首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and specific competitive enzyme-linked immunosorbent assay (ELISA) for rat prolactin was developed using reagents from the National Institute of Arthritis, Diabetes, Digestive Diseases and Kidney. In this assay soluble prolactin and prolactin adsorbed to a solid-phase support compete for rabbit anti-prolactin antibody binding sites. Therefore, a high concentration of soluble prolactin in the sample will result in a low concentration of antibody immobilized to the adsorbed prolactin. The immobilized antibody-prolactin complex is detected and quantified using goat anti-rabbit immunoglobulin G covalently conjugated to the enzyme horseradish peroxidase. Assay parameters were optimized by investigating the concentration of reagents and the reaction kinetics in each of the assay steps. The assay can be performed in 24 h. A sensitivity range of 0.06 to 6 ng in the region of 90 to 10% binding was obtained. Near 50% binding (0.6 ng), the intraassay coefficient of variation (CV) was 4.2% and the interassay CV was 7.6%. The correlation between radioimmunoassay and the ELISA was 0.868. Selected applications of the assay are described. The assay should prove a useful alternative to the radioimmunoassay in those instances where steps involving the use of 125I become limiting, for example, iodination facility and gamma counter availability or prolonged reagent storage.  相似文献   

2.
Apolipoprotein A-V (apoA-V) is a recently discovered apolipoprotein that appears to have a role in plasma triglyceride (TG) transport. We have developed an ELISA for apoA-V using monoclonal antibodies that has a lower limit of detection of 0.3 ng/ml and linearity up to 20 ng/ml. The ELISA was then used to quantify plasma apoA-V in 196 healthy subjects and 106 patients with insulin-resistant diabetes mellitus. In the healthy subjects, total apoA-V concentration was 179.2 +/- 74.8 ng/ml, and it was greater in females than in males (P < 0.005). It was correlated positively with the plasma HDL cholesterol (r = 0.32, P < 0.0001), apoA-I (r = 0.27, P = 0.0001), and apoE (r = 0.18, P = 0.011) concentrations and negatively with plasma TG concentration (r = -0.22, P = 0.021). In relation to single nucleotide polymorphism 3 (-1131C/T) of the apoA-V gene, apoA-V concentration was higher in the T/T type than in the C/C type (P < 0.01). Plasma TG concentration was lower in the T/T type than in the C/C or C/T type (P < 0.05). ApoA-V concentration was lower in the diabetic patients (69.4 +/- 44.3 ng/ml; P < 0.01) than in the healthy controls.  相似文献   

3.
Click chemistry is explored as a potential cost-effective and selective immobilization method for the production of an enzyme-linked immunosorbent assay (ELISA). Coatings were formulated containing either a terminal alkyne or a bicyclo[6.1.0]non-4-yne (BCN) chemical handle, and a diagnostic peptide was subsequently immobilized onto these coatings by the copper-catalyzed azide-alkyne 1,3-dipolar cycloaddition (CuAAC) or copper-free strain-promoted azide-alkyne 1,3-dipolar cycloaddition (SPAAC), respectively. The terminal alkyne-containing coating showed high background levels in subsequent ELISA's due to the copper catalyst used in the immobilization step. The BCN-containing coating, however, was successfully employed and presents a cost-effective alternative to existing (strept)avidin-biotin immobilization methods. This technology was illustrated with an ELISA used for the diagnosis of rheumatoid arthritis (RA) but could be easily applied to a wide range of diagnostic tests.  相似文献   

4.
A method for measuring human apolipoprotein A-IV has been developed using the competitive enzyme-linked immunosorbent assay (ELISA) system. The assay described is relatively easy, rapid, and inexpensive to perform, uses convenient dilutions of plasma (1/8-1/32) but is sensitive enough to quantitate the apoA-IV content of lipoproteins following gel filtration of small (0.3-0.5 ml) volumes of plasma. The working range is 100-600 ng of apoA-IV per 50-microliters sample and the intra- and interassay coefficients of variations are 7.5 and 10.2% (means), respectively. The mean apoA-IV concentration of 100 subjects was found to be 16.4 +/- 5.4 mg/dl. The assay can be performed on untreated plasma samples which may be stored frozen (-20 degrees C) for up to 2 months.  相似文献   

5.
A rapid sandwich enzyme-linked immunosorbent assay (ELISA) for the quantitation of human apolipoprotein (apo) A-I was developed. The assay uses a pair of noncompeting purified monoclonal antibodies to detect apoA-I in plasma. The antibodies used in this assay were selected because they bind greater than 90% of radioiodinated high density lipoprotein (HDL), they identify "fresh" nondeamidated epitopes on apoA-I, and they have comparable binding affinities for isolated HDL and HDL in plasma. The assay was standardized with a plasma secondary standard composed of lyophilized human serum. The assay was used to measure the apoA-I levels in normal subjects, patients with coronary artery disease, and patients with familial hypercholesterolemia. The results indicate that certain monoclonal antibodies can be used to reliably measure plasma levels of apoA-I in diverse groups of subjects.  相似文献   

6.
Here we demonstrate a novel microwave-mediated enzyme-linked immunosorbent assay (MELISA) method that has dramatically reduced the enzyme-linked immunosorbent assay (ELISA) timing to less than 5 min with a result comparable to that obtained by 18-h conventional ELISA. Efficacy of the MELISA procedure is demonstrated by detecting human immunoglobulin G (IgG), rabbit IgG, human immunoglobulin E (IgE), human interleuken 1β (IL-1β), Entamoeba histolytica antibody, and Aspergillus fumigatus antibody. MELISA could be an excellent substitute for time-consuming conventional ELISA for rapid diagnosis of diseases in cases of medical urgency, outbreak of infectious diseases, and screening of samples in blood banks or emigration counters.  相似文献   

7.
The development of an enzyme-linked immunosorbent assay (ELISA) for uridine 5'-diphospho-N-acetyl-glucosamine: alpha mannoside beta 1----6 N-acetylglucosaminyltransferase (GnT-V) is reported. The assay quantitates the enzymatic conversion of the specific synthetic GnT-V acceptor GlcNAc beta 1----2Man alpha 1----6Man beta-R (5) to the product GlcNAc beta 1----2[GlcNAc-beta 1----6]Man alpha 1----6Man beta-R (6) when these oligosaccharide structures were covalently attached to bovine serum albumin which was then coated on microtiter wells. Conversion of 5 to 6 was detected using a polyclonal antiserum raised against the product 6 and from which antibodies cross-reacting with acceptor 5 had been removed by affinity adsorption. GnT-V activity detected by ELISA was linearly proportional to both enzyme concentration and time under appropriate experimental conditions where 50-300 fmol of product was formed per microtiter well. GnT-V activity could be measured by ELISA in Triton X-100 extracts of hamster kidney acetone powder and in human serum. The twofold increase in GnT-V activity which is known to accompany Rous sarcoma virus transformation of baby hamster kidney cells could also be quantitated using the ELISA.  相似文献   

8.
A double-antibody sandwich, enzyme-linked immunosorbent assay has been developed for phytochrome in Avena sativa L. cv. Saladin. An immunoglobulin fraction of rabbit antiserum raised to 118 kdalton phytochrome was used with alkaline phosphatase as the enzyme label. The assay detected as little as 0.2 ng phytochrome in extracts of dark-grown plant material. No evidence for specific or non-specific measurement of proteins other than phytochrome was found. The assay detected phytochrome in extracts of Avena grown in the light. Dilution curves for light-grown phytochrome extracts had a reduced slope and saturated at a lower level of enzyme activity than those for dark extracts. These differences were not caused by an inhibitor in extracts from light-grown plants. Phytochromes from dark- and light-grown plants may be immunologically different.  相似文献   

9.
10.
A sensitive and specific enzyme-linked immunosorbent assay (ELISA) for nonhuman primate serum apolipoprotein A-I (apoA-I) is described. The assay is a noncompetitive, sandwich ELISA in which polystyrene microtiter plates were used with purified, monospecific goat anti-monkey apoA-I antibodies adsorbed on the wells. The serum samples were added to the coated wells, incubated, and after washing, antibodies conjugated to horseradish peroxidase were added. After further washing, the bound label was assayed. A heat treatment step, 52 degrees C for 3 hr, was used to maximize the apoA-I immunoreactive sites in diluted serum. Serum samples extracted with chloroform-methanol, delipidated with tetramethylurea, or denatured by heating gave essentially equivalent results. The working range of the apoA-I standards was 0.5 to 5 ng and parallel responses were observed for apoA-I in serum, in isolated HDL, and in buffer as a purified apoprotein. Recovery of apoA-I added to serum was quantitative (106 +/- 3%). The intra- and interassay coefficients of variation were 6.2 and 6.9%, respectively. The enzyme immunoassay yielded values that compared favorably with those obtained by radial immunodiffusion (r = 0.84). ApoA-I concentration in African green monkey serum was highly correlated with the HDL cholesterol concentration (r = 0.86). It is concluded that this ELISA is an accurate and precise method for determination of apoA-I concentrations in primate serum.  相似文献   

11.
12.
Seven monoclonal antibodies (mAbs) against the wheat allergen, Tri a Bd 17 K, were prepared to obtain mAbs suitable for a sandwich enzyme-linked immunosorbent assay (sandwich ELISA) for determination of the allergen. Two of the mAbs strongly immunoblotted the allergen purified from wheat flour. However, only one (1G11) of them was found to be suitable for sandwich ELISA. Epitope mapping against mAb-1G11 on the allergen showed that the mAb recognized the peptide containing Lys-38 and Gln-39 of the allergen. We developed a sandwich ELISA method consisting of Aleuria aurantia lectin for fixing the allergen and 1G11 as the first antibody that enabled 4-4,000 ng/well of the allergen to be determined.  相似文献   

13.
G J Marcus  R Durnford 《Steroids》1985,46(6):975-986
A new, enzyme-linked, immunosorbent assay for testosterone is described. The assay uses horseradish peroxidase coupled to testosterone as the tracer and offers the same sensitivity and reliability but greater convenience than radioimmunoassay. The assay is also simpler and more rapidly completed than previously described assays for testosterone.  相似文献   

14.
Macromolecules that can assemble a large number of enzyme and antibody molecules have been used frequently for improvement of sensitivities in enzyme-linked immunosorbent assays (ELISAs). We generated bionanocapsules (BNCs) of approximately 30 nm displaying immunoglobulin G (IgG) Fc-binding ZZ domains derived from Staphylococcus aureus protein A (designated as ZZ-BNC). In the conventional ELISA using primary antibody and horseradish peroxidase-labeled secondary antibody for detecting antigen on the solid phase, ZZ-BNCs in the aqueous phase gave an approximately 10-fold higher signal. In Western blot analysis, the mixture of ZZ-BNCs with secondary antibody gave an approximately 50-fold higher signal than that without ZZ-BNCs. These results suggest that a large number of secondary antibody molecules are immobilized on the surface of ZZ-BNCs and attached to antigen, leading to the significant enhancement of sensitivity. In combination with the avidin-biotin complex system, biotinylated ZZ-BNCs showed more significant signal enhancement in ELISA and Western blot analysis. Thus, ZZ-BNC is expected to increase the performance of various conventional immunoassays.  相似文献   

15.
Vibrio vulnificus hemolysin, purified by quantitative isoelectric focusing, was used to prepare rabbit and goat anti-hemolysin. The resulting antibodies were used as capture and detector antibody reagents in a sandwich enzyme-linked immunosorbent assay (ELISA) to detect V. vulnificus in environmental samples. By this technique, 4 laboratory-maintained V. vulnificus strains and 33 environmental V. vulnificus isolates were detected. Also, the technique distinguished five other Vibrio species from V. vulnificus, and when it was used in combination with colistin-polymyxin-cellobiose agar, 31 non-V. vulnificus isolated were excluded. This sandwich ELISA compared favorably with the current Food and Drug Administration standard immunoassay in confirming presumptive V. vulnificus colonies from environmental specimens: oysters, sediment, and seawater. Among 340 presumptive V. vulnificus colonies, the sandwich ELISA detected 95% of the confirmed V. vulnificus colonies. Equally important, the technique correctly distinguished 99% of the non-V. vulnificus colonies. The sandwich ELISA offers time-saving and labor-saving advantages over the currently accepted immunoassay.  相似文献   

16.
A highly sensitive sandwich enzyme-linked immunosorbent assay for rat apo A-I was developed. Samples and standards were added to each well of microtiter plates precoated with immunoaffinity-purified IgG. Bound apo A-I was detected with immunoaffinity-purified Fab'-horseradish peroxidase conjugate by a colorimetric method. The sensitivity reached 2.5 pg/well, and the working range for the measurement of serum apo A-I concentration was 0.1 to 1.0 ng/well. The mean intra- and interassay coefficients of variation were 2.8 and 4.1%, respectively. The epitopes of apo A-I in serum were effectively exposed by the use of 6 mol/liter guanidine.HCl. Serum apo A-I concentrations in 36- to 40-week-old rats (62.3 +/- 8.6 mg/dl, mean +/- SD, n = 16) were significantly higher (P less than 0.05) than those in 8- to 12-week-old rats (55.1 +/- 4.3 mg/dl, n = 9). But the age-related change of serum apo A-I was much smaller than that of serum apo E. Apo A-I was contained in smaller HDL particles (or HDL2) in normal rat serum.  相似文献   

17.
Summary We have developed a new enzyme-linked immunosorbent assay for determination of H-Y phenotype in the human. This assay, which measures the inhibition of the reaction of a monoclonal anti-H-Y antibody and a mouse testis extract as a source of H-Y antigen, was applied to the supernatant of lymphocytes from ten normal male and ten normal female subjects. Introduction of supernatant from male cells gave reading of 69%–78% of those obtained with testis supernatant alone; female-cell supernatant did not inhibit the reaction (89%–102%).  相似文献   

18.
The epitopes for two monoclonal antibodies (MAbs) directed towards human apolipoprotein A-I (apoA-I), designated AI-1 and AI-3, have been more precisely defined. Previous work in our laboratory demonstrated that AI-1 and AI-3 recognize antigenic determinants located within cyanogen bromide (CNBr) fragments 1 (CF1) and 3 (CF3), respectively. Using peptides generated from endoproteinase cleavage of CF1 and CF3, we now report that both MAbs are specific for two previously unreported epitopes along the apoA-I molecule. The ability of whole endoproteinase digest mixtures to bind the MAbs, as determined by means of a competitive enzyme-linked immunosorbent assay (ELISA), indicated regions of CF1 and CF3 that were likely to form the epitopes. Purified peptides derived from the digests were then used to localize the epitopes recognized by MAbs AI-1 and AI-3 to within residues 28-47 and 140-147 of apoA-I, respectively. We have previously reported that the epitopes for both MAbs are exposed on HDL2, HDL3, and free apoA-I. Thus, the precise mapping of the binding sites recognized by AI-1 and AI-3 has enabled the identification of regions along apoA-I that are exposed on the surface of lipoprotein particles.  相似文献   

19.
An enzyme-linked immunosorbent assay (ELISA) has been developed to measure apolipoproteins in rat serum. Nondelipidated whole serum was heat-treated at 52 degrees C for 3 h in phosphate-buffered saline containing 0.1% Tween-20 before assay. Monospecific rabbit anti-rat apolipoprotein antibodies were added to 96-well polystyrene microtiter plates which had been coated with purified rat serum apolipoproteins or unknown samples. After incubation and washing, goat anti-rabbit serum antibodies conjugated with horseradish peroxidase were added to the plates and incubated. The bound peroxidase activity was assayed after further washing. Serum apolipoprotein concentrations were calculated by comparison against purified standards that were assayed simultaneously with the unknown samples. The intraassay coefficients of variation for apolipoprotein AI, E, and AIV (Apo AI, E, and AIV) were 2.3, 4.4, and 5.3%, and interassay coefficients of variation were 6.1, 5.5, and 7.9%, respectively. The ELISA assay is sensitive to nanogram quantities of rat serum apolipoproteins and the results agree well with those measured by densitometry. The serum concentrations of Apo AI, E, and AIV of a normal fed rat were found to be 504 +/- 8, 413 +/- 20, and 262 +/- 20 micrograms/ml, respectively. When cultured as monolayers in Waymouth's medium for 1 day, rat hepatocytes secreted Apo AI, E, and AIV at rates of 2.51, 61.8, and 48.9 ng protein/mg cell protein/h.  相似文献   

20.
A two-site enzyme-linked immunosorbent assay for inhibin.   总被引:1,自引:0,他引:1  
The investigation of the role of inhibin in the regulation of fertility is hindered by the lack of a routine, specific assay. The pituitary cell bioassay is time-consuming and the existing RIAs, based on either purified bovine 32-kDa inhibin or synthetic alpha-subunit peptides, are not specific for the biologically active inhibin molecules. We have used monoclonal antibodies, one specific for the N-terminal region of the human inhibin alpha chain, and the other raised to a peptide sequence close to the C-terminal of the human beta A-inhibin chain, to create a two-site sandwich ELISA specific for alpha beta-inhibin molecules. This was used to estimate levels of inhibin in crude bovine and human follicular fluids and fractions concentrated from them. Comparison of the values obtained with the ELISA and those obtained with the pituitary cell bioassay, suggests that the ELISA measures biologically active inhibin. Compared with the peptide-based RIA, the ELISA gave much lower (as little as 100-fold lower) values for the inhibin content of these samples, e.g., bovine follicular fluid 0.375 micrograms/ml (ELISA) compared with 41.0 micrograms/ml (RIA). Such large differences, possibly due to the presence of relatively large amounts of biologically inactive forms of inhibin such as the pro-alpha c or free alpha forms, suggest that those RIAs, which essentially measure the level of alpha-inhibin, considerably overestimate the levels of the active forms of inhibin in the samples and that results obtained using these assays may need reinterpretation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号