMP-Glo assay in 1536-well format, validate the pharmacology, and assess the assay robustness for HTS. We have successfully demonstrated the use of the assay in primary screening applications of known agonist and antagonist compounds, and confirmed the primary hits via secondary screening. Implementing a high-throughput miniaturized GPCR assay as demonstrated here allows effective screening for potential drug candidates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号