首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Whole genome amplification (WGA) procedures such as primer extension preamplification (PEP) or multiple displacement amplification (MDA) have the potential to provide an unlimited source of DNA for large-scale genetic studies. We have performed a quantitative evaluation of PEP and MDA for genotyping single nucleotide polymorphisms (SNPs) using multiplex, four-color fluorescent minisequencing in a microarray format. Forty-five SNPs were genotyped and the WGA methods were evaluated with respect to genotyping success, signal-to-noise ratios, power of genotype discrimination, yield and imbalanced amplification of alleles in the MDA product. Both PEP and MDA products provided genotyping results with a high concordance to genomic DNA. For PEP products the power of genotype discrimination was lower than for MDA due to a 2-fold lower signal-to-noise ratio. MDA products were indistinguishable from genomic DNA in all aspects studied. To obtain faithful representation of the SNP alleles at least 0.3 ng DNA should be used per MDA reaction. We conclude that the use of WGA, and MDA in particular, is a highly promising procedure for producing DNA in sufficient amounts even for genome wide SNP mapping studies.  相似文献   

2.
Current microarray technology allows researchers to genotype a large number of SNPs with relatively small amounts of DNA. Nevertheless, researchers and clinicians still frequently face the problem of acquiring enough high-quality DNA for analysis. Whole-genome amplification (WGA) methods offer a solution for this problem, and earlier studies have shown that WGA samples perform reasonably well in small-scale genetic analyses (e.g. Affymetrix 10K array). To determine the performance of WGA products on a large-scale genotyping array, we compared the Affymetrix 250K array genotyping results of genomic DNA and their WGA products from four individuals. Our results indicate that WGA product performs well on the 250K array compared to genomic DNA, especially when using the BRLMM calling algorithm. WGA samples have high call rates (97.5% on average, compared to 99.4% for genomic DNA) and excellent concordance rates with their corresponding genomic DNA samples (98.7% on average). In addition, no apparent systematic genomic amplification bias can be detected. This study demonstrates that, although there is a slight decrease in the total call rates, WGA methods provide a reliable approach for increasing the amount of DNA samples for use with a common SNP genotyping array.  相似文献   

3.

Background

Whole genome amplification (WGA) promises to eliminate practical molecular genetic analysis limitations associated with genomic DNA (gDNA) quantity. We evaluated the performance of multiple displacement amplification (MDA) WGA using gDNA extracted from lymphoblastoid cell lines (N = 27) with a range of starting gDNA input of 1–200 ng into the WGA reaction. Yield and composition analysis of whole genome amplified DNA (wgaDNA) was performed using three DNA quantification methods (OD, PicoGreen® and RT-PCR). Two panels of N = 15 STR (using the AmpFlSTR® Identifiler® panel) and N = 49 SNP (TaqMan®) genotyping assays were performed on each gDNA and wgaDNA sample in duplicate. gDNA and wgaDNA masses of 1, 4 and 20 ng were used in the SNP assays to evaluate the effects of DNA mass on SNP genotyping assay performance. A total of N = 6,880 STR and N = 56,448 SNP genotype attempts provided adequate power to detect differences in STR and SNP genotyping performance between gDNA and wgaDNA, and among wgaDNA produced from a range of gDNA templates inputs.

Results

The proportion of double-stranded wgaDNA and human-specific PCR amplifiable wgaDNA increased with increased gDNA input into the WGA reaction. Increased amounts of gDNA input into the WGA reaction improved wgaDNA genotyping performance. Genotype completion or genotype concordance rates of wgaDNA produced from all gDNA input levels were observed to be reduced compared to gDNA, although the reduction was not always statistically significant. Reduced wgaDNA genotyping performance was primarily due to the increased variance of allelic amplification, resulting in loss of heterozygosity or increased undetermined genotypes. MDA WGA produces wgaDNA from no template control samples; such samples exhibited substantial false-positive genotyping rates.

Conclusion

The amount of gDNA input into the MDA WGA reaction is a critical determinant of genotyping performance of wgaDNA. At least 10 ng of lymphoblastoid gDNA input into MDA WGA is required to obtain wgaDNA TaqMan® SNP assay genotyping performance equivalent to that of gDNA. Over 100 ng of lymphoblastoid gDNA input into MDA WGA is required to obtain optimal STR genotyping performance using the AmpFlSTR® Identifiler® panel from wgaDNA equivalent to that of gDNA.
  相似文献   

4.
Lee CI  Leong SH  Png AE  Choo KW  Syn C  Lim DT  Law HY  Kon OL 《Nature protocols》2006,1(5):2185-2194
We describe a protocol that uses a bioinformatically optimized primer in an isothermal whole genome amplification (WGA) reaction. Overnight incubation at 37 degrees C efficiently generates several hundred- to several thousand-fold increases in input DNA. The amplified product retains reasonably faithful quantitative representation of unamplified whole genomic DNA (gDNA). We provide protocols for applying this isothermal primer extension WGA protocol in three different techniques of genomic analysis: comparative genomic hybridization (CGH), genotyping at simple tandem repeat (STR) loci and screening for single base mutations in a common monogenic disorder, beta-thalassemia. gDNA extracted from formalin-fixed paraffin-embedded (FFPE) tissues can also be amplified with this protocol.  相似文献   

5.

Background

Genome-wide profiling of single-nucleotide polymorphisms is receiving increasing attention as a method of pre-implantation genetic diagnosis in humans and of commercial genotyping of pre-transfer embryos in cattle. However, the very small quantity of genomic DNA in biopsy material from early embryos poses daunting technical challenges. A reliable whole-genome amplification (WGA) procedure would greatly facilitate the procedure.

Results

Several PCR-based and non-PCR based WGA technologies, namely multiple displacement amplification, quasi-random primed library synthesis followed by PCR, ligation-mediated PCR, and single-primer isothermal amplification were tested in combination with different DNA extractions protocols for various quantities of genomic DNA inputs. The efficiency of each method was evaluated by comparing the genotypes obtained from 15 cultured cells (representative of an embryonic biopsy) to unamplified reference gDNA. The gDNA input, gDNA extraction method and amplification technology were all found to be critical for successful genome-wide genotyping. The selected WGA platform was then tested on embryo biopsies (n = 226), comparing their results to that of biopsies collected after birth. Although WGA inevitably leads to a random loss of information and to the introduction of erroneous genotypes, following genomic imputation the resulting genetic index of both sources of DNA were highly correlated (r = 0.99, P<0.001).

Conclusion

It is possible to generate high-quality DNA in sufficient quantities for successful genome-wide genotyping starting from an early embryo biopsy. However, imputation from parental and population genotypes is a requirement for completing and correcting genotypic data. Judicious selection of the WGA platform, careful handling of the samples and genomic imputation together, make it possible to perform extremely reliable genomic evaluations for pre-transfer embryos.

Electronic supplementary material

The online version of this article (doi:10.1186/1471-2164-15-889) contains supplementary material, which is available to authorized users.  相似文献   

6.
We have established that whole genome amplification (WGA), in conjunction with genomic DNA array comparative genomic hybridisation (gaCGH) allows for the identification of genome-wide copy number abnormalities (CNAs) in DNA extracted from both cell line and patient material. To determine the fidelity and reproducibility of WGA to detect copy number imbalances using gaCGH, well characterized cell line genomic DNA was analysed. The gaCGH data obtained from non-amplified DNA and amplified DNA for the neuroblastoma cell line NUB7 and a paediatric medulloblastoma patient was almost identical. In addition, laser capture microdissection (LCM) of prostate tumour cells and subsequent WGA allowed for the detection of a number of CNAs that may not have been identified if DNA had been extracted in bulk from heterogeneous tissue. The results presented here demonstrate the use of WGA for generating sufficient DNA for gaCGH analysis without the introduction of significant sequence representation bias. The combination of amplification and gaCGH using DNA extracted from archival patient material has the potential for permitting the studying of DNA from small cancerous or pre-cancerous foci, which may help to identify potential genomic markers for early diagnosis.  相似文献   

7.
DNA quantity can be a hindrance in ecological and evolutionary research programmes due to a range of factors including endangered status of target organisms, available tissue type, and the impact of field conditions on preservation methods. A potential solution to low‐quantity DNA lies in whole genome amplification (WGA) techniques that can substantially increase DNA yield. To date, few studies have rigorously examined sequence bias that might result from WGA and next‐generation sequencing of nonmodel taxa. To address this knowledge deficit, we use multiple displacement amplification (MDA) and double‐digest RAD sequencing on the grey mouse lemur (Microcebus murinus) to quantify bias in genome coverage and SNP calls when compared to raw genomic DNA (gDNA). We focus our efforts in providing baseline estimates of potential bias by following manufacturer's recommendations for starting DNA quantities (>100 ng). Our results are strongly suggestive that MDA enrichment does not introduce systematic bias to genome characterization. SNP calling between samples when genotyping both de‐novo and with a reference genome are highly congruent (>98%) when specifying a minimum threshold of 20X stack depth to call genotypes. Relative genome coverage is also similar between MDA and gDNA, and allelic dropout is not observed. SNP concordance varies based on coverage threshold, with 95% concordance reached at ~12X coverage genotyping de‐novo and ~7X coverage genotyping with the reference genome. These results suggest that MDA may be a suitable solution for next‐generation molecular ecological studies when DNA quantity would otherwise be a limiting factor.  相似文献   

8.
We evaluated a whole genome amplification method—multiple displacement amplification (MDA)—as a means to conserve valuable nonhuman primate samples. We tested 148 samples from a variety of species and sample sources, including blood, tissue, cell-lines, plucked hair and noninvasively collected semen. To evaluate genotyping success and accuracy of MDA, we used routine genotyping methods, including short tandem repeat (STR) analysis, denaturing gradient gel electrophoresis (DGGE), Alu repeat analysis, direct sequencing, and nucleotide detection by tag-array minisequencing. We compared genotyping results from MDA products to genotypes generated from the original (non-MD amplified) DNA samples. All genotyping methods showed good results with the MDA products as a DNA template, and for some samples MDA improved genotyping success. We show that the MDA procedure has the potential to provide a long-lasting source of DNA for genetic studies, which would be highly valuable for the primate research field, in which genetic resources are limited and for other species in which similar sampling constraints apply.  相似文献   

9.
When cytobrush buccal cell samples have been collected as a genomic DNA (gDNA) source for an epidemiological study, whole genome amplification (WGA) can be critical to maintain sufficient DNA for genotyping. We evaluated REPLI-g WGA using gDNA from two paired cytobrushes (cytobush 'A' kept in a cell lysis buffer, and 'B' dried and kept at room temperature for 3 days, and frozen until DNA extraction) in a pilot study (n=21), and from 144 samples collected by mail in a breast cancer study. WGA success was assessed as the per cent completion/concordance of STR/SNP genotypes. Locus amplification bias was assessed using quantitative PCR of 23 human loci. The pilot study showed > 98% completion but low genotype concordance between cytobrush wgaDNA and paired blood gDNA (82% and 84% for cytobrushes A and B, respectively). Substantial amplification bias was observed with significantly lower human gDNA amplification from cytobrush B than A. Using cytobrush gDNA samples from the breast cancer study (n =20), an independent laboratory demonstrated that increasing template gDNA to the REPLI-g reaction improved genotype performance for 49 SNPs; however, average completion and concordance remained below 90%. To reduce genotype misclassification when cytobrush wgaDNA is used, inclusion of paired gDNA/wgaDNA and/or duplicate wgaDNA samples is critical to monitor data quality.  相似文献   

10.
We assessed the whole genome amplification strategy, known as multiple displacement amplification (MDA), for use with the TaqMan genotyping platform for DNA samples derived from two case-control studies nested in the Nurses' Health Study and the Physicians' Health Study. Our objectives were to (1) quantify DNA yield from samples of varying starting concentrations and (2) assess whether MDA products give an accurate representation of the original genomic sequence. Multiple displacement amplification yielded a mean 23000-fold increase in DNA quantity and genotyping results demonstrate 99.95% accuracy across six SNPs from four genes for 352 samples included in this study. These results suggest that MDA will provide a sufficiently robust amplification of limiting samples of genomic DNA that can be used for SNP genotyping in large case-control studies of complex diseases.  相似文献   

11.
The ability to genotype multiple loci of single cells would be of significant benefit to investigations of cellular processes such as oncogenesis, meiosis, fertilization, and embryogenesis. We report a simple two-step, single-tube protocol for whole-genome amplification (WGA) from single human cells using components of the GenomiPhi V2 DNA Amplification kit. For the first time, we demonstrate reliable generation of 4-7 microg amplified DNA from a single human cell within 4 h with a minimum amount of artifactual DNA synthesis. DNA amplified from single cells was genotyped for 13 heterozygous short tandem repeats (STRs) and 7 heterozygous single nucleotide polymorphisms (SNPs), and the genotyping results were compared with purified genomic DNA. Accuracy of genotyping (percent of single-cell amplifications genotyped accurately for any particular STR or SNP) varied from 37% to 100% (with an average of 80%) for STRs and from 89% to 100% (averaging 94%) for SNPs. We suggest that the method described in this report is suitable for WGA from single cells, the product of which can be subsequently used for many applications, such as preimplantation genetic analysis (PGD).  相似文献   

12.
Abstract

When cytobrush buccal cell samples have been collected as a genomic DNA (gDNA) source for an epidemiological study, whole genome amplification (WGA) can be critical to maintain sufficient DNA for genotyping. We evaluated REPLI-g? WGA using gDNA from two paired cytobrushes (cytobush ‘A’ kept in a cell lysis buffer, and ‘B’ dried and kept at room temperature for 3 days, and frozen until DNA extraction) in a pilot study (n=21), and from 144 samples collected by mail in a breast cancer study. WGA success was assessed as the per cent completion/concordance of STR/SNP genotypes. Locus amplification bias was assessed using quantitative PCR of 23 human loci. The pilot study showed > 98% completion but low genotype concordance between cytobrush wgaDNA and paired blood gDNA (82% and 84% for cytobrushes A and B, respectively). Substantial amplification bias was observed with significantly lower human gDNA amplification from cytobrush B than A. Using cytobrush gDNA samples from the breast cancer study (n =20), an independent laboratory demonstrated that increasing template gDNA to the REPLI-g reaction improved genotype performance for 49 SNPs; however, average completion and concordance remained below 90%. To reduce genotype misclassification when cytobrush wgaDNA is used, inclusion of paired gDNA/wgaDNA and/or duplicate wgaDNA samples is critical to monitor data quality.  相似文献   

13.
Multiple displacement amplification (MDA) is a recently described method of whole-genome amplification (WGA) that has proven efficient in the amplification of small amounts of DNA, including DNA from single cells. Compared with PCR-based WGA methods, MDA generates DNA with a higher molecular weight and shows better genome coverage. This protocol was developed for preimplantation genetic diagnosis, and details a method for performing single-cell MDA using the phi29 DNA polymerase. It can also be useful for the amplification of other minute quantities of DNA, such as from forensic material or microdissected tissue. The protocol includes the collection and lysis of single cells, and all materials and steps involved in the MDA reaction. The whole procedure takes 3 h and generates 1-2 microg of DNA from a single cell, which is suitable for multiple downstream applications, such as sequencing, short tandem repeat analysis or array comparative genomic hybridization.  相似文献   

14.
As the number of single-nucleotide polymorphism (SNP) screening and other mutation scanning studies have increased explosively, following the development of high-throughput instrumentation, it becomes even more important to have sufficient template DNA. The source of DNA is often limited, especially in epidemiological studies, which require many samples as well as enough DNA to perform numerous SNP screenings or mutation scannings. Therefore, the aim is to solve the problem of stock DNA limitation. This need has been an important reason for the development of whole genome amplification (WGA) methods. Several systems are based on Phi29 polymerase multiple displacement amplification (MDA) or on DNA fragmentation (OmniPlex). Using TaqMan SNP genotyping assays, we have tested four WGA systems -- AmpliQ Genomic Amplifier Kit, GenomiPhi, Repli-g, and GenomePlex -- on DNA extracted from Guthrie cards to evaluate the amplification bias, concordance- and call rates, cost efficiency, and flexibility. All systems successfully amplified picograms of DNA from Guthrie cards to micrograms of product without loss of heterozygosity and with minimal allelic bias. A modified AmpliQ set up was chosen for further evaluation. In all, 2,000 SNP genotyping results from amplified and nonamplified samples were compared and the concordance rates between the samples were 99.7%. The call rate using the TaqMan system was 99.8%. DNA extracted from Guthrie cards and amplified with one of the four evaluated WGA systems is applicable in epidemiological genetic screenings. System choice should be based on requirements for system flexibility, product yield, and use in subsequent analysis.  相似文献   

15.
Yan J  Feng J  Hosono S  Sommer SS 《BioTechniques》2004,37(1):136-8, 140-3
Well-characterized epidemiological resources are generated with great effort, yet associated patient DNA samples can be limiting. The efficacy of the whole genome amplification (WGA) method, termed multiple displacement amplification (MDA), was assessed for detecting heterozygous sequence variants, mutation scanning, and PCR for challenging segments. Fifteen common polymorphisms from 10 genes located on 8 chromosomes were genotyped by direct sequencing of 300 PCR products from 115 high-quality MDA-amplified DNA samples extracted by different methods. The GC content of these analyzed segments ranges from 30% to 69%. Genotyping results demonstrate 100% accuracy. For heterozygotes, the relative intensity of peaks generated by the two alleles is highly similar for genomic and MDA-amplified genomic DNA, independent of GC content. In contrast, one of four heterozygous loci was mistyped when lower quality MDA-amplified DNA samples were used. The results of single-stranded conformation polymorphism (SSCP)-type of mutation scanningfor seven MDA-amplified DNA samples in four genes were concordant with the genomic DNA samples. PCR on MDA-amplified DNA was routinely successful for challenging 10- and 12-kb segments with GC content ranging from 30% to 80%, demonstrating that rather long segments, which are difficult to amplify with PCR, are amplified well with MDA. These results suggest that MDA is an effective method of WGA with utility in molecular epidemiology. Quality control of the MDA-amplified DNA is critical for high performance.  相似文献   

16.
Conservation and population genetic studies are sometimes hampered by insufficient quantities of high quality DNA. One potential way to overcome this problem is through the use of whole genome amplification (WGA) kits. We performed rolling circle WGA on DNA obtained from matched hair and tissue samples of North American red squirrels (Tamiasciurus hudsonicus). Following polymerase chain reaction (PCR) at four microsatellite loci, we compared genotyping success for DNA from different source tissues, both pre‐ and post‐WGA. Genotypes obtained with tissue were robust, whether or not DNA had been subjected to WGA. DNA extracted from hair produced results that were largely concordant with matched tissue samples, although amplification success was reduced and some allelic dropout was observed. WGA of hair samples resulted in a low genotyping success rate and an unacceptably high rate of allelic dropout and genotyping error. The problem was not rectified by conducting PCR of WGA hair samples in triplicate. Therefore, we conclude that WGA is only an effective method of enhancing template DNA quantity when the initial sample is from high‐yield material.  相似文献   

17.

Background

Until recently, only a small number of low- and mid-throughput methods have been used for single nucleotide polymorphism (SNP) discovery and genotyping in grapevine (Vitis vinifera L.). However, following completion of the sequence of the highly heterozygous genome of Pinot Noir, it has been possible to identify millions of electronic SNPs (eSNPs) thus providing a valuable source for high-throughput genotyping methods.

Results

Herein we report the first application of the SNPlex? genotyping system in grapevine aiming at the anchoring of an eukaryotic genome. This approach combines robust SNP detection with automated assay readout and data analysis. 813 candidate eSNPs were developed from non-repetitive contigs of the assembled genome of Pinot Noir and tested in 90 progeny of Syrah × Pinot Noir cross. 563 new SNP-based markers were obtained and mapped. The efficiency rate of 69% was enhanced to 80% when multiple displacement amplification (MDA) methods were used for preparation of genomic DNA for the SNPlex assay.

Conclusion

Unlike other SNP genotyping methods used to investigate thousands of SNPs in a few genotypes, or a few SNPs in around a thousand genotypes, the SNPlex genotyping system represents a good compromise to investigate several hundred SNPs in a hundred or more samples simultaneously. Therefore, the use of the SNPlex assay, coupled with whole genome amplification (WGA), is a good solution for future applications in well-equipped laboratories.  相似文献   

18.

Background

Rolling circle amplification of ligated probes is a simple and sensitive means for genotyping directly from genomic DNA. SNPs and mutations are interrogated with open circle probes (OCP) that can be circularized by DNA ligase when the probe matches the genotype. An amplified detection signal is generated by exponential rolling circle amplification (ERCA) of the circularized probe. The low cost and scalability of ligation/ERCA genotyping makes it ideally suited for automated, high throughput methods.

Results

A retrospective study using human genomic DNA samples of known genotype was performed for four different clinically relevant mutations: Factor V Leiden, Factor II prothrombin, and two hemochromatosis mutations, C282Y and H63D. Greater than 99% accuracy was obtained genotyping genomic DNA samples from hundreds of different individuals. The combined process of ligation/ERCA was performed in a single tube and produced fluorescent signal directly from genomic DNA in less than an hour. In each assay, the probes for both normal and mutant alleles were combined in a single reaction. Multiple ERCA primers combined with a quenched-peptide nucleic acid (Q-PNA) fluorescent detection system greatly accellerated the appearance of signal. Probes designed with hairpin structures reduced misamplification. Genotyping accuracy was identical from either purified genomic DNA or genomic DNA generated using whole genome amplification (WGA). Fluorescent signal output was measured in real time and as an end point.

Conclusions

Combining the optimal elements for ligation/ERCA genotyping has resulted in a highly accurate single tube assay for genotyping directly from genomic DNA samples. Accuracy exceeded 99 % for four probe sets targeting clinically relevant mutations. No genotypes were called incorrectly using either genomic DNA or whole genome amplified sample.  相似文献   

19.
Embryo transfer is a reproductive technique that has a major impact on the dissemination of economically important genes and the rate of genetic gain in breeding schemes. In recent years, there has been increasing interest in the use of sexed and genotyped embryos in commercial embryo transfer programs. Marker/gene assisted selection (MAS / GAS) projects can be performed in the pre-implantation stage through mass production of characterized embryos. Biopsy of a few cells in the morulla stage is essential for pre-implantation genetic diagnosis (PGD), in which sex determination, evaluation of disease genes, and genotyping for candidate genes are performed. Limited quantity of cells and low amount of DNA restrict the use of multiple molecular analyses in PGD programs. Recently, whole genome amplification (WGA) techniques promise to overcome this problem by providing sufficient input DNA for analysis. Among several techniques proposed for WGA, the primer extension pre-amplification (PEP) and the improved-primer extension pre-amplification (I-PEP) methods are the most commonly used. However, these methods are time-consuming and need more than 12 h amplification cycles. Since the time is a critical parameter in the successful characterized embryo transfer, the shortening of diagnosis time is highly desirable. In this study, we developed a short and simple I-PEP procedure (~3 h) and evaluated its performance for the amplification of bovine genomic DNA. We assessed short WGA procedure by polymerase chain reaction (PCR) amplification of 7 specific loci. The results indicated that the short procedure possesses enough sensitivity for the molecular genetic analysis of 1 input cell. Although the efficiency of the method was 100%, there was an inconsistency between genomic DNA (gDNA) and whole genome amplification product (wgaDNA) genotypes for kappa-casein locus; that is, however, most likely due to allele drop-out (ADO) or false homozigocity. The results of this study indicate that with the application of reliable methods, WGA-amplified bovine DNA will be a useful source for sexing and genotyping bovine embryos in several quantitative trait locus (QTL) markers.  相似文献   

20.
Evidentiary items sometimes contain an insufficient quantity of DNA for routine forensic genetic analysis. These so-called low copy number DNA samples (< 100 pg of genomic DNA) often fall below the sensitivity limitations of routine DNA analysis methods. Theoretically, one way of making such intractable samples amenable to analysis would be to increase the number of starting genomes available for subsequent STR (short tandem repeat) analysis by a whole genome amplification strategy (WGA). Although numerous studies employing WGA have focused primarily on clinical applications, few in-depth studies have been conducted to evaluate the potential usefulness of these methods in forensic casework. After an initial evaluation of existing methods, a modified WGA strategy was developed that appears to have utility for low copy number forensic casework specimens. The method employs a slight, but important, modification of the "improved primer extension preamplification PCR" method (I-PEP-PCR), which we term mIPEP (modified-I-PEP-PCR). Complete autosomal STR and Y-STR (Y chromosome short tandem repeat) profiles were routinely obtained with 5 pg of template DNA, which is equivalent to 1-2 diploid cells. Remarkably, partial Y- and autosomal STR profiles were obtained from mIPEP-treated DNA recovered from bloodstains exposed to the outside environment for 1 year whereas non-mIPEP-treated samples did not produce profiles. STR profiles were obtained from contact DNA from single dermal ridge fingerprints when the DNA was subjected to prior mIPEP amplification but not when the mIPEP step was omitted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号