首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A new HPLC method for the simultaneous determination of celecoxib, carboxycelecoxib and hydroxycelecoxib in human plasma samples has been developed. Following a solid-phase extraction procedure, the samples were separated by gradient reversed-phase HLPC (C(18)) and quantified using UV detection at 254 nm. The method was linear over the concentration range 10-500 ng/ml. The intra-assay variability for the three analytes ranged from 4.0 to 12.6% and the inter-assay variability from 4.9 to 14.2%. The achieved limits of quantitation (LOQ) of 10 ng/ml for each analyte allowed the determination of the pharmacokinetic parameters of the analytes after administration of 100 mg celecoxib.  相似文献   

2.
A new high-performance liquid chromatographic (HPLC) assay was developed for the determination of nimodipine in monkey plasma. An ethyl acetate extraction procedure was employed with a reversed-phase HPLC separation for the analysis. Absolute recovery of nimodipine from plasma was over 95% with a lower limit of quantitation of 10 ng/ml. This method was applied to a preliminary pharmacokinetic study in which 0.25 mg/kg nimodipine was administered intravenously to three monkeys. Protein binding and stability of nimodipine in monkey plasma were also examined. The pharmacokinetic parameters of nimodipine in monkeys were similar to those obtained in humans and indicate that monkeys are an appropriate animal model for further pharmacokinetic investigations.  相似文献   

3.
An HPLC method for determining quercetin in human plasma and urine is presented for application to the pharmacokinetic study of rutin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using kaempferol as an internal standard. Solid-phase extraction was performed on an Oasis HLB cartridge (>95% recovery). The HPLC assay was carried out using a Luna ODS-2 column (150 x 2.1 mm I.D., 5 microm particle size). The mobile phase was acetonitrile-10 mM ammonium acetate solution containing 0.3 mM EDTA-glacial acetic acid, 29:70:1 (v/v, pH 3.9) and 26:73:1 (v/v, pH 3.9) for the determination of plasma and urinary quercetin, respectively. The flow-rate was 0.3 ml/min and the detection wavelength was set at 370 nm. Calibration of the overall analytical procedure gave a linear signal (r>0.999) over a concentration range of 4-700 ng/ml of quercetin in plasma and 20-1000 ng/ml of quercetin in urine. The lower limit of quantification was approximately 7 ng/ml of quercetin in plasma and approximately 35 ng/ml in urine. The detection limit (defined at a signal-to-noise ratio of about 3) was approximately 0.35 ng/ml in plasma and urine. A preliminary experiment to investigate the plasma concentration and urinary excretion of quercetin after oral administration of 200 mg of rutin to a healthy volunteer demonstrated that the present method was suitable for determining quercetin in human plasma and urine.  相似文献   

4.
A simple, sensitive and reproducible HPLC method is presented for the simultaneous determination of mycophenolic acid (MPA) and its metabolites phenolic MPA-glucuronide (MPAG) and acyl glucuronide (AcMPAG) in human plasma. Sample purification requires protein precipitation with 0.1 M phosphoric acid/acetonitrile in the presence of Epilan D as an internal standard (IS). Separation was performed by reversed-phase HPLC, using a Zorbax SB-C18 column, 32% acetonitrile and a 40 mM phosphoric acid buffer at pH 3.0 as mobile phase; column temperature was 50 degrees C, flow rate 1.4 ml/min, and measurement by UV detection was at 215 nm (run time 12 min). The method requires only 50 microl plasma. Detection limits were 0.1 microg/ml for MPA and AcMPAG, and 2.0 microg/ml for MPAG, respectively. Mean absolute recovery of all three analytes was >95%. This analytical method for the determination of MPA and its metabolites is a reliable and convenient procedure that meets the criteria for application in routine clinical drug monitoring and pharmacokinetic studies.  相似文献   

5.
A column-switching high-performance liquid chromatography (HPLC) method for the determination of aloesin in rat plasma using column-switching and ultraviolet (UV) absorbance detection is described. Plasma was directly injected onto the HPLC system consisting of a clean-up column, a concentrating column, and an analytical column, which were connected with a six-port switching valve. The determination of aloesin was accurate and repeatable, with a limit of quantitation of 10 ng/ml in plasma. The standard calibration curve for aloesin was linear (r=0.998) over the concentration range of 10–1000 ng/ml in rat plasma. The intra- and inter-day assay variabilities of aloesin ranged from 1.0 to 4.7% and 1.1 to 8.8%, respectively. This highly sensitive and simple method has been successfully applied to a pharmacokinetic study after oral administration of aloesin to rats.  相似文献   

6.
Imidazenil, an imidazobenzodiazepine car☐amide derivative, is a novel anxiolytic and anti-convulsant agent recently characterized as a partial allosteric modulator of GABAA receptors. Owing to the pharmacological and pharmacokinetic importance of plasma-level determination, a HPLC method has been developed. Imidazenil was extracted from a plasma sample after a partition with diethyl ether, using alprazolam as internal standard. The analysis was performed by a normal-phase HPLC method with UV detection at 255 nm. The limit of quantitation was 6 ng corresponding to 30 ng/ml of plasma concentration. This procedure has been successfully applied to the quantitation of imidazenil plasma levels in primarily pharmacokinetic studies after a single i.v. and an oral administration of the compound to the rat.  相似文献   

7.
A method of quantitative determination of azithromycin in HPLC with mass spectrometric detection was developed. The detection limit is 0.5 ng/ml. The method was used in the study of pharmacokinetics and bioequivalence of Zi-Factor (capsules of 250 mg of azithromycin made by Veropharm, Russia) vs. reference-drug. The pharmacokinetic study was performed by the open cross randomized procedure in 18 volunteers. The pharmacokinetic parameters required for estimation of the drug bioequivalence were calculated. The statistical analysis of the pharmacokinetic parameters revealed bioequivalence of Zi-Factor and the reference-drug.  相似文献   

8.
A method using high-performance liquid chromatography (HPLC) and solid-phase extraction (SPE) is described for the determination of ginsenoside Rg3 in human plasma. A 2.5-ml volume of plasma was mixed with 2.5 ml 60% methanol aqueous solution, and centrifuged at 1100 g for 10 min, the supernatant fluid was further purified by SPE with 200 mg/5 ml 40 μm octadecyl silica and separation was obtained using a reversed-phase column under isocratic conditions with ultraviolet absorbance detection. The intra- and inter-day precision, determined as relative standard deviations, were less than 5.0%, and method recovery was more than 97%. The lower limit of quantitation, based on standards with acceptable RSDs, was 2.5 ng/ml. No endogenous compounds were found to interfere with analyte. A good linear relationship with a regression coefficient of 0.9999 in the range of 2.5 to 200 ng/ml was observed. This method has been demonstrated to be suitable for pharmacokinetic studies in humans. Method development for determination of drug with low UV absorption by SPE and HPLC is also discussed.  相似文献   

9.
A sensitive method was developed for the simultaneous determination of omeprazole and its major metabolites 5-hydroxyomeprazole and omeprazole sulfone in human plasma by HPLC-electrospray mass spectrometry. Following liquid-liquid extraction HPLC separation was achieved on a ProntoSil AQ, C18 column using a gradient with 10 mM ammonium acetate in water (pH 7.25) and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH(+) ions, m/z 346 for omeprazole, m/z 362 for 5-hydroxy-omeprazole and omeprazol-sulfone and m/z 300 for the internal standard (2-{[(3,5-dimethylpyridine-2-yl)methyl]thio}-1H-benzimidazole-5-yl)methanol. The limit of quantification (LOQ) achieved with this method was 5 ng/ml for 5-hydroxyomeprazole and 10 ng/ml for omeprazole and omeprazole-sulfone using 0.25 ml of plasma. Intra- and inter-assay variability was below 11% over the whole concentration range from 5 to 250 ng/ml for 5-hydroxyomeprazol and from 10 to 750 ng/ml for omeprazole and omeprazole-sulfone. The method was successfully applied to the determination of pharmacokinetic parameters of esomeprazole and the two major metabolites after a single dose and under steady state conditions.  相似文献   

10.
A simple extraction procedure and a sensitive high-performance liquid chromatographic (HPLC) method are described for the determination of the photodynamic therapeutic agent 5, 10, 15, 20-tetra(m-hydroxyphenyl)chlorin (mTHPC) in plasma and tumour tissue. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70×4.6 mm I.D.) with a mobile phase of 0.01 M potassium dihydrogenphosphate buffer, pH 2.5-acetonitrile (55:45, v/v) and a coulometric detection (+0.80 V). The mean recoveries of mTHPC in the concentration ranges (5–2000 and 10–1000 ng/ml) were 90 and 89% for plasma and tumour samples, respectively. The procedure for plasma and tissue preparation involved solvent precipitation using methanol combined with ammonia solution and dimethyl sulphoxide (4, 0.2, 0.1, v/v/v) and (2, 0.1, 0.1, v/v/v) for plasma and tissue, respectively. For mTHPC at concentrations ranging from 5 to 2000 ng/ml, the within-day relative standard deviations, based on triplicate determinations were less than 8% and the between-day relative standard deviations calculated by performing extraction procedure of plasma samples on three different days ranged from 3 to 18%. This highly sensitive method, 5 and 10 ng/ml for plasma and tissue respectively, was applied successfully to the determination of mTHPC in mouse tumours for pharmacokinetic studies.  相似文献   

11.
The aim of this study was to develop a high-performance liquid chromatographic (HPLC) assay for the determination of moxifloxacin in human plasma and lung tissue. The assay was based on HPLC with a Supelcosil ABZ+ column and ultraviolet detection set at a wavelength of 296 nm. The extraction procedure was characterized by a fully automated liquid–solid extraction using an OASIS column for the solid phase. The assay has been found to be linear and validated over the concentration range 3.2 to 0.025 μg/ml for moxifloxacin in plasma and from 16 to 0.25 μg/g for moxifloxacin in lung tissue. In future, the assay will support the pharmacokinetic study of the penetration of moxifloxacin in human lung tissue.  相似文献   

12.
The determination of six methylpyrazines was performed using high-performance liquid chromatography (HPLC). Methylpyrazines were simultaneously extracted and injected onto a silica gel column with a syringe-type minicolumn packed with diatomaceous earth granules. The extraction—injection solvent used was dichloromethane and the mobile phase solvent for HPLC was dichloromethane containing 0.08% of 1.65 M ammonia solution and 0.5% of methanol. Methylpyrazines were detected using an ultraviolet detector set at 275 nm. Linear relationships between the amount of sample and peak height were confirmed from 50 ng/ml to 10 μg/ml of the biofluids. When an aliquot of 10 μl of biofluid was introduced to the minicolumn, the detection limit of methylpyrazines was as low as 30 ng/ml with each pyrazine derivative. The method is simple and accurate and is thus applicable to pharmacokinetic studies which are performed on animals. The results showed that the possible pharmacological effects of methylpyrazines might be evaluated pharmacokinetically using this newly developed technique.  相似文献   

13.
A new method of analysis has been developed and validated for the determination of firocoxib, a new nonsteroidal anti-inflammatory drug (NSAID) approved for use in horses and dogs to control pain and inflammation associated with osteoarthritis. Following a liquid extraction using ethyl acetate:hexane (40:60), samples were separated by isocratic reversed-phase HPLC on a Sunfire C(18) column and quantified using UV detection at 290 nm. The mobile phase was a mixture of water with 0.025% trifluoroacetic acid and acetonitrile, with a flow-rate of 1.1 ml/min. The procedure produced a linear curve over the concentration range 5-1500 ng/ml with a lower limit of quantification of 5 ng/ml. Intra- and inter-assay variability was less than 7%. The average recovery was 98%. The method is suitable for the analysis of clinical samples from pharmacokinetic studies and can also be used for small volume sample sizes.  相似文献   

14.
Atomoxetine is the first, non-stimulant alternative to other stimulant medications used for the treatment of Attention-Deficit/Hyperactivity Disorder (ADHD). Reported methods for the determination of atomoxetine include expensive liquid chromatography tandem mass spectrometry (LCMS) and high performance liquid chromatography (HPLC) with liquid scintillation counting (LSC) detection. Till date, no method has been reported in literature to determine atomoxetine using HPLC with UV detection. In this paper, we describe a new HPLC method for the determination of atomoxetine using liquid-liquid extraction with tertiary butyl methyl ether and UV detector. This method was found to be linear over the concentration range of 0.05-3.0 microg/ml. The limit of quantification was 0.05 microg/ml. Intra- and inter-day precision was <15% and accuracy was in the range of 95.67-108.80%. Stability studies showed that atomoxetine was stable in human plasma for short- and long-term period for sample preparation and analysis. This method was used for sample analysis in a pharmacokinetic study of atomoxetine (25mg) in five healthy adult female volunteers. The observed mean+/-S.D. pharmacokinetic parameters Cmax, Tmax and AUC(0-t) were 0.40+/-0.06 microg/ml, 3.40+/-0.42 h and 1.34+/-0.52 microg h/ml, respectively.  相似文献   

15.
Several methods for quantification of docetaxel have been described mainly using HPLC. We have developed a new isocratic HPLC method that is as sensitive and simpler than previous methods, and applicable to use in clinical pharmacokinetic analysis. Plasma samples are spiked with paclitaxel as internal standard and extracted manually on activated cyanopropyl end-capped solid-phase extraction columns followed by isocratic reversed-phase HPLC and UV detection at 227 nm. Using this system, the retention times for docetaxel and paclitaxel are 8.5 min and 10.5 min, respectively, with good resolution and without any interference from endogenous plasma constituents or docetaxel metabolites at these retention times. The total run time needed is only 13 min. The lower limit of quantification is 5 ng/ml using 1 ml of plasma. The validated quantitation range of the method is 5–1000 ng/ml with RSDs≤10%, but plasma concentrations up to 5000 ng/ml can be accurately measured using smaller aliquots. This method is also suitable for the determination of docetaxel in urine samples under the same conditions. The method has been used to assess the pharmacokinetics of docetaxel during a phase I/II study of docetaxel in combination with epirubicin and cyclophosphamide in patients with advanced cancer.  相似文献   

16.
A simple, rapid, sensitive and reliable high performance liquid chromatography (HPLC) method for the determination of the anti-ulcer drug sofalcone in human plasma was developed. Plasma was extracted with ethyl acetate under acidic conditions and sofalcone was determined by HPLC using a C18 column and (methanol-0.1% formic acid aqueous 80:20) mobile phase. The linear calibration curves of sofalcone in human plasma were obtained over the concentration range of 0.01-5.0 microg/ml. The lower limit of quantitation (LLOQ) was 10 ng/ml in human plasma. The precision measured for plasma was within 15%. Extraction recovery was over 85% in blood. The method was successfully applied to the identification and quantification of sofalcone in pharmacokinetic studies.  相似文献   

17.
A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25–100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25–100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.  相似文献   

18.
A new method is described using solid-phase extraction (SPE) for preconcentration of articaine and the metabolite articainic acid and high-performance liquid chromatography (HPLC) for the determination of both compounds in human serum. Articaine and articainic acid were extracted in one step with SDB-RPS disk cartridges after precipitation of the serum proteins by perchloric acid. The HPLC separation was then performed on a reversed-phase C8 column using phosphate buffer–acetonitrile (88:12, v/v). UV absorption at 274 nm was used for measuring the analytes with a low limit of quantitation of about 10 ng/ml, which is appropriate for pharmacokinetic studies of low dose submucosal injections of the local anaesthetic agent articaine hydrochloride in dentistry.  相似文献   

19.
A reversed-phase, column-switching high-performance liquid chromatographic (HPLC) method is described for the determination of a new thymidylate synthase inhibitor in human plasma. The compound and an internal standard are extracted from plasma using a Certify II solid-phase cartridge. Extracts are evaporated to dryness and the residue is reconstituted with mobile phase buffer. The analytes are separated from polar interferences and buffer salts originating from the elution step on a 4-mm YMC Basic pre-column. The fraction containing the analytes is further separated on a 25-cm YMC Basic column. The analytes are detected by their absorbance at 250 nm. The limit of quantitation is 10 ng/ml. The method is linear from 10 ng/ml to 80 μg/ml using three standard curve ranges. Validation studies for all three ranges show the method to be reproducible. The method has been successfully used to support pharmacokinetic studies.  相似文献   

20.
A rapid, selective and reproducible high-performance liquid chromatographic (HPLC) method with ultraviolet detection was developed for the determination of the anti-cancer agent Taxotere in biological fluids. The method involves a solid-phase extraction step (C2 ethyl microcolumns) using a Varian Advanced Automated Sample Processor (AASP) followed by reversed-phase HPLC. The validated quantitation range of the method is 10–2500 ng/ml in plasma with coefficients of variation ≤ 11%. The method is also suitable for the determination of Taxotere in urine samples under the same conditions. The method was applied in a phase I tolerance study of Taxotere in cancer patients, allowing the pharmacokinetic profile of Taxotere to be established.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号